Product Information

Specifications

  • Spitzentyp Baureihe: Pico
  • Sicherheitsablage: WXMPS MS
  • Versorgungseinheit: 40 W, 12 V / AC
  • Temperature Range: 100 – 450 degrees Celsius
  • Heating Time: 3 seconds

Product Usage Instructions

User Groups

The product can be used by the following user groups:

  • Technical personnel with training
  • Electrical specialist
  • Safety specialist
  • Laypersons
  • Technical apprentices under the guidance and supervision of a trained professional

Care and Maintenance3

It is important to properly care for and maintain the product to ensure its optimal performance. Follow these guidelines:

  • Read and follow the operating instructions provided in the user manual.
  • Regularly clean the product and remove any dust or debris that may accumulate.
  • Replace any worn or damaged parts with genuine replacement parts.
  • Perform regular maintenance checks to ensure all components are in proper working order.

Temperature Performance

The product has a temperature range of 100 – 450 degrees Celsius and a heating time of 3 seconds.

Warranty

The product comes with a warranty. Please refer to the warranty documentation for more information.

Symbols

The product may feature various symbols that indicate specific instructions or warnings. Refer to the user manual for a comprehensive list of symbols and their meanings.

Technical Data

  • Spitzentyp Baureihe: Pico
  • Sicherheitsablage: WXMPS MS
  • Versorgungseinheit: 40 W, 12 V / AC

FAQs

  • Q: What is the temperature range of the product?
  • A: The temperature range of the product is 100 – 450 degrees Celsius.
  • Q: How long does it take for the product to heat up?
  • A: The product heats up in approximately 3 seconds.
  • Q: Can the product be used by laypersons?
  • A: Yes, the product can be used by laypersons. However, it is recommended to have technical training or supervision when using the product.

INFO

https://www.weller-tools.com/wxsmart

PLUGGING

Weller-WXsmart-Ultra-Tweezer-Easy-Set-fig-15

POWER

Weller-WXsmart-Ultra-Tweezer-Easy-Set-fig-3

WHAT IS IN THE BOX

WXMPS MS WXUPS MS

Weller-WXsmart-Ultra-Tweezer-Easy-Set-fig-4

WXMTS WXUTS

Weller-WXsmart-Ultra-Tweezer-Easy-Set-fig-5

  • Repairs must always be referred to a Weller-trained specialist. Use original replacement parts only.

WARNING   Risk of burns

Only replace the soldering tips when they are cold. The soldering tool must be left switched off in the safety rest for at least 3 minutes until the soldering tip has cooled down. The LED status indicator must be at „OFF

Temperature performance

The soldering tool has an internal usage sensor which can be used to set an automatic switch-off function (Stand-by). The settings can be found in the station’s operating instruc-tions.

Warranty

Claims by the buyer for physical defects are time-barred after a period of one year from delivery to the buyer. This does not apply to claims by the buyer for indemnification in accordance with §§ 478, 479 BGB (German Federal Law Gazette). We shall only be liable for claims arising from a warranty furnished by us if the quality or durability warranty has been furnished by us in writing and using the term „Warranty“.
The warranty shall be void if damage is due to improper use and if the device has been tampered with by unauthorized persons. For more information please visit www.weller-tools.com.

Symbols

  • Caution!
  • Warning! Risk of burns!
  • Read the operating instructions!
  • Before performing work of any kind on the unit, always disconnect the power plug from the socket.
  • ESD-compatible design and ESD-compatible workstation
  • CE mark of conformity
  • British Conformity Mark
  • Disposal Do not dispose of electric tools together with household waste material! In observance of European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation in accordance with national law, electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.
  • Disposal – UK Do not dispose of electric tools together with household waste material! In observance of British Directive 2013 No. 3113 on waste electrical and electronic equipment and its implementation in accordance with national law, electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility.

Technical Data

Pico Ultra

Soldering iron| WXMPS MS| WXUPS MS
Temperature range °C

Temperature range °F

| 100 – 450

200 – 850

| 100 – 450

200 – 850

Power consumption| 40 W| 150 W
Mains supply voltage| 12 V / AC| 24 V / AC
Heat-up time

(50°C to 350°C) (120°F to 660°F)

| 3 s| 7 s
Tip type series| RTMS MS / RTPS MS| RTUS MS
Safety rest| WSR 208| WSR 200
Supply unit| WX Smart Station
Micro/Pico Ultra

Desoldering iron| WXMTS| WXUTS
Temperature range °C

Temperature range °F

| 100 – 450

200 – 850

| 100 – 450

200 – 850

Power consumption| 80 W| 150 W
Mains supply voltage| 12 V / AC| 24 V / AC
Heat-up time

(50°C to 350°C) (120°F to 660°F)

| 5 s| 10 s
Tip type series| RTWMS / RTWPS| RTWUS
Safety rest| WSR 210| WSR 210
Supply unit| WX Smart Station

Subject to technical alterations and amendments.

CONTACT

www.weller-tools.com/registration

GERMANY

  • Weller Tools GmbH
  • Carl-Benz-Straße 2 74354 Besigheim
  • Tel: +49 (0)7143 580-0 Fax: +49 (0)7143 580-108
  • www.weller-tools.com

USA

CHINA

  • Apex Tool Group
  • Room 302A,
  • NO 177 Bibo Road
  • Shanghai, 201202
  • Tel: +86 (21) 60880288
  • Fax: +86 (21) 60880289

GREAT BRITAIN

  • For Weller Tools GmbH
  • Apex Tool Group UK Ltd
  • Registered in England,
  • Company Number 14127816
  • Registered Office:
  • 20 Farringdon Street, 8th Floor
  • London, EC4A 4AB, United Kingdom

www.weller-tools.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals