Ultrasonic Anemometer with Light &
UV, Thermo-hygrometer Sensors
Model: WS80
WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
- Please scan the QR code to read English manual and keep it for future reference
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
- Qr Code](https://manuals.plus/wp-content/uploads/2024/01/Ecowitt-WS80 -Ultrasonic-Anemometer-with-Light-UV-Thermo-hygrometer-Sensors-Qr-Code.png)
Instruction manuals
https://www.ecowitt.com/support/download/46
Help
Our product is continuously changing and impro-ving, parti cularly online
services and associated applications. To dow nload the latest manual and
additional help, please contact our technical sup-port team:
support@ecowitt.com
support.eu@ecowitt.net (EU/UK)
AC WORKS CONSULTING Sc
Via Vilfredo Pareto 125,47521
Casena(FC),ITALY
HUA TENG LIMITED
3 Glass Street, Hanley, Stoke On Trent,
ST1 2ET United Kingdom
Introduction
Thanks for your purchasing this WS80 6-in-1 Ultrasonic Sensor Package. This
device measures wind speed, wind direction, temperature, humidity, UV Index
and solar radiation. The Ultrasonic Sensor Package is solar powered and sends
data to the receiver via a low-power radio. The data can be streamed by Wi-Fi
Gateway (sold separately) or HP2551/HP2553 console display (sold separately);
and can be viewed on our WS View Plus or Ecowitt App application after the Wi-
Fi configuration done.
To ensure the best product performance, please read this manual and retain it
for future reference.
Unpacking
Open your weather station box and inspect that the contents are intact (nothing broken) and complete (nothing missing). Inside you should find the following:
QTY | Item Description |
---|---|
1 | Solar powered ultrasonic anemometer with Light and UV, air |
temperature/humidity sensor integrated( optional heater for climate with
snow/ice conditions available)
1| U-Bolts set for mounting on a pole (2pcs/set)
1| Threaded nuts for U-Bolts set (M6 size) (4pcs/set)
1| Mounting arm for ultrasonic anemometer
1| Mounting bracelet for ultrasonic anemometer
1| User manual (this manual)
Table: Package content
If any component is missing from the package, or broken, please contact our
Customer Service department to resolve the issue.
Note: Batteries for the ultrasonic anemometer are not included. You will
need 2 AA size Lithium battery for the ultrasonic anemometer, which is
primarily for startup and backup purpose.
After setup and during normal operation, the unit is getting its power from solar cell.
Note: There’s a built-in heat plate in the 6-in-1 sensor package body, if the lowest temperature at your place is below -3°C, or 26.6°F, and the weather is mostly snowy or rainy, then you may need to activate the heater by supplying an external 12V/1A power to the sensor heating element for melting accumulated snow or ice, which can influence wind measurement accuracy significantly. Please contact us at support@ecowitt.com for the extension cord information if needed.
There’s a built-in thermostat inside the anemometer sensor to control the power supply for the heat plate, which will automatically turn on below 0℃ (30℉ ) and automatically turn off above 10℃ (50℉ ).
Overview
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
- Overview](https://manuals.plus/wp-content/uploads/2024/01/Ecowitt-WS80 -Ultrasonic-Anemometer-with-Light-UV-Thermo-hygrometer-Sensors-Overview.png)
Figure 1: Sensor package assembly components
1. Surface tension conditionerlayer ( patent pending) | 7. Mounting arm |
---|---|
2. Battery compartment | 8. Mounting bracelet and U-bolt set |
3. Temperature & humidity sensor | 9. Power cord for built-in heater |
4. Light & UV sensor, LED indicator | 10. USB port (factory use only ) |
5. Solar Panel | 11.Calibration button (factory use only ) |
6. NORTH alignment indicator | 12. Reset button |
Table: Sensor package assembly component list
Setup Guide
4.1 Install batteries in sensor package
Open the battery compartment with a screwdriver and insert 2 AA batteries in
the battery compartment, and press “Reset” button, the LED indicator on the
back of the sensor package (item 4) will turn on for 3 seconds and then flash
once every 4.8 seconds indicating sensor data transmission. If you did not
pay attention, you may have missed the initial indication. You can always
press the reset button to start over. Make sure you see the flash once every
4.8 seconds.
If sensor has been put outside for some time, and solar panel has charged up
the internal accumulator fully or partially, if you install the 2 AA backup
battery, the system might not start up properly. So you can always make a
system reset by press the “Reset” button.
Figure 2: Battery installation diagram
Note: Please make sure the battery is inserted correctly for its polarity as the system needs its initial power from this backup battery to start up the system before solar panel charges up the accumulator and supply system power afterwards. when in high altitude area, during wintertime, sunshine time is short, thus system needs to be powered from this backup battery, we recommend Lithium batteries to be used for cold weather climates. Please avoid alkaline batteries, especially when internal heater is to be activated during cold and wet weather conditions as when heater activated, the trapped heat inside will warm up internally, and alkaline batteries are extremely susceptible to leakage when temperature is over certain limits.
4.2 Mount ultrasonic anemometer assembly
4.2.1 Before you mount
Before installing your outdoor sensor in the permanent location, we recommend
operating the device for one week in a temporary location with easy access.
This will allow you to check out all of the functions, ensure proper operation
and familiarize you with the device performance.
4.2.2 Mounting
- You can attach a pole(not included) to a permanent structure and then attach the sensor package to it (see Figure 3-8).
- The U-Bolts will accommodate a pole diameter of 1.25-2 inches (pole not included).
- Install the base on a pole (1.25inch~2inch) as Figure
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
-
Sensor package mounting diagram](https://manuals.plus/wp- content/uploads/2024/01/Ecowitt-WS80-Ultrasonic-Anemometer-with-Light-UV- Thermo-hygrometer-Sensors-Sensor-package-mounting-diagram.png)Figure 3: Sensor package mounting diagram 6-1
- Pass the connector cord through the arm tube as Figure 4:
- Attaching the arm tube to the Ultrasonic Sensor as Figure 5. Figure 5: Sensor package mounting diagram 6-3
- Install the base with U-bolts and threaded nuts to a pole (not included) as Figure 6 shows:Figure 6: Sensor package mounting diagram 6-4
- Insert the arm tube into the base as Figure 7. Be sure to line up the small hole in the arm with the holes in the base. Insert the machine screw through the holes in the base and arm. ( if you don’t need to power up the heater, you should keep the power
cord terminal inside the mounting arm and this can make the installation looks neat and tidy. You may take it out when needed.)
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
-
mounting diagram](https://manuals.plus/wp-content/uploads/2024/01/Ecowitt- WS80-Ultrasonic-Anemometer-with-Light-UV-Thermo-hygrometer-Sensors-mounting- diagram.png)Figure 7: Sensor package mounting diagram 6-5
Make sure the mounting pole is vertical, or very close to it. Use a level as needed.- During wintertime, to prevent ice formed on the reflection surface, we recommend that you purchase an additional 3M extension cord and connect the cord to the connector as Figure 8 show.
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
- During wintertime, to prevent ice formed on the reflection surface, we recommend that you purchase an additional 3M extension cord and connect the cord to the connector as Figure 8 show.
-
mounting diagram 6](https://manuals.plus/wp-content/uploads/2024/01/Ecowitt- WS80-Ultrasonic-Anemometer-with-Light-UV-Thermo-hygrometer-Sensors-mounting- diagram-6.png)
- If optional extension cord is added, connect extension cord and then connector AC adaptor as Figure 9 show:
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
- If optional extension cord is added, connect extension cord and then connector AC adaptor as Figure 9 show:
-
diagram 6](https://manuals.plus/wp-content/uploads/2024/01/Ecowitt-WS80 -Ultrasonic-Anemometer-with-Light-UV-Thermo-hygrometer-Sensors- diagram-6.png)Figure 9: Sensor package mounting diagram 6-7
Finally, place the sensor package on top of the prepared mounting pipe. The U-Bolts should be loose enough to allow this but loosen the nuts as necessary. Once placed, hand tighten all four nuts, taking care to do so evenly. Do not use a wrench yet!
Now you will need to align the whole package in the proper direction by rotating it on top of the mounting pipe as needed. Locate the arrow labeled “NORTH” that you will find on top of the connector tube of the sensor package (item 6). You must rotate the whole sensor package until this arrow points due north. To achieve proper alignment, it is helpful to use a compass (many cell phones have a compass application). Once rotated in the correct orientation, lightly tighten the bolts a little more (use a wrench) to prevent further rotation.
Note: In Southern hemisphere, it is not necessary to change the orientation to SOUTH as its solar panel is a rounded type and it is orientation free for its charging capability.
Make sure the mounting tube for the sensor package is installed vertically
(use a level at 90-degree offsets around the tube). Adjust the mounting pipe
as necessary. Next also make sure the mounting of the anemometer body on the
pipe is level. If it is not, wind direction and speed readings may not operate
correctly or accurately. Adjust the mounting assembly as necessary.
Make sure you check, and correct if necessary, the north orientation again, as
the final installation step, and now tighten the bolts with a wrench. Do not
over tighten, but make sure strong wind and/or rain cannot move the sensor
package.
4.2.3 Reset Button and Transmitter LED
In the event the sensor package is not transmitting, reset the sensor.
Using a bent-open paperclip, press and hold the RESET BUTTON (item 12) to
affect a reset: the LED turns on while the RESET button is depressed, and you
can now let go. The LED should then resume as normal, flashing approximately
once every 4.8 seconds.
Wi-Fi Configure with gateway
If you want to view the Ultrasonic Sensor data on your mobile application, you need to pair this device with our Wi-Fi Gateway or HP2551/HP2553 display console (sold separately).
5.1 Pair with gateway or display console
Please follow the tips to pair your sensor(s) with the Wi-Fi Gateway or
HP2550/HP2551 display console:
- Power on the gateway first (with USB connection) or HP2551/HP2553 display console (with adaptor connection)
- Power on the Ultrasonic sensor.
- The RF status indicator of the gateway will light on steady, and light off once when it receives the data from the optional sensor(s) once.
- If work normally, you can forward to the Wi-Fi connection operation.
5.2 Wi-Fi Connection
For this part, please refer to the manual of the Wi-Fi gateway or
HP2551/HP2553 Wi-Fi Weather Station.
Any question, please contact the customer service.
View Online Data on WS View Plus or Ecowitt App
When the Wi-Fi configuration is done, you can view the live data of your ultrasonic sensor on the WS View Plus or Ecowitt App application(only for the WiFi gateway).
![Ecowitt WS80 Ultrasonic Anemometer with Light & UV Thermo-hygrometer Sensors
- WiFi gateway](https://manuals.plus/wp-content/uploads/2024/01/Ecowitt-WS80 -Ultrasonic-Anemometer-with-Light-UV-Thermo-hygrometer-Sensors-WiFi- gateway.png)
Specification
7.1 Wireless Specifications:
Frequency: 433/868/915/920MHz depending on locati on (North
American:915MHz; Europe:868MHz; Othe r areas:433/920MHz)
Transmission distance in open field:
150m(492 ft) for RF Frequency :915 Mhz /868 Mhz /920Mhz/433MHz
Sensor reporting interval: 4.8 seconds
Note:
- When the maximum wind speed of the last 4s is >=5m/s, the wind speed is detected by 1s; when the maximum wind speed of the last 4s is >=3m/s and less than 5m/s, the wind speed is detected by 2s; when the maximum wind speed of the last 4s is <3m/ s, the wind speed is detected by 4s.
- The wind speed reading will be a real-time value (The latest sampling data will be reporting to the receiver).
- The wind gust reading will be the max wind speed in the past 28s.
- When the wind speed is lower than 5m/s, the dispersion of wind direction will increase.
7.2 Measurement Specification
Measurement | Range | Accuracy | Resolution |
---|---|---|---|
Wind speed | 0~40m/s | <10m/s, |
+/-0.5m/s
≥10m/s,
+/-5%| 0.1M/S
Wind
direction| 0~359°| <10m/s, TBA≥10m/s, ±1 5°| 1°
Temperature| -40~60℃| ±1℃| 0.1℃
Humidity| 1~99%| ±5%| 1%
Light| 0~200Klux| ±15%| 10Lux
UVI| 1~15| ±2| 1
7.3 Power consumption
Power | Specification |
---|---|
Anemometer sensor | Solar panel (built-in): 6.5V/4mA |
2 x AA 1.5V Lithium battery |
(not included)
Note: The primary power source for the sensor is the solar panel. When available solar power (light over recent period) is insufficient, the batteries will be used.
Warranty Information
We disclaim any responsibility for any technical error or printing error, or
the consequences thereof.
All trademarks and patents are recognized.
We provide a 1-year limited warranty on this product against manufacturing
defects, or defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only
on products purchased, and only to the original purchaser of this product. To
receive warranty service, the purchaser must contact us for problem
determination and service procedures.
This limited warranty covers only actual defects within the product itself and
does not cover the cost of installation or removal from a fixed installation,
normal set-up or adjustments, or claims based on misrepresentation by the
seller, or performance variations resulting from installation-related
circumstances.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>