Connect Tech Inc Xtreme 10G Managed Ethernet Switch Router User Guide

June 16, 2024
Connect Tech Inc

Connect Tech Inc Xtreme 10G Managed Ethernet Switch Router

Product Information

Specifications

FAQ

  • Q: How do I access the CLI Management Interface?
    • A: You can access the CLI Management Interface by connecting  your computer to the device’s serial port using a serial cable and  using a terminal emulator program.
  • Q: Where can I find more information about the available commands?
    • A: For detailed information on the available commands and their  usage, please refer to the “Complete CLI and Protocol Configuration Reference Guide.”

Preface

Disclaimer

The information contained within this user’s guide, including but not limited to any product specification, is subject to change without notice. Connect Tech assumes no liability for any damages incurred directly or indirectly from any technical or typographical errors or omissions contained herein or for discrepancies between the product and the user’s guide.

Customer Support Overview

If you experience difficulties after reading the manual and/or using the product, contact the Connect Tech reseller from which you purchased the product. In most cases the reseller can help you with product installation and difficulties. In the event that the reseller is unable to resolve your problem, our highly qualified support staff can assist you. Our support section is available 24 hours a day, 7 days a week on our website at: http://connecttech.com/support/resource-center/. See the contact information section below for more information on how to contact us directly. Our technical support is always free.

Contact Information

Mail/Courier

  • Connect Tech Inc. Technical Support 42 Arrow Road Guelph, Ontario Canada N1K 1S6

Email/Internet

Note: Please go to the Connect Tech Resource Center for product manuals, installation guides, device drivers, BSPs and technical tips. Submit your technical support questions to our support engineers.

Telephone/Facsimile

Technical Support representatives are ready to answer your call Monday through Friday, from 8:30 a.m. to 5:00 p.m. Eastern Standard Time. Our numbers for calls are:

  • Toll Free: 800-426-8979 (North America only)
  • Telephone: 519-836-1291 (Live assistance available 8:30 a.m. to 5:00 p.m. EST, Monday to Friday)
  • Facsimile: 519-836-4878 (on-line 24 hours)

Limited Product Warranty

Connect Tech Inc. provides a one year Warranty for the Xtreme/10G Managed Ethernet Switch/Router. Should this product, in Connect Tech Inc.’s opinion, fail to be in good working order during the warranty period, Connect Tech Inc. will, at its option, repair or replace this product at no charge, provided that the product has not been subjected to abuse, misuse, accident, disaster or non-Connect Tech Inc. authorized modification or repair.

You may obtain warranty service by delivering this product to an authorized Connect Tech Inc. business partner or to Connect Tech Inc. along with proof of purchase. Product returned to Connect Tech Inc. must be pre-authorized by Connect Tech Inc. with an RMA (Return Material Authorization) number marked on the outside of the package and sent prepaid, insured and packaged for safe shipment. Connect Tech Inc. will return this product by prepaid ground shipment service.  The Connect Tech Inc. Limited Warranty is only valid over the serviceable life of the product. This is defined as the period during which all components are available. Should the product prove to be irreparable, Connect Tech Inc. reserves the right to substitute an equivalent product if available or to retract the Warranty if no replacement is available.

The above warranty is the only warranty authorized by Connect Tech Inc. Under no circumstances will Connect Tech Inc. be liable in any way for any damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use of, or inability to use, such product.

Copyright Notice

The information contained in this document is subject to change without notice. Connect Tech Inc. shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Connect Tech, Inc.

Copyright © 2017 by Connect Tech, Inc.

Trademark Acknowledgment

Connect Tech, Inc. acknowledges all trademarks, registered trademarks and/or copyrights referred to in this document as the property of their respective owners. Not listing all possible trademarks or copyright acknowledgments does not constitute a lack of acknowledgment to the rightful owners of the trademarks and copyrights mentioned in this document.

ESD Warning

Electronic components and circuits are sensitive to ElectroStatic Discharge (ESD). When handling any circuit board assemblies including Connect Tech carrier assemblies, it is recommended that ESD safety precautions be observed. ESD safe best practices include, but are not limited to:

  • Leaving circuit boards in their antistatic packaging until they are ready to be installed.
  • Using a grounded wrist strap when handling circuit boards, at a minimum you should touch a grounded metal object to dissipate any static charge that may be present on you.
  • Only handling circuit boards in ESD safe areas, which may include ESD floor and table mats, wrist strap stations and ESD safe lab coats.
  • Avoiding handling circuit boards in carpeted areas.
  • Try to handle the board by the edges, avoiding contact with components.

Revision History

Revision Date Changes
0.00 2016-06-15 Never Released
0.01 2016-08-18 Initial Release
0.02 2017-05-30 Updated B2B Connector Pinout Table
0.03 2017-07-25 –          Corrected pin definitions of D69 and D68 in the

B2B Pinout Table

–          Added additional information on breakout board options and their corresponding reference design package.

0.04| 2017-07-27| –       Vitesse Firmware version change, default IP now set to 10.10.10.1
0.05| 2017-08-04| Added heatplate drawing link, removed drawing from doc
0.06| 2017-09-11| –          Fixed XDG201 3D Model Link

–          Added KDB entry on SFP+ CU Transceiver Compatibility

0.07| 2018-05-15| Edited KDB link on SFP+ CU Transceiver Compatibility
0.08| 2019-07-09| Corrected port speeds

Introduction

Connect Tech’s Xtreme/10G Managed Ethernet Switch (XDG201) provides high density, high port count Layer 2 switching and Layer 3 routing with 10G uplinks. A total of 36 switchable ports, with 4 x 10G, 8 x 1G (SGMII) and 24 x 1G (Copper 10/100/1000Mbps) Ports in an extremely small form factor 85mm x 85mm. The devices target managed Layer 2 and Layer 3 equipment in SMB, SME, and industrial applications where high port count 1G switching with 10G aggregation/uplinks are required.
The XDG201 is a Network Switching Module. This module is of a proprietary form factor and contains a board-to-board connector that allows it to be integrated into an off the shelf carrier like the XBG301 or other custom/application specific carrier.

Product Features and Specifications

Feature Description
Ethernet Switch Engine Vitesse VSC7448 Carrier Grade Ethernet Switch

Chipset
Ports| 36 Total Switching Ports

4 x 10G (SFI) Ports

8 x 1G (SGMII) Ports

24 x 1G (Copper 10/100/1000Mbps) Ports


Note: All ports are exposed over the proprietary module board-to-board connector; physical interface must be implemented on carrier board.

Memories| 4Gb DDR3 SDRAM

128Mb Serial NOR Flash

I/O Connectors| High-Density 440-pin Board-to-Board Connector
Layer 2 & Layer 3 Forwarding| IEEE802.1Q switch with 4K VLANs and 32K MAC table entries
Push/pop up to 3VLAN tags on ingress and egress
RSTP and MSTP support
Fully non-blocking wire-speed switching performance for all frame sizes
IPv4/IPv6 unicast and multicast Layer 2 switching with up to 32K groups and 1K port masks
IPv4/IPv6 unicast and multicast Layer 3 forwarding (routing) with reverse path forwarding (RPF) support
IGMPv2, IGMPv3, MLDv1, and MLDv2 support
Link aggregation (IEEE 802.3ad)
Independent and shared VLAN learning (IVL, SVL)
Jumbo frame support
Quality of Service| Four megabytes of integrated shared packet memory Eight QoS classes with a pool of up to 32K queues

TCAM-based classification with pat tern matching against Layer 2 through Layer 4 Information

Dual- rate policers selected by VCAP IS2, eight single- rate priority policers per port, and four single-rate port policers for each port

Flexible 4K ingress QoS mappings and 8K egress QoS mappings for VLAN tags and DSCP values

Up to 4K egress VLAN tag operat ions

Audio/ video bridging (AVB) with support for time-synchronized, low- latency and video streaming services

Priority-based f low control (PFC) ( IEEE 802.1Qbb)

Security| Vitesse Content Aware Processor (VCAP™) packet filtering engine using ACLs for ingress and egress packet inspection

Storm controllers for flooded broadcast, flooded multicast , and flooded unicast traffic Per-port, per-address registration for copying/redirecting/discarding

32 VCAP single-rate policers

Maximum Bandwidth| 80Gbps
Layer 2 Switching Parameters| Packet Buffer: 32Mb

MAC Table Size:                      32k Layer 2 Multicast Port Masks:    1k Super VCAP blocks:                 8

VCAP CLM entries:                  4k

VCAP LPM entries:                  4k/1k (IPv4/IPv6)

VCAP IS2 entries:                    4k/1k (IPv4/IPv6)

Layer 3 Routing Parameters| Router Legs:                             128

IP unicast routes/hosts:              4k/1k (IPv4/IPv6) Next -hop/ ARP table entries:     2k

IP multicast groups:                   2k/512 Multicast router leg masks: 1k

ECMPs:                                    16

---|---
Management Access| Web Interface CLI via RS-232

Software API SMNP

Input Voltage| +4V to 14V Input Range (External Connector)
Power Consumption| 24W Max / 14W Idle
Dimensions| 85mm x 85mm
Weight| TBD
MTBF| TBD
Operating Temp| -40°C to +85°C (chipset rated to +125°C thermals)
Warranty and Support| 1 Year Warranty and Free Technical Support

Product Overview

Block Diagram

Connector Locations

Top Side

Bottom Side

Connector Summary

Designator Connector Description
P1 Main Board-to-Board Primary Signal and Power Breakout Connector

Switch Summary & Locations

Designator Function Description
S1 Config Switch Used to Put Switch in to Manual Reset Mode

Detailed Feature Description

Main Board-to-Board Connector

The Main Board-to-Board connector carries:

  • Input power from the carrier to the module
  • Power control and reset signals
  • 24x 1G copper pairs, for termination to RJ-45s on carrier board
  • 4x 10G for connection to SFP+ on the carrier board
  • 8x 1G for connection to SFP on the carrier board
  • LED management signal chain
  • SFP detection and control chain

LED and SFP management signals chains required specific circuitry on the carrier; see the reference design for details.

