INTRODUCTION
IVP 1000 Pet SF
Wireless passive infrared motion sensor
Congratulations, you have just purchased a product with Intel bras quality and
safety.
The IVP 1000 Pet SF motion sensor features passive infrared ray detection
technology, with advanced signal analysis technology that prevents accidental
triggering.
Care and safety
» Follow all the instructions in the manual for the correct assembly and
installation of the product;
» LGPD – Data processing by Intelbras: Intelbras does not access,
transfer, capture or process any type of personal data from this product;
» Fix the sensor on stable surfaces, where there are no vibrations;
» This sensor is intended for indoor environments;
» Do not use the sensor in areas with sudden temperature changes such as near air conditioners and heaters, fans, refrigerators and ovens. Do not expose the sensor directly or to sunlight reflections;
» Do not touch the surface of the infrared sensor (PIR), if necessary, use a
cleaning cloth;
» Do not place objects in front of the sensor. To ensure the detection area,
avoid curtains, screens, screens, or any object that may interfere with its
coverage area;
» Wireless communication technology, when exposed to environments with high
power radiation, may suffer interference and have its performance impaired.
Example: locations close to TV towers, AM/FM radio stations, amateur
radio stations, routers, etc;
» The recommended installation height is between 2.0 and 2.40 meters. If the
sensor is installed at a different height than the specified one, its
detection and Pet function may be impaired in such a way as to nullify the Pet
immunity;
» The sensor must be installed where a possible intruder can be easily
detected, that is, where it moves across the detection beams (see figure
below)
» The Pet function is intended for flat animals weighing up to 20 kg. If the animal is on top of a bench, for example, the Pet function can be canceled.
Scan (top view)
Detection range (side view)
Summary
Operating voltage | 3 Vdc |
---|---|
Battery | LITHIUM CR123A |
Operating current | 14 mA |
Consumption at rest | 4 uA |
Detection angle | 90° |
Detection range | 12 meters |
Detection method | RIP |
Immunity to crawling animals | Up to 20 kg |
Ssensitivity adjustment | 3 levels (1P-2P-3P) |
Startup time | Up to 60 seconds |
Operating Temperature | -10°C to 50°C |
Transmission frequency | 433.92 MHz |
Transmission distance | Up to 100m without barriers |
Modulation | OK |
Installation height range | 2.0 to 2.4 meters |
Recommended installation height | 2.1 meters |
Dimensions (W × H × D) | 50 × 75 × 42mm |
Weight | 0,047 Kg |
Characteristics
» Microcontrolled signal processing;
» Automatic temperature compensation to reduce false alarms;
» Immunity to white light up to 10,000 lux;
» High RFI/EMI immunity;
» Dual-element passive infrared;
» Adjustable infrared (PIR) sensitivity;
» Immunity to crawling animals weighing less than 20 kg;
» Power: LITHIUM battery 3 Vdc – CR123A;
» Battery level sensor.
Product
- Front Cover
- Fresnel lens
- PROG button
- Sensitivity selector switch
- LED trigger
- PIR sensor
- Battery connector
- Antenna
- Basis
- Screw seal
Sensor opening
To access the IVP 1000 PET SF sensor board to change the battery or
configuration, press the base lock, located on the bottom using a screwdriver
or similar tool.
**See image below:
**
Attention!
Press in that direction (straight). Avoid making twisting or levering
movements with the key that could damage the product cabinet.
Sensor stabilization
After inserting the battery, the sensor goes into stabilization mode and the red LED flashes for a few seconds. When stabilization is complete, the red LED will stop flashing.
IVP 1000 Pet SF sensor registration
To register the sensor in the control panel, check the procedure in the manual
of the control panel used and trigger a trigger by moving in front of the
sensor or press the PROG button located on the sensor board.
Note: do not register the sensor in the control unit during the
stabilization time.
Installation
After identifying the best installation location, follow the recommendations:
» It must be installed at a height of 2.0 m to 2.4 m and positioned so that
the intruder makes transverse movements to the sensor’s detection radius.
» It is not recommended that the sensor be installed at an angle or using an
articulator, as its detection range and Pet function may be impaired in such a
way as to cancel the function.
» Make sure the sensor is securely fixed and not subject to jitter in order to
avoid unwanted triggers.
-
Remove the front cover by pressing the base latch, as shown in item 4. Sensor opening.
-
For direct-to-wall or corner-wall installation, remove the plate and break the indicated seals for the screw holes in the base.
-
After fixing the base, fit the front cover to the top of the base and press the bottom of the front cover so that it fits the base.
Test
Once installed and running, walk across the area to be protected simulating a possible intrusion into the environment. Check if the sensor is able to detect your movements during the course, through the Red LED (triggering). Adjust the sensitivity if necessary or reposition the sensor. Be sure to take all precautions and follow installation recommendations to get the best operating performance from your product.
Note: if the control panel used is Intelbras, put it in test mode, this way it will not be necessary to observe the LED, as the control panel will indicate the functioning of the sensor through siren beeps. For more information, consult the central manual on the website: www.intelbras.com.br.
Sensor configuration
After the sensor is properly installed, perform the adjustments according to the information below:
IVP 1000 Pet SF sensor sensitivity adjustment
The selector switch (CH1) is used to control the detection sensitivity where it is possible to adjust the 3 detection levels.
» 1P: maximum sensitivity for motion detection;
» 2P: medium sensitivity (factory default);
» 3P: minimal sensitivity for greater robustness against accidental
triggering.
IVP 1000 Pet SF sensor operation mode
After being energized, the sensor will operate during the test period for 15 minutes so that the installer can make all adjustments to the sensor’s positioning. During this period, at any movement detection, the LED lights up and a trigger is generated. Then the sensor will operate in economy mode.
