Karibu 80414 Sauna Control Instruction Manual
- June 16, 2024
- Karibu
Table of Contents
- 80414 Sauna Control
- Items supplied
- Technical data
- Explanation of symbols
- General information and instructionson sauna usage
- General safety instructions
- Mounting the control unit on a wall
- Control units – versions
- Fitting the sensor
- Sauna Control FIN connection diagram
- Starting – operation – displays
- Display mode – Time / Temperature
- Error messages
- Explosionszeichnung Sauna Control FIN
- Installation Steuerung Plug and Play
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Sauna Control
Installation and Operating Instructions
80414 Sauna Control
Sauna Control FIN
Artikelnummer 80414 (37.470.01)
Sauna Control FIN P&P
Artikelnummer 5635 (37.470.02)
(Nur Temperatursteuerung)
Sauna Control BIO
Artikelnummer 80416 (37.470.11)
Sauna Control BIO P&P
Artikelnummer 5630 (37.470.12)
(Temperatur und Feuchtesteuerung)
Items supplied
(Subject to technical changes)
The control unit consists of the following components as supplied:
- Control unit with operation panel and integrated load unit
- Sensor with heater sensor and thermal fuse
- Sensor with temperature sensor / humidity sensor
- 2 sensor cases
- 1 silicone sensor cable, 3/4-stranded, with an approx. length of 5 meters
- Assembly bag (three 4 x 40 mm screws and four 3 x 30 mm screws)
Technical data
Housing dimensions | Width 235 mm – height 195 mm – Depth 75 mm |
---|---|
Operation | Touchpad – touch control |
Display 4 | sections of 15 mm x 30 mm each |
Protection | IPX4 |
Rated voltage | 400 V ~ 3 N PE |
Switching power in Finnish mode | Maximum 10.8 kW ohmic load (AC1 operation) |
Switching power in humidity mode | Maximum 9.3 kW plus 1.5 kW for the bio |
evaporator unit
Control range for Finnish mode| 5° to 100° Celsius – 5° adjustment
Control range for bio mode| 5° to 70° Celsius – 5° adjustment units
Heater sensor limit| 125° Celsius (heater sensor no. 1)
Temperature limit| 140° Celsius (heater sensor no. 1)
Temperature indicator| Maximum 110° Celsius (RAL point sensor no. 2)
Humidity control| Measurement by humidity sensor – actual measurement
Heat cycle limit| 240 minutes or 4 hours
Lighting| Maximum 60 W – dimmable 10% adjustment units
Ambient temperatures| -15° to plus 40° Celsius
Ou tdoors| Protective enclosure required (splash proof)
Explanation of symbols
Information!
This provides the user with useful information and tips about how to operate
and use the sauna system (sauna cabin, sauna heater and sauna controller)!
Warning!
Danger!
Warnings about possible dangers or dangerous situations which could even lead
to loss of life!
Caution!
Instructions or warnings which could lead to defects or damage to components
if not observed.
Electrical voltage!
Warns about voltage and high voltage! Failure to observe this warning may
result in an electric shock.
General information and instructionson sauna usage
4.1 – Sauna cabin – sauna heater – sauna controller
The FIN and BIO control units are an integral part of a well-functioning sauna
cabin, as long as all the necessary condition s are properly met.
A control unit can only work to optimum effect in combination with a suitable
sauna heater if the electrical connections from the main distributor to the
control unit and from the control unit to the sauna heater havebeen installed
correctly and professionally
in accordance with our circuit diagrams and specifi cations using the materials
intendedfor the purpose.
Faults on the control unit may also be causedby insuffi cient incoming air or
insuffi cient ventilation of the sauna heater, as well as bya lack or waste air
vents or waste air vents that are too small when the sauna is
usedcontinuously. In this connection, please
refer to and observe our “Information sheet”which is also included.
With regard to the temperature and humiditysettings, discrepancies between the
set and displayed temperature and humidityare possible. This can be explained
by the fact that the mechanical display units are generally installed on the
inside wall of the
sauna. The temperature of the sauna wall, however, is always lower than that
of theactual air temperature in the cabin. The displayed humidity levels can
be incorrect at the start for as long as the cabin has not heated up enough to
a suffi cient temperature.
General safety instructions
5.1 – Proper use
The FIN and BIO control units are designed only for use for the control of
sauna heaters with a maximum output of up to 10.80 kW. The FIN control unit is
for sauna heaters with Finnish mode (temperature control only) and the BIO
control unit can be used
for bio mode (temperature and humidity).
The control unit is designed to be used in sauna cabins which are suitable for
the purpose! The control unit is only suitable for the operation of approved
sauna heaters and in sauna cabins which are suitable for the purpose.
The control units are designed for operation in private households only!
Any claims for compensation for damages arising out of or in connection with
improper use are excluded.
The user or operator will be exclusively responsible for any damages resulting
from such improper use.
5.2 – Installation and electrical connection
The control units must be correctly installed in accordance with the supplied
installation instructions and connected up to the electricity supply in
accordance with the enclosed circuit diagram.
Only a qualifi ed electrician or an electrical contractor may make the
electrical connection from the main distributor in the residential building to
the control unit and from the control unit to the sauna heater.
The system must be fi tted with a separate residual current device circuit-
breaker (earth leakage circuit breaker 40A 30mA).
Refer to the safety actions required by VDE 100 Section 49 DA/6 and VDE 0100
Part 703/11.82 Section 4.
5.3 – Dangers from electrical voltage
Contact with live parts may lead topotentially fatal injuries.
Before any work on the system or the installation is started, the power supply
tothe control unit must be disconnected and measures taken to secure it to
prevent itfrom being switched on again.
5.4 – Requirements to be met by the operator
Only people over the age of 18 are allowed to use and operate this control
unit and the sauna heater connected to it. People withphysical handicaps are
only allowed tooperate the control unit under supervision.
Before starting, the person doing the operating must ensure that there are
absolutely no combustible objects (towels, bathrobes, etc.) on or beneath the
sauna heater, or stored in the vicinity of the sauna heater.
5.5 – Alterations and modifi cations
Alterations and modifi cations to the control units and/or the wiring or to the
electrical connections could lead to unforeseeable dangers! Alterations to any
part of the complete system are prohibited!
5.6 – Safety and dangers
Read the operating instructions carefully before starting the work of fi tting
and installation and observe all information and instructions on potential
dangers.
It is essential that the safety instructions provided here and the additional
instructions provided in the following chapters are observed, in order to
reduce risks to healthand avoid dangerous situations. Improper operation could
lead to serious injuries.
5.7 – General safety information
This equipment can be used by children of8 years and older and by people with
limited physical, sensory or mental capacities or those with no experience or
knowledge
if they are supervised or have received instruction in how to use the
equipment safely and understand the dangers which result from such use.
Children are not allowed to play with the equipment. Unless supervised,
children are not allowed to clean the equipment or carry out user-level
maintenance work.
If permanently installed equipment is not equipped with a power cable and a
plug or other means of disconnecting from the mains power supply with a
contact opening on each pole in accordance with the conditions of overvoltage
category III for complete disconnection, it is a requirement that the
instructions must specify that a disconnecting device of this type must be
incorporated into the permanently installed electrical installation according
to the installation regulations.
The instructions for permanently installed equipment must specify how the
equipment has to be fastened to the surface to which it is to be fastened. The
method used must not involve the use of adhesives, because these are not
considered to be a reliable means of fastening.
If the insulation is damaged, switch off the power supply immediately and
arrange for it to be repaired by a specialist contractor.
Work on electrical equipment may only be carried out by a professional!
Never bypass any fuses or deactivate them.
Check the rating data whenever a fuse needs to be replaced. Protect the
control units against moisture.
The controller housing may only be opened by a professional.
Objects on the sauna heater or in the vicinity of the sauna heater could cause
a fi re and lead to injuries.
Keep children away from the controller and the sauna heater.
Covering over the temperature and humidity sensors or placing them in the
wrong position could lead to higher temperatures and could therefore cause a fi
re.
Make sure that there is suffi cient air circulation in and around the entire
sauna cabin.
Mounting the control unit on a wall
Control units – versions
Version for Finnish mode (temperature)
Version for Finnish and BIO mode (temperature + humidity)
Fitting the sensor
View from above – Sauna cabins up to approx. 7.99 m³ in sizeView from above – Sauna cabins larger than 8 m³ in size![Karibu 80414 Sauna Control
- Fitting the sensor 1](https://manuals.plus/wp- content/uploads/2024/01/Karibu-80414-Sauna-Control-Fitting-the-sensor-1.jpg)
Sauna Control FIN connection diagram
Technical support: saunaservice@isc-gmbh.info 9.1 – Sauna Control BIO connection diagram
Technical support: saunaservice@isc-gmbh.info
9.2 – Sauna Control FIN P &P connection diagram
- llumination / light
- Mains connection
- Heater connection
- Sensor 1
- Sensor 2
** 9.3 – Sauna Control BIO P &P connection diagram**
- llumination / light
- Mains connection
- Heater connection
- Sensor 1
- Sensor 2
Starting – operation – displays
10.1 – Turning the control unit on with the main switch
To preset the values you simply have to lightly tap the fi elds marked with the
- and – symbols! Turn on the main switch!
Values can be adjusted in both directions (+ and -).
Adjusting the lightingAdjusting the start/stop funct Setting Actuate the + and – buttons at the same time with your index fi nger and middle fi nger
- und – Taste gleichzeitigSetting the temperatureSetting higher than 70° – Humidity
indicator “OFF”
Sauna temperature higher than 70° – Humidity indicator “OFF” Setting the humidity level Bio/humidity mode is only possible up to a temperature of 70° Celsius!A buzzing signal will sound if there is insuffi cient water.
The evaporator switches off automatically after 1 minute.
The indicator switches to 000 – a restart is required
Display mode – Time / Temperature
Indicator fl ashes – the control unit is in standby mode
LED illuminated – the control unit is in heating mode
Indicator fl ashes after heating mode – the control unit is in standby mode
(switches off after 240 minutes)
Temperature
Temperature setting can be adjusted from 5° to 100° with the + or – button (5°
steps)
Temperature preselection 85° – indicator fl ashes for 5 seconds
Indicator switches to the actual temperature in the cabin – LED illuminated /
heating mode is active
Temperature reached – LED is off / heating mode is inactive
Humidity
Indicator shows 000, evaporator is not in operation
Indicator fl ashes and switches to the actual value after 5 seconds, LED
illuminated, evaporator in heating mode!
Preset humidity reached, LED off, evaporator mode is in standby mode
1. Temperature is set to over 70°, evaporator will be switched off by the
system
2. Evaporator is switched off (insuffi cient water)
Lighting
Indicator “000”, lighting is switched off, LED off
The lighting can be adjusted in steps of 10%, from 50% to 100% luminosity
Indicator fl ashes for 5 seconds and then lights up
LED illuminated, lighting is switched on
11.1 – Humidity – temperature diagram
Error messages
Temperature sensor (sensor 1) on heater has no contact or is not properly
connected
Thermal fuse (sensor 1) on heater has no contact or is not properly connected
Temperature sensor (sensor 2) at RAL point has no contact or is not properly
connected (2 connections)
Humidity sensor (sensor 2) at RAL point has no contact or is not properly
connected (2 connections)
When the evaporator is switched on, it is not possible to set any of the
values and the indicator fl ashes and shows “OFF”!
The water shortage terminal (water shortage indicator) is not connected!
Explosionszeichnung Sauna Control FIN
Sauna Control FIN
Art.-Nr. 37.470.01
I. Nr. 1801213.1 – Stückliste Sauna Control FIN
Sauna Control FIN -Artikelnummer 37.470.01 – I. Nr. 18012
Pos.| E-Nummer| Description| Stuck
1| 086.50.010.21| Operation panel| 1
2| 086.50.010.22| Top housing| 1
3| 086.50.010.23| PCB for operation| 1
4| 086.50.010.24| PCB for power| 1
5| 086.50.010.25| Ground connection block| 1
6| 086.50.010.26| Cable for switch (blue)| 1
7| 086.50.010.27| Cable for switch (brown)| 1
8| 086.50.010.28| Power switch| 1
9| 086.50.010.29| Bottom housing| 1
10| 086.50.010.30| Screw 4 x 25| 3
11| 086.50.010.31| Shield sleeve| 5
12| 086.50.010.32| Cable for PCB connection| 1
13| 086.50.010.33| Sensor RAL-Point| 1
14| 086.50.010.34| Sensor – Oven| 1
15| 086.50.010.35| Sensor cover| 2
16| 086.50.010.36| Screw 4 x 15| 4
17| 086.50.010.37| Cable for sensors – 3-lines| 5 mtr.
13.2 – Explosionszeichnung Sauna Control BIO
Sauna Control BIO
Art.-Nr. 37.470.11
I. Nr.: 18012 13.3 – Stückliste Sauna Control BIO
Sauna Control BIO -Artikelnummer 37.470.11 – I. Nr. 18012
Pos.| E-Nummer| Description| Stuck
1| 086.50.010.38| Operation panel| 1
2| 086.50.010.22| Top housing| 1
3| 086.50.010.39| PCB for operation| 1
4| 086.50.010.40| PCB for power| 1
5| 086.50.010.25| Ground connection block| 1
6| 086.50.010.26| Cable for switch (blue)| 1
7| 086.50.010.27| Cable for switch (brown)| 1
8| 086.50.010.28| Power switch| 1
9| 086.50.010.29| Bottom housing| 1
10| 086.50.010.30| Screw 4 x 25| 3
11| 086.50.010.31| Shield sleeve| 5
12| 086.50.010.32| Cable for PCB connection| 1
13| 086.50.010.41| Sensor Temperature/Humidity| 1
14| 086.50.010.34| Sensor Oven| 1
15| 086.50.010.35| Sensor cover| 2
16| 086.50.010.36| Screw 4 x 15| 4
17| 086.50.010.42| Cable for sensors – 4-lines| 5 mtr.
13.4 – Explosionszeichnung Sauna Control FIN P &P
Sauna Control FIN P & P
Art.-Nr. 37.470.02
I. Nr.: 19011 13.5 – Stückliste Sauna Control FIN P &P
Sauna Control FIN P &P
Position| Artikel nummer| Description| Menge
1| 086.50.010.46| Top housing| 1
2| 086.50.010.23| PCB for operation| 1
3| 086.50.010.47| PCB for power| 1
4| 086.50.010.26| Cable for switch(blue)| 1
5| 086.50.010.27| Cable for switch(brown)| 1
6| 086.50.010.28| Power switch| 1
7| 086.50.010.48| Bottom housing| 1
8| 086.50.010.30| Screw 4 x 25 mm| 3
9| 086.50.010.32| Cable for PCB connection| 1
10| 086.50.010.33| Sensor RAL-Point| 1
11| 086.50.010.34| Sensor Oven| 1
12| 086.50.010.35| Sensor cover| 2
13| 086.50.010.36| Screw 4 x 15 mm| 4
14| 086.50.010.49| Sensor plug for RAL-Point| 1
15| 086.50.010.50| Sensor plug for oven| 1
16| 086.50.010.42| Cable for sensors -4-lines (5 mtr.)| 1
17| 086.50.010.51| Plug for power| 1
18| 086.50.010.52| Plug for light| 1
13.6 – Explosionszeichnung Sauna Control BIO P &P
Sauna Control BIO P & P
Art.-Nr. 37.470.12
I. Nr.: 19011 13.7 – Stückliste Sauna Control BIO P &P
Sauna Control BIO P &P
POS.| Artikel nummer| Description| Menge
1| 086.50.010.53| Top housing| 1
2| 086.50.010.39| PCB for operation| 1
3| 086.50.010.54| PCB for power| 1
4| 086.50.010.26| Cable for switch(blue)| 1
5| 086.50.010.27| Cable for switch(brown)| 1
6| 086.50.010.28| Power switch| 1
7| 086.50.010.55| Bottom housing| 1
8| 086.50.010.30| Screw 4 x 25 mm| 3
9| 086.50.010.32| Cable for PCB connection| 1
10| 086.50.010.41| Sensor Temperature/Humidity| 1
11| 086.50.010.34| Sensor Oven| 1
12| 086.50.010.35| Sensor cover| 2
13| 086.50.010.36| Screw 4 x 15 mm| 4
14| 086.50.010.56| Sensor plug BIO| 1
15| 086.50.010.50| Sensor plug oven| 1
16| 086.50.010.42| Cable for sensors -4-lines (5 mtr.)| 1
17| 086.50.010.51| Plug for power| 1
18| 086.50.010.52| Plug for light| 1
ISC GmbH
**** explains the following conformity according to EU directives and norms
for the following product
Sauna Control BIO
Sauna Control BIO P &P
2014/29/EU
2005/32/EC_2009/125/EC
2014/35/EU
2006/28/EC
2014/30/EU
2014/32/EU
2014/53/EC
2014/68/EU
90/396/EC_2009/142/EC
89/686/EC_96/58/EC
2011/65/EU
2006/42/ec
Annexiv
Notified Body:
Notified Body No.:
Reg. No.:
2000/14/€c_2005/88/EC
Annex v
Annex vi
Noise: measured Lwa = dB (A); guaranteed Lwa = dB (A)
P= KW; L/Ø = cm
Notified Body:
2012/46/eu
Emission No.:
Standard references: EN 55014-1: 2006 +A1: 2009 + A2: 2011; EN 55014-2: 1997 +
A1: 2001 + A2: 2008;
EN 61000-6-1: 2007; EN 60335-1 + A11: 2014; EN 60335-2-53: 2011
Lanndau/isar,den 01.03.2019 First CE
Art.-No.: 1.-No.:
Subject to change without notice
Archive-File/Record:
Documents registrar:
Wiesenweg 22, D-94405 Landau/lsar
For EU countries only
Never place any electric tools in your household refuse.
To comply with European Directive 2002/96/EC concerning old electric and
electronic equipment and its implementation in national laws, old electric
tools have to be separated from other waste and disposed of in an environment-
friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the demand to return electrical devices:
As an alternative to returning the electrical device, the owner is obliged to
cooperate in ensuring that the device is properly recycled if owner- ship is
relinquished.
This can also be done by handing over the used device to a returns center,
which will dispose of it in accordance with national commercial and industrial
waste management legislation. This does not apply to the accessories and au-
xiliary equipment without any electrical components which are included with
the used device. The reprintig or reproduction by any other means, in whole or
in part, of documentation and papers accompanying products is permitted only
with the express consent of ISC GmbH. Subject to technical changes.
GUARANTEE CERTIFICATE
Dear Customer,
All of our products undergo strict quality checks to ensure that they reach
you in perfect condition. In the unlikely event that your device develops a
fault, please contact our service department at the address shown on this
guarantee card. Of course, if you would prefer to call us then we are also
happy to offer our assistance under the service number printed below. Please
note the following terms under which guarantee claims can be made:
-
These guarantee terms cover additional guarantee rights and do not affect your statutory warranty rights. We do not charge you for this guarantee.
-
Our guarantee only covers problems caused by material or manufacturing defects, and it is restricted to the rectification of these defects or replacement of the device. Please note that our devices have not been designed for use in commercial, trade or industrial applications.
Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e.g. connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of non- approved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e.g. sand, stones or dust), effects of force or external influences (e.g. damage caused by the device being dropped) and normal wear resulting from proper operation of the device. This applies in particular to rechargeable batteries for which we nevertheless issue a guarantee period of 12 months. The guarantee is rendered null and void if any attempt is made to tamper with the device. -
The guarantee is valid for a period of 2 years starting from the purchase date of the device. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies when an on-site service is used.
-
In order to assert your guarantee claim, please send your defective device postage free to the address shown below. Please enclose either the original or a copy of your sales receipt or another dated proof of purchase. Please keep your sales receipt in a safe place, as it is your proof of purchase. It would help us if you could describe the nature of the problem in as much detail as possible. If the defect is covered by our guarantee then your device will either be repaired immediately and returned to you, or we will send you a new device.
Of course, we are also happy offer a chargeable repair service for any defects which are not covered by the scope of this guarantee or for units which are no longer covered. To take advantage of this service, please send the device to our service address.
Installation Steuerung Plug and Play
Assambling the control/Installing the sauna control
Stand: 03/2019
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>