BCS 2AXPS-WDC Wireless Device Charger User Manual
- June 16, 2024
- BCS
Table of Contents
User Manual
Document ID: WDC
2AXPS-WDC Wireless Device Charger
Wireless Device Charger
Product Description
(WDC)
Version: | Record: | Date: | Prepare: |
---|---|---|---|
A1 | Initial Release | 16.05.2023 | Hua Jiang |
Product Introduction
1.1 Product Introduction The wireless device charger can charge your Qi-enabled
smartphone at up to 15W of power. Just simply place your smartphone on the
charger. The wireless device charger supports up to only one phone at once.
NOTE: The wireless device charger may not work if your phone case is
metal. Take the phone out of the case and place the phone on the charger.
1.2 Mechanical Design
1.2.1 Product 3D View
1.2.2 Product 3D Exploded View 1.2.3 Dimension 2D View ![BCS 2AXPS-WDC Wireless Device Charger
- Dimension 2D View](https://manuals.plus/wp-content/uploads/2024/01/BCS- 2AXPS-WDC-Wireless-Device-Charger-Dimension-2D-View.png)1.3 Product Technial Parameters
Electrical Specification | r Parameters- | Range: |
---|---|---|
Output Power | Max. Output | 15W |
Temperature Range | Operating Temperature | -40°C–85°C |
Storage Temperature | -40°C–85°C | |
Input Parameter | Voltage/Current | 13.5V DC @ 2.5A |
Charging Efficiency | Rx Output Power VS Tx Input Power | Coil Center:>70% |
Charging operating Frequency | / | 127.772kHz |
Chart 1-6 technical parameters
Safety Instructions
- Before using and operating the equipment, please read and observe the following precautions.
- This product meets the technical standards of short distance micro power class an equipment and relevant specifications.
- It is not allowed to disassemble the equipment, change the internal structure, antenna, etc. to avoid danger.
- In places where the use of wireless devices is prohibited according to laws and regulations, such as in-flight, medical and other places, please comply with the relevant regulations and requirements, stop using or turn off the devices. The use of micro power equipment in relevant electromagnetic environmental protection areas shall comply with the requirements of electromagnetic environmental protection and relevant industry authorities.
- The radio waves generated by devices may affect implantable medical devices, such as pacemakers, cochlear implants, hearing aids, etc. When using the wireless charging device, please keep a distance of at least 30 cm from the implanted medical device.
This product has passed the Qi certification of WPC, and can charge the
products that also pass the certification of WPC. Please don’t charge the
wireless charging equipment that doesn’t meet the requirements of Qi, and
don’t use unauthorized or incompatible power supply, charger, battery, etc. to
power the equipment, which may cause fire or other hazards.
This device complies with Part 15 of the FCC Rules and Industry Canada’s
license- exempt RSS Standard(s). Operation is subject to the following two
conditions:
- This device may not cause harmful interference. And
- This device must accept any Interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
This equipment complies with EU radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
This equipment complies with UK radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
The information of local representative in Europe:
Company name: BCS Automotive Interface Solutions
Company address: Olympian Park, Unity 8 – DN6/E70, n.637, Remetea Mare 307350,
jud.
Timis, Romania
Contact Person: Anamaria Casandra
Phone: 0741112534
Email: anamaria.casandra@bcs-ais.com
| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| Fl| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK
The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.