vmacair A800070 Air Aftercooler Owner’s Manual

June 15, 2024
vmacair

vmacair A800070 Air Aftercooler

vmacair-A800070-Air-Aftercooler-PRODUCT

Product Information

Specifications

  • Product Name: VMAC Accessory A800070 Air Aftercooler (70 cfm)
  • Manufacturer: VMAC
  • Website: www.vmacair.com

Product Usage Instructions

Installation

  1. Ensure the vehicle is parked in a safe and level area.
  2. Locate a suitable mounting location for the VMAC Accessory A800070 Air Aftercooler.
  3. Securely mount the aftercooler using the provided mounting hardware.
  4. Connect the aftercooler to the air compressor system using the appropriate hoses and fittings.
  5. Double-check all connections for tightness and proper alignment.

Operation

  1. Start the vehicle’s engine.
  2. Turn on the air compressor system.
  3. Monitor the air pressure and temperature readings on the aftercooler.
  4. If necessary, adjust the settings to maintain the desired air pressure and temperature.

Maintenance

  1. Regularly inspect the aftercooler for any signs of damage or leaks.
  2. Clean the aftercooler as needed to remove any dirt or debris.
  3. Check and replace the filters as recommended by the manufacturer.
  4. Refer to the VMAC Knowledge Base or contact VMAC Technical Support for any troubleshooting or maintenance issues.

FAQ

Q: What is the maximum airflow capacity of the VMAC Accessory A800070 Air Aftercooler?
A: The A800070 Air Aftercooler has a maximum airflow capacity of 70 cfm.

Q: Are there any other models available for higher airflow requirements?
A: Yes, for systems requiring between 80 cfm and 185 cfm, you can consider the VMAC Air Aftercooler 185 CFM (P/N: A800185).

Q: What should I do if I have questions or need more information?
A: If you have any questions regarding the installation, operation, or maintenance of the VMAC Accessory A800070 Air Aftercooler, please contact VMAC Technical Support at 888-241-2289 or visit the VMAC Knowledge Base at kb.vmacair.com.

Installation and Owner’s Manual for VMAC Accessory A800070
Air Aftercooler (70 cfm)

www.vmacair.com

VMAC – Vehicle Mounted Air Compressors
VMAC Technical Support: 888-241-2289
VMAC Knowledge Base: kb.vmacair.com

Document: 1930093
Changes and Revisions

Revision

|

Revision Details

|

Revised by

| Checke| d by|  |

Implemented

---|---|---|---|---|---|---
Eng.| Tech.| Qual.
Mech.| Elec.
L| ECN: 21-049 Add DTM instructions| MSP| N/A| ASE| MSP| N/A| 17 Mar. 2021
M| ECN: 21-102 Update MF connection diagram| MSP| N/A| AJH| DSB| N/A| 21 May 2021
N| ECN: 23-178 Update IPL| MSP| GJM| N/A| MSP| N/A| 14 Aug. 2023

Additional Application Information
For use with system up to 70 cfm*.
For systems requiring between 80 cfm and 185 cfm, see the VMAC Air Aftercooler 185 CFM (P/N: A800185).

Registered Trademarks
All trademarks mentioned in this manual are the property of their respective owners. VMAC’s use of manufacturers’ trademarks in this manual is for identification of the products only and does not imply any affiliation to, or endorsement of said companies.
Loctite®, Loctite® 242 and Loctite® 567 are registered trademarks of Henkel AG & Company KGaA.

Important Information
The information in this manual is intended for certified VMAC installers who have been trained in installation and service procedures and/or for anyone with mechanical trade certification who has the tools and equipment to properly and safely perform the installation or service. Do not attempt installation or service without the appropriate mechanical training, knowledge and experience.
Follow all safety precautions. Any fabrication for correct fit in modified vehicles must follow industry standard “best practices”.

Notice
Copyright © 2021 VMAC Global Technology Inc. All Rights Reserved. These materials are provided by VMAC for informational purposes only, without representation or warranty of any kind, and VMAC shall not be liable for errors
or omissions with respect to the materials. The only warranties for VMAC products and services are those set forth in the express warranty statements accompanying such products and services, if any, and nothing herein shall be construed as constituting an additional warranty. Printing or copying of any page in this document in whole or in part is only permitted for personal use. All other use, copying or reproduction in both print and electronic form of any part of this document without the written consent of VMAC is prohibited. The information contained herein may be changed without prior notice.

Printed in Canada

Safety

Important Safety Notice
The information contained in this manual is based on sound engineering principles, research, extensive field experience and technical information. Information
is constantly changing with the addition of new models, assemblies, service techniques and running OEM changes. If a discrepancy is found in this manual, contact VMAC Technical Support prior to initiating or proceeding with installation, service or repair. Current information may clarify the issue. Anyone with knowledge of such discrepancies, who proceeds to perform service and repair, assumes all risks.
Only proven service procedures are recommended. Anyone who departs from the specific instructions provided in this manual must first ensure that their safety and that of others is not being compromised, and that there will be no adverse effects on the operational safety or performance of the equipment.
VMAC will not be held responsible for any liability, consequential damages, injuries, loss or damage to individuals or to equipment as a result of the failure of anyone to properly adhere to the procedures set out in this manual or standard safety practices.
Safety should be the first consideration when performing any service operations. If there are any questions concerning the procedures in this manual, or more information is required, please contact VMAC Technical Support prior to beginning work.

Safety Messages
This manual contains various warnings, cautions and notices that must be observed to reduce the risk of personal injury during installation, service or repair and the possibility that improper installation, service or repair may damage the equipment or render it unsafe.

| This symbol is used to call attention to instructions concerning personal safety. Watch for this symbol; it points out important safety precautions, it means, “Attention, become alert! Your personal safety is involved”. Read the message that follows and be aware of the possibility of personal injury or death. As it is impossible to warn of every conceivable hazard, common sense and industry standard safety practices must be observed.
---|---
| This symbol is used to call attention to instructions on a specific procedure that if not followed may damage or reduce the useful life of the compressor or other equipment.
| This symbol is used to call attention to additional instructions or special emphasis on a specific procedure.

Warranty

For complete warranty information, including both VMAC Standard Warranty (Limited) and VMAC Lifetime Warranty (Limited) requirements, please refer to our current published warranty located at: www.vmacair.com/warranty
If you do not have access to a computer, please contact us and we will be happy to send you our warranty.
VMAC’s warranty is subject to change without notice.
VMAC Lifetime Warranty (Limited)

A VMAC lifetime I imited Warranty is offered on the base air compressor only and only on UNDERHOOD, Hydraulic Driven, Transmission Mounted, Gas and Diesel Engine Driven Air Compressors, Multifunction Power Systems, and other products as defined by VMAC, provided that (i) the purchaser fully completes and submits a warranty registration form within 3 months of purchase, or 200 hours of operation, whichever occurs first; (ii) services are completed in accordance with the Owner’s Manual; (iii) proof of purchase of applicable service kits are made available to VMAC upon request.
The VMAC Lifetime Warranty is applicable to new products shipped on or after 1 October, 2015.

Warranty Registration
Warranty registration for VMAC systems can be completed online or by filling in the form at the back of each system installation manual. Warranty registration must be completed and sent to VMAC at the time the system is put into service for any subsequent warranty claim to be considered valid.
There are 4 ways the warranty can be registered with VMAC:

www.vmacair.com/warranty
warranty@vmacair.com
877-740-3202
VMAC – Vehicle Mounted Air Compressors

VMAC Warranty Claim Process

VMAC warranty work must be pre-authorized by VMAC. Claims are processed via our dealer network. If you are not a VMAC dealer, please select one to work with via our Dealer Locator: https://www.vmacair.com/dealer-locator/

  1. Communicate with VMAC Technical Support at 1-888-241-2289 or
    tech@vmacair.com to help diagnose/troubleshoot the problem prior to repair. VMAC technical support will require the VMAC System ID, hours on the compressor and mileage on the vehicle.

  2. VMAC will provide direction for repair or replacement of the failed components.

  3. If requested, failed parts must be returned to VMAC for evaluation.

  4. Dealers may login to the VMAC website to view the “VMAC Labour Time Guide” (under “Agreements”) to see the allowable warranty labour times.

  5. Warranty invoices must include the Service Ticket number, VMAC System ID#, hours on the compressor, and a detailed description of the work performed.

  6. VMAC Warranty does not cover consequential damages, overtime charges, mileage, travel time, towing/recovery, cleaning or shop supplies.

  7. Dealers submit warranty claims on behalf of the Vehicle Owner/End User affected by the defective part(s). The dealer ensures that all warranty credits are refunded back to the Vehicle Owner/End User who made the initial warranty claim.

In order to qualify for Lifetime Warranty (Limited), the completed warranty registration form must be received by VMAC within 3 months of the buyer receiving the Product(s), or 200 hours of operation, whichever occurs first.
If the completed warranty registration form has not been received by VMAC within 3 months of the buyer receiving the Product(s), or 200 hours of operation, the “Standard” warranty period will be deemed to commence 30 days from the date of shipment from VMAC.
Failure to follow the warranty claim process may result in denial of the warranty claim.

VMAC Product Warranty Policies & Warranty Registration can be found on the VMAC website (see previous page for URL).

General Information

Optional Equipment Compatibility
While VMAC strives to design systems compatible with optional OEM equipment (such as running boards), it is impractical to develop systems that accommodate every OEM and aftermarket option or add-on. Whenever possible, VMAC endeavors to advise of compatibility issues in the “Additional Application Information” section of the manual. Even when specific optional equipment is determined by VMAC to be incompatible, it does not preclude the vehicle upfitter or end user from modifying the optional equipment to make it compatible with the installed VMAC system. VMAC does not warrant or accept responsibility or liability for the fitment, function, or safety of any products modified in any way not expressly outlined in the installation manual.

Before Starting

Note and label all parts that are removed from the vehicle as many of the OEM parts will be reused during the installation of the VMAC system.
Read this manual prior to beginning the installation to ensure familiarity with the components and how they will fit on the vehicle. Identify any variations from the application list such as vehicle model, engines, or optional equipment (e.g., dual alternator, active steering assist, etc.).
Open the package, unpack the components and identify them using the Illustrated Parts List (IPL) included in the Fastener Pack.

Hose Information
Depending on other installed equipment, it might be necessary to move the air/oil separation tank from its intended location. The hoses used in VMAC compressor systems have a specific inner liner that is compatible with VMAC compressor oil. Use of hoses other than those supplied or recommended by VMAC may cause compressor damage and may void your warranty. Please contact VMAC for replacement hoses and further information.

Ordering Parts
To order parts, contact a VMAC dealer. The dealer will ask for the VMAC serial number, part number, description and quantity. Locate the nearest dealer online at www.vmacair.com/dealer-locator or call 1-877-912-6605.

Special Tools Required
None

Torque Specifications

All fasteners must be torqued to specifications. Use manufacturers’ torque values for OEM fasteners.
The torque values supplied in Table 1 are intended for VMAC supplied components, or for use as a guide in the absence of a torque value provided by an OEM.

Apply Loctite 242 (blue) to all fasteners (except nylon lock nuts) unless otherwise stated.

Torque values are with Loctite applied unless otherwise specified.

Table 1 — Torque Table

Standard Grade 8 National Coarse Thread

Size (in)| 1/4| 5/16| 3/8| 7/16| 1/2| 9/16| 5/8| 3/4
Foot pounds (ft•lb)| 9| 18| 35| 55| 80| 110| 170| 280
Newton meter (N•m)| 12| 24| 47| 74| 108| 149| 230| 379
Standard Grade 8 National Fine Thread

Size (in)| 3/8| 7/16| 1/2| 5/8| 3/4
Foot pounds (ft•lb)| 40| 60| 90| 180| 320
Newton meter (N•m)| 54| 81| 122| 244| 434
Metric Class 10.9

Size (mm)| M6| M8| M10| M12| M14| M16
Foot pounds (ft•lb)| 4.5| 19| 41| 69| 104| 174
Newton meter (N•m)| 6| 25| 55| 93| 141| 236

Illustrated Parts List

vmacair-A800070-Air-Aftercooler-FIG- \(5\)

Item Part # Qty Description
1 1500596 4 VIBRATION MOUNT,NAT RUBBER, 1/4-20
2 1550527 4 NUT, NYLOK, S/S, 1/4-20
3 1570499 4 WASHER, FLAT, THICK, SS 1/4
5 3550734 1 FAN ASSEMBLY AND HARNESS A800070
5.1 3500666 1 RELAY
6 3600124 1 COOLER, #16 ORB PORTS
7 3600119 1 FILTER, GENERAL PURPOSE
8 5000168 1 VALVE, MANUAL DRAIN
9 5000212 1 CONNECTOR,BRASS, FNPT-POLY, 1/8-1/4
10 3100033 1 ADAPTOR, STR, 3/4 X 1-5/16 UN, ADJ
11 3200331 1 ADAPTOR, 3/4” X 3/4” NPT
12 1700055 36” HOSE, BRAKE BLACK, 1/4
13 A700143 1 OPTIONAL MOUNT KIT, A800070
13.1 1200495 2 BRACKET, AFTER-COOLER
13.2 1550221 4 NUT, HEX NC PL, 1/4, GR8
13.3 1570038 4 WASHER, FLAT SAE, 1/4
14 3200350 1 ADAPTOR, AFTER-COOLER
15 6000458 1 COVER, AIR DRYER
15.1 2200171 1 CLIP, STRAIN RELIEF, 5/8
15.2 5800093 1 GROMMET, RUBBER BUNA, 5/16
16 1500587 29 SCREW, SL, MC IND HEX 10-32 X 3/8-SS
17 1570488 28 WASHER, NYLON, 3/16
18 6000457 1 PANEL, REAR, AIR DRYER
18.1 1500688 6 SCREW,SL,MC IND HEX 10-32 X 5/8-SS
18.2 1570163 6 WASHER, FLAT, 3/16
18.3 1550524 6 NUT, NYLOCK, 10-32
19 6000456 1 TRAY, BASE, AIR DRYER
20 6000455 1 PANEL, FRONT, AIR DRYER

Operation

In extreme cold temperatures, moisture in the drain lines can freeze within minutes, to prevent a blockage, open the manual drain immediately after use.

Daily Operation
At the end of each shift, shut the compressor system down and vent any stored air. Open the manual drain valve, on the side of the cooler, to drain the air line; this will prevent the water in the float bowl from freezing in cold temperatures which will cause the automatic water drain to fail. Leave the valve open until the compressor is started again.

Manual Drain
The VMAC air aftercooler has a manual drain valve to purge water from the ‘Air-In’ line entering the aftercooler.

Installation

Install the VMAC Air Aftercooler 70 CFM in a location that provides adequate air flow and easy accessibility.
The unit should have a minimum of 8 in of clearance on all sides. Ensure there is sufficient space to: remove the front panel, connect the air lines, connect the wiring, and access to the manual drain.
The manual drain function can be placed in a remote location by removing the drain valve and connecting a hose, rated for a minimum of 200 psi, between the aftercooler and the relocated drain valve.
The aftercooler must be mounted upright to allow the automatic drain to function as designed (Figure 1).

vmacair-A800070-Air-Aftercooler-FIG- \(7\)

Place the aftercooler in position and drill the mounting holes (Figure 2).

vmacair-A800070-Air-Aftercooler-FIG- \(8\)

  • Fasten the rubber mount feet securely. If using the optional VMAC mounting brackets (P/N: A700143), install the aftercooler unit onto the brackets and fasten securely.
  • Route the black nylon water drain tube to a suitable drain location.
  • Connect the supply line from the air source to the “Air In” fitting (the recommended hose size is #12 hose). Support the fitting on the aftercooler with a wrench when tightening.
  • Connect the tool delivery line to the “Air Out” fitting, (the recommended hose size is #12 hose). When tightening, support the fitting on the aftercooler with a wrench.
  • Connect the red wire from the aftercooler through a 20 A fuse to a 12 V (constant) source using the recommended wire size (Table 2).

Table 2 — Recommended wire size

Wire length Recommended wire gauge
Less than 5 ft (1.5 m) 14 AWG
Between 5 ft (1.5 m) and 8 ft (2.5 m) 12 AWG
Above 8 ft (2.5 m) 10 AWG

To confirm a good ground, use an ohm meter to measure the resistance between the ground point and the negative battery terminal. Resistance should be less than 1 Ω.

  • Connect the green wire to a good ground using the recommended wire size (Table 2).

System specific installation instructions continue on the next page.

VMAC UNDERHOOD 30 / 40 / 70 Systems

  • Connect the red wire from the aftercooler to a 12 V source (see page 13).
  • Connect the green wire from the aftercooler to a good ground (see page 13).
  • Connect the white wire from the aftercooler to the white clutch wire coming from the VMAC compressor (Figure 3).

vmacair-A800070-Air-Aftercooler-FIG- \(9\)

VMAC Direct Transmission Drive (DTM) Systems

  • Connect the red wire from the aftercooler to a 12 V source (see page 13).
  • Connect the green wire from the aftercooler to a good ground (see page 13).
  • Connect the white wire from the aftercooler to the white wire coming from the white 4 pin interface plug that connects to the Control Box (Figure 4).

vmacair-A800070-Air-Aftercooler-FIG- \(10\)

VMAC Hydraulically Driven Systems (40 cfm – 60 cfm)

  • Connect the red wire from the aftercooler to a 12 V source (see page 13).
  • Connect the green wire from the aftercooler to a good ground (see page 13).
  • Connect the white wire from the aftercooler to the red wire coming from the Hydraulically Driven Air Compressor (Figure 5).

vmacair-A800070-Air-Aftercooler-FIG- \(11\)

VMAC Diesel Driven Air Compressor (60 cfm)

  • Connect the green wire from the aftercooler to a good ground (see page 13).
  • Connect the red wire from the aftercooler to the red post with red wires located near the Control Box (inside the service panel).
  • Connect the white wire from the aftercooler to the red post with orange wires located near the Control Box (Figure 6).

vmacair-A800070-Air-Aftercooler-FIG- \(12\)

VMAC Multifunction Power System (Cat C1.1 and Kubota)

  • Connect the green wire from the aftercooler to a good ground (see page 13).
  • Connect the red wire from the aftercooler to the red post with red wires located near the Control Box (inside the service panel).
  • Connect the white wire from the aftercooler to the white compressor clutch wire (Figure 7).

vmacair-A800070-Air-Aftercooler-FIG- \(13\)

VMAC Honda Gas Driven Air Compressor
Please contact VMAC Technical Support for information.

Connection to non VMAC equipment

  • Connect the white wire from the aftercooler to the power source via an on/off switch using 18 AWG wire.

Warranty Registration

This form must be fully completed and returned to VMAC at the time the vehicle is put into service. Warranty may be void if this form is not received by VMAC within 3 months of receiving the vehicle, or 200 hours of operation, whichever occurs first.
VMAC’s Warranty policy and registration can be viewed online at: www.vmacair.com/warranty

Product Information

Accessory Serial Number: A

Owner / End User Information

Company Name:
City:
State / Province:
Phone:
Email Address:
Date vehicle was put into service:
Day
Month
Year

Installer Information

Installer Company Name:
City:
State / Province:

Submitted by

Name:
Phone:
Email:

Vehicle Information (Optional)
Unit:
Year:
Make:
Model:
Vehicle Identification Number:

888-241-2289 tech@vmacair.com
877-740-3202 warranty@vmacair.com
www.vmacair.com kb.vmacair.com
1333 Kipp Road, Nanaimo, B.C., V9X 1R3 Canada

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals