Solaira SMaRT 34-DV Variable Controller User Manual
- June 16, 2024
- Solaira
Table of Contents
Solaira SMaRT 34-DV Variable Controller
Use the following table to aid in setting up
Fahrenheit | Celsius |
---|---|
32.0 | 0.0 |
36.0 | 2.2 |
40.0 | 4.4 |
45.0 | 7.2 |
50.0 | 10.0 |
55.0 | 12.8 |
60.0 | 15.6 |
65.0 | 18.3 |
70.0 | 21.1 |
75.0 | 23.9 |
80.0 | 26.7 |
Optional Accessories (Sold Separately)
The SMaRT-34DV can be used with the following approved accessories. The use of any other control interface is not recommended.
WARNING: Use of standalone Solaira SMRTOCC40 and SMRTOCC60 are for
standalone controls ONLY and may not be paired with SMaRT34-DV.
FAILURE TO COMPLY MAY RESULT IN CONTROLLER DAMAGES.
FAQ
- Q: Can I install the Solaira SMaRT 34-DV Variable Control myself?
- A: No, the Solaira SMaRT 34-DV Variable Control is a high-power electrical device and MUST ONLY BE INSTALLED BY A CERTIFIED ELECTRICIAN TO LOCAL AND NATIONAL ELECTRICAL CODE.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
SAFETY WARNING ALL INSTALLATIONS/SERVICES MUST ONLY BE PERFORMED BY A
LICENSED/CERTIFIED ELECTRICIAN TO THE LOCAL AND NATIONAL ELECTRICAL CODE
(NEC).
WARNING: SHOCK AND FIRE HAZARD:
- Serious injury or death could occur
- Disconnect ALL power sources before removing the cover. Power should only be re-connected after electrical installations are complete and the cover replaced
- Be certain the power source conforms to the specifications outlined on the heater label
- Maximum heater load SHOULD NOT EXCEED 34 AMPERE
- Control MUST BE PROPERLY grounded. Assure to connect ground wire green wire from the heater to the ground connection from the electrical supply, not to a live or “hot” conductor.
- Engineer/Electrician/Installer to determine the suitability of this appliance in the intended application and compliance with all local, state/provincial and National Electrical Code (NEC) requirements.
- Do not use locations containing hazardous or explosive atmospheres.
ELECTRICAL RATING
- Maximum load 34A @110-120V or 208-240VAC 50/60HZ
WARNING SERIOUS INJURY OR DEATH COULD OCCUR, DISCONNECT ALL POWER BEFORE SERVICE.
INTRODUCTION
The Solaira SMaRT 34-DV Control has a 1 to 5-step setting allowing you to find the optimum comfort setting in your specific area.
- To increase output to full output, press and release the red button.
- To increase in increments, press and hold the red button until the desired number is reached.
- To reduce output to OFF, press and release the red button.
- To reduce in increments, press and hold the red button until the desired number is reached
FEATURES
- Variably control your Solaira° heaters, up to a max load of 34A.
- Weatherproof control for exposed, wet conditions (it is the electrician’s responsibility to ensure correct water-tight connection, this may necessitate replacing included watertight strain relief)
- Variable Control – Ability to adjust output to desired comfort level
- Soft Start – zero current switching point which can extend emitter lamp life
- Temperature Monitoring – Solaira SMaRT 34-DV Variable control is equipped with a local (on controller) temperature monitor. This will allow a user to pre-set the minimum temperature level that will allow the controller to operate.
Note: the temperature monitor is calibrated in Celsius; please use the following table to aid in setting up:
OPTIONAL ACCESSORIES (Sold Separately)
WARNING: The SMaRT-34DV can be used with the following approved
accessories. The use of any other control interface is not recommended.
-
Handheld IR Remote (SMRTVMT): This is an optional handheld remote that communicates via IR to either the SMaRT Controller or Optional Wall Switch (SM-WSD). Must be in the line of sight of the controller.
-
Wall Switch (SM-WSD): This is a mounted wall switch unit that provides control of the SMaRT-34DV, which may be remotely located. The remote-control wall switch unit is supplied mounted on a single gang faceplate, ready to be fitted to a single gang certified J-box. As supplied the unit must be installed indoors in a dry environment, if the unit needs to be installed outdoors or in a wet environment it must be installed onto a certified J-box, which is itself installed inside a water-resistant, IP65-rated enclosure and to all appropriate local and NEC codes. The SM-WSD can also interface with the Handheld IR Remote SMRTVMT,
which must be in the line of sight of the SM-WSD. -
Occupancy Sensor (SMRTOCC): A passive infrared (PIR) external sensor, with a range of approximately 12m, can monitor the selected area ensuring heaters only switch on when the zone is occupied.
