Maretron TMP100 EGT Accessory Probe Downstream Instruction Manual
- June 16, 2024
- Maretron
Table of Contents
Instruction Manual
TMP100 EGT Accessory Probe Downstream
Can I install a Maretron TMP100 EGT accessory probe downstream of the
water-cooled exhaust riser or elbow?
Article Number: 489 | Rating: Unrated | Last Updated: Tue, Jul 28, 2015 7:51
PM
No. Maretron’s EGT sensor is meant to measure the temperature of the exhaust
gas temperature, not the temperature of the exhaust gas after it has been
cooled by water. Placing the EGT probe downstream of the riser or elbow will
render the device inoperative very quickly. When sulfuric dioxide in the
exhaust gas combines with water vapor at the riser or elbow, it forms sulfuric
acid. The sulfuric acid is extremely corrosive and it will destroy the EGT
probe.
The photo below shows the effects of a exposing an EGT probe to cooled exhaust
gas for a prolonged time.Posted – Tue, Nov 9, 2010 10:38 AM. This
article has been viewed 11055 times.
Online URL:
https://www.maretron.com/support/knowledgebase/phpkbv7/article.php?id=489
References
- TCPDF
- Can I install a Maretron TMP100 EGT accessory probe downstream of the water-cooled exhaust riser or elbow?
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>