SALUS SAUNAS 71D x 81H Vista Front Glass Barrel Sauna Owner’s Manual
- June 16, 2024
- SALUS SAUNAS
Table of Contents
VISTA FRONT GLASS 4-PERSON BARREL SAUNA
OWNER’S MANUAL
WARNING! Do not place anything combustible close to heater, above the heater, and on both sides of the heater. This includes but not limited to towels, lights, robe hooks, accessories, etc. Nothing should be on the same wall as your heater that is combustible.
Front & Back Walls
VISTA FRONT GLASS Barrel Sauna 71D” x 81H”
Details list.
63″x 8⅞” x 3¾” (x2)
51³/₁₆” • 63″ • 78セ” x 1⅝” (x2)
59¹/₁₆” • 70⅞” • 86⅝” x 4²³/₃₂” x 1⅝” (x1)
59¹/₁₆” • 70⅞” • 86⅝” x 1⅝”
59¹/₁₆” • 70⅞” • 86⅝” x 1¾” x 1⅝” (x1)
59¹/₁₆” • 70⅞” • 86⅝” x 1″ x 1⅝” (x2)
59¹/₁₆” • 70⅞” • 86⅝” x 1³/₁₆ ” x 1⅝” (x1)
59¹/₁₆” • 70⅞” • 86⅝” x 3/4″ x 1⅝” (x1)
59¹/₁₆” • 70⅞” • 86⅝” x 3/8″ x 1⅝ ” (x1)
51³/₁₆” • 63″ • 78¾” x 20¹¹/₁₆” x 3¹⁵/₁₆” (x2)
18½” x 1¾” x 1¾” (x2)
5⅞” x 1¾” x 1¾ “ (x2)
50″ • 61¹³/₁₆” • 77⁹/₁₆” x 15³/₁₆” x 3⁹/₁₆” (x2)
L=~256″ (x2)
(x4)
(x1)
(x3)
x2 drain set
3¹⁵/₃₂” x 1⅝” 1⅛” (x2)
25¹⁹/₃₂ x 3¹⁵/₃₂” x 1⅛” (x2)
27⁹/₁₆x 1⅝” x 1⅛” (x2)
32¹¹/₁₆ x 3¹⁵/₃₂” x 1⅛” (x1)
(x1)
59¹/₁₆” • 70⅞” • 86⅝” x 2″ x 2″ (x2)
(x38/50/62)
(x5/7/8)
L=~17³/₁₆ (x16)
Bit PH2
Torx bits
T10 T15
T20 T25
~2lbs.
⅛” x 1¼ (x15)
⅛” x 1½” (x90)
³/₁₆” x 2″ (x45)
⁵/₃₂” x 2¼” (x150)
³/₁₆” x 3½” (x50)
(x4)
(x4)
L=~9⅞” (x2)
Tools needed
Measuring tape
Marker pen
Circular saw
Water level
Hammer
Extra hands
Ratchet strap
Silicone gun
(Only glass-wall models)
Drill
Cresent wrench
Utility knife
Rubber mallet
Front glass wall installation
Thickness 1 ¹/₁₆”
x1
x1
x3
x3
x2
x2
Thickness ⅝”
x2
x2
x2
x2
x2
76″ x 3¾” x 1⅛” x1
Silicone
18½” x 1¾” x 1¾” x2
5⅞” x 1¾” x 1¾” x2
Baseframe 1 ¹/₁₆”
-
Use scrap piece of wood to protect plywood
-
Apply waterproof silicone to the groove
- Mount carefully glasses.
Coverframe ¹⁹/₃₂”
- Use scrap piece of wood to protect plywood
- Apply waterproof silicone to the groove
-
CAUTION!
Do not hit the glass with the screw. -
Install front glass-wall same way as instructed in main manual.
-
DET U
Fix it diagonally to make wall more rigid during the installation. -
Proceed with main manual until benches installation!
- WARNING: Do not let screws touch glass!
- Drill holes ⅛” before screws.
- Under the benches both sides.
- Pre-drill holes ⅛”
- Fasten screws under the benches on both sides
- CAUTION! Do not hit the glass with the screw.
Wooden back wall assembly
Details
- Pre-drill holes 5/32″ before screws.
- Brackets inside.
- Install front glass-wall same way as instructed in main manual.
VISTA FRONT GLASS Barrel Sauna 71D” x 81H”
- Diagonal measurements should be equal
Center stave 2 on cradle 1
mm=mm
- Position cradles inside grooves of stave 2
- Drill 4 holes Ø1/2″ through DET 2 outside
- Fix temporarily to support walls.
- Use waterlevel
- Brackets inside
- Check walls installation manual on extra pages!
- Sauna wall configuration depends on Your model!
- IMPORTANT! Be sure to leave a 1/4”gap when tightening screws to leave room for adjustment when the outer bands (B) are installed.
-
Remove temporary bracing
-
Important!
Leave space -
IMPORTANT! Be sure to leave a 1/4” gap when tightening screws to leave room for adjustment when the outer bands (B) are installed.
-
Strap
-
Use strap to support boards during installation
- See the next page.
- Join two boards together (as shown in diagram II) that will bridge the width of the “A” gap. It is recommended that the combined boards are approximately 1/4″ wider than the gap.
- If needed, trim the flat edge of the board to create the desired width.
- Fasten the two halves using screws
- Raise slightly before installing the combined board
- Remove strap
- Place the bands around the barrel on the outer side of the cradle.
E7G Barrel Sauna 71D” x 81H”
- Remove all temporary braces
- Upper vent
- Lower vent
- Pre-drill holes Ø5/32″ before screws.
- 72″ and 88″ Saunas with front-glass wall have 4 pc. of DET 10a.
- NB! If Your sauna equipped with front-glass wall, see front-glass wall installation manual for proper benches installation.
VISTA FRONT GLASS Barrel Sauna 71D” x 81H”
- Pre-drill holes 1/8″
- Use level for installation of benches
- 72″ & 88″ Saunas with front-glass walls have four pieces of 10c.
- Under the benches
- If needed – To accommodate the size of your heater, trim 15A on the end that meets the back wall, before adding part H
- Mount sauna heater before installing safety rail, per manufacturer’s recommended safety clearance
- Use waterlevel!
- X = Front wall thickness Wooden front wall 1⅛” Glass front wall 1⅝”
-
Fasten door from inside.
-
Ensure door frame is pressed tightly against the wall and fasten from inside
See the installation manual inside the shingles package
-
Overlap shingles on top
-
Cut off
-
Cut and use other end.
-
Check also roof shingles installation manual inside package.
-
Cut DET N into three equal segments
- Remove
- DET A
Documents / Resources
|
SALUS SAUNAS 71D x 81H Vista Front Glass Barrel
Sauna
[pdf] Owner's Manual
71D x 81H Vista Front Glass Barrel Sauna, 71D x 81H, Vista Front Glass Barrel
Sauna, Front Glass Barrel Sauna, Glass Barrel Sauna, Barrel Sauna, Sauna
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>