LiFE Twenty5 25L Dehumidifier User Manual

June 16, 2024
LIFE

Twenty5 25L Dehumidifier, air purifier and air ioniser

LiFE Twenty5 25L Dehumidifier

User Manual

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS.

Read the operating instructions carefully before putting the appliance into operation and keep the instructions, the receipt and, if possible, the box with the internal packing. If you give this device to other people, please also pass on the operating instructions.

USER MANUAL SYMBOLS
Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:
WARNING: This sign warns you of dangers to your health and indicates possible injury risks.
CAUTION: This sign refers to possible hazards to the machine or other objects.
NOTE: This sign highlights tips and information.
This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.
  Service personnel are required to carefully read the USER MANUAL and SERVICE MANUAL before operation.

SAFETY INSTRUCTIONS

  1. CAUTION: The appliance is designed for use with R290 (propane) as the default refrigerant.

  2. CAUTION: The appliance must be used and stored in places where there is no source of heat emission.

  3. R290 has no harmful effect on Ozone Depletion Potential (ODP), negligible effect on Global Warming Potential (GWP) and is available worldwide. Due to its energy efficient properties, R290 is suitable as a refrigerant for this application.
    Special precautions must be taken due to the high flammability of the coolant.

  4. The refrigerant loop is sealed. Only a qualified technician should attempt service!

  5. The refrigerant R290 (propane) of this product is odorless, flammable and heavier than air.

  6. R290 refrigerant is first collected in low areas but can be circulated by the fans.

  7. Do not attempt to speed up the defrosting process or clean the frozen part.

  8. Refrigerant (propane) must not be discharged nto the atmosphere.

  9. If there is a propane gas leak or even if it is suspected, do not let untrained personnel try to find the cause of the leak.

  10. The refrigerant R290 (propane) of this product is odorless. A lack of smell does not ndicate a lack of escaping gas. If a propane leak is found or suspected, evacuate the area immediately, ventilate the room, and contact your local fire department to notify them of a propane leak.

  11. Do not let anyone back into the area until you are sure the problem has been resolved and it is safe to return to the area.

  12. This appliance is intended for use by specialist or trained users in shops, light industry and farms or for commercial use by ordinary people.

  13. This appliance can be used by children aged 16 years and over and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the associated risks.

  14. Keep the appliance and its cord away from children and pets.

  15.  Children must be supervised so that they do not play with the appliance. Children should not play with the appliance.

  16. Cleaning and maintenance by the user must not be carried out by children without supervision.

  17. To ensure the safety of children, keep all packaging materials (plastic bags, boxes, etc.) away from them.
    WARNING: Do not allow children to play with the packaging materials. Risk of suffocation!

  18. Prohibited for use by children.

  19. Do not use the appliance outdoors.

  20. Do not use the appliance in spaces smaller than 4 sq.m. and in unventilated areas.

  21.  The appliance must not be used in the bathroom, in laundry rooms, in a swimming pool, in the rain or in areas with high humidity.

  22.  Do not place the appliance near heat sources ( eg fire, electric heaters, radiators, fireplaces, etc.) .

  23. Do not use the dehumidifier in areas where there are flammable materials such as gasoline, paints, solvents or similar materials.

  24. Do not place or hang the following, similar, or other flammable materials such as paper, plastic, etc., on, n front of, or inside the appliance.

  25. No flames, cigarettes or other possible sources of ignition should be used in or near the appliance.

  26. Accessories are designed for propane and are non-sparking. Parts should only be replaced with identical parts.

  27. **CAUTION:** Do not cover the appliance with any object. Fire hazard!

  28. CAUTION: Do not cover the air inlet/outlet grills or restrict the flow of air through them.

  29. CAUTION: Do not put your fingers inside the nput/output grills or objects on or inside the appliance. Avoid contact with moving parts of the appliance. Risk of electric shock!

  30. Do not climb or sit on the appliance.

  31. This product must be located in a space with a surface area greater than 4 sq.m. when used, repaired and stored.

  32. Make sure your mains voltage is the same as the voltage on the appliance’s rating label.

  33. The installation must be done according to the regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical network, make the necessary modifications with the help of a qualified electrician.

  34. Use the appliance only in a grounded and properly installed outlet.

  35. Do not use an extension cord or power strip to connect the appliance.

  36. The appliance is not intended for operation with an external timer or with a separate remote control system.

  37. For maximum performance keep a sufficient distance (at least 30cm) from the wall or objects.

  38. Place the appliance on a stable and flat surface.

  39. Make sure the power cord does not come into contact with hot surfaces or sharp corners and objects.

  40. Do not lay the cable under carpets.

  41. Keep a distance of at least lm. around all sides of the appliance to allow adequate air circulation during use.

  42. Do not leave the appliance unattended. If you leave the room, always disconnect the appliance from the power supply.

  43. Do not tilt the unit. The appliance is designed to operate only in an upright position.

  44. The dehumidifier must always be stored and transported in an upright position, otherwise irreparable damage to the compressor may occur.

  45. Do not disconnect the appliance directly from the power supply during operation.

  46. Always unplug the appliance from the power supply when you are finished using it.

  47. Always disconnect the appliance from the power supply when you want to move it to another place.

  48. Always disconnect the appliance from the power supply before cleaning, servicing or storing.

  49. Always switch off and disconnect the appliance from the power supply when adding / removing parts (remove by holding the plug, not pulling the cable).

  50. Do not disconnect the appliance from the power supply by pulling on the cable.

  51. The appliance must be regularly checked for damage. Do not use the appliance if it is damaged.

  52. Do not use the appliance if the cord is frayed or if the appliance has been dropped or otherwise damaged. To avoid the risk of electric shock, do not attempt to repair the appliance yourself. Contact a qualified technician for repair. Use only original spare parts.

  53. Any service other than cleaning or replacing the filter should be performed by an authorized dealer. Contact a qualified technician for repair. Use only original spare parts.

  54. If the surface is cracked, disconnect the appliance from the power supply to avoid the possibility of electric shock.

  55. This appliance is not designed to be immersed in water during cleaning. Follow the instructions in the CLEANING section.

  56. It s prohibited to use chemical cleaners when cleaning the appliance.

  57. Do not immerse the appliance in water or any iquid and do not expose the appliance to rain.

  58. To avoid the risk of electric shock, do not immerse the cord, plug or appliance in water or any other liquid.

  59. Do not touch the appliance with wet or wet hands. Keep the appliance away from liquids and splashes.

  60. The appliance must be used and stored in places where there is no source of continuous heat emission (such as an open flame, a working gas heater or an electric heater, stove, radiators in operation, etc.).

  61. The appliance must be stored in such a way as to avoid mechanical damage .

  62. The appliance must be stored in a well-ventilated area where the size of the room corresponds to the area of the room as determined for operation.

  63. The appliance must be stored in well-ventilated areas.

  64. Do not cut or burn the appliance, even after use.

  65. Compliance with national gas regulations must be observed.

LiFE Twenty5 25L Dehumidifier - Symbol 7

FAILURE TO FOLLOW THIS WARNING COULD RESULT IN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE

WARNING: Any person who performs work or intervenes in refrigeration circuits should hold a valid certificate from an industry-accredited assessment authority, which will approve the specific person’s adequacy for the safe handling of refrigerants. The certificate must be issued in compliance with some industry-recognized evaluation specifications.
WARNING: The service should only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

SAFETY PRECAUTIONS BEFORE SERVICING THE APPLIANCE

Follow the warnings below before servicing the dehumidifier.

CONTROL OF THE AREA
Before starting any work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. To repair the cooling system, the following precautions must be observed before working on the appliance.

DEFINITION OF WORK PROCEDURE
Work is carried out in a controlled manner to minimize risk presence of flammable gas or vapor during the execution of the work.
WORKPLACE
All qualified staff and others working in the local area are informed of the nature of the work being carried out. Working in confined spaces should be avoided. The area around the workplace must be separated. Ensure that conditions within the area have been made safe by checking for flammable material.

CHECK FOR THE PRESENCE OF REFRIGERANT
The area is checked with a suitable refrigerant detector before and during the work to ensure that the qualified technician is aware that there is an ignition hazard. Ensure that the leak detection equipment used is suitable for use with flammable refrigerants, i.e., non-sparking, adequately sealed or intrinsically safe.

FIRE EXTINGUISHER PRESENT
If work is to be carried out on the refrigeration equipment or other related parts, suitable firefighting equipment must be available. Have a dry powder or C02 extinguisher.

IGNITION SOURCES
No person carrying out work in connection with a refrigeration system which involves the exposure of any piping containing or containing a flammable refrigerant shall use sources of ignition in such a manner as to result in a fire or explosion hazard. All possible sources of ignition, including cigarette smoking, must be kept well away from the site of installation, repair, removal and disposal, during which flammable refrigerant may be released into the surrounding area. Before working, the area around the equipment should be checked to make sure there are no flammable or ignition hazards. There must be a “No smoking” sign in the area.

WELL VENTILATED AREA
Make sure the area is open or adequately ventilated before operating the appliance or performing any work. The area must be adequately ventilated during the work period. The vent should safely disperse any released refrigerant and preferably exhaust it  externally to the atmosphere.

CHECKING EQUIPMENT CONTAINING REFRIGERANT
If electrical components are changed, they must be fit for purpose and meet the manufacturer’s specifications. Also, the manufacturer’s maintenance and care instructions must always be followed. If in doubt consult the manufacturer’s technical department for assistance.

The following controls apply to installations using flammable refrigerants:

  • The appliance must be stored in a well-ventilated area where the size of the room corresponds to the area of the room as determined for operation
  • Ventilation machines and outlets are functioning adequately and are not obstructed.
  • If an indirect refrigerant circuit is used, the secondary circuit is checked for the presence of refrigerant.
  • Marking on the equipment must be visible and legible. Signs that are illegible must be corrected.
  • The cooling pipe or components are installed in a location where they are unlikely to be exposed to any substance that can corrode components containing the refrigerant, unless the components are made of materials that are inherently corrosion resistant or are properly protected from to corrode.

CHECK OF ELECTRICAL APPLIANCES
Repair and maintenance of electrical components includes initial safety checks and component inspection procedures. If there is a fault which could compromise safety then no electrical supply shall be connected to the circuit until it has been satisfactorily dealt with. If the error cannot be corrected immediately, but it is necessary to continue operation, an appropriate temporary solution must be used. This should be reported to the owner of the equipment so that all parties are informed.

Initial security checks include:

  • Discharging capacitors: this must be done in a safe manner to avoid the possibility of ignition.
  • that there are no electrical components and wiring exposed when charging, recovering or cleaning the system.
  • that there is earth continuity

PARTS IDENTIFICATION

FRONT PART

  1. Control panel

  2. Air outlet

  3. Digital LED display

  4. Housing

  5. Swivel castors

  6. HandleLiFE Twenty5 25L Dehumidifier - Parts REAR PART

  7. Air filter

  8. Continuous drainage

  9. Water tank

CONTROL PANEL

LiFE Twenty5 25L Dehumidifier - Panel

  1. ION function on / off button
  2. Lock button (child-lock)
  3. Timer switch on / off button
  4. Adjustment button of room humidity / time adjustment / temperature unit selection
  5. LCD screen / LED indicator lights
  6. Adjustment button of room humidity / time adjustment / temperature unit selection
  7. Air speed selector key with LED indicator light
  8. Mode selection button
  9. Power on / off button

INDICATOR LIGHTS

| Automatic operation
---|---
| Low speed
| ION function
| Continuous dry function
| High speed
| Child lock
| Sleep mode
| Full water tank
| Power on / off
| Humidity level indicator / Timer

POSITIONING THE DEHUMIDIFIER

LiFE Twenty5 25L Dehumidifier - Positioning

  1. Remove all packaging materials and keep out of reach of children.

  2. After unpacking the dehumidifier check for possible damage. In case of damage or visible problem, do not use the appliance and contact the store where you bought t.

  3. Check that the voltage of the mains you will use matches the operating voltage of the appliance and that they are n correspondence.

  4. Place the dehumidifier on a flat surface and away from flammable objects. Always keep away from children.

  5. Place the dehumidifier on a stable and flat surface.
    CAUTION: Never place the dehumidifier:
    • near heat sources (e.g. heaters, radiators, fireplaces, etc.)
    • in a place exposed to sunlight or rain
    • where water or oil may fall on it
    • in rooms with a ot of dust
    • in poorly ventilated rooms
    • in areas with an uneven surface
    • in areas where ground vibrations are generated
    • in spaces smaller than 4 sq.m.
    • in areas where there are flammable materials
    • outdoors
    • near walls, curtains or objects that prevent proper air circulation

  6. WARNING: Place the dehumidifier in well-ventilated areas larger than 4 sq.m .

  7. Leave at least 30cm of space around the appliance for better air circulation and more efficient operation of the dehumidifier.

