Haier HPB08XCM Portable Air Conditioners User Manual
- June 15, 2024
- Haier
Table of Contents
- Haier HPB08XCM Portable Air Conditioners User Manual
- SAFETY PRECAUTIONS
- Important Instructions
- Assembly and Installation
- Accessories Include
- Parts and Features
- Operation
- BEFORE USE
- Remote Control Operation
- Care and Cleaning Guide
- Storage
- Troubleshooting
- Limited Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Haier HPB08XCM Portable Air Conditioners User Manual
Please read the instructions carefully before operating the air conditioner.
A Word From Haier America
Thank you for buying a dependable, energy-saving, and easy-to-operate Haier
air conditioner. This manual contains useful information for you to maintain,
operate, install and safely use your air conditioner. Your air conditioner
cleans, cools, and dehumidifies the air in your room to provide you with the
ultimate level of comfort. Please read the instructions carefully before using
the product. Also, do not forget to fill out and mail in the Product
Registration Card.
Product Registration
Keep a record of your model and serial numbers. Attach the sales receipt to
this guide and keep it for future reference. The model and serial number can
be obtained from the serial label, which is on your air conditioner. For all
your service calls during the warranty period the following information will
be needed:
SAFETY PRECAUTIONS
WARNING
Read all of the instructions before using this appliance. When using
- A this appliance, always exercise basic safety precautions, including the following:
- Air conditioner must be connected to proper electrical outlet with the correct electrical supply.
- Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR
REMOVE THE GROUNDING PRONG
- If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle.
- The wall receptacle MUST be properly grounded. A 3) Do not operate the air conditioner if the power cord is frayed or otherwise damaged.
- Avoid using it if there are cracks or abrasion damage along the length, plug connector or if the unit malfunctions or is damaged in any manner.
- Contact an authorized service technician for examination, repairs or adjustments.
- DO NOT USE AN ADAPTER OR AN EXTENSION CORD. Do not block airflow around the air conditioner.
- The exhaust hose should be free of any obstructions.
- Always unplug the air conditioner before servicing it or moving it.
- Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the atmosphere is oily or sulphurous.
- Avoid any chemicals coming in contact with your air conditioner.
- Do not place any object on the top of the unit.
- Never operate the air conditioner without the filters in place.
- Do not use the air conditioner near a bathtub, shower or wash basin.
SAVE THESE INSTRUCTIONS
CAUTION! If the air conditioner has been placed in a horizontal or tilted
position for any period of time, wait 24 hours before plugging the unit in.
Important Instructions
- Please keep this manual in a safe place.
- Do not use liquid or a spray to clean this product. Use a damp cloth.
- Do not place the product in an insecure or elevated place as it may fall and cause damage or injury.
- Never spill liquid on the control panel; it may cause electrical shock to the electronic parts inside and disable them or cause them to function improperly.
- Never try to dismantle the product by yourself as this will void the warranty.
- Unsupervised dismantling and incorrect reassembly of the inside of the back cover may damage the electrical circuit and affect its performance. When maintenance is required, please contact the local service center or local distributor.
- For responsible disposal of the product, please contact your local municipality for additional recycling options in your area.
Assembly and Installation
Accessories Include
- Main window panel and extension panels – extends from 20″ up to 46″ …………….. 3 pieces
- Exhaust nozzle ……………………………. 1 piece
- Screws …………………………………….. 8 pieces
- Exhaust hose ……………………………… 1 piece
- Cover ……………………………………… 1 piece
- Foam ………………………………………. 2 pieces
- Hose connector …………………………… 1 piece
Connect the 3 pieces of the window panels by sliding the 2 extension panels into the main window panel.
Apply a foam strip to the end of each extension panel. Open the window and place the window panel assembly into the window.
Adjust the extension panels to fit the width or height of the window as shown below (see figure A). Secure the extension panels using 4 blunt tip screws (see figure B-1 ). Secure the main window panel using 4 pointed screws (see figure B-2 and B-3).
Expand the 2 ends of the exhaust hose. Connect the hose connector to one end of the exhaust hose by turning clockwise. Then insert the exhaust nozzle at the other end of the exhaust hose by turning clockwise (see figure C) to create the hose assembly. 5)Slide the hose connector end (the square end) of the hose assembly into the rear of the unit (see figure D). 1nsert the exhaust hose with nozzle end into the window panel(see figure E). Plug the power cord into the wall outlet and press the “Reset”button. Please allow 8” of space around the unit for proper air circulation. When removing the portable air conditioner for storage, the window panel may be left in place. Simply place the cover over the nozzle hole (see figureA).
Parts and Features
-
Control panel
-
Air outlet
-
Handle hole
-
Caster
-
Air filter
-
Exhaust Hose Connection
-
Air Intake
-
Upper Drain
-
Lower Drain
(Note : Please ensure if the water outlet drain is well installed before use.) -
Power supply cord
POWER CORD
TEST: When this button is pressed or when there is a current leak, the
unit will not operate.
