PROIDUCT

Product Description

  1. Type-C charging interface/Video streaming data transmission interface connected to the computer Power switch/photo button
  2. Lamp brightness adjustment wheel
  3. Focal length adjustment wheel
  4. Lighting lampshade
  5. Dust cover
  6. Image reduction key/data stream switch key
  7. Image magnification key/wireless signal conversion key

Key Description

  1. MagiLens-0TXT10-High-Definition-Electronic-Digital-Microscope-02 Connect the charger for charging when the equipment is low, and the bright red indicator light during the charging Full of charging indicators into blue lights.
  2. It can adapt to various mobile phone chargers on the market.

It can be fully charged in about 1.5 hours

MagiLens-0TXT10-High-Definition-Electronic-Digital-
Microscope-04

  1. During the use process, you can adjust the brightness of the lighting according to personal needs, The light can only be turned on when the device is turned on.

MagiLens-0TXT10-High-Definition-Electronic-Digital-
Microscope-05

  1. power button: Press 2 seconds to turn on the shutdown state and click to take pictures during the use. Press the shutdown in the start state for 3 seconds to shut down.
  2. Indicator light: This product supports AP, STA, and PC models. It has made three colors of lighting instructions for a better experience.

MagiLens-0TXT10-High-Definition-Electronic-Digital-
Microscope-06

  1. Shrink Button: Short pressing the image to reduce the image. Press and hold it for 5 seconds to turn on the PC CAM mode and enter the computer preview mode. Press 5 seconds to switch to the mobile phone preview mode.
  2. El Magnifying Button:Click the button to enlarge the picture in the working state, and press for 5 seconds to switch the AP/STA mode for 5 seconds. AP mode blue light, STA mode green light.

MagiLens-0TXT10-High-Definition-Electronic-Digital-
Microscope-07

  1. Focus Adjusting Rollers:In the working state, the rotating roller regulates the focal length to adjust the details of the focus observation of the items

Product Parameters

Indicator Light And Connecting Device

Indicator Light

  1. Red Light Flashing  Low Power Red Light Light (Under Charging) Charging
  2. Blue Light Flashing – Waiting For Wifi Connection Blue Light Is Always On Connected To The Phone Blue Light(Under Charging)  Full Power
  3. The Green Light Is Always On-USB Mode Green Light Flashing – Waiting For Connection Green Light Breathing  Connection Succeeded
  4. The Indicator Light Is Turned Off In The Shutdown State

AP mode connection device

  1. Long press the power button for two seconds of green lights and flash, turn on the lighting light adjustment wheel (During the use process, the lighting of the lighting can be adjusted according to individual needs. The light can only be turned on in the state of the device.)

  2. Long press for five seconds # Button to switch to the blue light AP

  3.  Open the application “XRCAM”

  4. Click on the upper right corner  add device

  5. Choose the corresponding device

  6. Click the connected product WiFi to connect to the Bluetooth device After the connection is successful, return the application “XRCAM” and click the “Start” button.

STA Mode Connection

Device (Automatic power-on connection)

  1. After successfully connecting the device, open the application “XRCAM”

  2. Click on the upper right corner “+” add device

  3. Click the live button

  4. Click to connect to the phone hotspot

  5. Enter the wifi name and password and confirm

Note :

  • The hot spot must not have space and dividend numbers
  • The device is a 2.4G band device. The STA mode cannot be connected to the 5G signal.
  • The indicator light flickered in the green light, indicating that it is opening the STA mode to search for the specified hotspot connection. After normal connection, the green light becomes the breathing light. At this time, as long as the connected hotspot is the mobile phone, or the mobile phone connects the same hot spot with the device to use the equipment normally.
  • The device will save hot spots and passwords in the  STA mode. The next time the boot device will default to open the STA mode by default, as long as it is automatically connected within the corresponding hotspot signal range. (5 seconds without connecting the device, automatically turn to AP mode. Long press the zoom button 5 seconds to STA mode).
  • In STA mode, long press the magnification key for 5 seconds to enter AP mode. and the blue light flashes.

Pc Mode Connection Device

  1. The device is connected to the computer with a USB through USB under normal boot state.
  2. Long press and reduce the keys for 5 seconds, indicate the green light and light, and enter the PC mode.
  3. Open the computer -side application “AMCAP” to observe HD image on the high-definition large screen.