» Economy Mode: when detecting movement, it turns on the LED, triggers
and goes into hibernation, remaining for a period that can last from 30
seconds (environment with little movement) to 2 minutes (environment with a
lot of movement). During this sleep period the LED is not activated and no new
triggers are generated, as a notification has just been sent to the control
panel. After the hibernation period, the sensor monitors the environment again
until a new movement is detected.
This ability to learn from the movement of the environment means that in
places with a lot of movement, periodic and non-continuous shots are
generated, in turn, saving battery life.
Low battery sensor
The IVP 1000 Pet SF sensor controls the battery level and if it is critical it
sends the information to the control panel during triggering. In addition, the
sensor also signals through the LED, after each activation of the sensor the
LED lights up (as usual) and then flashes indicating low battery.
Use only quality batteries with the correct sizing for the device, and with
typical use of the device, the expected battery life is 1 to 2 years, which
may be influenced by the number of activations, weather conditions and mode of
settings. The battery model must be CR123A 3V, using one (1) battery per
sensor.
Battery
Use only quality batteries, with the correct size for the device. The battery
model must be CR123A, using one (1) battery per sensor.
We recommend replacing batteries with the same brand and industrial model as
purchased from factory products.
This product has an internal battery. After their useful life, the batteries must be delivered to an authorized Intelbras technical assistance department or directly disposed of in an environmentally appropriate manner, avoiding environmental and health impacts. If you prefer, the battery, as well as other unused Intelbras brand electronics, can be discarded at any Green Eletron collection point (electronic waste manager with which we are associated). If you have any questions about the reverse logistics process, please contact us by telephone (48) 2106-0006 or 0800 704 2767 (Monday to Friday from 8am to 8pm and Saturdays from 8am to 6pm) or via email -mail support@intelbras.com.br.
Battery replacement
To replace the product’s battery:
» Remove the dead battery;
» Press the PROG button or wait a few seconds for the circuit to completely
discharge;
» Connect new battery.
Homologation
This equipment is not entitled to protection against harmful interference and may not cause interference in properly authorized systems. This is a product approved by Anatel, the approval number can be found on the product label, for queries go to the website: sistemas.anatel.gov.br/sch.
Warranty term
It is established that this warranty is granted upon the following conditions:
Client’s name:
Client’s signature:
Invoice number:
Date of purchase:
Model:
Retailer:
Serial number:
- All the parts, pieces and components of the product are guaranteed against possible manufacturing defects, which may arise, for the term of 1 (one) year – this being 90 (ninety) days of legal warranty and 9 (nine) months of contractual warranty –, counting from the date of purchase of the product by the Consumer, as appears in the product purchase bill of sale, which is an integral part of this Term throughout the domestic territory. This contractual warranty includes the free exchange of parts, pieces and components which have a manufacturing defect, including the expenses with labor used in this repair. If there is no manufacturing defect, but defect(s) arising from misuse, the Consumer shall bear these expenses.
- The installation of the product shall be executed in accordance with the Product Manual and/or Installation Guide. If your product requires the installation and configuration by a qualified technician, seek a suitable specialized professional, the costs of these services not being included in the product amount.
- Having perceived the defect, the Consumer shall immediately contact the nearest Authorized Service which appears in the report offered by the manufacturer – they are the only ones authorized to examine and remedy the defect during the warranty term foreseen herein. If this is not respected, this warranty shall lose its validity, as it shall be characterized as product infringement.
- If the Consumer requests home service, it shall contact the nearest Authorized Service to inquire about the technical visit rate. If it is necessary to remove the product, the ensuing expenses, such as those of transportation and insurance of the taking and return of the product, shall be the Consumer’s responsibility.
- The warranty shall lose its validity totally in the occurrence of any of the following cases: a) if the defect is not one of manufacture, but is caused by the Consumer or by third parties foreign to the manufacturer; b) if the damage to the product arises from accidents, disasters, agents of nature (lightning, floods, landslides, etc.), humidity, voltage in the electrical network (excess voltage caused by accidents or excessive fluctuations in the network), installation/use in disagreement with the user’s manual or arising from natural wear of the parts, pieces and components; c) if the product has undergone effects of a chemical, electromagnetic, electrical or animal (insects, etc.) nature; d) if the serial number of the product has been falsified or erased; e) if the appliance has been infringed.
- This warranty does not cover loss of data; therefore, it is advisable that if it is the case of the product, the Consumer makes a backup regularly of the data which appears in the product.
- Intelbras is not responsible for the installation of this product, or for possible attempts at fraud and/or sabotage in its products. Maintain the updates of the software and applications used up-to-date, if it is the case, as well as the network protection required for defense against hackers. The equipment is guaranteed against defects in its usual conditions of use, it being important to bear in mind that, as it is electronic equipment, it Is not free of fraud and scams which may interfere with its correct functioning.
These being the conditions of this complementary Warranty Term, Intel bras S/A
reserves the right to alter the general, technical and esthetic features of
its products without prior notice.
All the images of this manual are illustrative.
Product benefiting from the Legislation of Informatics.
CUSTOMER SERVICES
Customer Support: +55 (48) 2106 0006
Forum: forum.intelbras.com.br
Support via chat:
chat.apps.intelbras.com.br
Support via e-mail:
suporte@intelbras.com.br
Customer Service / Where to buy? / Who installs it?:
0800 7042767
Produced by: Intelbras S/A
Rodovia BR 459, km 124, 1325
CNPJ 82.901.000/0016-03 – www.intelbras.com.br
| www.intelbras.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>