RESET: After resolving the problem, press the reset button to resume
operation.
Operation
NOTE
Wait 24 hours before turning on the air conditioner if the unit has been
tilted for any reason. This allows the oils and the coolants to settle and
level off.
BEFORE USE
- Use an 115V, l 5Amp outlet for the air conditioner. Do not use any other electrical appliances on this line or you may trip the fuse. Use a dedicated line for this air conditioner.
- Do not place the air conditioner in direct sunlight or close to any heating appliances (ie., baseboard heaters, stoves, etc.)
- Operate on a flat surface only.
- Keep the unit free of any obstructions such as drapes, curtains, blinds, etc.
- Keep unit at least l foot away from the wall.
DURING USE
- When turning on the unit for the first time after plugging it into an electrical outlet, the unit will start in a high fan cooling mode.
- The temperature display on the LED will show the current room temperature. When turning on the unit during regular usage, it will remember the last setting used.
- If you want to operate the air conditioner as a dehumidifier, then adjust to dehumidification mode.
- After a normal shut down, wait for 3 minutes before restarting the unit so as to complete the compressor cycle.
- In cooling mode, this portable air conditioner should not require water to be removed. The unit has a unique design which continuously evaporates the water. In heating mode, or when the unit is operated in high humidity conditions, you may need to empty the water tank periodically. The unit will shut down automatically when the water tank is full and the “Tank Full” warning light will turn on.
- To empty the water tank: Place a shallow pan (not included) below the lower drain located on the back of the unit (near the bottom of the air conditioner), remove plug, and drain the water tank completely. Re-insert the drain plug. You will then be able to restart your portable air conditioner.
- Check and clean the filter once every week for highest efficiency.
NOTE: Do not operate unit without filter.
AFTER USE
If the unit is not being used for a long period of time, drain the water from
the water tank. Please see step 4 of the “During Use” section above for more
information.
Control Pane
Power Control
The power control turns the unit on ond off.
Warning Light CD
Condensed water may accumulate in the unit. If the internal tank becomes full,
the warning light will light up and the unit will not operate until the unit
has been drained.
Mode Control
The Mode Control has three settings:
- Cool
- Dehumidify
- Fan
The settings ore adjusted with Mode Control button. A light will indicate which setting is currently being used.
Cooling Mode
When cool mode is selected, the indicator light turns blue. During the cooling
mode the air is cooled and hot air is exhausted to the outside through the
exhaust tube. Adjust fan speed and air temperature to suit your desired
comfort level.
Note : The air exchange hoses must vent outside the room when using cool
mode.
Dehumidify Mode
When dehumidify mode is selected, the indicator light turns yellow. Air is
dehumidified as it passes through the unit, without being in full cooling
mode. If room temperature is higher than 77 degree Fahrenheit , fan speed can
be adjusted;
other wise fan speed is fixed to ” Low “.
Note: If the unit is to be used as a dehumidifier, do not connect the
exhaust hose let the warm air return to the room. Continuous drainage is then
necessary.
Fan Mode
When fan mode is selected the indicator light will shine green. Air is
circulated throughout the room with no cooling.
Note: unit does not need to be vented in Fan mode
Fan Speed Control
The Fan Speed Control has 2 settings: High and Low.
Timer
-
Auto turn off :
With machine in running mode, press timer button to Select number of hours you would like the unit to run in air conditioning mode until it automatically shuts off. -
Auto turn on :
With machine in stand by mode, press timer button to Select number of hours until you would like the unit to automatically start running in air conditioning mode.
Timer / Temp set controls
-
Used for adjusting the timer and thermostat.
-
The default display is room temperature.
-
In cooling mode, when or button is pressed, the set temperature is displayed and moy be adjusted.
-
After 15 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between l ~24 hours.
Note: By pressing both Timer/ Temp set buttons at the same time, the display will toggle between Celsius and Fahrenheit. The temperature cannot be adjusted in the fan or dehumidification modes. -
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
Remote Control Operation
-
Power On / Off
-
Mode
- Cool: Blue LED lights when in cooling mode .
- Dehumidification: Yellow LED lights when in dehumidification mode.
- Fan: Green LED lights when in fan mode .
-
Fan Speeds There are 2 adjustable speeds in the cool and fan mode:
Low and High. In dehumidification mode, and room temperature is greater
than 77°F, fan speed can be adjusted; otherwise fan speed is fixed to “low.” -
On / Off Timer
To set the Timer for a 1 to 24-hour delay until the air conditioner turns off: When you use the timer setting button while the unit is operating, you can preset a time for the unit to turn off. When you use the timer setting button while the unit is on standby, you can present a time for the unit to turn on. If you press the “ON/OFF” button, the preset timer function will be cancelled. Timer setting range is l ~24 hours.
To clear Timer Delay program
NOTE: Air conditioner can be either on or off -
Press the Ti mer button.
-
Press and hold the minus button until the timer display has cleared.
To change the remaining time (in hours): -
Press the Ti mer button.
