The new UTY-RVRU Kagami Controller is a touch enabled, intuitive and stylish- looking controller, compatible with 2-Wire H, J, and V-Series indoor units.

Features

  • Sleek, minimalist design that harmonizes with the space
  • Large, easy to read, anti-fingerprint touch screen with auto dimming
  • Simple, intuitive operation, with only the necessary functions and minimal screen transitions – swipe left/right to select settings, up/ down to adjust settings
  • Initial setup and function settings via BLE connection to Remo Set app on smart device, or manually on the controller
  • Easily transfer settings between controllers, reducing install time
  • Custom logo import and display and masking of settings for hotels
  • Control and monitoring for commonly used functions, including:
  • On/Off, Operation Mode, Fan Speed, and Air Flow Direction
  • Room temperature display with temperature correction
  • Current time display, adjusts for Daylight Savings
  • Auto-Off and Weekly Timers
  • Custom Auto (dual setpoint) function
  • Away / Eco Away setting
  • Economy / Energy Saving Fan / Optimum Start operation
  • Emergency Heat control
  • Filter Status and Reset
  • Anti-Freeze operation
  • Economy / Energy Saving Fan / Optimum Start operation
  • Error display and history
  • Refrigerant Cycle Monitor of select sensor values
  • Test Run function
  • Password and child lock protection
  • Multi-language
  • Energy Star Compliant
  • Meets California 2022 Title 24 requirements
  • Retains and displays HVAC contractor contact info for support
  • 90-day warranty

Blends with your decor, both residential and commercialFUJITSU UTY RVRU
Kagami Controller - FigFUJITSU UTY RVRU Kagami
Controller - Fig 1

Kagami vs. Touch Panel Controller comparison

DEVICE Kagami UTY-RVRU Touch Panel UTY-RNRUZ

EQUIPMENT
Compatible product lines| j, V, H-Series| J, V, H-Series
Max number of indoor units| 16| 16
GUI
Touch screen/color| |
Backlit/dimmable| |
Bluetooth app for install setup| |
Multi-language| |
Password/child lock| |
Custom logo import and display| |
Masking of settings| |
FUNCTIONS
Operation – On/Off| |
Operation Mode| |
Fan Speed| |
Air Flow Direction| |
Single Setpoint| |
Dual Setpoint (Custom Auto only)| |
Deadband Adjust| |
Temperature Limit| |
Set Temp Auto Return| |
Room Temp correction| |
Function Settings| |
Setting mask| |
Time display / Daylight Savings| |
On/Off Timer| |
Auto-Off Timer| |
Weekly Timer| |
Away setting| |
Eco Away setting| |
Economy operation| |
Energy Saving Fan operation| |
Optimum Start| |
Lead Lag operation| |
Emergency Heat| |
Filter Status and Reset| |
Anti Freeze| |
Test Run| |
Memory backup| |
MONITORING
Room temperature| |
Error codes| |
Emergency Stop| |
Refrigerant Cycle Monitor| |

Specifications

Power supply, consumption 12Vdc, 83mA
Power source Indoor unit through 2-wire RC interface
Display 4 inch TFT LCD (480 × 480 pixels) Touch screen, anti-fingerprint

coating
Operating temperature range| 32-104 °F (0-40 °C)
Storage temperature range| 14-140 °F (-10-60 °C)
Operating / storage humidity range| 20-90%RH (no condensation)
RoHS conformity| Compliant with RoHS directive (2011/65/EU)
Net weight oz. (g)| 7.94 (80)
H × W × D inches (mm)| 4-13/16 × 4-9/16 × 1 (121.5 × 116 × 26)
Maximum number of indoor units| 16
Device connection to IDU| 2-cond cable, #16-22AWG, stranded, unshielded
Device connection to smartphone, tablet| BLE (Bluetooth Low Energy)

Dimensions

FUJITSU UTY RVRU Kagami Controller - Dimensions

Compatible Indoor Units

H-Series:

ACUH**LUAS1  ADUH**LUAS1 AMUG**LMAS ARU**RGLX
ARUH12LUAS  ASU30RLE ASUG**LMAS  ASUG**LZAS
ASUG**LZBS ASUH**LMAS ASUH**LPAS  AUU**RGLX

J-, V-Series:
All TLAV, TLAV1, TLAV2
Remo Set App
Set up your new Kagami controller via Bluetooth from your smartphone (or directly at the controller).
Features:

  • Initial configuration
  • Function setting
  • Custom logo import
  • Copy settings between controllers

Part #6-36-FG8137 Rev. 1/2023
AIRSTAGE is a worldwide trademark of FUJITSU GENERAL LIMITED.
Actual product color may be different from the colors shown here.
Specifications and design are subject to change without notice.
FUJITSU GENERAL AMERICA, INC.