FLOJET BevJet Compact Beverage Dispense Pump Instruction Manual

June 16, 2024
Flojet

FLOJET BevJet Compact Beverage Dispense Pump

BevJet Compact
Beverage Dispense Pump
INSTALLATION/OPERATION MANUAL

Beverage Dispense Pump

CAUTION: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Pump type Positive displacement diaphragm pump
Pump electrical ratings 12VDC 2.5 Amps max
Power supply adapter
  • Input: 100-240VAC or 12VDC (BLC9-series) /
  • Output: 12 VDC 3 Amp max

Flow rate| 1.0 GPM (3.8 LPM) max
Pressure switch shut off| 40 PSI (2.8 bar) max
Fluid contact materials| Polypropylene, EPDM, TPV, Stainless Steel
Ports included| 1/4” (6.35 mm) OD Push Fit
Fluid types (tested with water)| Water, soda, syrups, non-pulp juices, iced teas, wine, alcohol beverages < 15%, non particulate fluids, max viscosity 100cP
Liquid temperature| 34ºF (1.1ºC) – 120ºF (49ºC)
Net weight| 1 lb (632 g)

Application

  • Designed for dispensing Bag in Box beverages or Bottled Water as indicated in Product Data Section
  • Ideal for under counter installation

Special features

  • Quick, simple, safe installation
  • Compact size for easy mounting
  • Easily accessible manual on/off switch to restart the pump
  • Self priming
  • Able to run dry without damage
  • Quiet operation
  • Built in timer prevents unit from running dry longer than 1 minute
  • Built in shut-off automatically turns pump off after 5 minutes to prevent inadvertent continuous operation

Installation

Installation procedure: – See Figure 1

  1. Connect suction hose (6.35 mm 1/4”) to BIB or Bottle.
  2. Connect supplied power adaptor into the DC plug on the back of the BevJet Compact.
  3. Turn the ON/OFF switch located on the pump to the “ON” position.
  4. Open discharge valve to prime pump, and purge all air from the liquid line.

Operation: – See Figures 1 & 2

  • CAUTION: Do not place BevJet Compact into a dishwasher as it will cause electrical failure of pump and controls.
  • CAUTION: Not intended for outdoor use.
  • CAUTION: The BevJet Compact must be installed in an enclosure protected from any splash or spillage.
  • CAUTION: To avoid exposure to freezing conditions, prior to storing, cleaning and servicing of pumps, purge all liquid from the pump. Allowing water to freeze in the system may result in damage to the pump and plumbing system.
  • WARNING EXPLOSION HAZARD: Only used with specified products. DO NOT PUMP LIQUIDS WITH A FLASH POINT BELOW 100°F (37.8°C) OR USE WHERE FLAMMABLE VAPORS ARE PRESENT.

Figure 1 Typical Beverage Installations

Install port fittings and connect to suitably rated tubing
Note: Maximum run length is dependent on tubing diameter (Max 10ft total for 3/8” ID)

Figure 2 Operation

Performance Curve

Dimensions Inches [Millimeters]

Application Notes & Troubleshooting

System will not dispense fluid

  • Check ON/OFF switch position.
  • Check power to dispensing system.
  • Check tubing and fluid connections
  • Check for empty fluid container.
  • 1 min. dry or 5 min. wet cycle time exceeded.— I/O light flashing on pump rocket switch— Cycle on/off switch to reset

System will not shut-off

  • Check for leaks in tubing system.
  • Check for air in system, purge air.

System continually turns OFF and ON while in use

  • Check for system tubing restriction in tubing or kinked hose.
  • Tubing size too small or excessive length

BevJet Compact Parts List Kits

| US Versions| UK Versions| EU Versions| AU Versions| 12Vdc Version
---|---|---|---|---|---
| BLC10110xxx| BLC20110xxA| BLC30110xxA| BLC40110xxA| BLC9011xxA
Transformer| 20465015E| 20465025| 20465030| 20465020| 20030706A
Faucet| 21000769| 21000769| 21000769| 21000769| 21000769

Available Liquid Port Kits

WARRANTY

  • XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORKMANSHIP FOR A PERIOD OF 1 YEAR FROM DATE OF MANUFACTURE.
  • THE WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER
  • NATURE RELATING TO THE GOODS PROVIDED HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND
  • FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED. EXCEPT AS OTHER-WISE PROVIDED BY LAW, BUYER’S
  • EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING
  • THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT PAID BY THE BUYER HEREUNDER. IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT
  • LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION. THIS WARRANTY IS ONLY A REPRESEN-TATION OF THE COMPLETE LIMITED WARRANTY. FOR A DETAILED EXPLANATION, PLEASE
  • VISIT US AT www.xylem.com/en-us/support/, CALL OUR OFFICE NUMBER LISTED, OR WRITE A LETTER TO YOUR REGIONAL OFFICE.

RETURN PROCEDURE
Warranty returns are conducted through the place of purchase. Please contact the appropriate entity with a receipt of purchase to verify date.

  • Xylem Inc. — USA
    • 17942 Cowan
    • Irvine, CA 92614
    • Xylem Inc. — UK
    • Harlow Innovation Park,
    • London Road, Harlow, Essex, CM17 9LX
    • Xylem Inc. — CHINA
    • 30/F Tower A, 100 Zunyi Road, Shanghai 200051
  • www.xylem.com/flojet
    • © 2022 Xylem Inc. All rights reserved
    • Flojet is a trademark of Xylem Inc. or one of its subsidiaries 81000451 Rev. E 09/2022

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals