REDRAGON B0894STPY2 Red Dragon Meter Wood Moisture Meter User Guide
- June 15, 2024
- REDRAGON
Table of Contents
REDRAGON B0894STPY2 Red Dragon Meter Wood Moisture Meter
Specifications
- Detection value: Pinless
- Minimum detection area: 50*50mm
- Detection depth: 19mm
- Wall moisture level: 0-70%
- Masonry moisture level: 0-70%
- Softwood moisture level: 5-75%
- Hardwood moisture level: 5-75%
- Accuracy: Not specified
- Auto Power Off Trigger: 5 minutes
- Working conditions: Operating temperature: 5 – 95%RH
- Storage Temperature: Not specified
- Power Source : Not specified
- Dimensions : Not specified
- Weight: Not specified
Function Description
The meter is a pinless instrument that can detect moisture up to 3/4 in. (19mm) below the surface of the following materials: wallboard, masonry, hardwood and softwood.
warning: Please read this manual carefully before using this instrument, and operate and use it in accordance with the operating instructions and provisions in the manual, so that the best functions of this instrument can be brought into play. Please keep this manual after reading it.
Product schematic
Product component description
- 1. Moisture level indicator
- 2. Flashlight indicator
- 3. Analog proportion display
- 4.8.13 Moisture level icon “dry” “medium” “wet”
- 5. Softwood measurement mode (loose, low-densitywood)
- 6. Measurement mode selection button
- 7. ON/OFF button
- 9. Battery indicator
- 10. Reading display
- 11. Reading Hold Indicator
- 12. Wall measurement mode (generally referstohardwalls such as cement walls, cement floor , tilewalls,etc.)
- 14. Masonry measurement mode (generallyreferstobricks, loose stones, etc.)
- 15.Hardwood measurement mode (hard, densewood)16. Flashlight on/off button
- 17. Lock the screen on/off button, press and hold the machine for 3 seconds to enter the reference value calibration. (Note: Please don’t let the touch any thing during the calibration process, hold the instrument below buttons)
- LED of Flashlight
- Sensor
- Moisture level reference
- Wear-resistant foot pads
- Battery compartment
warning: The instrument has been calibrated before leaving the factory, in order to achieve the measurement for best results, please do not use the calibration function if there is no need.
technical parameter
Detection value
Minimum detection area| 50*50mm
Detection depth| ≤19mm
Wall moisture level| 0-70%
Masonry moisture level| 0-70%
Softwood moisture level| 5-75%
Hardwood moisture level| 5-75%
Accuracy| ±4%
Auto Power Off Trigger| 5min
Working conditions
Operating temperature| 0 – 40℃ (32-104℉)
Operating humidity| 5 – 95%RH
Storage Temperature| -10~50℃ (14~22℉)
---|---
Power Source| 1×9V battery
Dimensions| 150×67×28.5mm
Weight| 160g
Operation instructions
-
Battery
The instrument use 9V dry battery or 9V rechargeable battery. If you do not use the instrument for a long time, be sure to remove the battery from the battery compartment, otherwise, the battery will automatically discharge and leak and corrode. -
Power ON/OFF
Before starting the measurement, make sure that the sensor of the instrument is dry. If there is moisture on the sensor, please wipe it dry with a cloth before performing the measurement operation. -
Measurement
For best accuracy, please press the instrument’s sensor on the flat area of the measured material. Ideally, the thickness of the measured material should be at least 19mm.
If your test object is too thin, the instrument will measure the material below it and produce inaccurate readings. One way to compensate for thin materials is to stack measurement materials.
warning: This instrument is a capacitive value detection instrument, please do not use it for non-capacitive moisture measurement. Such as metal, conductive film and other conductive objects.
NOTE
- In the process of storage and use, you must pay attention to keep the instrument dry and clean to ensure the accuracy of the measurement.
- When the instrument is not in use, please store the instrument in a stable, dust-free, and avoid direct sunlight。
- During the use of the instrument, please do not press or knock the body strongly.
- The measuring object of the instrument is a solid Csurface, please do not use it for measuring organic liquids.
- Please do not attach the sensor of the instrument to water for measurement.
- Please use the specified battery for power
Kind reminder
The calibration mode is suitable for Benchmark adjustments made by the
instrument deviations due to environmental differences (high temperature and
high humidity, low temperature and low humidity, high altitude, and other
unconventional environments). Benchmark adjustments have an impact on each
model. The instrument may need to be calibrated if the following conditions
occur:
- When the instrument sensor is dry, turn on the instrument and far away from any measured object , the value display is not “00.0%”
- In“SOFT WOOD”mode the value will be displayed as “00.0%” when different parts are measured
maintenance
- When the battery power is low, the backlight will be dim. To ensure accurate measurement of the instrument, please replace with new batteries in time.。
- Use a dry and soft cloth to wipe off the dirt on the instrument. Do not use detergents or solvents.
- Do not stick any labels or nameplates (especially metal nameplates) on the sensor. Please use the attached protective cover to store and carry the instrument.
Waste treatment
Damaged instruments, accessories (batteries, etc.), and packaging materials must be recycled and reused in a manner that meets environmental protection requirements
Commonly tested materials
Group | Example |
---|
WALL
| ****
Lime wall, soil wall, cement wall, roof
MASONRY
| ****
Brick wall, stone wall, floor
SOFTWOOD
| ****
Lauan ,Fir, Cork, Cedar, Beech…
HARDWOOD
| Teak, Walnut, Afrormosia, Rubber Tree, Imbuia, Kokrodua, Niove Bidinkala, Keruing, White Poplar, , Tola, Ash, Elm, Maple, Padauk, Oak,
Cherry…
FAQ
- Q: Can I use this instrument for non-capacitive moisture measurement?
- A: No, this instrument is a capacitive value detection instrument and should not be used for non-capacitive moisture measurement, such as metal, conductive film, and other conductive objects.
- Q: Is calibration necessary?
- A: The instrument has been calibrated before leaving the factory. To achieve the best measurement results, please do not use the calibration function if there is no need.
Feel free to contact us
joss@reddragonmeter.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>