EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point User Guide

June 15, 2024
EnGenius

EWS2910P-FIT
EnGenius Fit L2+ Managed 55W PoE+ Switch
Quick Start Guide

Introduction

This Quick Start Guide is designed to guide you through the installation of the Fit L2+ managed 55W PoE+ switch access point, model EWS2910P-FIT, including hardware mounting and configuration.
Model: EWS2910P-FIT

  • 8 10/100/1000 Base-T GbE Ports
  • Full-featured Layer 2 plus switching
  • 802.3at/af PoE+ ready on all ports with 55W PoE budget
  • Setup in minutes with app-based step by step instructions
  • Quick-scan device register, remote monitoring and troubleshooting
  • Real-time system metrics, analytics and remote configurations

Package Contents

EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point -
parts

System Requirements

Web Browser

  • Google Chrome (57.0.2987.110 and later)
  • Microsoft Edge (80.0.361.103 and later)
  • Mozilla Firefox (52.0 and later)

Reset Button:
Reset to default: Press and hold the reset button on the PoE adaptor for over 60 seconds, and the LED (PWR) will go off and on.. Then, the device will be reset to factory default settings.EnGenius EWS2910P-FIT Fit L2 Managed 55W
PoE Switch Access Point - parts1

LEDs

LOCATION LED INDICATOR COLOR STATUS DESCRIPTION
System Power Green Flashing Before system boot
Solid On Power on
Light Off Power off
Fault Amber Solid On Any fault
Light Off Normal
PoE Max Amber Solid On When the total Poe output power archive max power

budget
Light Off| System still have spare power for new PD
LAN Mode| Green| Solid On| Select LED Mode to Ethernet Mode
PoE Mode| Green| Solid On| Select Led Mode to PoE Mode
Copper Port| LAN Mode| Green| Solid On| Speed 1000 Mbps
Amber| Solid On| Speed 100 Mbps
Off| Light Off| Speed 10 Mbps
PoE Mode| Green| Solid On| Power feeding
Amber| Solid On| Error condition
Off| Light Off| Now Power Feeding
Link/Act| Green| Flashing| Link
Amber| Solid On| Transmit or receive on this port
Off| Light Off| No link
SFP Slot| Link/Act| Green| Flashing| Link
Solid On| Transmit or receive on this port
Light Off| No link

Hardware Mounting

The access point can be mounted on the Wall and Pole, and please perform the steps for the appropriate installation.
Rack Mount

  1. Determine where the Ethernet Switch will be placed and mark the location on the surface for the two mounting holes. Use the appropriate drill bit to drill two 8.1mm diagram and 26mm-deep holes on the marks.
  2. Screw the Anchors into the holes until they are flush with the wall; screw the included Screws into the Anchors but leave the screw head sticking out so you can hang the Ethernet Switch on it.EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point - parts2

Powering EnGenius Fit Switch
EnGenius Fit Switch can be powered by following:

  • Power Adapter

Connecting to a Power Cord
Connect the Power Cord cable from the EnGenius Fit PoE+ Switch EWS2910P-FIT AP directly to the Wall Outlet. EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE
Switch Access Point - parts3

Management Plane

EnGenius Fit provides flexible options to manage your devices based on your network planning and deployment.
Option A: Cloud Management
Option B: On-Premises Management
Option C: Standalone Configuration

Cloud Management

Manage and monitor the Switch through the FitXpress Platform with a mobile app or through the web portal.
FitXpress App (iOS/ Android)
Download the FitXpress mobile app App Store click here
Download the FitXpress mobile app Google Play click here

EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point - QR
codehttps://qr.engenius.ai/app/fitcloud

On-Premises Management

If you want to manage the device in on-premises mode, you need an onsite management station running the FitController connected to the same Layer 2 network.
FitController
FitController is a custom-built appliance with optimized network management software installed to ease onsite deployment without manual server configurations.

Standalone Configuration

Using your computer, you can connect to the same network (subnet) as the Switch and use the web browser to access the device’s local web GUI page for configurations whenever the device is set to Standalone mode.
Option A: Cloud Management with FitXpress
Step 1: Connecting Ethernet
Connect the Ethernet cable from the EnGenius Fit Switch directly to the DHCP- enabled network and make sure the Switch can reach the Internet.EnGenius
EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point -
parts4 Step 2: Register Device
You can register the access point with the FitXpress app.

  1. Open the FitXpress mobile app and create an account.
  2. Login and go to the Devices section. Click the Add (+) button.
  3. Scan the QR code on the back of the device via the app.EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point - parts5
  4. If the camera successfully scans the QR code, the app will display the device information. You can tap “Register” to complete the registration.

Step 3: Connect to FitXpress
Once the device is powered on and ready to connect to the Internet, the PWR LED will stay Solid On, which means the device is now connected to the FitXpress platform. It will automatically download the default configuration settings from FitXpress for automated provisioning.
When the Switch is connected to the FitXpress Platform for the first time, it will automatically check the latest firmware version available. If a firmware upgrade is required, it might take 8~10 minutes to complete the process. All LED indicators will be Flashing (0.5 sec) till the process is finished.
Step 4: Manage with the FitXpress
Log in to the FitXpress app to configure detailed settings and monitor your devices. EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point -
parts7Option B: On- premises Management with FitController
Step 1: Connecting Ethernet
Connect the Ethernet cable from the EnGenius Fit Switch directly to the DHCP- enabled network, which is the same Layer-2 network as FitController.EnGenius
EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point -
parts8 Step 2: Log in to the FitController
Launch your web browser to access the login page of FitController and create an account. Enter the email address and password that you created and click Sign In.
The FitController default IP address in DHCP client mode will get an IP address (e.g. X.X.X.X:8080) from the DHCP server. If FitController cannot get an IP address from the DHCP server, the default IP address will be 192.168.1.250:8080.EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch
Access Point - parts9 Step 3: Register Device and Assign to Network

  1. Go to the system > Inventory page and click “Register Device (+)”.

  2. FitController will list all EnGenius Fit devices discovered from the same L2 network in the Pending Approval section.
    Select the device and Click “Register” to add to inventory. You can also tap “Manually” tab and register Fit device by entering Serial Number.

  3. From the Inventory page, Select the newly added device and click “Assign to Network” to add the device to your personalized network.EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point - parts10

Step 4: Pairing the Device

  1. Go to access point or switch list.
  2. Select the newly added device and click “Pairing” to allow the access point to build an encrypted connection between the device and FitController.

EnGenius EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point -
parts11 Step 5: Manage with FitController
Navigate to the left side menu to configure & manage your network and view network statistics using the FitController management interface.
Option C: Standalone Configuration
Step 1: Access to Local Web

  1. Connect the Ethernet cable from the laptop directly to the EnGenius Fit Switch.
  2. Under your web browser, enter the URL: http://EnGenius.local or http://192.168.0.239 to access the device’s user interface.
  3. Use the default login credential (ID/PWD: admin/password) to log in to the device’s local web page.

Step2: Configure and Manage the Device
After logging into the device’s local web page, navigate to the left side menu to configure and manage the Switch accordingly.EnGenius EWS2910P-FIT Fit L2
Managed 55W PoE Switch Access Point - parts12 How to Change Management Mode?
EnGenius Fit devices support versatile network management methods, but the device can only be managed under one management mode at a time – either FitXpress, FitController, or Standalone. Therefore, you need to reset the device before changing to a different management mode. Then follow Quick Start Guide instructions for the device onboarding.
Maximum data rates are based on IEEE 802.11 standards. Actual throughput and range may vary depending on distance between devices or traffic and bandwidth load in the network.
Features and specifications subject to change without notice. Trademarks and registered trademarks are the property of their respective owners. For United States of America: Copyright ©2022 EnGenius Technologies, Inc. All rights reserved.

EnGenius Technologies
1580 Scenic Ave. Costa Mesa, CA 92626
Email: partners@engeniustech.com
Website: engeniustech.com
Version:11/2022

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals