HPC TOR-PENTA13MLFPK-FLEX Penta Burner Owner’s Manual
- June 15, 2024
- HPC
Table of Contents
HPC TOR-PENTA13MLFPK-FLEX Penta Burner Owner's Manual
NOTES:
-
PROPER VENTING
• ENCLOSURES: – For Fire Pit Inserts up to 65K BTU: Required 2 vents, 18 sq.in. each on opposing sides.
• BOWLS (Copper, concrete or metal) – Bowl to be raised above mounting surface minimum of 3/4″ gap; Bowl to have a minimum of 6″ diameter hole in bottom -
GAS SUPPLY
• Natural Gas: Supply Pressure: Minimum: 3.5″ W.C.; Maximum: 7.0″ W.C.
• LP Gas: Supply Pressure: Minimum: 8.0″ W.C.; Maximum 11.0″ W.C.
IMPORTANT: Ensure any flex line that may be used from the permanent main fuel supply to the product is rated to the stated max btu of the product and certified to ANSI Z21.75*CSA 6.27. -
MODIFCATION OF PRODUCT WILL VOID ANY CERTIFICATION AND WARRANTY.
-
FOLLOW ALL MANUFACTURER INSTALLATION INSTRUCTIONS AND LOCAL CODES.
-
ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER’S SPECIFICATIONS AS OF THE REVISION DATE.
-
DO NOT SCALE DRAWING.
-
THESE DRAWINGS ARE FOR SIZING AND PLANNING PURPOSES. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT. THE MANUFACTURER’S RESPONSIBLE FOR THE ACCURACY OF THE DRAWING.
-
CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info
MATCH LIT FIRE PIT INSERT – WITH FLEX LINE BOWL ROUND PAN – MLFPK
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>