-
Remote Temperature Monitor (SMRTVTEM-R): The controller can be equipped with a remotely located temperature sensor that monitors the temperature of the desired zone and inhibits the heaters when the temperature exceeds a pre-determined set point of between 41°F (5°C) to 77°F (25°C).
WARNING: Use of standalone Solaira SMRTOCC40 and SMRTOCC60 are for
standalone controls ONLY and may not be paired with SMaRT34-DV. FAILURE TO
COMPLY MAY RESULT IN CONTROLLER DAMAGES.
WARNING: Solaira SMaRT 34-DV Variable control is a high-power electrical
device and MUST ONLY BE INSTALLED BY A CERTIFIED ELECTRICIAN TO LOCAL AND
NATIONAL ELECTRICAL CODE.
INSTALLATION
- The control can be installed in a convenient VENTED location and does not have to be installed in the immediate area of the heaters. The unit is shipped with the Occupancy sensor input fitted with a wire link which continually re-triggers the “ON” timer so that it never expires.
- If the user decides to utilize the optional Occupancy Sensor (Sold Separately), the occupancy monitor should be mounted 8’ (2.5 + Meters) above of the floor. Ceiling mounting is preferred but not essential. The optional Occupancy Sensor must not be mounted directly in line with the heater’s output, highly reflective surfaces, radiators or other thermostatically controlled heaters or open doorways with people walking past.
WARNING: CONTROLLER MOUNTING
DO NOT mount the controller directly on any flammable material i.e. wood or
any other combustible. The controller must be mounted via standoffs (supplied
& specified by others) to aid in heat dissipation, as per local building and
NEC code.
INITIAL START-UP WITH OPTIONAL OCCUPANCY SENSOR
- Occupancy Sensor (SMRTOCC) (sold separately), it takes 60 seconds to set before detection takes place
- The optional Occupancy Sensor continues to monitor the area and will reset to the set time every time it detects movement.
- Before testing ensure the wiring is correct.
- The temperature trip point has already been pre-set at the factory.
- The timer is preset to 1 minute but can be adjusted using a timer trimmer potentiometer to 1-60 minutes.
- The expected detection area can now be “walked tested” using the diagram shown in mind. The area should be crossed in various directions to ensure coverage is as expected.
DISPLAY FEATURES
TROUBLESHOOTING
- The heater does not come on, t in display….The heater pre-set trip temperature IS ABOVE THE AMBIENT
- TEMPERATURE. This can be adjusted using the temperature set point potentiometer.
- The heater does not come on, flashing DOT…The controller is waiting for input from the optional occupancy sensor. If your system does not utilize the occupancy sensor, then the wire jumper (factory installed) must be in place in PIR SENSOR INPUT on pins SIG IN and COM. If the jumper is not in place, the controller will not operate.
SPECIFICATIONS
- Max load at 20°C ambient: 34 Amp, 8000W @ 208-240VAC or 4000W @ 120VAC
- Voltage: 120Vac or 208-240Vac +/- 10%,50/60Hz
- Power Consumption: 50mA
- Occupancy Sensor (option): See below
- Pushbutton Timer (option): Momentary or Toggle
- Set Period: 1-60 minutes
- Temperature Setpoint: 5°C to 25°C
- Factory Set Temperature trip point: 25°C
- 2 heater Installation: Must be fitted in Parallel
- Ambient Operating Temperature: -20°C to 30°C
- IP Rating: IP65
- Max Unit Operating Temperature: 65°C
- Occupancy Monitor (optional): 12V dc
- Operating Voltage: 90° Adjustable
- Direction: 45’ (18 Meters)
- Detection:
WARNING: Solaira SMaRT 34-DV Variable control is a high-power electrical device and MUST ONLY BE INSTALLED BY A CERTIFIED ELECTRICIAN TO LOCAL AND NATIONAL ELECTRICAL CODE.
WIRING DIAGRAM
SMaRT 34-DV ILLUSTRATIVE WIRING DIAGRAM
The connection diagram is for illustrative purposes only. Installation must be
carried out by a certified electrician to local, state/provincial and National
Electric Code (NEC) requirements. Inforesight Consumer Products Inc. assumes
no responsibility for the heaters or controller electrical plan or
installation
WARNING SERIOUS INJURY OR DEATH COULD OCCUR, DISCONNECT ALL POWER BEFORE SERVICE
- WARNING: RISK OF INJURY OR DEATH ENSURE ALL POWER IS OFF FOR INSTALLATION OR SERVICE
- ALL SOLAIRA HEATERS AND CONTROLLERS SHOULD BE INSTALLED BY CERTIFIED ELECTRICIANS TO LOCAL STATE/PROVINCE NEC CODE
TROUBLE SHOOTING
LIMITATION OF LIABILITY
It is understood and agreed that the seller’s liability whether in contract,
in tort, under any warranty, in negligence or otherwise shall not exceed the
return of the amount of the purchase price paid by the purchaser and under no
circumstances shall the seller be liable for special, indirect or
consequential damages. The price stated for the equipment is a consideration
in limiting the seller’s liability. No action, regardless of form, arising out
of the transactions may be brought by the purchaser more than one year after
the cause of action has accrued.
WARRANTY
- SOLAIRA CONTROL products are guaranteed to be free from mechanical and electrical defects for one year from the date of shipment under normal use and service provided installation is made under manufacturers’ recommendations.
- Parts deemed defective shall be repaired or replaced at the manufacturer’s option and the manufacturer’s expense but shall not include foreign or federal excise taxes, state or municipal sale or use taxes, and all such taxes not limited to the foregoing being the responsibility of the purchaser.
- No charge for travel and/or mileage will be allowed to the purchaser.
- SOLAIRA reserves the right to make changes in design or make any improvements to any products. The right is always reserved to modify our equipment because of new technology, underwriter’s requirements and/or government regulations.
- The following are not covered under warranty:
- INSTALLATION OF CONTROL BY NON-CERTIFIED ELECTRICIAN.
- Failure from neglect, abuse, careless handling and misapplication of unit.
- Failure to observe guidelines for installation or improper voltage hook-up.
- Failure caused by improper installation and not following local, state/provincial and federal electrical guidelines
- Unless specifically allowed by SOLAIRA CONTROLS, no other charges may be included under warranty.
Notice: Inforesight Consumer Products Inc. website, product information and products can be accessed from Canada and other countries around the world.
The customer understands that some or all products provided by Inforesight
Consumer Products Inc. may not be available for purchase or installation in
certain jurisdictions or geographical areas. Inforesight Consumer Products
Inc. reserves the right, in its sole discretion, to exclude or otherwise limit
the provision of any product to a person or entity residing in any
jurisdiction or geographical area outside of Canada. Inforesight Consumer
Products Inc. provides general product information, installation guidelines
and procedures and Customer understands that Customer is solely and
exclusively responsible for the installation of the product and ascertaining
all applicable local municipal, provincial, state, and federal NEC (National
Electrical Code) rules, by-law, ordinances and guidelines applicable to the
installation of any Inforesight Consumer Products Inc. products. Customers
must strictly adhere to and be compliant with the local rules, laws,
ordinances and legal requirements for the safe installation and use of any
Inforesight Consumer Products Inc. products. Instruction manuals are included
with the product packaging and copies of our instruction manuals are available
upon request. Under no circumstances shall Inforesight Consumer Products Inc.
or its affiliated entities, employees, agents, shareholders, officers or
directors be liable to Customer or any third party for any product
installations and Customer releases Inforesight Consumer Products Inc. from
all losses, death, personal injury, property damage, other damages, rights,
claims, demands and actions of any kind arising from the Customer’s
installation and use of the product, whether the installation was or was not
in accord with the provided instruction manual and/or in compliance with
applicable local laws.
Due to ongoing product improvements, specifications and dimensions are subject
to change without notice and without incurring obligations.
CONTACT
- Solaira°™ is a registered trademark of Inforesight Consumer Products Inc.
- 125 Traders Blvd. # 4, Mississauga, Ontario, Canada, M4Z 2H3
- Tel: 905-568-7655, EXT 23 SERVICE, Fax:905-568-7521
- info@solairaheaters.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>