GOK FA 99 Caramatic Connect Clean Wartung Filterpatrone Instruction Manual
- June 13, 2024
- GOK
Table of Contents
Assembly instructions
Please keep these instructions in the vehicle!
Caramatic Connect Clean – gas filter type FA 99 for filtering the gaseous phase
MAINTENANCE Filter cartridge
Clean the filter cup and replace the filter element:
Danger of explosion and burning due to opened gas cylinder(s)!
-
Can cause explosions. Severe burns in case of direct skin contact.
-
Close the gas cylinder valve(s) before opening the gas filter!
-
Wear protective clothing, especially gloves!
-
Keep ignition sources or electrical objects out of reach!
-
Keep the piping in a gas free state or ventilate it using the gas equipment!
-
Close the gas supply!
-
Loosen and unscrew the filter cup 1 by hand 7 with the screw aid.
-
Do not damage 1 the filter cup, replace if necessary.
-
Wear gloves!
-
Wipe away the collected oil and dirt in the filter cup 1 with a cloth.
-
Unscrew the filter cartridge 2 by hand and pull the filter element 5 off the supporting core 9.
-
Clean the 3 0-ring with cleaning agent.
-
Dispose of the filter element 5 cloth and cloves (hazardous waste!).
-
Place the new filter element 5 on the supporting core 9 by hand and screw in the filter cartridge 2 by hand.
-
Position the 1 filter cup and screw in by hand, then tighten with 7 the screw aid (max. 5 Nm).
NOTICE
The O-ring 3 must sit directly in the mounting and be free of dirt.
-
Tighten the inlet and outlet connection if applicable.
-
Open the gas cylinder valve and perform LEAK TESTING!
Here, also check the leak-tightness between the filter housing and filter cup! -
The filter cartridge is suitable for gas filter type FA 99 and type AS99.
-
We recommend servicing the filter cup and filter cartridge every year.
CAUTION
Risk of burning or fire!
Serious burns to the skin or damage to property.
• Do not use an open flame to check for leaks.
Before start-up, check the product connections for leak-tightness.
- Close all shut-off fittings on the connected Consumer equipment.
- Slowly open the withdrawal valve or the gas cylinder valve.
- If there is a safety device (e.g. SBS, EFV) connected to the connected Consumer equipment, open this during leak testing.
- Spray all connections with a foam producing substance according to EN 14291 (e.g. leak spray, item no. 02 601 00).
- Bubbles will form in the foam producing substance if there are any leaks.
NOTICE
If more bubbles form, re-tighten the connections.
If the leaks cannot be repaired, the product must not be used and must be
replaced.
START-UP
After the product has been ASSEMBED and LEAK TESTING has been carried out successfully, it is immediately ready for operation.
OPERATION
- Use this product only when you have carefully read the assembly and operating manual.
- For your own safety, observe all the safety notes in this assembly and operating manual.
- Please also consider the safety of others.
DISPOSAL
To protect the environment, our products may not be disposed of along
withhousehold waste.
The product must be disposed of via a local collection station or a recycling
station.
Artikel-Nr. 71 817 51 Originalanleitung -DE-/ Ausgabe 12.2022
Regler- und Armaturen-Gesellschaft mbH & Co. KG
Obernbreiter Straße 2 – 18 97340 Marktbreit/ Germany
Telefon: 09332 404-0 Telefax: 09332 404-49
E-Mail: info@gok.de Internet:
www.gok.de www.gok-blog.de
References
- GOK-Blog - Flüssiggas und flüssige Medien sicher nutzen
- GOK Germany ► Regulators and armatures | GOK
Read User Manual Online (PDF format)