-
Press the plus or minus button to change the delay time from l to 24 hours.
-
The new delay time will display.
Setting the Temperature
To set the temperature, press the El or B key to raise or lower the temperature. The temperature can be raised or lowered in the cool mode. The temperature cannot be adjusted in fan or dehumidification mode.
NOTE: The temperature can be set between 61 °F to 89 °F (Cool mode) and 6 l° F to 80°F (Heat mode).
WARNING
Batteries can explode, or leak, and can cause injury or fire.
To reduce the risk
- Carefully follow all instructions and warnings on the battery label and packaging. Always insert batteries correctly with regard to polarity(+ and -) marked on the battery and the equipment.
- Do not short battery terminals.
- Do not charge batteries.
- Do not mix old and new batteries.
- Replace all of them at the same time with new batteries of the same brand and type. Remove dead batteries immediately and dispose of per local codes.
- Do not dispose of batteries in re.
- Keep batteries out of the reach of children.
- Remove batteries if the device will not be used for several months.
Care and Cleaning Guide
- Always unplug your air conditioner before cleaning.
- Air filter needs to be cleaned at least once a week for your unit to operate at optimum efficiency. Slide out the filter from the back by pulling on the tab. The filter may be washed or vacuumed.
- Remove the excess water from the filter by gently shaking the filter. This will remove dust and particles trapped in the filter. After cleaning, reinstall the filter. DO NOT use your air conditioner without the air filter in place.
- To clean the cabinet, DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads. Some of these chemicals may dissolve, damage and/or discolor your air conditioner.
- Always use a soft cloth dampened with water or a mild soap and water solution to wipe the front of the cabinet. Wipe dry with a soft cloth.
Storage
- To store your air conditioner when not being used for a long period of time, drain the water tank as described on page 6 under the “During Use” section, step 4.
- Remove exhaust hose, clean the filters, cover with plastic bag and store away.
Troubleshooting
If air conditioner does not operate:
- Check if unit is plugged in. The plug may have come loose.
- Press “Reset” button on the plug to resume operation.
- Check if the electrical wall receptacle is the proper voltage.
- Check if the circuit breaker needs to be reset or if the fuse needs to be replaced.
- Check if the unit is in “Off” mode.
- If the warning light is on, drain the water drain pipe by removing the plug.
Air conditioner working but room not cooling
- Room may have appliances that produce heat. Use an exhaust fan to remove excess heat.
- Check exhaust hose for proper installation.
- Redirect the airflow. Remove any obstacles.
- All doors and windows need to be closed so that cool air does not escape the room.
- Air filter may be blocked or may need cleaning.
- Unit BTU may be too low for the required cooling area.
- On extremely hot & humid days, air conditioners may take a little longer to cool.
- Drain the water drain pipe by removing the plug.
- Unit may be in fan or dry mode. Put air conditioner in cool mode.
- Tank Full Warning Light Is On:
- Unit will shut down when the water pan is full. This condition may occur either when the unit is operated in high humidity conditions, or when the unit is operated in HEAT MODE, since the auto-evaporation function will not work in the heating mode. See instructions in the “Operation” section under “During use”.
Limited Warranty
What is covered and for how long?
This warranty covers all defects in workmanship or materials for a period of:
- 1 year parts (carry in only)
- 1 year labor (carry in only)
The warranty commences on the date the item was purchased and the original purchase receipt must be presented to the authorized service center before warranty repairs are rendered.
EXCEPTION: Commercial or Rental Use Warranty
- 90 days labor (carry-in only)
- 90 days parts
- No other warranty applies
What is covered.
- The mechanical and electrical parts, which serve as a functional, purpose of this appliance for a period of 1 year. This includes all parts except finish, and trim.
What will be done?
- We will repair or replace, at our discretion any mechanical or electrical part which proves to be defective in normal usage during the warranty period so specified.
- There will be no charge to the purchaser for parts and labor on any covered items during the initial 1 year period. Beyond this period only parts are covered in the remaining warranty.
- Labor is no provided and must be paid by the customer.Contact customer service: 1-877-337-3639.
THIS WARRANTY COVERS APPLIANCES WITHIN THE CONTINENTAL UNITED STATES, PUERTO RICO AND CANADA. IT DOES NOT COVE
THE FOLLOWING
Damages from improper installation. Damages in shipping. Defects other than
manufacturing. Damage from misuse, abuse, accident, alteration, lack of proper
care and maintenance or incorrect current or voltage. Damage from other than
household use. Damage from service by other than an authorized dealer or
service center. Decorative trims or replaceable light bulbs. Transportation
and shipping. Labor (after the initial 1 year).
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or consequential damages, so the above limitations may not apply to you. Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary, from state to state. Wayne, NJ 07470
IMPORTANT
Do Not Return This Product To The Store If you have a problem with this
product, please contact the “Haier Customer Satisfaction Center” at
1-877-337-3639.
DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE
Download PDF:Haier HPB08XCM Portable Air Conditioners User Manual
Read User Manual Online (PDF format)