  8. Keep the air inlet and outlet clear of obstructions.

  9. Place blinds facing up before first use.

  10. Make sure that the water container s empty and correctly placed in its place, otherwise the appliance will not work properly.

NOTES:

  • If the dehumidifier is raised above 45°, eave the dehumidifier in a vertical position for 24 hours before operating it.
  • Do not attempt to move the wheels on carpet or uneven surfaces, or move the unit when there is water in the container, as it may tip over and spill water.
  • The dehumidifier works deally in rooms with temperatures from 5°C to 35°C.

USING THE APPLIANCE

  1. Check that the voltage of the mains you will use matches the operating voltage of the appliance and that they are n correspondence.
  2. Make sure the appliance s unplugged and turned off.
  3. Plug the dehumidifier nto a properly installed and grounded outlet.
  4. In standby mode, press the dehumidifier on/off button. The power LED lights up, the default fan speed s set to the highest evel, and the default humidity is set to 50%. To turn off the appliance, press the dehumidifier on/off button. The power LED turns off, the compressor stops running, while the fan continues to run for 30 seconds and then stops.

APPLIANCE FUNCTIONS
The dehumidifier has the following functions. Select the desired function by pressing the function selection key on the control panel.
AUTOMATIC OPERATION
When the ambient humidity evel is ≥ +3% of your selected humidity level setting, the fan and compressor start to operate. When the ambient humidity level is ≤ -3% of your selected humidity evel setting, the compressor and fan will stop operating after 30 seconds.
The air speed evel and humidity level can be adjusted in automatic mode.
NOTE: When the unit is defrosting in this mode, the indicator light is on.
CONTINUOUS DRY FUNCTION
The dehumidifier operates continuously, but the humidity evel cannot be adjusted.

  SLEEP MODE
After 10 seconds without operation of the appliance, all indicator lights switch off gradually so as not to bother you during sleep and the air speed evel changes automatically from high to low.
Press any key to activate the indicator ights on the control panel. Press the Sleep mode selection button again to exit the Sleep mode.
In sleep mode, when the ambient humidity is ≥+3% the humidity you have selected, the fan starts running and the compressor starts running after 3 minutes.
When the ambient humidity is ≤-3% the humidity you have selected, the compressor stop operating immediately and the fan stop operating after 30 seconds.
No fault code is displayed, the low speed cannot be not adjusted, and the humidity is adjustable.

AIR SPEED LEVEL ADJUSTMENT

  1. Press the air speed selector key once to adjust the fan speed to the lowest level. Once you select the desired speed level, the corresponding LED light on the control panel will light up.
  2. Press the air speed selector key again to adjust the fan speed to the highest level. Once you select the desired speed level, the corresponding LED light on the control panel will light up.
    NOTE: The fan speed cannot be adjusted during continuous drying mode, sleep mode and during defrosting.

HUMIDITY LEVEL ADJUSTMENT

  1. Press the adjustment button of room humidity once and the current ambient humidity percentage will appear. Press again to adjust the desired humidity level. The humidity level can be set from 30% to 80% with a 5% increase step.

  2. When you select the desired level, the dehumidifier confirms the desired setting after 3 seconds.
    Then dehumidifier exits the setting mode and the current percentage of ambient humidity is displayed on the screen.

  3. Press and hold the adjustment button of room humidity for 3 seconds to display the current ambient temperature. After 5 seconds, the current ambient humidity will return to the screen .

TIMER
Press the timer switch on / off button to set the timer. Press the timer switch on / off button to set the timer. Each time you press the button , the value increases by 1 hour and the corresponding number is displayed on the screen. Each time you press the button  the value decreases by 1 hour and the corresponding number is displayed on the screen. The corresponding LED indicator light lights up when the programming is completed. The device will be turned on / off as soon as the specified time arrives and the LED indicator light will switch on/off. You can adjust the timer with one of the following two options available to your preference:

  • Activation of the appliance with a time delay (the device is in standby mode): In standby mode the set number represents the time period in hours after which the dehumidifier will starts its operation.
  • Deactivating the device with a time delay (adjustment during operation): During the operation of the dehumidifier, the set number represents the number of hours of dehumidifier operation before turning off.

To turn off / off the timer setting, set the timer to “OO”. ION FUNCTION

Press the ion function on / off key to activate the ion function. Press again to turn off.

ION FUNCTION
Press the ionization function on / off key to activate the ionization function. Press again to turn off.
CHILD LOCK
Press and hold the lock (child lock) button for 3 seconds to enable/disable the child lock function.
As soon as the function is activated, the corresponding LED indicator on the control panel lights up.
MEMORY FUNCTION IN THE EVENT OF A POWER FAILURE
In the event of a power failure, and when the power is restored, the dehumidifier will resume after 3 minutes the state prior to the power failure.
If the dehumidifier was turned on before the power failure, it will start working after the power is restored.
If the dehumidifier was on standby mode before the power failure, it will remain in standby mode after the power is restored.

DEFROST FUNCTION
When the ambient temperature is too low, the dehumidifier will enter defrost mode in order to protect the compressor and the LED indicator light will illuminate on the control panel.
DRAINAGE
When the water tank is full, the appliance will automatically stop working. At the same time, a notification sound will be heard and the full water tank indicator light on the control panel will light up.

There are two available options in order to remove the water collected from the dehumidifier:

  • Manual draining: Empty the collected water from water tank.
  • Continuous draining: Use the drain hose for continuous water drainage

MANUAL DRAINING

  1. Press the power on / off button to turn off the dehumidifier.
  2. Hold the water tank and pull it out of the dehumidifier body carefully.
  3. Empty the water tank.
  4. Clean the inside of the water tank from any debris as well as the outer casing.
  5. Insert the empty tank back into the appliance.
  6. Press the on / off button to continue.
  7. If the full tank indicator light does not go out, make sure the water filling sensor is in place.

CONTINUOUS DRAINING
Dehumidifier has a drainage port that allows continuous drainage of collected water.

  1. Press the power on / off button to turn off the dehumidifier. Pull the power cord away from the drainage port.
  2. Attach the drain hose (included in the package) to the drainage port located on the back part of the appliance for continuous drainage, as shown in the figure below.
  3. Make sure that the drain hose is straight, does not fold, is not obstructed by objects and is directed downwards allowing water to flow by gravity to an external drain. Ensure that the end of the drain hose is lower than the drain opening, otherwise the collected water will not drain and flooding or other or other problem may occur.

Notes:

  • Do not submerge the end of the drain hose into the water as it may cause “Air Lock” in the hose.
    Risk of water leakage, appliance malfunction and electric shock!

  • As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20°C.

CLEANING
Follow the instructions to safely take care of the dehumidifier.

  1. Always make sure that the appliance is unplugged before cleaning it.
  2. Do not pour water on or inside the appliance.
  3. Clean the appliance housing and control panel with a soft damp cloth.
  4. Do not use anything abrasive that can scratch or damage the appliance. Do not use a wire brush or other abrasive utensils for cleaning. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.

CLEANING OF THE EXTERNAL HOUSING AND OF AIR OUTLETS

  1. Use a vacuum cleaner or a soft brush to clean the air outlets.
  2. Wipe the body of the appliance with a soft damp cloth and wipe well to dry.
    CAUTION: Do not allow water to drip on or inside the appliance. Danger of electric shock! Risk of appliance malfunction!

CLEANING OF THE WATER TANK
Be sure to clean the tank regularly to prevent mold and bacteria growth.

  1. Press the on/off button to turn off the dehumidifier.
  2. Grasp and slide the water tank out of the dehumidifier body carefully.
  3. Clean the tank with water and a mild and mild detergent. Do not use scourers or wire, chemically treated dust-resistant cloth, benzine, benzene, thinner or other chemical cleaners as they may corrode the tank and cause leakage.
  4. Dry thoroughly before putting it back on the unit.
    NOTE: Do not use a dishwasher to clean the water tank.

CLEANING OF THE FILTERS
Dust is collected in the filter and blocks the air flow. Limited airflow reduces system efficiency and damage may occur to the unit.
The air filter requires regular cleaning (at least every 2 weeks). The air filter is removable for easy cleaning.

CAUTION: Do not operate the appliance without an air filter.

  1. Remove the filter frame on the back of the dehumidifier and carefully remove the air filter.
    LiFE Twenty5 25L Dehumidifier - Fig 2

  2. Use a vacuum cleaner to gently absorb dust from the surface of the filter. If the filter is very dirty, wash it with water and a soft, mild detergent. Dry carefully before placing it back in the unit.

  3. When the cleaning of the air filter is completed, dry the air filter well, place it back in unit and reassemble the appliance.

LiFE Twenty5 25L Dehumidifier - Fig 4

HEPA & HEPA & CARBON FILTER
Dehumidifier includes detachable 2 stages air filters HEPA+ Active Carbon (besides the standard filter), for effective air purifying.
The acronym HEPA comes from the words High Efficiency Particulate Air. It is a filtration system that removes 99.97% of tiny particles whose diameter is equal to 0.3ym. It also removes germs, reducing the chance of allergies.
Activated carbon filter odors and volatiles from the air, including cigarette smoke, food odors and ozone.
HOW TO INSTALL THE FILTERS:

LiFE Twenty5 25L Dehumidifier - Fig 5 To install the HEPA and activated carbon filters, remove the pre-installed filter from the dehumidifier, place the HEPA and activated carbon filters in position and place the pre-installed filter on top of them.
HEPA AND CARBON FILTER CLEANING
Remove the pre-installed filter from the dehumidifier, remove the HEPA and activated carbon filters and clean very gently with a soft cloth.

NOTES:

  • Do not wet HEPA and activated carbon filters.
  • These filters work effectively for 10 to 12 months depending on the use. After this time, it is recommended that you discard them and buy new ones or operate the device only as a dehumidifier (not as an air purifier) using the pre-installed filter.

STORAGE

If you do not use the appliance for a long time, clean the appliance, allow t to dry well and store it.

  1. Always unplug the appliance before storing it.
  2. Drain any water n the water tank.
  3. Clean the filter and allow it to dry completely.
  4. Place the filter back into place.
  5. Wrap and place the power cord inside the water tank.
  6. The unit must be kept n an upright position during storage.
  7. Always make sure that the appliance is cold, dry and clean before storing.
  8. Always store the appliance out of the reach of children.
  9. Always store the appliance in a well-ventilated, humid, safe and clean place. For the better protection of the appliance, store it in ts original packaging.

CAUTION: The evaporator inside the machine has to be dried out before storing in order to avoid unit damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to set the humidity level 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours

DISPOSAL OF APPLIANCE
**** This symbol appearing on the product, ts accessories or accompanying manuals indicates that the product and its electronic accessories should not be disposed of with other household trash.
In order to avoid possible harmful effects on the environment or health due to uncontrolled waste disposal, please separate these products from other types of waste and recycle them.
Household users should contact either the store where they purchased this product or their local services for details of where and how they can return these products for environmentally safe recycling.

WARNING: The release of refrigerant into the atmosphere is strictly prohibited!

TROUBLESHOOTING

OPERATING TEMPERATURE
5°C ≤ room temperature ≤ 35°C
When the ambient temperature is lower or higher than the operating temperature, the dehumidifier stops operating.
When the ambient temperature is greater than or equal to 5°C and less than or equal to 16°C, the compressor automatically defrosts at intervals. During defrosting, the compressor stops working and the fan continues to operate.

Problem Possible Cause Solution
Not working No power supply Connect to a functioning outlet and switch on
Water Full Indication Flashes Drain water tank and reset it, or re-position

the water tank to right place
Room temperature < 5°C, or > 35 °C| Self-Protection designed to protect the unit. Cannot work under such temperature
Bad functioning| Is the air filter clogged?| Clean the air filter as instructed
Is the intake duct
or discharge duct obstructed?| Remove the obstruction from the discharge duct or intake duct
No air intake| Is the filter clogged?| Wash the filter
Loud noise
when running| Is the machine put in the plat place?| Put the machine on the plat ground
Is the filter clogged?| Wash the filter
E2| Humidity sensor problem| Change a sensor
FL| Water tank is full| Empty the water tank
LO| Environmental humidity is below 20%| The dehumidifier shuts down for self- protection
HI| Environmental humidity is above 90%
CL| Low temperature protection, the environmental temperature <5t
CH| High temperature protection, the environmental temperature >351C
The dehumidifier does not produce water| Adjusted humidity level lower than that present in the room| Set the dehumidifier’s humidity level to a level lower than the current humidity level reading
The temperature is too low for efficient water extraction| Increase the temperature in the room or change the position of the appliance
Blocked output of the unit| Remove any obstructions and reboot the appliance

Ionias Kalochori, 570 09 Thessaloniki, Greece, TEL. +30 2310 700. 777
e-mail: info@sun.grwww.life.gr

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals