Schneider Electric LV429453
Wireless Indication
Auxiliary for MCCB – icon 15
Schneider Electric LV429453 Wireless Indication Auxiliary for MCCB –
icon 15
www.se.com
|
ComPacT NSXm / NSX100m / NSX160m
DOCA0185EN| NNZ4764707 ComPacT NSXm 3P/4P
NNZ4764807 ComPacT Vigi NSXm 3P/4P
PowerPacT B-Frame
DOCAOO094EN ‘ DOCAO095EN| GDE55878 PowerPacT B-Frame 2P/3P/4P
Refer to the gateway or Panel Server user guide to configure your system.|
Retain instruction sheet for future use.
Visit our website at www.se.com to download other
documents.
PLEASE NOTE
- Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
- No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
- All pertinent state, regional, and local safety regulations must be observed when installing and using this product.
DANGER/DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E, CSA Z462, NOM-029-STPS or local equivalent.
- This equipment must only be installed and serviced by qualified electrical personnel.
- Turn off all power supplying this equipment before working on or inside equipment.
- Always use a properly rated voltage sensing device to confirm power is off.
- Replace all devices, doors, and covers before turning on power to this equipment.
- Beware of potential hazards, and carefully inspect the work area for tools and objects that may have been left inside the equipment.
Failure to follow these instructions will result in death or serious injury.
WARNING
HAZARD OF UNINTENDED OPERATION
Do not use the wireless indication auxiliary for critical control or
protection applications.
Failure to follow these instructions can result in death, serious injury, or
equipment damage.
WARNING: Cancer and Reproductive Harm. www.P65Warnings.ca.gov.
Required for Installation
Description
2.1 Wirless Indication Auxiliary
A | Battery cover. |
---|---|
B | Actuator . |
C | Reset button. |
D | Status LED |
E | Label with a detachable adhesive part carrying a OR code and the RF-d |
address, useable during commissioning.
F| QR code to access device information, including RF-Id address.
2.2 Status Led
| Wireless indication auxiliary switched off or not in communication with
gateway or Panel Server.
---|---
| Wireless indication auxiliary in pairing mode, searching for a gateway or
Panel Server.
| Wireless indication auxiliary in identification mode.
| Wireless indication auxiliary in communication.
One green flash at each frame sent.
| Occasional loss of communication with the gateway or Panel Server.
| Wireless indication auxiliary in setting mode, with LED indication mode set
to] OFF.
| Wireless indication auxiliary in setting mode, with LED indication mode set
to] ON.
| Trip indication when wireless indication auxiliary is in SD slot and
configured in LED indication mode ON.
| Battery out of power.
Battery Installation
Before working on Equipment
- Tum off all power supplying this. equipment before working on or inside equipment.
- Use push-to-trip button to trip the device.
- Use a properly rated voltage sensing device to confirm power is off.
Installation
- Unscrew the screws of the front cover and remove it as directed in the instruction sheet of the device.
- Install the wireless indication auxiiary in the corresponding accessory siot
• OF: Indication of the open or closed status of the device
• SD: Indication of the tripped or non-tripped status of the device.
Setting LED Indication Mode
Set the LED indication mode of the wireless indication auxiliary to ON to
indicate a circuit breaker trip locally when the auxiliary is installed in
the SD slot
The LED indication mode is factory-set to OFF.
| 1. Press the Reset button.
The wireless indication auxiliary status LED blinks.
---|---
| 2. Press the Reset button three times in less than two seconds:
The auxiliary is in setting mode.
Status LED flashes:
• three times if LED indication mode is OFF
• six times if LED indication mode is ON.
| 3. Press the Reset button once to change the LED indication mode.
The flashing pattem of the status LED changes according to the new LED
indication mode.
| 4. To exit setting mode, press the Reset button for three seconds.
NOTE: if the Reset button is not pressed, the auxiliary exits setting
mode after two minutes.
Commissioning
- The wireless indication auxiliary can be commissioned with the device switched off.
- Before proceeding with pairing, ensure that the gateway or Panel Server has the latest available firmware version.
Refer to the user guide of the concerned gateway.
7.1 Pairing
-
Put the wireless indication auxiliary in pairing mode in one of the following ways:
• If the wireless indication auxiliary is not installed in the circuit breaker, press the Reset button or the actuator.
• If the wireless indication auxiliary is installed in the OF siot, open and close| the circuit breaker.
• If the wireless indication auxiliary is installed in the SD slot, open, close and action the push-to-trip button on the circuit breaker.
Result: The status LED blinks orange. The wireless indication auxiliary stays in pairing mode for three minutes. -
Pair the gateway or Panel Server with the wireless indication auxiliary by using EcoStruxure Power Commission software or the webpages of the lgateway or Panel Server.
Result: The status LED blinks green to indicate that the auxiliary is paired. -
Configure the wireless indication auxiliary by using EcoStruxure Power Commission software or the webpages lof the gateway or Panel Server.
7.2 Change of the Radio Frequency Channel
To change the radio frequency channel used by the gateway or Panel Server to
communicate:
-
Wake up the wireless indication auxiliary in one of the following ways:
• If the wireless indication auxiliary is not installed in the circuit breaker, press the Reset button or the actuator.
• If the wireless indication auxiliary is installed in the OF slot, open and close the circuit breaker.
• If the wireless indication auxiliary is installed in the SD slot, open, close and action the push-to-trip button on the circuit breaker.
Result: The wireless indication auxiliary wakes up, and is ready to be configured for three minutes. -
Change the radio frequency channel used by the gateway or Panel Server to communicate with the wireless indication auxiliary by using EcoStruxure Power ‘Commission software or the webpages of the gateway or Panel Server.
Result: The status LED blinks green to indicate that the auxiliary communicates with the gateway or Panel Server.
Reinstall Front Cover
DANGER/DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Put back the device front cover before energizing device to prevent access to
live terminals.
Failure to follow these instructions will result in death or serious injury.
NOTICE
HAZARD OF EQUIPMENT DAMAGE
- Be careful not to pinch electrical wires when installing front cover.
- Tighten all front cover screws to stated torque.
- Do not overtorque screws.
- Do not use power equipment to torque Screws.
Failure to follow these instructions can result in equipment damage.
- Put back front cover as directed in the instruction sheet of the device.
- Device is ready to be placed in service.
Unpairing
Press the Reset button for 3 s to unpair the wireless indication auxiiary.
Wirless Indcation Auxiliary Removal
Release tab to remove the wireless Indcation Auxiliary
Radio Frequency Compliance Statements
EU Declaration of Conformity
Hereby, Schneider Electric Industries SAS, declares that the wireless
indication auxiliary LV429453 is in compliance with the essential requirements
and other relevant provisions of RED Directive 2014/53/EU.
The EU PB21033002 declaration of conformity can be downloaded on
www.se.com/docs.
- IEEE 802.15.4 operating frequency: 2400-2483.5 MHz.
- Maximum radio-frequency power transmitted: <10 mW.
United Kingdom
UK Declaration of Conformity
Hereby, Schneider Electric Industries SAS, declares that the wireless
indication auxiliary \V429453 is in compliance with the essential requirements
and other relevant provisions of the Radio Equipment Regulations SI 2017 No.
1206.
The PB21033002-UK deciaration of conformity can be downloaded on
we’w.se.cornck.
- IEEE 802.15.4 operating frequency: 2400-2483.5 MHz.
- Maximum radio-frequency power transmitted: < 10 mW.
USA
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20 cm
between the radiator & your body.
This equipment can only be used within Schneider Electric or Square D circuit
breaker.
Canada
Industry Canada Statement
-
This device complies with RSS-247 of the Industry Canada Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and -
this device must accept any interference received, including interference that may cause undesired operation.
Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20 cm
between the radiator & your body.
This equipment can only be used within Schneider Electric or Square D circuit
breaker.
Sch neider Electric Industries SAS
35, rue Joseph Monier CS 30323
F – 92506 Rueil Malmaison Cedex
www.se.com
NNZ8881001-00
Schneider Electric Limited
Stafford Park 5 U K
Telford, TF3 3BL Cc A
United Kingdom
www.se.com/uk
© 2021 Schneider Ele AtiQmns reserved.
Printed on 2022/02/18
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>