ELEGOO PHECDA Laser Engraver Limit Switch Installation Guide
- June 16, 2024
- ELEGOO
Table of Contents
PHECDA laser engraver limit switch installation guide
Instructions for use:
This limit switch installation guide is only suitable for users who can 3D print the limit switch printed parts. Use the print files provided by ELEGOO, you must use the limit switches shown in the following picture.
Material list
X-axis limit switch printed part,download link:
https://drive.google.com/file/d/193AMYL0baBkOGaarZtu4bTabPZLMSriz/view?usp=sharing
Y-axis limit switch printed part,download link:
https://drive.google.com/file/d/1CSkMJcE6RMgEcmc_w9MLDWho-
t7GGrFG/view?usp=sharing
Limit Switch x2
15cm XH2.54 3P cable x1
140cm XH2.54 3P cable x1
Cable tie x5
PM38 screw x1
M36 self-tapping screw x2
Installation Method
-
Install the Y-axis limit switch to the printed part.
Pass the cable of the limit switch through the bottom gap of the main board.
Then push the Y-axis limit switch printed part in and snap it onto the screw pillars of the motherboard. Plug the cable into the “Y-” port. As shown below.
-
Install the X-axis limit switch
Use two M36 self-tapping screws to install the limit switch on the printed part.
Install the 3P cable on the machine and secure the cable with cable ties at the red arrows.
Connect the cable to the “X-” port on the main board.
Then connect the cable to the limit switch and remove the screw that secure the air filter device.
Secure the printed part on one side to the V-wheel track, and use a PM38 screw to fix the other side.
Software Parameter Settings
-
Setting of limit switch parameters in LaserGRBL.
Open the LaserGRBL software, select the correct port number, baud rate, and click the Connect button. (the red arrow indicates the Connect button).
Click “Grbl” button on the toolbar, then click “Grbl Configuration”
The software will pop up a window as shown in the picture below.
Change the value of $5 in the red box to “0”, and change the values of $21 as well as $22 to “1” respectively. After the modification is completed, click “Write”, it will display “Config written successfully” and you can close the window.
-
Setting of limit switch parameters in Lightburn.
Open the Lightburn software and select the correct com number to connect to the engraver machine.
Click “Edit” on the toolbar and select “Machine Settings”. As shown in the picture below.
Change $21 and $22 to True respectively. Click “Outputs setup” to open the complete setup window. Change $5 to False. Click Write and then click OK to complete the parameter settings.