Ready Clim Connections for R32 or R410A Gas Installation Guide

June 4, 2024
Ready Clim

Ready Clim Connections for R32 or R410A Gas

INSTRUCTION

Ready-Clim-Connections-for-R32-or-R410A-Gas-FIG-1

  1. Risk of fire only for R32 gas
  2. Read the user manual (ISO 7000-0790)
  3. User Manual; user instructions (ISO 7000-1641)
  4. Maintenance indicator; read the technical manual (ISO 7000-1659)

WARNING the correct correspondence of the connections and adapters
The threads of the READYCLIM R32 and R41 OA system connectors are not compatible. Do not force and carefully check the concordance of the gas used in the READYCLIM connections with the indoor(s) and outdoor units.

HOW TO USE

  1. Carefully unroll and position your refrigeration connection between the indoor(s) and outdoor units.

  2. Remove the protective caps
    A1 and A2 adapters and your unitsReady-Clim-Connections-for-R32-or-R410A-
Gas-FIG-2

  3. Make sure that all the threads are in good condition and that there is no sand or other particles.

  4. Screw the quick connections 1 and 2 onto the respective adapters A 1 and A2 axially, by hand at first, then finish with 2 spanners (one positioned on the quick connection to screw and the other positioned on the adapter to hold it in place until it stops Identical operations to be carried out for all the other connections.

    • 1 on A 1 (small 0, 1/4)
    • 2 on A2 (large 0, 1/2 or 3/8)
  5. Remove the protective caps from the VE shut-off valves.

  6. To pressurize the refrigerant gas circuit: Fully unscrew the shut-off valves of the VE outdoor unit using the Alen key.

  7. Check that your connection is perfectly sealed at the connections (pay your attention to any hissing, traces of grease). Immediately carry out a leak detection test with soapy water. The appearance of bubble means micro leaks. In this case, close the shut-off valves as quickly as possible, check your tightenings and repeat step 6.

  8. After positive control of your connection, place the insulation sleeves on connectors 1 and 2 and adapters A 1 and A2 to avoid any risk of icing.

Quick connectors 1&2 of your refrigeration connection

Ready-Clim-Connections-for-R32-or-R410A-Gas-FIG-3

AT WARNING GAS R32
In the event of dismantling a fitting of a READYCLIM connection positioned at! INTERIOR of a building, changing the seal of the READYCLIM fitting is MANDATORY.
To make a seal kit, with tool and assembly instructions is at your disposal ref409596.

READYCLIM connections contain fluorinated greenhouse gas R32 or R41OA. R32, and R41OA are so-called “Ecological” gases because they are chlorine-free and respect the ozone layer. You will find on each sealed hermetic system of your air conditioner a label indicating the gas charge and its nature. Any intervention on the sealed junctions of the indoor and outdoor units must be carried out in accordance with the rules of the art, by a qualified operator and with the appropriate equipment (recovery station and vacuum pump). Dismantling and recycling: the connections contain refrigerant gas. It is therefore imperative to unload the entire installation before dismantling any connector with a view to recycling the installation and the connections.
*See air conditioner warranty booklet
STARLIGHT – 255 Bd de la madeleine FR-06000 Nice
V-01-2019

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals