Zephyr ZPO-E36AS Range Hood User Manual

June 16, 2024
ZEPHYR

Zephyr-LOGO

Zephyr ZPO-E36AS Range Hood

Zephyr-ZPO-E36AS-Range-Hood-PRODUCT-IMAGE

Product Information

Specifications

Model: ZPO-E30AS, ZPO-E36AS

Product Usage Instructions

Safety Instructions

IMPORTANT SAFETY INSTRUCTIONS

  • For residential use only.
  • Read and save these instructions.
  • Take care when using cleaning agents or detergents.
  • Suitable for use in household cooking area.
  • Do not use this fan with any Solid-State Speed Control Device to reduce the risk of fire or electric shock.
  • Do not use to exhaust hazardous or explosive materials and vapors.
  • Avoid motor bearing damage and noisy and/or unbalanced impellers by keeping drywall spray, construction dust, etc. off power unit.
  • Read specification label on product for further information and requirements.
  • TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
    • Never leave surface units unattended at high settings as boilovers cause smoke.
    • Proper maintenance of the Range Hood will assure proper performance of the unit.

Installation Instructions

  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
  • Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • Ducted fans must always be vented to the outdoors.
  • This unit must be grounded.
  • Use only metal ductwork to reduce the risk of fire.
  • The manufacturers will not accept any responsibility for eventual damages due to failure to observe the above instructions.

Electrical Requirements

  • Federal Communication Commission Interface Statement
  • Before connecting the model to the electricity network:
  • Control the data plate (positioned inside the appliance) to ascertain that the voltage and power correspond to the network and the socket is suitable. If in doubt, ask a qualified electrician.
  • If the power supply cable is damaged, it must be replaced with another cable or a special assembly, which may be obtained directly from the manufacturer or from the Technical Assistance Centre.
  • Prop. 65 Warning for California Residents:
  • This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

List of Materials

Duct Covers

FAQ

  1. Q: Can I use this range hood in a commercial kitchen?
    A: No, this range hood is suitable for use in household cooking areas only.

  2. Q: Can I use a Solid-State Speed Control Device with this fan?
    A: No, using a Solid-State Speed Control Device with this fan can pose a risk of fire or electric shock.

  3. Q: How should I vent the ducted fans?
    A: Ducted fans must always be vented to the outdoors to ensure proper ventilation.

  4. Q: What type of ductwork should I use?
    A: To reduce the risk of fire, use only metal ductwork for installation.

  5. Q: What should I do if the power supply cable is damaged?
    A: If the power supply cable is damaged, it must be replaced with another cable or a special assembly obtained directly from the manufacturer or from the Technical Assistance Centre.

www.zephyronline.com

Safety instructions 1/5

IMPORTANT SAFETY INSTRUCTIONS

FOR RESIDENTIAL USE ONLY

  • READ AND SAVE THESE INSTRUCTIONS

  • PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
    IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these

  • Instructions with this unit for the owner.
    OWNER: Please retain these instructions for future reference.

  • Take care when using cleaning agents or detergents.

  • Suitable for use in household cooking area.

  • WARNING – To reduce the risk of fire or electric shock, do not use this fan with any Solid-State Speed Control Device.

  • CAUTION – To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

  • CAUTION – For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

  • CAUTION – To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

  • CAUTION – Please read specification label on product for further information and requirements.

  • WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

  • Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

  • To reduce the risk of fire, electric shock or injury to persons, do not use replacement parts that have not been recommended by the manufacturer (e.g. parts made at home using a 3D printer).

  • WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  • Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

  • Always turn hood ON when cooking at high heat or when flambeeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ).

  • Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

  • Use proper pan size. Always use cookware appropriate for the size of the surface element.

  • Keep fan, filters and grease laden surface clean.

  • Use high range setting on range only when necessary. Heat oil slowly on low to medium setting.

  • Don’ t leave range unattended when cooking.

  • Always use cookware and utensils appropriate for the type and amount off food being prepared.

  • WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

  • SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

  • NEVER PICK UP A FLAMING PAN – You may be burned.

  • DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result

  • Use an extinguisher ONLY if:

    • You know you have a Class ABC extinguisher, and you already know how to operate it.
    • The fire is small and contained in the area where it started.
    • The fire department is being called.
    • You can fight the fire with your back to an exit. Based on “kitchen fir safety tips” published by NFPA
    • Proper maintenance of the Range Hood will  assure proper performance of the unit.

INSTALLATION INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire rated construction.
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
  • Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • Ducted fans must always be vented to the outdoors.
  • This unit must be grounded.
  • WARNING – TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
  • WARNING – UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS.
  • Do not check filters with hood working.
  • Do not touch the lamps after a prolonged use of the appliance.
  • No food must be cooked flambè underneath the hood.
  • The use of an unprotected flame is dangerous for the filters and could cause fires.
  • Watch constantly the fried food in order to avoid the cooking oil flares up.
  • Before performing any maintenance operation, disconnect the hood from the electrical service
  • The manufacturers will not to accept any responsibility for eventual damages, because of failure to observe the above instructions.

Electrical Requirements

Important:

  • Observe all governing codes and ordinances.
  • It is the customer’s responsibility to be aware of these below:
  • To contact a qualified electrical installer.
  • To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian
  • Electrical Code, Part 1 and C22.2 No.0-M91 – latest edition** and all local codes and ordinances.
  • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
  • Do not ground to a gas pipe.
  • Check with a qualified electrician if you are not sure the range hood is properly grounded.
  • Do not have a fuse in the neutral or ground circuit.
  • This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product.
  • A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.* National
  • Fire Protection Association Battery march Park, Quincy, Massachusetts 02269
  • CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

Federal Communication Commission Interface Statement

  • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
  • If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
    • Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.

SAFETY PRECAUTION

  • Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend on the air in the environment and are supplied by other than electrical energy, as the cooker hood removes the air from the environment which a burner or fireplace need for combustion. The negative pressure in the environment must not exceed 4Pa (4×10-5 bar). Provide adequate ventilation in the environment for a safe operation of the cooker hood. Follow the local laws applicable for external air evacuation.

  • Before connecting the model to the electricity network:

  • Control the data plate (positioned inside the appliance) to ascertain that the voltage and power correspond to the network and the socket is suitable. If in doubt ask a qualified electrician.

  • If the power supply cable is damaged, it must be replaced with another cable or a special assembly, which may be obtained direct from the manufacturer or from the Technical  Assistance Centre.

  • Warning!
    In certain circumstances electrical appliances may be a danger hazard.

  • Do not check the status of the filters while the cooker hood is operating.

  • Do not touch bulbs or adjacent areas, during or straight after prolonged use of the lighting installation.

  • Flambè cooking is prohibited underneath the cooker hood.

  • Avoid free flame, as it is damaging for the filters and a fire hazard.

  • Constantly check food frying to avoid that the overheated oil may become a fire hazard.

  • Disconnect the electrical plug prior to any maintenance.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.

  • Cleaning and user maintenance shall not be made by children whiteout supervision.

  • Young children should be supervised to ensure they do not play with the appliance.

  • There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels.

  • There is a risk of fire if cleaning is not carried out in accordance with the instructions.

INSTALLATION INSTRUCTIONS

  • Assembly and electrical connections must be carried out by specialised personnel.
  • Wear protective gloves before proceeding with the installation.
  • WARNING Prop. 65 Warning for California Residents: This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

List of Materials

Zephyr-ZPO-E36AS-Range-Hood-2

Ducting Calculation Sheet

Zephyr-ZPO-E36AS-Range-Hood-3 Zephyr-ZPO-E36AS-
Range-Hood-4 Zephyr-ZPO-E36AS-Range-Hood-5

Hood Specifications

  • front of hood

  • side of hoodZephyr-ZPO-E36AS-Range-Hood-6

  • back of hood

  • top of hood

Zephyr-ZPO-E36AS-Range-Hood-7

Installation – Power Supply Connection

GENERAL

  • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations.
  • A: Lift the electrical plant box.
  • B: Remove the 3 fixed screws.
  • C: Position the electrical box so it is in the line with the holes of the previously removed screws and tighten.
  • D: Route the power cord to the junction box.Zephyr-ZPO-E36AS-Range-Hood-8
  • Using listed conduit fittings and connectors, connect the power supply to the box and each line to the appropriate wire following this color convention:
    • BLACK = HOT LEG
    • WHITE = NEUTRAL
    • GREEN/YELLOW = GROUND
    • Polarity must be observed. Unit must be properly grounded. Use a double throw disconnect switch.
    • Replace the box cover. Replace the Anti grease filters.
    • All wiring must be in compliance with national electrical code, ANSI/NFPA 70-1999 and all local codes and regulations.

Installation

  • Mounting the hood to the wall
  • Position the fixing template on the wall (taking into account the minimum distance from the hob).
  • Drill 4 holes respecting the size indicated on the fixing template.
  • Fix the appliance to the wall with screws A and align it horizontally with the wall units. After adjusting the appliance, fix the hood permanently with screws B. For the various  installations, use screws and dowels suitable for the type of wall (e.g. rein-forced concrete, plasterboard, etc.). If screws and dowels are supplied with the product, check that they are suitable for the type of wall to which the hood is to be fixed.
  • Fasten bracket D to the wall so that it is aligned with the hood with screws C .
  • Fasten the decorative chimneys to the hood with screws G.
  • Slide the upper decorative chimney onto bracket D and fasten it with screws E.Zephyr-ZPO-E36AS-Range-Hood-9

Installation – Ducting Options

WARNING FIRE HAZARD

  • NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
  • All exhaust must be ducted to the outside, unless using the recirculating option.
  • Use single wall rigid Metal ductwork only.
  • Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape. Zephyr-ZPO-E36AS-Range-Hood-12

Some Ducting Options

Installation – Mounting the Range Hood

MOUNTING HEIGHTS

The range hood must be installed at a mini-mum height of 24 inches (61cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions remove the decorative mesh filters so that the range hood is easier to handle.

MOUNTING TO THE WALL

  1. Place the paper template included with your hood on the wall to determine where to add the screws for mounting the hood. Make sure the bottom of the template aligns with the bottom of where the hood will be located. See Fig. 9
  2. Lift the hood onto the screws and adjust to make sure the hood is level.
  3. When the hood has been adjusted tighten the screws to secure the hood in place.
    NOTE: Screws must be fastened into wooden studs so wood blocking may be necessary. If using wall anchors make sure to check your local codes for suitability and type of anchors to use.
    NOTE1: For the various installations use screws and screw anchors suited to the type of wall (minimum screw size: 1/4″ diameter x 2-3/4″ length).

Touch Control

Zephyr-ZPO-E36AS-Range-Hood-15

  • A – Lights Button : Lights are two level (high, low). From stand-by-on mode, touch once for high, twice for low, three times to cycle back.
  • B – Delay Off Button: Press the Delay Off Button to enable the ten-minute delay-off function, no matter at what speed the fan is running at. B button will start blinking indicating the delay off function is enabled. After ten minutes the fan and lights will turn off. Delay off function can be disabled by pressing B button, changing the speed, or pressing the Power Button C.
  • C – Power Button : Press once to activate all button stand by mode allowing control of other button functions. All buttons will illuminate indicating stand by mode. Press the Power Button again to turn the hood off (fan and lights). The stand by mode will remain active for 30 seconds.
  • D – Low Speed Button: In stand-by mode: Press once for low speed.
  • E – Medium Speed Button : In stand-by mode: Press once for medium speed
  •  F – High Speed Button: In stand-by mode: Press once for high speed.
  • MESH FILTER CLEAN REMINDER (always enabled): after 60 hours of fan usage, button A blinks when the hood is in stand-by, indicating it is time to clean the mesh filters. To Reset the function: with the hood in stand-by, press and hold the B button for 4 to 5 seconds, the A button will stop blinking, and the 60-hour timer will reset.
  • CHARCOAL FILTER REPLACE REMINDER (disabled by default, must be enabled by user if recirculating hood): To enable Charcoal Filter Replacement Function hold buttons D and F simultaneously for four seconds. The A button will quickly flash 3 times indicating the Charcoal Filter Replacement Function is enabled. After 200 hours of fan usage, the  button will blink while the hood is on, indicating it is time to replace the charcoal filters.
  • To Reset the Charcoal Filter Replace Reminder function: Hold the B button for 4 to 5 seconds until it stops flashing, and the 200-hour timer will reset.
  • Order replacement charcoal filter kit number Z0F-C011 through your local dealer, www.zephyronline.com, or the Zephyr customer service department.
  • To disable the Charcoal Filter Replacement function, repeat the enable procedure, the A button will illuminate for 3 seconds then turn off indicating the Charcoal Filter Replacement Function is disabled.

AIRFLOW CONTROL TECHNOLOGY

  • Airflow Control Technology (ACT™) enables the installer to reduce the maximum blower CFM to one of two most specified CFM levels; 390 or 290 CFM. The us-age of ACT may not be necessary for your installation. Please check your local codes for CFM restrictions

  • Setting ACT 390
    With the hood off, press buttons E and F simultaneously for approximately 3 seconds. The buttons will flash for 2 seconds to confirm the setting change. The hood will have 3 fan  speeds in ACT 390.

  • Setting ACT 290
    With the hood off, press buttons B and F simultaneously for approximately 3 seconds. The buttons will flash for 2 seconds to confirm the setting change. The hood will have 2 fan speeds in ACT 290.

  • Take care when reducing the CFM. After the ACT feature is set, it cannot be reverted to the default CFM.

Maintenance

  • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance.
  • The decorative mesh filters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use. In order to prevent a fire hazard, it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls. Clean the range hood by carrying out the following instructions:
  • Remove the filters from the range hood and wash them in a solution of water and neutral liquid detergent, leaving to soak.
  • Rinse thoroughly with warm water and leave to dry.
  • Filters may also be washed in the dishwasher at the lowest setting.
  • The filters may alter in color after several washes but is not cause for replacement.
  • Clean the blower and other surfaces of the range hood regularly using a cloth moistened with denatured alcohol or non abrasive liquid detergent.

Wiring Diagram

INTERNAL BLOWER CIRCUIT DIAGRAM

List of Parts and Accessories

DESCRIPTION HOOD PART#
REPLACEMENT PARTS
LED Light 1.3W (each) ZPO Z0B0051
**** ZPO-E30AS 50210051
**** ZPO-E36AS 50210045
OPTIONAL ACCESSORIES
Recirculating Kit ZPO ZRC-00PO
Replacement Charcoal Filters (2x) ZPO Z0F-C011
Duct Cover Extension, Stainless Steel ZPO Z1C-01PO
Remote Control ZPO 14000010

To order parts, visit us online at http://store.zephyronline.com

Zephyr-ZPO-E36AS-Range-Hood-18

Limited Warranty

  • TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS:
  • United States Customers please call: 1-888-880-8368 or contact us at: Canada Customers please call: 1-800-361-0799 or
  • Email: [email protected]
  • Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:
  • Two Year Limited Warranty for Parts: For two years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or replace parts before we elect to replace the Products.
  • One Year Limited Warranty for Labor: For one year from the date of your original purchase of the Products, we will provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to manufacturing defects subject to the exclusions and limitations below. After the first year from the date of your original purchase, you are responsible for all labor costs associated with this warranty.
  • Warranty Exclusions: This warranty covers only repair or replacement, at our option, of defective Products or parts and does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and service required for the Products and consumable parts such as fluorescent, incandescent or halogen light bulbs, mesh and charcoal filters and fuses; (b) any Products or parts which have been subject to freight damage, misuse, negligence, accident, faulty installation or installation contrary to recommended installation instructions, improper maintenance or repair (other than by us); (c) commercial or government use of the Products or use otherwise inconsistent with its intended purpose; (d) natural wear of the finish of the Products or wear caused by improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service trips to your home to teach you how to use the Products; (g) damage to the Products caused by accident, fire, floods, acts of God; or (h) Custom installations or alterations that impact serviceability of the Products. If you are outside our service area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service.
  • Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUEN-TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF
  • THE PRODUCTS. THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL OTHER EXPRESS WARRANTIES FOR THE PRODUCTS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES IMPLIED BY LAW, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
  • Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the same two-year and one-year periods described above if permitted by applicable law. Any oral or written description of the Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty. Prior to using, implementing or permitting use of the Products, you shall determine the suitability of the
  • Products for the intended use, and you shall assume all risk and liability whatsoever in connection with such determination. We reserve the right to use functionally equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty service. This warranty is not transferable from the original purchaser and only applies to the consumer residence where the Product was originally installed located in the United States and Canada. This warranty is not extended to resellers.
  • To Obtain Service Under Limited Warranty : To qualify for warranty service, you must: (a) notify us at the address or telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and serial number; and (c) describe the nature of any defect in the Product or part. At the time of the request for warranty service, you must present evidence of your proof of purchase and proof of the original purchase date. If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, you will be responsible for all shipping, travel, labor and other costs related to the services. This warranty is not extended or restarted upon warranty repair or replacements.
  • Please check our website for any additional Product information, www.zephyronline.com.
    • Zephyr, 2277 Harbor Bay Parkway, Alameda, CA 94502
    • JAN21.0401

PRODUCT REGISTRATION

  • Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration
  • IT’S IMPORTANT
  • Prompt registration helps in more ways than one.
    • Ensures warranty coverage should you need service.
    • Ownership verification for insurance purposes.
    • Notification of product changes or recalls.Zephyr-ZPO-E36AS-Range-Hood-194
  • Zephyr Ventilation
  • 2277 Harbor Bay Pkwy.
  • Alameda, CA 94502
  • 1.888.880.8368

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ZEPHYR User Manuals

Related Manuals