U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator User Guide

June 16, 2024
U-Line

U-LINE logo USER GUIDE &
SERVICE MANUALU-LINE UORE124-SS01A 24 Inch Outdoor
RefrigeratorModel:
UORE124-SS01A

WELCOME TO U-LINE
Congratulations on your U-Line purchase! Your product comes from a company with decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA height compliant, marine, and commercial. Product categories include Beverage Centers, Wine Refrigerators, Ice Machines, Refrigerators, Freezers, and Dispensers. Our advanced refrigeration systems, large and flexible capacities, and clean integrated look are what makes our products Built-In to Stand Out®. Since 2014, U-Line has been part of the Middleby family of brands. Products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.

U-Line — RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE.®
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, and Product Warranty information are available digitally on u-line.com.

PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following steps:

  1. U-Line Customer Care must be contacted immediately at +1.414.354.0300.
  2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.

Safety

Safety and Warning

NOTICE
Please read all instructions before installing, operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger, Warning, or Caution based on the risk type:

DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury or death.
CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property, or equipment damage.
DANGER
This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the “R600a specifications” section included in the User Guide. Do not damage the refrigerant circuit.
WARNING
Service must be done by factory authorized service personnel. Any parts shall be replaced with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service.
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. www.P65warnings.CA.gov
CAUTION
This equipment is to be installed with adequate backflow protection to comply with applicable federal, state and local codes.

Disposal and Recycling
DANGER
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.
If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:

  1. Remove all consumable contents from the unit.
  2. Unplug the electrical cord from its socket.
  3. Remove the door(s)/drawer(s).

Installation

Environmental Requirements
This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
In climates where high humidity and dew points are present, condensation may appear on outside surfaces.
This is considered normal. The condensation will evaporate when the humidity drops.

CAUTION
Damages caused by ambient temperatures of 40°F (4°C) or below are not covered by the warranty.

Electrical
WARNING
SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. A GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping. However, be sure to consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended receptacle location.

Cutout & Product Dimensions
PREPARE SITE
Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit  does not require additional air space for top, sides, orrear. However, the front grille must NOT be obstructed, and clearance is required for an electrical connection in the rear.

CAUTION
Unit can NOT be installed behind a closed cabinet door.
CUTOUT DIMENSIONS

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Product
Dimensions *24” cutout width sufficient if door protrudes beyond adjacent cabinetry

PRODUCT DIMENSIONS
REAR

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator -
REARU-LINE UORE124-SS01A 24 Inch Outdoor
Refrigerator - REAR 1

Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the cutout dimension of a single unit times two.
No trim kit is required. However, 1/4″ (6 mm) of space needs to be maintained between the units to ensure unobstructed door swing.
Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s electrical specifications requirements.

Side-by-Side Installation with Bracket

  1. Slide both units out so screws on top of units are easily accessible.

  2. Remove screws as shown below.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Side Installation

  3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
    Tighten screws fully.

  4. Gently push units into position. Be careful not to entangle the electrical cord or water line, if applicable.

  5. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1/8″ (3 mm) below the countertop.

Anti-Tip Bracket

  1. Slide unit out so screws on top of unit are easily accessible.

  2. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below).U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Tip Bracket

  3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
    Tighten screws fully.

  4. Gently push unit into position. Be careful not to entangle the electrical cord or water line, if applicable.

  5. Check to be sure the unit is level from front to back and side to side. Make any necessary adjustments.
    The unit’s top surface should be approximately 1⁄8” (3 mm) below the countertop.

  6. Secure bracket into adjoining surface.

General Installation
LEVELING INFORMATION

  1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - General Installation
  2. If the unit is not level, adjust the legs on the corners of the unit as necessary. U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - General Installation 1
  3. Confirm the unit is level after each adjustment and repeat the previous steps as needed.

INSTALLATION TIP
If the room floor is higher than the floor in the cutout opening, adjust the rear legs to achieve a total unit rear height of 1⁄8” (3 mm) less than opening’s rear height.
Shorten the unit height in the front by adjusting the front legs. This allows the unit to be gently tipped into the opening. Readjust the front legs to level the unit after it is correctly positioned in the opening.

INSTALLATION

  1. Plug in the power/electrical cord.
  2. Gently push the unit into position. Be careful not to entangle the cord or water and drain lines, if applicable.
  3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1⁄8” (3 mm) below the countertop.
  4. Install the anti-tip bracket.
  5. Remove interior packing material and wipe out the inside of the unit with a clean, water-dampened cloth.

Grille Installation
REMOVING AND INSTALLING GRILLE
WARNING
Disconnect electric power to the unit before removing the grille.
When using the unit, the grille must be installed.
WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

Removing the grille

  1. Disconnect power to the unit.
  2. Loosen the two screws (1).
  3. Remove grille (2) from unit.

Installing the grille

  1. Align cabinet and grille holes and secure, but do not over tighten grille screws (1).
    Note: When installing next to a 15” wide U-Line product, use the supplied spacers behind the grille. The 24” grille will now be on the same plane as the 15” grille.

  2. Reconnect power to the unit.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Grille Installation

Door SwingU-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Door
Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets.
Stainless Steel models require 2-1/8″ (54 mm) door clearance to accommodate the handle if installed next to a wall.

Door Adjustments
HINGE COVER
Hinge cover included with the literature bag is optional.

To install hinge cover:

  1.  Press hinge cover squarely over hinge.

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Door
Adjustments

DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool properly, or excessive frost may form in the interior.
NOTICE
Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to ensure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the hinge side of the door.

To align and adjust the door:

  1. Gently pry off hinge cover from top of unit.
  2. Loosen (do not remove) top and bottom hinge screws using a Torx T-25 screwdriver.
  3. Align door squarely with cabinet.
  4. Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps).
  5. Tighten bottom hinge screws.
  6. Tighten top hinge screws and replace hinge cover.

REVERSING THE DOOR
Location of the unit may make it desirable to mount the door on the opposite side of the cabinet.
The hinge hardware will be removed and reinstalled on the opposite side of the cabinet.
TO REVERSE THE DOORU-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator -
TO REVERSE THE DOOR Remove arrow clips:

  1. With a puddy knife or other flat tool, gently pry each arrow clip from hinge mounting holes.
  2. Set aside arrow clips to be reused on the opposite side.

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE DOOR
1 Remove grille:
Remove the grille (see GRILLE INSTALLATION section of this guide).

Remove top hinge and door:

  1. Hold door to keep it from falling.
  2. Remove top hinge from cabinet using a Torx T-25 screwdriver to remove three screws. Set aside and save for possible future use.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE DOOR 2
  3. Remove door by tilting forward and lifting door off bottom hinge. Retain shoulder washers; they will be reused.
  4. Insert arrow clips into holesU-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE DOOR 3

Remove bottom hinge:

  1. Remove bottom hinge from cabinet using a T-25 TORX screw driver to remove three screws.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE DOOR 4
  2. Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind one or both screws on either side.

Install bottom hinge:
Install two or three screws, depending on model. Replace nuts if used.U-LINE
UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE DOOR
5 Install top hinge and door:U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE
DOOR 6

  1. Remove pivot screw from hinge, flip hinge over, and install the pivot screw in the same hole from the opposite surface.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - TO REVERSE THE DOOR 7
  2. Lift the door onto the bottom hinge.
  3. Align edge of the hinge with the outer edge of the unit while inserting pivot screw into top of door.
  4. Tighten three screws and replace hinge cover.
  5. Replace hinge cover.

Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND ADJUSTMENT)

Maintenance

Free Standing Kit
The free standing kit is an optional accessory, used when unit is freestanding – not built into a cabinet.
Te free standing kit is an optional accessory (ULAFREESTANDS), used when unit is freestanding – not built into a cabinet. Available at u-line.com.
To install the kit:

  1. Remove grille (see GRILLE INSTALLATION section).U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Free Standing Kit
  2. Place shell accessory over front and back of cabinet base, aligning holes of shell accessory with the holes on the base. Insert sheet metal screw in back of base.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Free Standing Kit 1
  3. Align front hole with hole in shell accessory, hole in base, and hole in grille. Tighten screw. U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Free Standing Kit 2

Operating Instructions

First Use
Initial startup requires no adjustments. If the unit was turned off, press and hold for 5 seconds to turn unit on. See “Control Operation” section for more details.

NOTICE
Temperature displayed reflects actual temperature inside unit.
If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set point before loading.

Control Operation

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Control
Operation

CONTROL FUNCTION GUIDE

FUNCTION COMMAND NOTES
ON/OFF Press and hold down for 5 seconds Unit will turn On or OFF
Leave interior light on Press and release to leave interior light on for 3
hours; press again to deactivate After 3 hours, factory default is restored;

light will turn on when door is open
Adjust Temperature| Press or and release| When the display is flashing, press  or       to adjust the set point temperature. Note: temperature displayed is the actual temperature inside unit
Toggle between ºF / ºC| Hold __ and for 5 seconds| The display will change units
Enable Sabbath Mode| Press  and hold for 5 seconds and release| The oF / oC symbol will flash briefly after 5 seconds.
Interior light and display will go dark and remain so until user resets mode – unit continues to operate
Disable Sabbath Mode| Press  and release| Display and interior light return to normal operation
Showroom Mode| Hold and  for 5 seconds| Display will show  SH for 2 seconds. Interior light and display will function normally, but the compressor and fans will not energize.
Repeat command to return to normal operation. Display will show EH for 2 seconds.

DOOR ALERT NOTIFICATION
When the door is left open for more than 5 minutes:

  • will appear in display

Airflow and Product Loading
AIRFLOW External

  • Do not block the front grille – no additional clearance around sides, top or rear of unit is needed for ventilation
  • Do not install behind a closed door

Internal

  • When loading, leave space between internal fans, ventsand side walls to allow air to circulate freely

PRODUCT LOADING
Bottles and cans come in many shapes and sizes. Not all bottles and cans will fit on every shelf and wine rack.
Larger diameter champagne and Magnum bottles only fit on wine racks when noted on the product specifications.
When determining capacities U-Line uses typical 12 oz.
cans, 12 oz. bottles, 750 mL white wine and red wine bottles shown below.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - PRODUCT
LOADINGU-LINE
UORE124-SS01A 24 Inch Outdoor Refrigerator - PRODUCT LOADING
1 Interior Adjustments
INTERIOR SHELVES
Removing and Installing Interior Shelves

For models equipped with glass shelves having recessed shelf supports, remove the shelves as follows:

  1. Pull shelf out about 6″ (1), until back of shelf clears the “hump” on the right-hand side.
  2. Tilt up right-hand edge of shelf (2).
  3. Remove shelf from unit by pulling out (3).

Insert the shelves as follows:

  1. To move to a different position in the unit, insert shelf at an angle, approximately 15-20°, over the rib in the side of the unit where you want to place the shelf. Place the shelf into the unit at an angle to clear the door.
  2. Continue to slide the shelf into the unit at an angle until it clears the door.
    Lower the shelf and push it in completely. Ensure the raised edge strip is toward the rear of the unit.

NOTICE
Make sure the shelves are inserted fully into the unit.
The edge strip toward the rear prevents cans and bottles from freezing against the cold evaporator.

Cleaning

Stainless Models
Stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach.
Keep your stainless unit looking new by cleaning with a good quality all-in- one stainless steel cleaner and polish monthly. For best results use Claire® Stainless Steel Polish and Cleaner. Comparable products are acceptable.
Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning weekly.

Do not clean with steel wool pads.
Do not use stainless steel cleaners or polishes on any glass surfaces.
Clean any glass surfaces with a non-chlorine glas cleaner.
Do not use cleaners not specifically intended for stainless steel on stainless steel surfaces (this includes glass, tile and counter cleaners).

If any surface discoloring or rusting appears, clean it quickly with Bon-Ami® or Barkeepers Friend Cleanser and a nonabrasive cloth. Always clean with the grain. Always finish with Claire® Stainless Steel Polish and Cleaner or comparable product to prevent further problems.
Using abrasive pads such as Scotchbrite™ will cause the graining in the stainless steel to become blurred.
Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible.
Integrated Models
To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendation.

INTERIOR CLEANING
Disconnect power to the unit.
Clean the interior and all removed components using a mild nonabrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth.
Rinse the interior using a soft sponge and clean water.

Do not use any solvent-based or abrasive
cleaners. These types of cleaners may transfer taste to the interior products and damage or discolor the lining.
DEFROSTING
Under normal conditions this unit does not require manual defrosting. Minor frost on the rear wall or visible through the evaporator plate vents is normal and will melt during each off cycle.
If there is excessive build-up of 1/4″ (6 mm) or more, manually defrost the unit.
Ensure the door is closing and sealing properly.
High ambient temperature and excessive humidity can also produce frost.

CAUTION
DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining.

NOTICE
The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry.
To defrost:

  1. Disconnect power to the unit.
  2. Remove all products from the interior.
  3. Prop the door in an open position (2 in. [50 mm] minimum).
  4. Allow the frost to melt naturally.
  5. After the frost melts completely clean the interior and all removed components. (See INTERIOR CLEANING).
  6. When the interior is dry, reconnect power and turn unit on.

Cleaning Condenser
INTERVAL – EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary.
Depending on environmental conditions, more or less frequent cleaning may be necessary.

WARNING
Disconnect electric power to the unit before cleaning the condenser.
NOTICE
DO NOT use any type of cleaner on the condenser unit. Condenser may be cleaned using a vacuum, soft brush, or compressed air.

  1. Remove the grille. See GRILLE INSTALLATION).
  2. Clean the condenser coil using a soft brush or vacuum cleaner.
  3. Install the grille.

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Cleaning
Condenser Extended Non-Use
VACATION/HOLIDAY, PROLONGED SHUTDOWN
The following steps are recommended for periods of extended non-use:

  1. Remove all consumable content from the unit.
  2. Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service.
  3. If ice is on the evaporator, allow ice to thaw naturally.
  4. Clean and dry the interior of the unit. Ensure all water has been removed from the unit.
  5. The door must remain open to prevent formation of mold and mildew. Open door a minimum of 2″ (50 mm) to provide the necessary ventilation.

WINTERIZATION
If the unit will be exposed to temperatures of 40°F (5°C) or less, the steps above must be followed.
For questions regarding winterization, please call U-Line at 414.354.0300.
CAUTION
Damage caused by freezing temperatures is not covered by the warranty.

Service

Troubleshooting
BEFORE CALLING FOR SERVICE
If you think your U-Line product is malfunctioning, read theCONTROL OPERATION section to clearly understand the function of the control.
If the problem persists, read the NORMAL OPERATING SOUNDS and TROUBLESHOOTING GUIDE sections below to help you quickly identify common problems and possiblecauses and remedies. Most often, this will resolve the problem without the need to call for service.

IF SERVICE IS REQUIRED
If you do not understand a troubleshooting remedy, or your roduct needs service, contact U-Line Corporation directly at +1.414.354.0300.
When you call, you will need your product Model and Serial Numbers. This information appears on the Model and Serial number plate located on the upper right or rear wall of the interior of your product.

NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components. Despite this technology, your model may make sounds that are unfamiliar.
Normal operating sounds may be more noticeable because of the unit’s environment. Hard surfaces such as cabinets, wood, vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a brief description of the normal operating sounds they make. NOTE: Your product may not contain all the components listed.

  • Compressor: The compressor makes a hum or pulsing sound that may be heard when it operates.
  • Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid.
  • Condenser Fan: Air moving through a condenser may be heard.
  • Automatic Defrost Drain Pan: Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle.

TROUBLESHOOTING GUIDE
DANGER
ELECTROCUTION HAZARD. Never attempt to repair or perform maintenance on the unit before disconnecting the main electrical power.
Troubleshooting – What to check when problems occur:

Problem Possible Cause and Remedy
Interior Light Does Not Illuminate If the unit is cooling, it may be in

Sabbath mode.
Light Remains on When Door Is Closed.| Turn off light switch if equipped.
Adjust light actuator bracket on bottom of door.
Unit Develops Frost on Internal Surfaces.| Ensure the door is closing and sealing properly.
Unit Develops Condensation on External Surfaces.| The unit is exposed to excessive humidity. Moisture will dissipate as humidity levels decrease.
Product is Not Cold Enough| Air temperature does not indicate product temperature. See CHECKING PRODUCT TEMPERATURE below.
Adjust the temperature to a cooler set point.
Ensure unit is not located in excessive ambient temperatures or in direct sunlight.
Ensure the door is closing and sealing properly.
Ensure the interior light has not remained on too long.
Ensure nothing is blocking the front grille, found at the bottom of the unit. Ensure the condenser coil is clean and free of any dirt or lint build-up.

CHECKING PRODUCT TEMPERATURE

To check the actual product temperature in the unit:

  1. Partially fill a plastic (nonbreakable) bottle with water.
  2. Insert an accurate thermometer.
  3. Tighten the bottle cap securely.
  4. Place the bottle in the desired area for 24 hours.
  5. Avoid opening the unit during the testing period.
  6. After 24 hours, check the temperature of the water. If required, adjust the temperature control in a small
    increment (see CONTROL OPERATION).

Causes which affect the internal temperatures of the cabinet include:

  • Temperature setting.
  • Ambient temperature where installed.
  • Installation in direct sunlight or near a heat source.
  • The number of door openings and the time the door is open.
  • The time the internal light is illuminated. (This mainly affects product on the top rack or shelf.)
  • Obstruction of front grille or condenser.

Wire DiagramU-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - PRODUCT
TEMPERATURE Product Liability
Field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, the technician should call U-Line for further explanation.
While inspecting for defects or installation issues, photos should be taken to document any damages or issues found. During the assessment, if the service technician is able to find the source of the damage and it can be resolved by replacement of a part, the servicer is authorized to replace the part in question. The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the
part.
If the service technician determines the damage is the result of installation issues (water connection/drain, etc.), the consumer would be notified and the issues shall be resolved at the direction of the consumer.
If damage is evident and the service technician is unable to find the source, U-Line must be contacted at +1.414.354.0300 for further direction.
8900 N. 55th Street • Milwaukee, WI 53223
T: +1.414.354.0300 • F: +1.414.354.5696
Website: www.u-line.com
Right product. Right place.
Right temperature Since 1962.

Warranty Claims
The following information defines the parameters for filing a warranty claim:

  • Valid serial number needed
  • Valid model number needed
  • Claims must be submitted online at www.U‑LineService.com
  • 60 day submittal deadline from date of completed service
  • Only one repair or unit per warranty claim
  • Part order numbers will be required when submitting for warranty labor

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - PRODUCT TEMPERATURE
3

Units must be registered prior to warranty submittal.
Customers may register at www.U‑Line.com. A proof of purchase is required. We also accept the following information to update warranty:

  • New construction occupancy documents
  • Closing paperwork
  • Final billing – Remodel

Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.

PartsU-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator -
Parts

UORE124-SSO1A

1| ANTI-TIP BRACKET| 80-54244-00
2| BACK PANEL| 80-55497-00
3| COMPRESSOR ELECTRICALS ONLY| 80-54149-00
4| COMPRESSOR W/ELECTRICALS| 80-54150-00
5| CONDENSER ASSEMBLY| 80-54264-00
6| CONDENSER FAN W/SCREWS| 80-54014-00
7| DISPLAY ASSEMBLY W/MAIN BOARD| 80-55533-00
8| DOOR| 80-55421-00
9| DRAIN PAN| 80-54217-00
10| DRIER| 80-54055-00
11| EVAPORATOR ASSEMBLY| 80-55411-00
12| EVAPORATOR COVER| 80-55513-00
13| EVAPORATOR FAN| 80-54321-00
14| EVAPORATOR FAN COVER| 80-54320-00
15| GASKET, DOOR| 80-55498-00
16| GLASS SHELF – BOTTOM| 80-54274-00
17| GLASS SHELF – TOP| 80-54277-01
18| GRILLE| 80-55597-00
19| HINGE ASSEMBLY| 80-55418-00
20| HINGE COVER| 80-55499-00
21| LED LIGHT STRIP AND COVER| 80-54000-00
22| LEG LEVELERS (4)| 80-54019-00
23| MAGNET ASSEMBLY| 80-54250-00
24| POWER CORD
| 80-55401-00
25| REED SWITCH (LOCATED BEHIND DISPLAY)| 80-54284-00
26| THERMISTOR| 80-54006-00
27| THERMISTOR COVER| 80-54237-00
28| WIRE HARNESS
| 80-55402-00

*Not Shown

Ordering Replacement Parts
Parts may be ordered online at www.U-Line.com
See our contact information below:
www.U-LineService.com (with service login)
Phone Number: +1.414.354.0300
NOTICE
Use only genuine U-Line replacement parts. The use of non-U-Line parts can reduce speed of ice production, cause water to overflow from ice maker mold, damage the unit, and void the warranty.
Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
If U-Line requires the return of original parts, we will inform you when the parts order is taken. This requirement will be noted on your packing list. A prepaid shipping label will be emailed to you. Please enclose a copy of the parts packing list and be sure the
model and serial numbers are legible on the paperwork.
Tag the part with the reported defect.
Customers and non-authorized servicers may order nonwarranty parts at www.u-line.com.
Authorized servicers with a servicer login may order non-warranty parts at www.u-lineservice.com.

R-600A Specifications
For R-600a refrigerant service tips and more videos, go to: www.u-line.com/videos.
WARNING
Flammability warnings for a pure-iso-butane refrigerant.U-LINE UORE124-SS01A
24 Inch Outdoor Refrigerator - Flammability

Gloves and Eye Protection must be used.U-LINE UORE124-SS01A 24 Inch Outdoor
Refrigerator - Eye Protection

R-600a is considered non-toxic, but is flammable when mixed with air.
Keep a dry powder type fire extinguisher in the work area. R-600a is heavier than air, do not allow any leakage/migration to low areas such as basements and stairs.
Never use a torch on a fully charged refrigeration system.
Never substitute U-Line OEM replacement parts or methods of construction.
R-600a must be stored and transported in approved containers.

WARNING
Only skilled and well trained service technicians permitted to service R-600a equipped products. All tools and equipment must be approved for use with R-600a refrigerant.
Local, state and federal laws, standards must be observed along with proper certification and licensing.
Ventilation is required during servicing.
No conversions to R-600a from any other refrigerants. OEM R-600a equipped unit only.
Service area must be free of ignition sources.
No smoking is allowed in the service area.
All replacement electrical components must be OEM and installed properly (sealed and covered).
If the evaporator is cold prior to service, it must be thawed prior to service.
When using a vacuum pump, start pump before opening refrigeration system.
Vacuum pump and recovery equipment should be at least 10 feet from the work area.
It is recommended that a simple LPG gas detector is on site during service.
Ensure that all R-600a is removed from the system prior to brazing any part of the sealed  system.
Only a clean, dry leak free system should be charged with R-600a.

R-600A SPECIFICATIONS/LABELING
R-600a equipped products are labeled (both the unit and the compressor).
R-600a is colorless and odorless.
R-600a is considered non-toxic, but is flammable when mixed with air.
Do not remove or alter any R-600a labeling on the product.
Use only a refrigerant grade R-600a from a properly labeled container.
RECOVERING/RECLAIMING R-600A
(R-600a has been exempted from recovery/reclaiming requirements by the US EPA)
Recovery/Reclaiming equipment must be approved for use with R-600a.
Ensure the evaporator is at room temperature prior to recovery/reclaiming R-600a.
Use a common piercing pliers or piercing valve to remove R-600a from the compressor process tube. (Note: Piercing devices must not be left on the system and must be replaced with a Schrader type valve.)

Evacuate/reclaim via the piecing pliers to ensure the system is empty of R-600a before any system work is performed.U-LINE UORE124-SS01A 24 Inch
Outdoor Refrigerator - piecing pliers

The recovery cylinder must be evacuated (no air inside) prior to accepting R-600a.
The recovery cylinder must not be filled more than 45% safe fill level and refrigerants must not be mixed.
The recovery cylinder must be clearly marked with R600a and Flammable Warning labels.
Ensure proper ventilation during recovery/reclaiming of R600a.
Start vacuum pump/recovery pump prior to piercing the compressor process tube.
Follow recovery/reclaim OEM instructions for the specific equipment used.
SYSTEM REPAIR
Ensure no residual R-600a refrigerant is left within the system prior to repair (simple venting is not sufficient).
Evacuate and charge with dry nitrogen for leak checks.
Repair leaks or replace system parts as required.
When re-brazing, the system must be purged with dry nitrogen and at least one access point open to the atmosphere.
When re-brazing, proper ventilation is required along with constant monitoring for the presence of R600a refrigerant.
The filter dryer must be replaced any time the sealed system is serviced.
No system should be open to the atmosphere for longer than 15 minutes to avoid moisture migration into the system components.

LEAK DETECTION
After removal of the R-600a, the unit can be charged with dry nitrogen or helium.
Electronic leak detection or soap solution can be used to check for nitrogen/helium leaks.

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - LEAK
DETECTIONNever use a halide torch or lighted match to check the system for leaks at any time.
The high side of the refrigeration system (compressor discharge to outlet of drier) must be leak tested with the compressor running.

The low side of the refrigeration system (evaporator, compressor and suction line) must be leak tested with the compressor off (equalized pressure).
RECHARGING
No air is ever to be allowed inside the refrigeration system (R-600a refrigerant or dry nitrogen only).
Never use a torch on a fully charged refrigeration system.
Install a Schrader Type access port on the compressor process stub.U-LINE
UORE124-SS01A 24 Inch Outdoor Refrigerator - RECHARGINGEvacuate the system to 100 microns prior to charging.
Weigh in the R-600a charge using a refrigerant scale. (run compressor an extra two minutes to clear the charging hoses).
Seal the Schrader Type access port, a proper cap and seal must be used to close the system.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator -
RECHARGING 1 SUMMARY
Safely handling R-600a requires proper procedures and training.
R-600a approved service tools must be used.
R-600a labeling must not be removed or altered.

System Diagnosis Guide
REGRIGERATION SYSTEM DIAGNOSIS GUIDE

System Condition| Suction Pressure| Suction Line| Compressor Discharge| Condenser| Capillary Tube| Evaporator| Wattage
---|---|---|---|---|---|---|---
Normal| Normal| Slightly below room temperature| Very hot| Very hot| Warm| Cold| Normal
Overcharge| Higher than normal| Very cold may frost heavily| Slightly warm to hot| Hot to warm| Cool| Cold| Higher than normal
Undercharge| Lower than normal| Warm- near room temperature| Hot| Warm| Warm| Extremely cold near inlet – Outlet below room temperature| Lower than normal
Partial Restriction| Somewhat lower than normal vacuum| Warm- near room temperature| Very hot| Top passes warm – Lower passes cool (near room temperature) due to liquid| Room temperature (cool) or colder| Extremely cold near inlet – Outlet below room temperature backing up| Lower than normal
Complete Restriction| In deep vacuum| Room temperature (cool)| Room temperature (cool)| Room temperature (cool)| Room temperature (cool)| No refrigeration| Lower than normal
No Gas| 0 PSIG to 25”| Room temperature (cool)| Cool to hot| Room temperature (cool)| Room temperature (cool)| No refrigeration| Lower than normal

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - System Diagnosis
Guide Compressor Specifications
DANGER!
Electrocution can cause death or serious injury.
Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing this unit.
Disconnect the power source.
Do not stand in standing water when working around electrical appliances.
Make sure the surfaces you touch are not hot or frozen.
Do not touch a bare circuit board unless you are wearing an anti-static wrist strap that is grounded to an electrical ground or grounded water pipe.
Handle circuit boards carefully and avoid touching components.

To measure the start winding resistance, measure across the C and S pins.
To measure the run winding resistance, measure across the C and R pins.
Also check S to R and you should get the sum of the run and start windings.
To ensure the windings are not shorted, check the S and R to ground.U-LINE
UORE124-SS01A 24 Inch Outdoor Refrigerator - Compressor
Specifications

| EMX20CLC
---|---
Refrigerant| R600a
Voltage| 115 – 127 VAC
Frequency| 60 Hz
Run Cap| 12μF/165 VAC
Start Winding| 6.7 Ohm at 77°F
Run Winding| 12.6 Ohm at 77°F
LRA| 3.7 A
FLA| 0.5 A
Starting Device| 8EA14C
Overload| 4TM142RFBYY-53

  • All resistance readings are ±10%

Troubleshooting – Extended
CAUTION
Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected from the unit.
SPECIFIC ERRORS AND ISSUES
The advanced diagnostic capabilities of the electronic controls utilized on the 1, 3, and 5 Class units allow for easy and thorough troubleshooting.
Navigation of the control is the key and is explained in the CONTROL OPERATION section of the manual, along with control button layout, control function descriptions, a service mode menu and service menu selection explanations.
Verification of temperature and thermistor performance can be identified by directly viewing thermistor readings in the service mode.
Included in this section are some diagnostic tips; if additional help is required, please contact the U-Line Corp, “Customer Care Facility” at +1.414.354.0300 for assistance.

NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components. Despite this technology, your model may make sounds that are unfamiliar.
Normal operating sounds may be more noticeable because of the unit’s environment. Hard surfaces such as cabinets, wood, vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a brief description of the normal sounds they make.
NOTE:
Your product may not contain all the components listed.

  • Compressor: The compressor makes a hum or pulsing sound that may be heard when it operates.
  • Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid.
  • Condenser Fan: Air moving through a condenser may be heard.
  • Automatic Defrost Drain Pan: Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle.

Solenoid Valves: An occasional clicking sound may be heard as solenoid valves are operated.

TROUBLESHOOTING GUIDE

Concern Potential Causes Action
Not Cooling Compressor overheating Verify proper air flow through condenser.

Is condenser clean?
Confirm condenser fan operation.
Compressor not operating| Test overload and relay, replace as needed.
Compressor operating – no cooling| Refer to System Diagnosis Guide.
Frozen Product| Control set too cold| Adjust Set Point Temp accordingly.
Thermistor failure| Check Error Log in Service Mode, OHM thermistor.
Frost Buildup Inside Unit| Door Ajar or Restricted from Closing| Check door clearance to adjoining cabinetry. Check distribution of product in unit.
Thermistor failure| OHM thermistor
Display Not Working| Display unplugged| Verify that both ends of the display wiring are firmly connected.
Display wiring broken or damaged| Perform continuity test of wiring and replace as needed.
Interior Lights Not Working| Door switch misaligned or defective| Check the function of reed switch and door magnet adjustment.
Noisy| Refrigeration tubing touching cabinet| Carefully reposition tubing.
Fan blade obstruction (wiring, foam insulation, packaging material)| Remove obstruction.

MAIN CONTROL
The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose the board for any suspected failures before attempting to remove the board for replacement or service. Follow the guidelines below to fully test and diagnose the main control.
Power Fault
If the unit does not (or seems to not) power on, follow the flow chart below to help diagnose the issue. Before beginning it is important to first verify the unit is not simply set to sabbath mode.

U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Power
Fault CAUTION
Precautions must be taken while working with live electrical equipment. Be sure to follow proper safety procedures while performing tests on live systems.
PLUNGER SWITCH
A plunger switch is used to monitor door state. When the door is closed it comes into contact with the plunger which closes a circuit which turns the light and display off. When the door is open the plunger moves outward and opens the circuit. If the door is left open for longer than 5 minutes the switch will trigger an error code and set an audible warning.U-LINE
UORE124-SS01A 24 Inch Outdoor Refrigerator - PLUNGER
SWITCH Control Operation-Service
UI BUTTON LAYOUTU-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator -
Control Operation

  1. Up Button
    -Increases temperature
    -Navigates through service menu
    -LED activated with button activation
  2. Down Button
    -Decreases temperature
    -Navigates through service menu
    -LED activated with button activation
  3. Light Button
    -Activates light for 3 hours on select models
    -Used to select items in service menu
    -LED activated with button activation

CONTROL FUNCTION GUIDE

FUNCTION COMMAND NOTES
Defrost Duration Enter menu by pressing for more than 5 seconds.
Use or  to increase/reduce defrost duration. Press  to select. Display shows

“df” (defrosting). This controls how long the unit defrosts.
Defrost Period| Press  once again. Use  or to increase/reduce defrost period.
Press  again.| Display shows the interval in which the unit defrosts in hours.
Set Offset Temperature| Use   or to increase/reduce tempera- ture.| Each adjustment for this setting is 1 degree: Positive = colder
Negative = warmer
Exit Menu| Press  and release|

Thermistor
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatures.
If a faulty thermistor is suspected, it may be tested using an accurate ohmmeter.
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatures. If a faulty thermistor is suspected it may be tested using an accurate ohmmeter.
Thermistor connections must be kept clean. A thermistor connection that has become corroded can cause resistance values from the thermistor to change as they pass through a dirty connection to the board.
Both thermistors in the unit are identical. If a thermistor is suspected of being defective, the resistance can be verified. Place the thermistor in an ice water bath, the resistance should read 16.1k Ohms +/-5% on your meter.
It is for that reason that we apply dielectric grease to all of our thermistor connections. Dielectric grease will help to keep thermistor connections clean and dry.
Thermistor connections must be kept clean. A thermistor connection that has become corroded can cause resistance values from the thermistor to change as they pass through a dirty connection to the board.
If you change a thermistor in the unit, please re-apply dielectric grease to the connection. If you encounter a dirty thermistor connection, you should replace the thermistor and the thermistor harness.
It is for that reason that we apply dielectric grease to all of our thermistor connections. Dielectric grease will help to keep thermistor connections clean and dry.
This unit has one thermistor located along the right hand sidewall of the ice bin. It is used to maintain the ice level in the bin.
If you change a thermistor in the unit please re-apply dielectric grease to the connection. If you encounter a dirty thermistor connection, you should replace the thermistor and the thermistor harness.
Thermistor error information can be found in the Control Operations – Service section.
This unit has one thermistor.
Thermistor one (Zone):
Located along the right hand side wall. It is used to maintain the operating temperature within that zone.
THERMISTOR FAILURE
Zone Thermistor
If the zone thermistor in the unit fails, the unit will continue to cool in a backup mode (Self Preservation Mode) to preserve the integrity of the contents. The unit will otherwise operate normally.

Thermistor Resistance Data

Temp (F) Temp (C) **Nominal Resistance (OHMS)***
-40 -40 169157
-31 -35 121795
-22 -30 88766
-13 -25 65333
-4 -20 48614
5 -15 36503
14 -10 27681
23 -5 21166
32 0 16330
41 5 12696
50 10 9951
59 15 7855
68 20 6246
77 25 5000
86 30 4029
95 35 3266
104 40 2665
113 45 2186
122 50 1803
131 55 1495
140 60 1247
149 65 1044
158 70 879
167 75 743
176 80 631
  • (+/- 5%)

Defrost
Outdoor units defrost every 12 hours of compressor runtime for 45 minutes. If you have verified that the unit does not have an ambient air leak, utilize the Control Operation – Service section and adjust unit to defrost every 9 hours for 60 minutes

Remove Fan and Cover
CONVECTION COOLING
This unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, cools product faster and increases energy efficiency.
Evaporator Fan
The evaporator fan is responsible for circulating warm air from the refrigeration zone, past the evaporator and back into the refrigerated zone.
The evaporator fan is factory set to have a 1 minute delay at the beginning of a cooling cycle. This delay gives the evaporator time to cool properly before warm air is passed over it. The fan will continue to run for an additional 2 minutes at the end of a cooling cycle. Fan delay times can be modified through the service menu.
Evaporator fan operation is also determined by door switch state. If the door switch circuit opens, the fan will stop.
When the door switch circuit is closed the fan will either continue running with the cooling cycle, or if not currently cooling, the fan will run for 1 minute to circulate air and clear any condensation that may have appeared on glass doors and shelves.
Note: If the unit is set to sabbath mode, the evaporator fan will no longer respond to the state of the door switch.
In order to operate efficiently, the evaporator fan blade and vents should be unobstructed and free of any dust buildup.

Evaporator Fan Replacement
Should the evaporator fan need to be replaced follow the steps below.

  1. Remove any product from the unit.

  2. Remove unit from cabinetry to access rear.

  3. Disconnect power to the unit.

  4. Remove back panel from unit.

  5. Disconnect fan electrical connection at rear of unit.

  6. Remove insulating foam from refrigerant line passthrough hole as needed to gain clearance for fan plug.

  7. Remove internal shelving.

  8. Remove rear shelf clips, fronts can remain.

  9. Remove thermistor cover.

  10. Remove two evaporator cover screws from top of evaporator plate.

  11. Grasp evaporator cover, pull forward and up as bottom of cover is installed behind the front edge of the drain trough.

  12. While pulling the evaporator cover clear of the unit, it may be necessary to use your free hand to manipulate the fan plug end through the pass-through hole.

  13. Remove the 4 screws mounting the fan shroud to the evaporator plate.U-LINE UORE124-SS01A 24 Inch Outdoor Refrigerator - Evaporator Fan Replacement 1

  14. Remove and replace fan. Take special care to properly route fan wire.
    NOTICE
    Fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting location.

  15. Installation is the reverse of removal.

  16. Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough.

  17. Use sealant gum to seal any openings at rear of unit before replacing rear cover.

  18. Reinstall unit taking care to level, space and secure as found.

U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during normal business hours.
Two Year Limited Warranty (5 Class Product)
For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material  cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during normal business hours.
Available Second & Third Year Limited Warranty
In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60  days from the date of purchase at u-line.com and provide proof of purchase. Nugget Ice Machine proof of purchase must include the purchase of an in-line water filter and filter head to qualify for this additional limited warranty.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or  improper use, maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and maintained in accordance with your product’s User Guide.
The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal rights, and you may also have other rights which vary from state to state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

  • The warranties only apply to the original purchaser and are non-transferable.
  • The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.
  • The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
  • U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and third year limited warranties.
  • Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
  • The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.
  • In-home instruction on how to use your product is not covered by these warranties.
  • Food, beverage, and medicine loss are not covered by these warranties.
  • If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.
  • Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only and no coverage is provided for cosmetic defects.
  • Signal issues related to Wi-Fi connectivity are not covered by these warranties.

For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 8900 N. 55 th
Street, Milwaukee, WI 53223 • u-line.com • onlineservice@u-line.com • +1.414.354.0300

U-LINE logo GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday – Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Email: sales@u-line.com
u-line.com 
SERVICE & PARTS ASSISTANCE
Monday – Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US

Designed, engineered and assembled in WI, USA
Copyright U-Line Corporation. All Rights Reserved.
Publication Number 30379
11/2022 Rev. P

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals