Cutelove 350ML Water Flossers for Teeth User Manual
- June 16, 2024
- CUTELOVE
Table of Contents
ORAL IRRIGATION
USERS MANUAL
Before operating this product, please read these snstructions
completely and save this manual for future use.
(ACTIVATE YOUR LIFETIME WARRANTY!)
Model : AOW09_ MadeinChina
350ML Water Flossers for Teeth
Activate Your
WARRANTY
or scan the ORR code
12 Months
Warranty Extension| Ona on On
Service| VIP
Discount
---|---|---
OR Contact us with CUTELOVEtcustomerservice@outlook.com Activate the Warranty & Any Suggestions & Product Problems, please don’t hesitate to contact us directly, we will always be here to help you
WE WOULD LIKE TO HEAR FROM YOU
IMPORTANT SAFEGUARDS
Thank you for using our Orallrrigator product. In order to let you experience the product swimmingly, detailed instruction is provided and you can find the introduction, usage, and other information as follow
PLEASE READ ALL INSTRUCTIONS BEFORE USING.
Product parameters
Water Pressure | 50-150PSI |
---|---|
Water Tank | 350ML |
Waterproof Level | !PX7 |
Flow Rate | 200ml/min |
Battery capacity | 1800mAh |
Noise | ≤ 72d8 |
Power | 3W |
Charging Voltage | SV |
Charging Current | 2A |
Charging Time | 4 Hours |
Include | rrigator Product |
rrigator Charging Cable1
rrigator Nozzle7
rrigator Product Manual’1
Storage Bag1
Product Description
Product Accessories
1: Tongue scraping1
2: Periodontal pocket nozzle l
3: Orthodontic nozzle l
4: Standard nozzle 4
5: US8chariging cable 1
6: Storage bag
The jet tips and other changeable components can be purchased from retail stores
Operating Instruction
ON/OFF Button: It is the key to power on and off or pause. The first long
press2sis to start up, the second short press is to the product normal
operation, the short press the third time, the product pause, long press 2s
the ON/OFF Button to shut down
Mode Button: It is the working mode selection button. Short press to
switch the S working modes: STRONG-NORMAL-SOFT-PULSE-CHILD
-
Preparation before starting
Very important! For the first time to use, please fully charge the device. During charging, the product CAN NOT be used. -
Insert nozzle
Insert the nozzle into the hole until you hear the click’ sound -
Pour water into the water tank
when pouring water into the water tank, the device is switched off. -
Start up
Press the ON/OFF buttons 2s to start up, and the WELCOME screen will be displayed -
Mode selection
Short press the Mode Button to select the demand working mode
( Orshort press the ON/OFF button to enter the last time mode to start water spraying. )
-
Power on
After selecting the working mode, short press the ON/OF Button again, and the product will work
-
Shut down
The product will automatically power off after 2 minutes of work.If you need the product to shut down during work, just long press 2s the ON/OFF Button again to enter the BYE! screen -
Change nozzle
Power off and remove the tip, press the nozzle release button, and then pull up the nozzle The jet tips and other changeable components can be purchased from retail stores
Usage Tip
Tilt down to place the nozzle in the mouth, and point the nozzle at the tooth, then turn on the device.
Make water jet at 90to the gum, and close your lips slightly to avoid water
spray.
Forbestresults, start with the molars (back teeth) and lean towards the front
teeth.
Slide the tip along the gum line and keep flossing a while at the interdental
place, till everywhere is leaned.
Assembly and Disassembly
Clean water tank
Turn off the device, and open the back tank lid with the injection hole facing
down, then turn on the device after clearing the residual liquid in the tank,
to drain the residual liquid in the device until there is no more water to
drain, then turn off the device.
Remove and clean water tank if necessary
Using both hands as indicated in the Picture below Keep your left hand to hold
the product body, and your right hand to hold the water tank and take off it
You can use brushes to clean the water tank if necessary
(Note: brushes are not included).
Battery Care and Disposal
Battery Maintenance
- For the first use, the device must be fully charged approximately 6 hours.
- If the device is stored for a long time, please fully charge it in advance
- In order to extend battery lifetime, please recharge it in time when power is insufficient
Battery Care and Disposal
- The device includes a lithium battery which cannot be changed
To preserve the environment, do not throw away the appliance with the normal household waste at the end of its life, hand it over to local recycling center
IMPORTANT SAFEGUARDS
Thank you for using our Oral rrigator product. In order to let you
experience the product swimmingly, detailed instruction is provided and you
can find the introduction, usage, and other information as follow
To reduce the risk of injury to persons:
This appliance can be used by children aged 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning the
use of the appliance in asafe way and understand the hazards involved.
- Oral irrigators shall be used only with cold or warm water, or specific solutions as defined in the manufacturer’s instructions
- It must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
- The product contains batteries that are non-replaceable
- Do not plug this device into a voltage system that is different from the voltage system specified on the device or charge.
- Do not direct water under the tongue, into the eat, nose, or other delicate areas. This product is capable of producing pressures that may Cause serious damage in these areas
- Do not direct water into the nose or ear. The potentially deadly amoeba Naegleria fowleri, may be present in some tap water or unchlorinated well water and may be fatal if directed into these areas Use this product only as indicated in these instructions or as recommended by your dental professional
- Magnetic field: Pacemakers and similar implanted medical devices may be affected by magnets
- Donot droporinsert any foreign object into any opening on the product
- Keep the charging unit and cord away from heated surfaces.
- Donotuse this product outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered
- Children shall not play with the appliance. Closely instruct and Supervise children and individuals with special needs in the proper use of this product,Children should be supervised to ensure that they do not play with the appliance
Frequency Asked Question
Problems | Reasons | Solutions |
---|---|---|
leakage of water between jet tip adserewpart | The seal ring on the fined | |
socket for the ole is damaged | Contact the after-sales | |
The nozzle does not install correctly | Re-install correctly | |
Water tank lea.ks water | Seal ring is damaged | Replace the seal ring call |
after-sales
Inadequate pressure| Nozzles damaged| charging
Replace with new nozzle| Lowbattery
Lowvoltage| Charging
Water is not coming out| Nole blocking| Water pipe blocking
Suck the jet tip by mouth| Inject the water from the nozzle
| Shake after ff the water
No temperature and PM showing| Nozzle clogging Water valve plate is too dry|
Suck the jet tip by mouth inject water to the jet tip or fill water into water
tank aghake
Short working time after full charging| Insufficient charging time| Circuit
fault
Charging| Contact after-sales
If the above methods cannot resolve these problems, please consult with the retailer or proceed to the designated after-sales repair site for repairs
Gentle Reminder
- For the first-time usage, please select Child mode, in order to avoid the gums bleeding due to the lack of adaption to usage
- This product is not suitable for children, infants and other operators to use, unless they get their safety responsible person the use of this product supervision or guidance. Keep out of reach of children or infants.Do not use them as toys.
- For patients with periodontal disease or those who have had oral surgery in the last 2 months, please consult your doctor before use
Warranty
Please Take Note Of The Following Issues:
- In accordance with relevant national regulations, the product shall be repaired free of charge within one year due to non-human factors (subject to the date of purchase invoice). The warranty does not cover the accessories, such as jet tips. If the warranty period has expired, please gotothe designated after-sales service center for paid maintenance
Maintenance and repair record
Product Name| | |
---|---|---|---
Model Name| | |
Purchase Date| | |
Customer Name| | |
Phone Number| | |
Contact Address| | |
Default Description| | |
CONTACT:
http://www.cutelovehealth.com
Read User Manual Online (PDF format)