Function| Primary Signal and Power Breakout|

---|---|---
Location| P1
XDG201 Module Connector| Primary Part

Manufacturer: TE Connectivity Part Number: 3-1827231-6

Cross Reference 1 Manufacturer: FCI Part Number: TBD

Carrier Board Mating Connector| Primary Part

Manufacturer: TE Connectivity Part Number: 3-5353652-6

Cross Reference 1 Manufacturer: FCI Part Number: TBD

Pinout Table

GND A110
1GF-P7-RXD_P A109
1GF-P7-RXD_N A108
GND A107
1GF-P6-RXD_P A106
1GF-P6-RXD_N A105
GND A104
1GF-P5-RXD_P A103
1GF-P5-RXD_N A102
GND A101
GND A100
1GF-P4-RXD_P A99
1GF-P4-RXD_N A98
GND A97
1GF-P3-RXD_P A96
1GF-P3-RXD_N A95
GND A94
1GF-P2-RXD_P A93
1GF-P2-RXD_N A92
GND A91
GND A90
1GF-P1-RXD_P A89
1GF-P1-RXD_N A88
GND A87
1GF-P0-RXD_P A86
1GF-P0-RXD_N A85
GND A84
RESET#_IN A83
RESET#_OUT A82
PWROK_IN A81
GND A80
EE_WP# A79
NAND_WP# A78
Reserved A77
Reserved A76
Reserved A75
Reserved A74
Reserved A73
Reserved A72
Reserved A71
GND A70
1GC-P15-D3_P A69
1GC-P15-D3_N A68
1GC-P15-D2_P A67
1GC-P15-D2_N A66
1GC-P15-D1_P A65
1GC-P15-D1_N A64
1GC-P15-D0_P A63
1GC-P15-D0_N A62
GND A61
GND A60
1GC-P16-D3_P A59
1GC-P16-D3_N A58
1GC-P16-D2_P A57
1GC-P16-D2_N A56
1GC-P16-D1_P A55
1GC-P16-D1_N A54
1GC-P16-D0_P A53
1GC-P16-D0_N A52
GND A51
1GC-P17-D3_P A50
1GC-P17-D3_N A49
1GC-P17-D2_P A48
1GC-P17-D2_N A47
1GC-P17-D1_P A46
1GC-P17-D1_N A45
1GC-P17-D0_P A44
1GC-P17-D0_N A43
GND A42
GND A41
1GC-P18-D3_P A40
1GC-P18-D3_N A39
1GC-P18-D2_P A38
1GC-P18-D2_N A37
1GC-P18-D1_P A36
1GC-P18-D1_N A35
1GC-P18-D0_P A34
1GC-P18-D0_N A33
GND A32
GND A31
1GC-P19-D3_P A30
1GC-P19-D3_N A29
1GC-P19-D2_P A28
1GC-P19-D2_N A27
1GC-P19-D1_P A26
1GC-P19-D1_N A25
1GC-P19-D0_P A24
1GC-P19-D0_N A23
GND A22
GND A21
1GC-P20-D3_P A20
1GC-P20-D3_N A19
1GC-P20-D2_P A18
1GC-P20-D2_N A17
1GC-P20-D1_P A16
1GC-P20-D1_N A15
1GC-P20-D0_P A14
1GC-P20-D0_N A13
GND A12
GND A11
+3V3_OUT A10
+3V3_OUT A9
GND A8
+VIN A7
+VIN A6
+VIN A5
+VIN A4
+VIN A3
+VIN A2
GND A1
B110 GND
--- ---
B109 1GF-P7-TXD_P
B108 1GF-P7-TXD_N
B107 GND
B106 1GF-P6-TXD_P
B105 1GF-P6-TXD_N
B104 GND
B103 1GF-P5-TXD_P
B102 1GF-P5-TXD_N
B101 GND
B100 GND
B99 1GF-P4-TXD_P
B98 1GF-P4-TXD_N
B97 GND
B96 1GF-P3-TXD_P
B95 1GF-P3-TXD_N
B94 GND
B93 1GF-P2-TXD_P
B92 1GF-P2-TXD_N
B91 GND
B90 GND
B89 1GF-P1-TXD_P
B88 1GF-P1-TXD_N
B87 GND
B86 1GF-P0-TXD_P
B85 1GF-P0-TXD_N
B84 GND
B83 UART_TX
B82 UART_RX
B81 PWROK_OUT
B80 GND
B79 Reserved
B78 Reserved
B77 Reserved
B76 Reserved
B75 Reserved
B74 Reserved
B73 Reserved
B72 Reserved
B71 Reserved
B70 GND
B69 1GC-P12-D3_P
B68 1GC-P12-D3_N
B67 1GC-P12-D2_P
B66 1GC-P12-D2_N
B65 1GC-P12-D1_P
B64 1GC-P12-D1_N
B63 1GC-P12-D0_P
B62 1GC-P12-D0_N
B61 GND
B60 GND
B59 1GC-P13-D3_P
B58 1GC-P13-D3_N
B57 1GC-P13-D2_P
B56 1GC-P13-D2_N
B55 1GC-P13-D1_P
B54 1GC-P13-D1_N
B53 1GC-P13-D0_P
B52 1GC-P13-D0_N
B51 GND
B50 1GC-P14-D3_P
B49 1GC-P14-D3_N
B48 1GC-P14-D2_P
B47 1GC-P14-D2_N
B46 1GC-P14-D1_P
B45 1GC-P14-D1_N
B44 1GC-P14-D0_P
B43 1GC-P14-D0_N
B42 GND
B41 GND
B40 1GC-P21-D3_P
B39 1GC-P21-D3_N
B38 1GC-P21-D2_P
B37 1GC-P21-D2_N
B36 1GC-P21-D1_P
B35 1GC-P21-D1_N
B34 1GC-P21-D0_P
B33 1GC-P21-D0_N
B32 GND
B31 GND
B30 1GC-P22-D3_P
B29 1GC-P22-D3_N
B28 1GC-P22-D2_P
B27 1GC-P22-D2_N
B26 1GC-P22-D1_P
B25 1GC-P22-D1_N
B24 1GC-P22-D0_P
B23 1GC-P22-D0_N
B22 GND
B21 GND
B20 1GC-P23-D3_P
B19 1GC-P23-D3_N
B18 1GC-P23-D2_P
B17 1GC-P23-D2_N
B16 1GC-P23-D1_P
B15 1GC-P23-D1_N
B14 1GC-P23-D0_P
B13 1GC-P23-D0_N
B12 GND
B11 GND
B10 +3V3_OUT
B9 +3V3_OUT
B8 GND
B7 +VIN
B6 +VIN
B5 +VIN
B4 +VIN
B3 +VIN
B2 +VIN
B1 GND
GND C110
--- ---
GND C109
10G-P3-RXD_P C108
10G-P3-RXD_N C107
GND C106
GND C105
10G-P2-RXD_P C104
10G-P2-RXD_N C103
GND C102
GND C101
GND C100
GND C99
10G-P1-RXD_P C98
10G-P1-RXD_N C97
GND C96
GND C95
10G-P0-RXD_P C94
10G-P0-RXD_N C93
GND C92
GND C91
GND C90
SGPIO2_DI C89
SGPIO2_LD C88
SGPIO2_DO C87
SGPIO2_CLK C86
SFP+D_SCL C85
SFP+C_SCL C84
SFP+B_SCL C83
SFP+A_SCL C82
PUSHBUTTON# C81
GND C80
Reserved C79
Reserved C78
Reserved C77
Reserved C76
Reserved C75
Reserved C74
Reserved C73
Reserved C72
Reserved C71
GND C70
1GC-P3-D3_P C69
1GC-P3-D3_N C68
1GC-P3-D2_P C67
1GC-P3-D2_N C66
1GC-P3-D1_P C65
1GC-P3-D1_N C64
1GC-P3-D0_P C63
1GC-P3-D0_N C62
GND C61
GND C60
1GC-P4-D3_P C59
1GC-P4-D3_N C58
1GC-P4-D2_P C57
1GC-P4-D2_N C56
1GC-P4-D1_P C55
1GC-P4-D1_N C54
1GC-P4-D0_P C53
1GC-P4-D0_N C52
GND C51
1GC-P5-D3_P C50
1GC-P5-D3_N C49
1GC-P5-D2_P C48
1GC-P5-D2_N C47
1GC-P5-D1_P C46
1GC-P5-D1_N C45
1GC-P5-D0_P C44
1GC-P5-D0_N C43
GND C42
GND C41
1GC-P6-D3_P C40
1GC-P6-D3_N C39
1GC-P6-D2_P C38
1GC-P6-D2_N C37
1GC-P6-D1_P C36
1GC-P6-D1_N C35
1GC-P6-D0_P C34
1GC-P6-D0_N C33
GND C32
GND C31
1GC-P7-D3_P C30
1GC-P7-D3_N C29
1GC-P7-D2_P C28
1GC-P7-D2_N C27
1GC-P7-D1_P C26
1GC-P7-D1_N C25
1GC-P7-D0_P C24
1GC-P7-D0_N C23
GND C22
GND C21
1GC-P8-D3_P C20
1GC-P8-D3_N C19
1GC-P8-D2_P C18
1GC-P8-D2_N C17
1GC-P8-D1_P C16
1GC-P8-D1_N C15
1GC-P8-D0_P C14
1GC-P8-D0_N C13
GND C12
GND C11
+3V3_OUT C10
+3V3_OUT C9
GND C8
+VIN C7
+VIN C6
+VIN C5
+VIN C4
+VIN C3
+VIN C2
GND C1
D110 GND
--- ---
D109 GND
D108 10G-P3-TXD_P
D107 10G-P3-TXD_N
D106 GND
D105 GND
D104 10G-P2-TXD_P
D103 10G-P2-TXD_N
D102 GND
D101 GND
D100 GND
D99 GND
D98 10G-P1-TXD_P
D97 10G-P1-TXD_N
D96 GND
D95 GND
D94 10G-P0-TXD_P
D93 10G-P0-TXD_N
D92 GND
D91 GND
D90 GND
D89 I2C_SDA
D88 I2C_SCL
D87 MUX_SEL2
D86 MUX_SEL1
D85 MUX_SEL0
D84 SLED1_DO
D83 SLED1_CLK
D82 SLED0_DO
D81 SLED0_CLK
D80 GND
D79 Reserved
D78 Reserved
D77 Reserved
D76 Reserved
D75 Reserved
D74 Reserved
D73 Reserved
D72 Reserved
D71 Reserved
D70 GND
D69 1GC-P0-D3_P
D68 1GC-P0-D3_N
D67 1GC-P0-D2_P
D66 1GC-P0-D2_N
D65 1GC-P0-D1_P
D64 1GC-P0-D1_N
D63 1GC-P0-D0_P
D62 1GC-P0-D0_N
D61 GND
D60 GND
D59 1GC-P1-D3_P
D58 1GC-P1-D3_N
D57 1GC-P1-D2_P
D56 1GC-P1-D2_N
D55 1GC-P1-D1_P
D54 1GC-P1-D1_N
D53 1GC-P1-D0_P
D52 1GC-P1-D0_N
D51 GND
D50 1GC-P2-D3_P
D49 1GC-P2-D3_N
D48 1GC-P2-D2_P
D47 1GC-P2-D2_N
D46 1GC-P2-D1_P
D45 1GC-P2-D1_N
D44 1GC-P2-D0_P
D43 1GC-P2-D0_N
D42 GND
D41 GND
D40 1GC-P9-D3_P
D39 1GC-P9-D3_N
D38 1GC-P9-D2_P
D37 1GC-P9-D2_N
D36 1GC-P9-D1_P
D35 1GC-P9-D1_N
D34 1GC-P9-D0_P
D33 1GC-P9-D0_N
D32 GND
D31 GND
D30 1GC-P10-D3_P
D29 1GC-P10-D3_N
D28 1GC-P10-D2_P
D27 1GC-P10-D2_N
D26 1GC-P10-D1_P
D25 1GC-P10-D1_N
D24 1GC-P10-D0_P
D23 1GC-P10-D0_N
D22 GND
D21 GND
D20 1GC-P11-D3_P
D19 1GC-P11-D3_N
D18 1GC-P11-D2_P
D17 1GC-P11-D2_N
D16 1GC-P11-D1_P
D15 1GC-P11-D1_N
D14 1GC-P11-D0_P
D13 1GC-P11-D0_N
D12 GND
D11 GND
D10 +3V3_OUT
D9 +3V3_OUT
D8 GND
D7 +VIN
D6 +VIN
D5 +VIN
D4 +VIN
D3 +VIN
D2 +VIN
D1 GND

Board-to-Board Reference Design Package

  • Connect Tech Product a complete reference design package for the XBG301 breakout board.
  • This details how to properly interface to the XDG201 Switch.

This package contains the following for the XBG301 Breakout Board:

  • Altium Designer ECAD Source Files
  • PDF Schematic Files
  • Gerbers / Manufacturing Files
  • Bill of Materials
  • Tech Data / B2B Pinout Information
  • 3D Models (as well for the Switch Module and Heatspreader)

The Reference Design Package can be downloaded here:

SFP and SFP+ CU Transceiver Support

The XDG201 has support for the CISCO Compatible/ Equivalent GLC-T, additional support for CU transceivers can be found in the following link. http://connecttech.com/resource-center/kdb360-xtreme10g-managed-ethernet- switchrouter-sfpsfp-transceivermodules/

Switch Details And Typical Installation

Switch Details

DIP Switch Details (S1)

  • Ensure – S1 Lower Switch Position is set to “RUN” at all times.
  • Moving the switch to “RESET” will hold the entire device in RESET and will prevent the board from booting.

Typical Installation

  1. Install XHG201 heatplate to XDG201 module.
  2. Prepare breakout/carrier board with 4 x M3 8mm standoffs.
  3. Ensure breakout/carrier board will be supplying module with +12V DC.
  4. Mate board-to-board connector from XDG201 module to that of the breakout/carrier board.
  5. Turn power ON to breakout/carrier board, XDG201 will now boot up.

On-Board Indicator LED’s

The XDG201 has 2 on-board indicator LEDs.

LED Designator Description
PWR Power Good Indicator

–       If this LED is ON, this indicates that all on-board power supplies are ON and at the proper level.

Status| System Status Indicator

–       Function TBD

CLI Management Interface

CLI Access via External Serial Port

To use the CLI management on the XDG you must connect to the external management serial port. Only TX, RX and GND connections are needed for operation. You then must open the serial port in a terminal program such as: RealTerm, Putty, HyperTerminal, minicom, etc. The COM port must be set up to run with a baud rate of 115200, 8 data bits, 1 stop bit and no parity.

RS-232 Serial Parameter Value
Baud Rate 115200 bps
Data Bits 8
Parity None
Stop Bit 1

CLI Basics

Once opening the COM port attached to the management port, after boot up your terminal output should look like the output below. The default login is admin and password is blank(“”). So after typing admin hit then hit again to login and “?” will display a list of the available commands. Below is a list of common quick CLI commands. For a complete CLI reference please see the documents described below.

Common Task CLI Command Syntax
What are the IP addresses used by my switch? show ip int br
What ports are linked and at what speed? show int * status
What software version is on my switch? show ver
How do I save my configuration? copy running-config startup-config
How do I setup my IP address for vlan1? conf t

int vlan 1

ip add xxx.xxx.xxx.xxx 255.255.255.0

end

Complete CLI and Protocol Configuration Reference Guide

The complete CLI and Protocol Configuration reference guide from Microsemi for the VSC7448 device can be downloaded here.

The following documents:

  • AN1104-Software_Configuration_Guide_ICLI –
  • AN1115Layer2ProtocolConfigurationGuide

Will have the below mentioned copyright notice.

Copyright 2002-2015 Microsemi Corporation. All Rights Reserved. Unpublished rights reserved under the copyright laws of the United States of America, other countries and international treaties. Microsemi retains all ownership, copyright, trade secret and proprietary rights in the documentation.

Web Management Interface

  • The Xtreme/10G Managed Ethernet Switch/Router allows users to configure and monitor the device from any web enabled device.
  • Below describes how to access this management interface as well as provides on overview on the web GUI itself.

Accessing the Web Management Interface

There are two ways to access the web interface for first time use.

Method #1 – Using the default shipping IP

This method DOES NOT require having access to the CLI interface. By default the Xtreme/10G will have an IP address of 10.10.10.1, if you would like to connect to this address follow the steps below:

  • Directly connect any port of Xtreme/10G to your host PC using a standard Cat5e ethernet cable
  • Setup your host PC’s IP address to be on the same subnet as Xtreme/10G (10.10.10.X)
  • Open a web browser and go to the 10.10.10.1 address.
  • Now you should see the login screen and from here you can setup the Xtreme/10G to an IP address on your network.

