Real Relax BS-02 Full Body Massage Chair User Manual
- June 16, 2024
- Real Relax
Table of Contents
Real Relax BS-02 Full Body Massage Chair User Manual
SAFETY PRECAUTIONS
- Before using, please read this “SAFETY PRECAUTIONS” carefully to ensure proper operation.
- Following “SAFETY PRECAUTION of great help to your use of this massage chair correctly.
- To clearly indicate the degrees of danger and damage, the accidents caused by incorrect use are classified into “WARNINGT’ and “FORBIDDEN”. Instructions marked as follows should be strictly followed
MEDICAL WARNINGS
NOT RECOMMENDED FOR THE FOLLOWING PEOPLE.
-
Patients with serious hyperostosis
-
Swollen lump and patient thrombosis
-
Patients with serious heart conditions
-
Pregnant Women
-
People that consume large amounts of alcohol
-
People with diabetes
-
People suffering from high fever
-
Patients with malignant tumors or malignant abscesses
-
People with distorted joints
-
People with serious skin conditions
-
People with spinal injuries
-
Al people should consult a physician and exercise care when operating this system Minors under 16 years or people unable to control their behavior, such as mental patients, people with
paralysis, etc. -
Should not be allowed to operate the massage chair.
WARNINGS
- Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
- Never operate this chair if it has a damaged cord or plug.
- Keep the cord away from heated surfaces.
- Please empty pockets and remove all your arm Jewellery and watch before using this chair.
- Do not operate where aerosol (spray) products are being used.
- To disconnect, turn all controls to the off position, then remove plug from outlet.
- Connect this appliance to a properly grounded outlet only. See grounding instructions.
- Do not remove the back cushion to modify roller mechanism.
- Do not remove the bottom seat to modify actuators.
- Keep the cord out of heavy traffic area.
- Always unplug the power cord from the electrical outlet immediately after use.
- Do not operate any equipment with damaged parts.
- Any other use not recommended by the manufacturer may cause electrical shock or injury.
- Do not touch or re-wire the wires connected to the master-box.
- Do not attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty.
- Do not put your hands or head under the chair
- When using the massage chair, ascertain that the footrest is in the lowest position.
FORBIDDEN
- Do not allow children to play near the chair especially during operation
- Do not leave mobility impaired or speech impaired people alone in chair Do not place or stock this chair near damp places such as swimming pools or bathrooms
- Do not presses massage rollers by force
- Do not stand on the chair or put heavy items on the chair
- Do not use in an environment that is dusty, greasy, or lack of oxygen
- Do not place near steam oven, open fire, or heat
- Wear suitable clothing, do not massage with bare skin
- Do not place it directly in the sun.
- Do not use electric blanket while using the massage chair
- Do not use it outdoors
- Do not use while smoking
- Do no use immediately after meals
- Do not sit on the back cushions, armrest, or legs
- Don’t use the massage chair when your body is wet or moist as it can result in electrical shock
- Do not operate with more than one person
- Don’t use when using head ornamentation as it can result in injury
- Do not stumble over electrical wires or connections
REMOVE PLUG
- Before maintenance, please pull out power plug. In addition, please do not insert or unplug the power plug with damp hands, to avoid electric shock.
- When the massage chair is not in use, please switch off power and remove the plug from socket. When power is off, please cut off power supply immediately and pull out the power plug from socket
.BE CAREFUL
- Please avoid Massaging after drinking or when you are not feeling well.
- Do not massage the head, elbow joints, knees, chest, abdomen, etc. directly on the massage baill.
- Do not damage the power cord; this may result in electric shock or mechanical failure. Please
contact the service center for a detailed inspection.
NAME AND FUNCTION OF EACH COMPONENT
EXTERNAL STRUCTURE
INTERNAL STRUCTURE
- Shoulder Air Massage Unit
- Remote Control
- Armrest Air Massage Unit
- Seat Air Massage Unit
- Calf Air Massage Unit
- Foot Air Massage Unit
- Back massage Points
- Waist Heater
- Slide Rail
- Foot Roller Massage Unit
AUTO MODE
Select Auto massage mode
- Power: when the unit is turned on it will automatically start to message automatic massage modes intensity and strength cannot be adjusted. If you would like to adjust intensity and strength please Selecta specific area. such as: arm, foot, or shoulders.
- Press “Power” to switch time from 15/20/25/30 PressPower button for 2 seconds to turn off massage chair. Auto massage mode will automatically stop when the time comes.
Adjust the reclining angle
- Adjust the angle between backrest and footrest.
Leg extension settings
- Put footrest extend forward to suit taller individuals.
REMOTE CONTROLLER INSTRUCTION
| Auto mode 1
---|---
| Auto mode 2
| Auto mode 3
| Auto mode 4
| Auto mode 5
| Auto mode 6
| Air auto mode switch
| Shoulders airbag switch
| Arms airbag switch
| Hips airbag switch
| Calves airbag switch
| Adjust the intensity of the airbags
| On/Off: Press power button to turn on the chair or adjust time frame, press
for more than 2 second to turn off
| Independent massage roller switch for upper back
| Independent massage roller switch for lumbar back
| In manual mode, increase the massage speed of the rollers
| In manual mode, decrease the massage speed of the rollers
| Turn on or off the waist heating function
| Make the chair into the zero gravity mode
| Foot Roller switch / Long press for 5 seconds to clear the Bluetooth
connection
| Adjust the massage intensity of foot rollers
| Adjust the backrest up
| Adjust the backrest down
CUSTOM MASSAGE MODE
- By selecting a single massage area, auto massage will stop.
- You can turn on a single massage area, or multiple areas.
- This allows you to give yourself a complete customizable massage.
- You can also adjust the intensity of the airbags and speed of the fixed back rollers
MUSIC SYSTEM
Our product is designed with Bluetooth audio connection function. It can play music through connect with smart phone, tablet computer or other audio devices.
How to use:
- 0pen mobile-phone/iPad/computer BLUETOOTH capabilities, and access to the search state, your device will automatically search neighboring BLUETOOTH devices.
- In a few seconds,our massage chair name “Real Relax” will show up under the device list, select “Real Relax” name and the connection complete
.
INSTALLATION METHOD ACCESSORIES FROM BOX €
After dismounting the package, carefully remove the Massage chair and install it according to the instructions.(just plug in the power cord to use).
INSTALLATION STEPS
Step 1 : Connect the air pipe and power cord of the leg assembly to the
host
Step 2 : Uninstall the nut and slide the brocket hole on the right side
into the iron rod of the chair
Step 3 : slide the bracket hole on the left side into the iron rod of the
chair and install the nut
Step 4 : Connect the power line and install the seat
Step 5 : INTAL the bracket and screw it, then put the controller
TURN ON POWER SUPPLY INSTALLATION
-
Plug the power cord into three core socket of good grounding.
-
Press the power switch on the bottom of massage chair.
CAUTION
- Before switching on the chair, please make sure there is no damage on the power wire and other exposed wires.
- Make sure the power switch is off before the chair is connected to electricity.
MOVE METHOD
- There are moving rollers at the bottom of the chair.
- Raise the back to the highest point.
- Switch off and unplug the chair.
- Lift the front part of the chair as shown in the figure (one person raises the front part via holding moving holder, another person pushes the chair when holding the top of the chair), make wheels move.
CAUTION
- Don’t move it when there is people in it.
- Don’t use the armrest while moving the chair, only hold the moving holder in the back and front.
INSTALLATION POSITION
PLEASE LEAVE THE SPACE AROUND THE MASSAGE CHAIR WHEN PREPARING THE MASSAGE
- Place a massage chair where there is enough space for the back of the chair to recline and the footrest to rise.
- Make sure that there is at least 20 cm in the back of the massage chair and at least 20 cm in front of the — massage chair.In order to prevent from signal interference, please keep at least 1m away from the TV, radio and other video and audio devices.
CAUTION
Before using, please tidy up well the cables to avoid twining or damage When the whole chair makes slide movement forward or backward to original position, please check first whether there are kids, pets or any other objects to avoid accidents. Please put carpet or other pad under the massage chair, in order to avoid any unpredictable impression on the floor.
SURROUNDING ENVIRONMENT
| Keep the massage chair away from damp places (for example: bathroom) to
avoid electric leakage
---|---
| Keep the massage chair away from high temperatures sources (for example:
stove) to avoid fire or CAUTION X damage to leather material
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or break down,
grounding provides a path of least
resistance for electric current to reduce the risk of electric shock. This
product is equipped with a cord having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local codes and
ordinances.
Danger – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet; have a proper outlet installed by a qualified electrician.
AFTER USING THE CHAIR
- Please power off the chair and unplug from power the supply socket after using, disconnect the controller and store carefully.
- Please power off the chair and unplug from the power supply socket when the chair is not in use, to avoid children to start the chair accidentally
- Please store well the chair if it is not in use for a long time.
METHODS OF STORAGE
- Do not dismount the back of the chair
- Keep the massage chair free of dust
- Cover the chair with a dust-free cloth to prevent dust from collecting
- Do not store in a hot, humid, damp place or in direct sunlight or heat
- Do not store in an overly cold place
MAINTENANCE
- Before cleaning unplug from electrical source to avoid shock
- Clean the cloth surface with neutral detergent or a special mild detergent for cloth.
- Dust can be cleaned off with a damp cloth or mild detergent and air dry.
- Do not spray pesticide on the device.
- Specified cleaner can be used on the leather, plastic, and dried with a cloth
- Do not use a damp cloth on the electronic components which can cause shock and damage
- The leather covers (headrest, seat cushion, foot cushion) can be removed for cleaning
KIND REMINDING
During daily use, please check whether the following phenomenon exist: Scorched smell When touch the wire, the power is on, but sometimes off The power supply cord is hot Other abnormal phenomenon
CAUTION
If problems happen above, please turn off power supply and contact the distributor or manufacturer for assistance.
TROUBLESHOOTING GUIDE
Problems/Issues | Possible Cause | Trouble Shooting Method |
---|---|---|
Sounds ke tapping or Fum sounds | Sounds from air pump, motor or other | |
mechanical parts | Normal phenomenon | |
Suddenly stops working |
- Bad power connection2.
- Auto program timers is up
|
- Unplug and reinsert power cord to he chair
- Normal
Does not work after power up|
- Power switch is not turned on
- Bad connection between plug and socket
- Massage remote is not turned on
- Have broken power wire plug
- Bad fuse6. Control unit for functioning properly
|
- Turn power switch on2.
- Connection power cord again
- Press power button on remote
- Contact professional technician
- Replace fuse
- Contact professional technician
Roller height changes| Rollers work alternately| Normal phenomenon
Abnormal sounds suddenly while working| Maybe from over working the massage
chair|
- .Cut down usage
- Contact professional technician
Can not recline the chair| Obstruction-be sure that the chair is allowed
enough room to fully recline| Stop chair opearion, and move obstruction
can not restore position after reclined| Problem on electric motion pole or
plug under bad connection| Contact professional technician
ATTENTION
If problems are not from above reasons, please turn off power supply and
contact the distributor or manufacturer for assistance.
Note : Do not dismantle the produce by yourself, and our company shall
shoulder no responsibility to the
damage of the product or the inquiry of people caused by improper use. Thanks
for your cooperation !
Rated Voltage : 110 V
Rated Frequency : 60 Hz
Rated Power : 150 W
Safety Design : Class |
N.W : 115.4 LB
G.W :134.31B
MEAS : 50.7%29.9%23.6 IN
Manufacturer Reserves The Right To Make Changes To Information’s Published In
This Document,
Including Without Limitation Specifications And Product Descriptions, At Any
Time And Without Notice.
Contact Us
For any inquiries or quality-related issues concerning our products, please
send an email to service@ realrelaxmassage.com, we will respond to you as soon
as possible and give you an appropriate solution (refund or replacement).