Outdoor Remote Live Broadcast

  1. Enable device STA mode/AP mode connection device (For details, please refer to the “STA mode “Formulating Equipment” “AP mode connection device”).
  2.  Open the Douyin APP, open the screen recording live broadcast, you can live in real time.

Use This Product On los & Android Device
App Download iOS device:
Search XRCAM in the App Store, and click Installation afte successful acquisition. Android international version: search and install XRCAM in Google Play.
Android Chinese Version: Use a mobile browser to scan the QR code to download and install

You can also scan the QR code through your mobile phone Download and install.

In order to ensure that the APP can run normally, you need to open the permission to access the camera and allow the access to access the mobile phone memory.

Open The Device
Press and hold the device power button for 3 seconds, the indicator light is on, and the current state is normal.

Focus And Brightness
Adjustment In the state of taking pictures and video recording, aiming at the target of observation and slightly adjust the focal length of the roller. At the same time, the lighting brightness of the LED light of the lens is adjusted according to the lighting environment of the light environment to achieve the clearest magnification.

Photograph

  1. Short pressing the microscope power button
  2. Click on the screen to take a photo icon

Videos

  1.  Click on the screen to record icons If to start recording, and click again to stop recording

Note : APP can conduct real -time observation, camera, video recording, viewing files, comparison, rotation, zooming, reduction, setting and other operations.

Use This Product On Windows Computer

  1. Enter the URL on the browser http://www.xdssemi.com/icshow-184-252-1.html Download and install AMCAP software.

  2. Press Reduction button of green lights for 5 seconds to enter the USB Camera mode.

  3.  Connect to the computer via USB cable and open the installed Amcan software.
    MagiLens-0TXT10-High-Definition-Electronic-Digital-
Microscope-019

  4.  Click on the menu bar Options-Preview to open the real-time preview |

Note : If the data cable is loose, it will cause the screen to transmit an error black screen. New data cables need to be replaced in time.

Use This Product On Your Mac Computer

  1. Locate Photo Booth in the applications directory of the Access window;
  2. Connect to the computer with the USB data cable, long press the microscope switch for 3 seconds, and turn on the PC mode;
  3.  Click Photo Booth to run and select Camera-USB CAMERA.

Charging And Indicator Working Status

Charging

  1. Please use the DC-5V charging adapter to charge the device in time. Using the device during charging may affect the battery life;
  2. The device has built-in polymer lithium battery, which can be used continuously for more than 2 hours after full, and the charging time is about 1 hour;
  3. Mobile power can be used to charge the device. Note: The charging voltage is DC5V, it is recommended to use the original mobile phone charger as the product Charging, greater than DC5V charger, may cause circuit failure, damage the product.

Charging light

  1. The charging red light is on, and the full red light is off;
  2. After the device is turned on, the blue light starts to blink, and the blue light is steady on after the WiFi is connected;
  3. When the device battery is insufficient, the Red light flashes quickly.

Statement

  1.  The WiFi signal on the device is a hotspot transmission, not an Internet signal source LAN;
  2. Android phones cannot use the mobile network after connecting to the product WiFi hotspot, while iPhone and Apple phones still support the use of mobile network. This is related to the mobile phone system and the product is currently unable to solve this problem. However, you can use the STA mode of the device to connect with the mobile phone without occupying the Internet channel of the mobile phone.

Matters Needing Attention

  1. The equipment belongs to precision imaging products, do not knock, impact, squeeze and fall this product;
  2. Built-in polymer lithium battery, please comply with the local battery recycling terms;
  3. Do not soak in water or store in a humid place for a long time;
  4. Shall not be exposed to the equipment in the hot sun for a long time;
  5. Do not use in the  environment with large water vapor, easy to cause blurred lens or motherboard damage;
  6. Do not use sharp instruments to scratch the lens surface, which will cause irreparable failure;
  7. Each time the product is used up, please timely storage and storage, do not throw randomly;
  8. Do not use corrosive detergent to wipe the equipment, which will cause damage;
  9. The equipment is not used for a long time, it is recommended to charge at least once everv month:

Fault Description And Troubleshooting

If the device is not working properly, please read the following carefully for a solution.

MagiLens-0TXT10-High-Definition-Electronic-Digital-
Microscope-020

FCC Warning Statement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation
. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located for operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference
  2. This device must accept any interference received, including interference that may cause undesired operation.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals