Structural and Functional Characteristics
- High-pressure inside the device
- I type device with grounded power connection
- Suitable for AC 220V 50Hz
Cut Out Size
Dimensions: 4 x 5 units
Product Size
Dimensions: 5 x 6 units
Technical Parameters
No. | Item | Data |
---|---|---|
1 | Voltage | AC 220V 50HZ |
2 | Power | [Missing data] |
Product Usage Instructions
Warnings
In order to ensure the proper functioning of the device, please follow the instructions below:
- If you notice any abnormal situation, immediately cut off the power, unplug the device, and contact your supplier. Do not use the device if:
- You detect a peculiar smell or fog coming from inside the unit.
- There is water or metal parts inside the unit.
- The lift unit box is broken.
- The wire inside is broken.
- Do not open the unit box randomly as it contains high pressure, which may result in fire or electric shock.
- Avoid placing any conducting liquid on top of the device to prevent electric shock or fire.
- The device is of I type, so the power should be connected to ground.
- The device is suitable for AC 220V 50Hz power supply.
Operation Instructions
Packing List
NO. | Description |
---|---|
1 | Monitor lift |
2 | Power cord |
3 | RS-485 cable |
4 | User manual |
Interface on the Bottom Case (from left to right)
- HDMI in
- VGA in (optional)
- AC 220V input power socket
- USB input (up: USB data, down: USB touch)
- RS485 in (1. RS-485+, 2. RS-485-, 5. GND)
- RS485 out (use for cluster control)
- SparePC SW power on; SA SW signal switch
- ANT Remote control (optional)
Control Introduction
RS485 Software Control:
- 9 holes interface with the computer serial port
- 232/485 intermediate bridge converter (female connector, male connector)
Top Panel Button:
-
Control Button: The Red indicator light is the power indicator.
If it is red, it means no signal. Green indicates a signal. -
Stop
-
Up
-
Down
-
Tilting
-
Tilting
Introduction to Manipulation:
- Display button
- Menu
- Auto
- Led (indicated light): NO SIGNAL (red light), WITH SIGNAL (green light)
- Display power on/off
- Variable Button(-)
- Variable Button(+)
- AUTO (Automatic adjustment button with return function)
- MENU
Frequently Asked Questions
Q: What should I do if I detect an abnormal situation?
A: If you notice any abnormal situation, immediately cut off the power, unplug the device, and contact your supplier.
Q: Can I open the unit box?
A: No, please do not open the unit box randomly as it contains high pressure, which may result in fire or electric shock.
Q: Can I put conducting liquid on top of the device?
A: No, avoid placing any conducting liquid on top of the device to prevent electric shock or fire.
Q: What is the power supply requirement for the device?
A: The device is suitable for AC 220V 50Hz power supply.
warning
In order to make sure the device is working properly, please follow below instructions:
- a. If found any abnormal situation, please cut off the power, pull off the plug and contact your supplier. To avoid any fire accident, DON’T use device in following situations:
- If you found peculiar smell or fog comes from inside of unit.
- If have water or metal parts going to the unit.
- If the lift unit box is broken.
- If the wire is broken inside.
- b. As the device is high pressure inside, please DON’T open the unit box at random to avoid fire or electric shock.
- c. DON’T put any conducting liquid on top of the device, to avoid electric shock or fire.
- d. The device is I type; the power should be connected to ground.
- e. The device is suitable for AC 220V 50Hz.
Operation instructions
packing list
NO. | description | remark |
---|---|---|
1 | Monitor lift | 1set |
2 | Power cord | 1pc |
3 | RS-485 cable | 1pc |
4 | User manual | 1pc |
--- | --- | --- |
Interface on the bottom case(from left to right)
- HDMI in
- VGA in(optional)
- AC 220V input power socket
- USB input,up: USB data, down: USB touch
- RS485 in(1:RS-485 +,2:RS-485 -,5:GND)
- RS485 out(use for cluster control)
- Spare:PC SW power on; SA SW signal switch
- ANT Remote control (optional)
Control Introduction:
RS485 Software Control: 9 holes interface with the computer serial port. 232/485 intermediate bridge converter.
connector (female) connector(male) Top panel button:
Control Button: ( The Red indicator light is power indicator, if it is red, mean no signal, green is with signal)
Introduction to Manipulation
Display button:
- LED: indicated light,
- NO SIGNAL: the light is red,
- WITH SIGNAL: Light is green.
- display power on/off
- Variable Button(-)
- Variable Button(+)
- AUTO: Automatic adjustment button and have return function.
- MENU
Characteristics and main parameters
Structural and functional characteristics
AX-17F motorized monitor lift is using the synchronous belt pulley with a straight line for rising and falling, the tilt driver will as an individual part and the max. angle is 90° (0~90° motorized adjustable). Stable structure and low noise, using the aluminum frame match with the toughened glass, more elegant. The product uses the desktop embedded design, could hide in the table perfectly.
Cut out size
product size
Technical parameters of lift
No. | Item | Data |
---|---|---|
1 | Voltage | AC 220V 50HZ |
2 | Power |
consumption
| <50W
3| Single-way
running time
| 16S
4| Tilting| 0-90° motorized adjustable
Technical parameters of display screen
NO. | Item | Data |
---|---|---|
1 | Screen size | 17.3 inch |
2 | Screen type | eDP(2Lanes) |
3 | Resolution | 1920*1080 |
4 | Aspect ratio | 16:9 |
5 | Contrast ratio | 800:1 |
6 | Brightness | 300 cd/m² |
7 | Signal type | VGA/HDMI |
(automatically)
8| View angle| 85/85/85/85
Installation instructions
- Please remove safety screws & remove the foam inside the case before charging (the screws are in the, back, right & left side of cover plate)
- Put the lift into to table cutting hole, and flushing the panel with the table.
- Connect the video signal cable (VGA or HDMI).
- Connect the USB touch line, otherwise the touch screen will not work
- For central control, please connect the RS485.
- Connect the power, when the light is bright, push the button of “up/fall back” to finish the Automatic elevation process. After that, you could push “up/down” button to adjust the angle as you want.
Central control code
All up | FF AC E1 FF 00 00 DD 01 DC |
---|---|
Stop | FF AC E1 FF 00 00 CD 01 CC |
All down | FF AC E1 FF 00 00 ED 01 EC |
Computer App control
- If required, please contact us for RS485 control software “Multifunctional-Lift Control Center V2.0 _win”。
- Prepare a converter of RS232 to RS485 or USB to RS485, and install the driver, connect all the lift which need to be control
- Download and install the software in English version, log in as admin with pass word 88888888, please adjust the langue and the correct COM after access in.
- Operate the assembly according to the app instruction
FAQ and Solutions
Common Faults
NO. | Fault | Reason |
---|---|---|
phenomenon | ||
--- | --- | --- |
1
| ****
NO display
| Check the power on or off?
Check the signal, is it interrupted?
2
| ****
Character ambiguity
| Does it match with the computer resolution? Is it the contrast and brightness
adjustment correct?
3
| ****
Black screen
| It would turn off the brightness automatically without signal, Is brightness adjustment minimum? Long press of the “Auto” key may cause shutdown and the
indicator to turn red.
4| Invalid touch
function
| Make sure the USB connection
is correct or connect well
5
| The indicator is not on| Check if the fuse is damaged.
If it is damaged, replace the fuse with 3.15A specification.
Safety Pipe Location of National Standard Socket
Common fault judgment method of the control main board
- Test the power socket between “L” and “N”(LT3 terminal of circuit board)
- The regular Resistance is about 1.1K, if there is a big difference with the value, the PCB must have some problem.
- The indicator lift is not lit, the button on panel doesn’t work, but central control is working well, maybe because of the poor contact developed due to vibration during shipment.
- The PCB board is 12V, is abnormal, please check whether the L7812 was damaged
- The PCB board is 5V, is abnormal, please check whether the L7805 was damaged
- The upper limit switch belong to pulse level control, after the pulse, it remains stop. However, the power supply of the display screen needs to keep shade through photoelectric control.
- Lower limit switch is high levels suspend control, continue to decline low. Thus when the Photoelectric control screen stop to getting down, the display screen needs to keep shade.
- Subject to change without prior notice, the current production model shall prevail.