Temas Teknoloji LS15RM Motorized Retractable Monitor lift with Microphone User Manual
- June 15, 2024
- Temas Teknoloji
Table of Contents
Temas Teknoloji LS15RM Motorized Retractable Monitor lift with Microphone
Read the instructions carefully before using the device
warning
In order to make sure the device is working properly, please follow below instructions:
a. If found any abnormal situation, please cut off the power, pull off the plug and contact your supplier. To avoid any fire accident, DON’T use device in following situations:
- If you found peculiar smell or fog comes from inside of unit.
- If have water or metal parts going to the unit.
- If the lift unit box is broken.
- If the wire is broken inside.
b. As the device is high pressure inside, please DON’T open the unit box
at random to avoid fire or electric shock,.
c. DON’T put any conducting liquid on top of the device, to avoid
electric shock or fire.
d. The device is I type; the power should be connected to ground.
e. The device is suitable for AC 220V 50Hz.
f. DO NOT place the machine in the direct sunlight area, avoid causing
high temperature, circuit board short circuit, fire or electric shock.
g. When the product is lifted, no heavy objects shall be placed on the
top panel, which may easily cause excessive lifting load and affect the
service life of the equipment.
h. To avoid damage to the equipment, please install the fastening screws
of the device and pull off power plug and other cables before moving it, and
remove the fastening screws before connecting the power again.
Operation instructions
packing list
NO. | description | Remark |
---|---|---|
1 | Monitor lift | 1set |
2 | Power plug | 1pcs |
3 | RS-485 cable | 1pcs |
4 | User manual | 1set |
Interface on the top panel(from left to right, for Bosch)
- control the movement of monitor
- microphone switch control
No. | Symbol | function |
---|---|---|
1 | Speech button | |
2 | Prior button for president position |
Interface on the bottom case(from left to right)
- AC 220V input
- ANT Remote control ( optional )
- Spare: PC SW power on; SA SW signal switch
- RS485 in(1 :RS-485 +,2:RS-485 -,5:GND)
- RS485 out(use for cluster control )
- USB input,up: USB data, down: USB touch
- VGA in(optional)
- HDMI in
Introduction to Manipulation
Display button :
-
LED: indicated light, NO SIGNAL: the light is red,
WITH SIGNAL: Light is green。 -
: display power on/off
-
: Variable Button(-)
-
: Variable Button(+)
-
AUTO: Automatic adjustment button and have return function.
-
MENU
Characteristics and main parameters
Structural and functional characteristics
AX-15MG motorized monitor lift is using the synchronous belt pulley with a straight line for rising and falling, the tilt driver will as a individual part and fixed 16°. Stable structure and low noise, using the aluminum frame match with the toughened glass, more elegant. The product uses the desktop embedded design, could hide in the table perfectly, two motors control the movement of screen and microphone, also auto-calibration movement of microphone protect the gooseneck from damage by performance error.
Cut out size (for Bosch)
product size (for Bosch)
Technical parameters of lifts
NO. | Item | data |
---|---|---|
1 | Voltage | AC 220V 50HZ |
2 | Power consumption | <45W |
3 | Single running time | 13S |
4 | Tilting | 15° fixed |
5 | Working |
temptation
| 0—50℃
Technical parameters of display screen
NO. | Item | Data |
---|---|---|
1 | Screen size | 15.6 |
2 | Resolution | 1920*1080 |
3 | Aspect ratio | 16:9 |
4 | Contrast ratio | 800:1 |
5 | Brightness | 250 |
6 | View angle | 85/85/85/85 |
Installation instructions
-
Please remove 4 pcs safety screws & remove the foam inside the case before charging (the screws are in the, back, right & left side of cover plate)
-
Put the lift into to table cutting hole, and flushing the panel with the table.
-
Connect the video signal cable (VGA or HDMI).
-
Connect the USB touch line, otherwise the touch screen will not work
-
For central control, please connect the RS485.
-
Connect the power, when the light is bright, push the button of “up/fall back” to finish the Automatic elevation process. After that, you could push “up/down” button to adjust the angle as you want.
Central control code
All up | FF AC E1 FF 00 00 DD 01 DC |
---|---|
Stop | FF AC E1 FF 00 00 CD 01 CC |
All down | FF AC E1 FF 00 00 ED 01 EC |
Computer App control
- If required, please contact us for RS485 control software “Multifunctional-Lift Control Center V2.0 _win”。
- Prepare a converter of RS232 to RS485 or USB to RS485, and install the driver, connect all the lift which need to be control
- Download and install the software in English version, log in as admin with pass word 88888888, please adjust the langue and the correct COM after access in.
- Operate the assembly according to the app instruction
FAQ and Solutions
No. | Fault phenomenon | Reason |
---|---|---|
1 | NO display | Check the power on or off? Check the signal, is it interrupted? |
2 | Character ambiguity | Does it match with the computer resolution? Is it the |
contrast and brightness adjustment correct?
3| Black screen| It would turn off the brightness automatically without
signal, Is brightness adjustment minimum? Long press of the “Auto” key may
cause shutdown and the indicator to turn red.
4| Invalid touch function| Make sure the USB connection is correct or connect
well
5| The indicator is not on| Check if the fuse is damaged. If it is damaged,
replace the fuse with 3.15A specification.
- Subject to change without prior notice, the current production model shall prevail.