Brink 310681 Sky Renovent Instructions
- June 16, 2024
- BRINK
Table of Contents
Renovent Sky 300
Set/ Satz/ Set/ Kit : 310681
310681 Sky Renovent
Replacing preheater
Important: Mounting a preheater is always possible at a Renovent Sky 300!
– Switch off the main power from the Renovent Sky 300.
– Position the preheater so that the arrow does point to the appliance and
place it on the duct “From atmosphere”.
– Connect the wiring of the preheater as shown on the wiring diagram on page 2
is displayed.
– Turn on the power of the Renovent Sky 300 as well as the preheater.
– Parameter 12 must be changed to 1.
I = | To dwelling | |
---|---|---|
II = | To atmosphere | |
III = | From dwelling | |
IV = | From atmosphere | |
Parameter | Description | Factory setting |
--- | --- | --- |
12 | Heater | 0 |
1 = Preheater
Wiring diagramy
Renovent Sky 300
A | Renovent Sky 300 |
---|---|
B | Connector for conneting preheater on the Renovent Sky 300 |
C | Heating coil ( 1000W max.) |
D | Maximum safety with manual reset |
E | LED maximum safety; lights up when activated |
F | By installer on the Renovent Sky to join connector B |
G | Wiring in preheater |
C1 | brown |
--- | --- |
C2 | blue |
C3 | green/yellow |
C4 | black |
Technical information
- Supply voltage
- Weight
- Duct diameter
- Heater length
- Overall length
- Protection degree
- Rated power
- Rated current
Service
When ordering parts, in addition to the article code number, please state the type of the heat recovery appliance, the serial number, the year of production and the name of the part.
Maximum safety
Heating coil
Cable with plug 230V
Air for Life
Wethouder Wassebaliestraat 8 7951 SN Staphorst The Netherlands
P. O. Box 11 NL-7950 AA Staphorst The Netherlands
T. +31 (0) 522 46 99 44
F. +31 (0) 522 46 94 00
info@brinkclimatesystems.nl
www.brinkclimatesystems.nl