Method #2 – Changing the Xtreme/10G IP to one on your network via the CLI

This method requires having access to the CLI interface through means of the external management serial port or the PCIe/104 bus

  • Login to the CLI interface
  • Type in the following commands
  • configure terminal
  • interface vlan 1
  • ip address xxx.xxx.xxx.xxx 255.255.255.0
  • end
  • Now connect Xtreme/10G to any place on your network.
  • Once the system is up simply go to your specified address of xxx.xxx.xxx.xxx in a web browser of your choice and you will see the login screen for the web interface

Login Screen of Web Management Interface

To login into the web management interface, the default login is admin and the password is blank. (See below)

Web Management Interface Overview

Complete Web Protocol Configuration Reference Guide

As mentioned in the CLI section, the complete Protocol Configuration reference guide from Microsemi for the VSC7429 device can be downloaded here. It will have CLI and Web configuration methods listed.

The following document:

  • AN1115Layer2ProtocolConfigurationGuide

Will have the below mentioned copyright notice.

Copyright 2002-2015 Microsemi Corporation. All Rights Reserved. Unpublished rights reserved under the  copyright laws of the United States of America, other countries and international treaties. Microsemi retains all ownership, copyright, trade secret and proprietary rights in the documentation.

Breakout Boards

The XDG201 product can be integrated into any custom designed motherboard, or custom design breakout specifically for the XDG201. It can also be used with CTI’s line of COTS breakout boards as well, so that no additional development is needed. These COTS breakout boards can be used for proof of concept or for direct field deployment.

XBG301 – Embedded Carrier

CTI has developed the XBG301, which is a COTS breakout board solution for the XDG201 switch. This breakout board is also meant to serve as a Reference Design platform for customers to use for their own development purposes. CTI provides full Bill of Materials, Schematics, Layout files and user documentation for the XBG301 embedded carrier in a Reference Design Package.

The Reference Design Package for this breakout board be downloaded here:http://www.connecttech.com/ftp/Reference_Designs/XBG301_Reference_Design_Package.zip

XBG301 – Embedded Carrier Specifications

Feature Description
Ports 4x 10G (SFP+)

4x 1G (SFP)

24x 1G (RJ-45)

Console| 1x RS-232 (via DB-9)
Input Voltage| +5V to +14V DC (4-pin 5mm pitch terminal header)
Dimensions| 167.07mm x 125.84mm x 49.10mm (when XDG201 + XHG201 heat spreader are installed)
Console| 1x RS-232 (via DB-9)

XBG301 +XDG201 + XHG201 – Dimensioned Drawing

XBG301 +XDG201 + XHG201 – Assembly Drawing

Thermal Details

XDG201 Thermal Parameters

Thermal Parameter Value
Minimum Ambient Operating Temperature -40 °C
Maximum Operating Junction Temperature of all chipsets 125 °C
Total Solution TDP 24 W
Die junction to package case top (SoC/PHY) 3.27 °C/W
Die junction to PCB (SoC/PHY) 6.03 °C/W
Die junction to Ambient (SoC/PHY) 12.14 °C/W
Die junction to moving air @ 1 m/s (SoC/PHY) 9.42 °C/W

XHG201 – Conduction Cooled Heatplate

  • The XHG201 is a flat heatplate that can be used to interface the XDG201 to another thermal extraction layer  (chassis wall, finned heat sink etc).
  • It is not intended to be used in a standalone application. View the heatplate drawing.

Current Consumption Details

Below are the maximum ratings of the XDG201 Switch.

Theoretical Maximum Amps Watts
Theoretical absolute maximum total draw of all functionality on the board
2.00 24

Below are measurements taken with the XDG201 Switch running in various configurations.
All measurements below are used with +12V applied to the Input Power Connector.

Actual Measurements Amps Watts
Idle No Links Up 1.17 14.04
1x 1G Link Up 1.20 14.40
24 x 1G Links Up 1.76 21.12
24 x 1G, 4 x 1G SFP, 4 x 10G SFP+ Up 1.81 21.72

Mechanical Details

3D Model

Download Link: http://www.connecttech.com/ftp/3d_models/XDG201_3D_MODEL.zip

2D Drawing (Top Side)

  • Dimensions in millimeters

2D Drawing (Bottom Side)

Dimensions in millimeters – Location of Pin 1 detailed below

Contact

Connect Tech Inc

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Connect Tech Inc User Manuals

Related Manuals