HAISITO C240 Dual LiPo Balance Charger Instruction Manual
- June 15, 2024
- HAISITO
Table of Contents
HAISITO C240 Dual LiPo Balance Charger
Note:
Haisito is the direct manufacturer of this product. If you have any problems
in the use process, please do not hesitate to contact us, and we will solve
your problems perfectly.
C150/C240 Balance Charger
Key Features:
- Compatible with LiPo/Li-ion/LiFe/LiHv/NiMH/NiCd, and Pb batteries
- It has Charge, Discharge, Balance Charge, Fast Charge, Storage Charge Modes
- Load Memory Function, NiCd/NiMH Cycle
WARNING
- Please select the correct battery type when charging. If you do not know the battery type, please consult your battery supplier. The wrong battery type may cause battery damage, fire and explosion.
- Please set the correct current to charge the battery. Excessive charging current may lead to battery damage, fire, and explosion.
Please refer to the following table for the charging current settings for different battery capacities.
Introduction
Thank you for purchasing the Cl 50/C240 Balance Charger. This product is a rapid charger with a high-performance microprocessor and operating software. Please be sure to read this entire operating manual completely before you use this product for the first time,as it covers a wide range of information on operation and safety.
- AC Input Voltage Range: 100-240V
- Input Voltage Range: DC 11-18V
- Display: 1602 LCD Screen
- Controls: Four Buttons
- Charge Current Range: 0. 1.10A
- Discharge Current Range: 0.1-2A
- Dimension: 145 x 105x64mm
Please connect the chargers in turn
- Connect AC cable
- Correctly connect the positive and negative electrode
- Correctly connect the battery and the octopus multicharging harness
- Correctly connect the balance board with the battery
- Correctly connect the balance ports correctly
- Charge Power Limited:
- (C150) AC 150W, DC 150W
- (C240) AC CH+CH2=150W, DC 120W*2
- Discharge Power Limited: Max. 1 OW
- Battery Types/Cells: LiPo/Li-ion/LiFe/LiHv 1-6cells
- NiMH/NiCd 1-15cells
- Pb(Lead Acid) 2-20V, 1-10cells
- Weight: 460g
- Press the “BATT TYPE/STOP button, you can select or quit a program and back to the main menu.
- Press the “ENTER/START’button, you can enter the submenu, make the parameter numbers blink, and save the profile, press and hold the “ENTER/START button for 2 seconds to start the process.
- Press the “DEC” or ” INC”, and you can select a program or a submenu, set the parameter, or see the battery charging status
Following is an example of charging NiMH battery, for more operating instructions please refer to Page 17 to Page 32, or Go to our website www.ht- rc.com.
Key Features
-
Optimize Operating Software
When charging or discharging. CI 50/C240 has an “AUTO” function that can automatically identify the cell count of the battery. -
Wide Battery Type Compatibility
- C150/C240 is compatible with Lipo/Li-ion/LiFe/LiHv, NiMH/NiCd, and Pb battery
- Please select the correct one before charging
-
Balance Individual Cells on Discharge
C150/C240 can also monitor and balance individual cells of the battery pack during discharging. -
Fast charge and Storage charge for Li-ion/Li-Polymer batteries
Fast charge mode reduces the charging time of the battery than charge mode, Storag charge mode controls the final voltage of the battery, suitable for long-term storage. -
Load Memory Function
For your convenience, C150/C240 can store 20 memories for different types of batteries You can select the data and the process can be executed directly without setting. -
NiCd/NiMH cycle
Continually perform I to 5 cycles of charge/discharge NiCd/NiMH batteries.
Extra Function
1>Meter Lixx Battery Status; 2>Meter Lixx Battery Lithium Battery;4>Digital Power;5>Smart Battery Charge.
Batteries information and charge current range
Operating Instructions
Main Menu
When the C150/C240 Charger first powers up, the LCD screen will display the
brand and official website for 2 seconds. To select the desired program,
press”BATT TYPE/STOP, and cycle through the options.
Lithium Batteries Program
Balance Charge Mode
When C150/C240 Charger first powers up, the Main Menu will display “PROGRAM
Lithium BATT SELECT’
- Please make sure to select the correct type of Lithium battery.
- Please make sure the charge rate doesn’t exceed the maximum value.
- Use this formula to find the charge rate: Charge rates≤Capacity/1000.
- The operating steps of Charge mode, Fast Charge mode Storage Charge mode, and Discharge mode are the same with Balance Charge mode.
- Please make sure the discharge rate doesn’t exceed 2A.
NiMH/NiCd and PB Batteries Program-Charge Mode
- Please make sure to select the correct type of battery.
- Please make sure the charge rate doesn’t exceed the maximum value.
- Use this formula to find the charge rate: Charge rates≤Capacity/1000.
- The operating steps of the Discharge mode and Cycle mode are the same as the Charge mode.
- Please make sure the discharge rate doesn’t exceed 2A.
- In Cycle mode, D⇒C means discharge to charge, C⇒D means a charge to Discharge
User Settings
-
Key Beep and Buzzer VOL
In this submenu, you can turn on/off the key beep and set the volume of the buzzer. -
Completion Ring Beep
In this submenu, you can set the completion ring time from 1 to 5 minutes. -
Cycle Waste Time
In this submenu, you can set the waste time between charge and discharge in NiMH/NiCd cycle mode, ranging from 1-60Min. -
Low Input VOLT Cut-Off
In this submenu, you can set the cutoff input voltage of the power supply of the charger to protect it The charger will cut off working when the input voltage is lower than the setting value. Range from 10-18V. -
Ext. Temp Cut-Off
In this submenu, you can set the cutoff external temperature to protect your battery. The charger will cut off working when the external temperature is higher than the setting value. Range from 30-90 C -
Capacity Cut-Off
- In this submenu, you can set the cutoff capacity to protect your battery.
- The charger will cut off working when the capacity is more than the setting value. Range from 100-60000mAh.
-
Safety Timer
- In this submenu, you can set a safety time to protect your charger and battery.
- The charger will cut off working when reaches the setting value. On/Off is optional, range from 10-720 minutes.
-
Charge Power Limit
In this submenu, you can set the charge power limit to meet your power supply requirement. Range from 0-150W. -
LiXX Balance Control
In this submenu, you can set the balance control of LiPo/Li-ion/LiFe/LiHV to meet your demand. Stand/Fast/Accurate is optional. The default is Stand.- Fast: Balance speed fastest, less accurate.
- Accurate: Balance speed lowest, more accurate.
- Standard: Balance speed and accurateness between Fast and Accurate.
-
Termination Voltage Control
In this submenu, you can set the termination voltage value per cell of your batteries according to your request.- LiPo Charge WC: Range from 4150-4250 mV/s, default is 4200 rnV/s
- LiPo Discharge TVC: Range from 3000-3850 mV/s, default is 3200 mV/s
- LiHV Charge WC: Range from 4300-4400 rnV/s, default is 4350 mV/s
- LiHV Discharge TVC: Range from 3000-3750 mV/s, default is 3300 mV/s
- Li-ion Charge TVC: Range from 3750-4200 mV/s, default is 4100 mV/s
- Li-ion Discharge TVC: Range from 3000-3750 mV/s, default is 3100 mV/s
- LiFe Charge TVC: Range from 3800-3800 mV/s, default is 3600 mV/s
- LiFe Discharge TVC: Range from 2500-8800 mV/s, default is 2500 mV/s
- NiMH Sensitivity D. Peak: Range from 4-20mV
- NiMH Discharge TVC: Range from 500-1000mV/s, default is 800mV/s
- NiCd Sensitivity D. Peak: Range from 4-20mV
- NiCd Discharge TVC: Range from 500-1000mV/s, default is 1000mV/s
- Pb Charge TVC: Range from 1500-2500 mV/s, default is 2400 mV/s
- Pb Discharge TVC: Range from 1000-1500 mV/s, default is 1500 mV/s
- Reset Factory Default Setting
In this submenu, you can restore the factory setting
The operating steps of Key Beep and Buzzer VOL, Completion Ring Beep, Cycle Waste Time, Low Input VOLT Cut-Off, Ext. Temp Cut-Off, Capacity Cut-Off, Safety Timer, Charge Power Limit, LiXX Balance Control, Reset Factory Default Setting.
The operating steps of Termination Voltage Control
Extra Function Program
-
Meter Lixx Battery Status
This function lets you know your battery status -
Meter Lixx Battery IA
This function lets you know your battery IR -
Balancer Lithium Battery
With this function, the charger can Balance Individual Cells of your battery. -
Digital Power
- With this function the charger can be used as a voltage-adjustable power supply, voltage range from 5-27 V, and power is BOW.
- The operating steps are the same with 3> Balancer Lithium Battery.
-
Smart Battery Charge
- With this function, the charger can charge smart batteries
- The operating steps are the same with 3> Balancer Lithium Battery.
Load Memory Program
20 memories record the work of the charger, LS=latest record.
Error Messages
CAUTION AND NOTES
-
This charger is ONLY suitable for charging rechargeable LiPo, Li-ion, LiFe, LiHV NiCd, NiMH, Smart, and Pb batteries. Do not attempt to charge dry cells. Charge other types of batteries may cause fire or explosion.
-
Set up the InputPower Limit/Low Input VOLT Cutoff correctly in the IJSER SEATING
-
Pay attention to the charger during use. Do not leave the charger unattended.
-
Never charge the dead or damaged batteries.
-
Do not attempt to charge a battery pack containing different types of batteries.
-
Do not use too short or damaged cables.
-
Do not use the charger close to a flammable object. IJse only in well-ventilated areas.
-
Only charge the rechargeable batteries that meet the product specifications of this charger.
-
Do not allow water, moisture, or foreign objects into the charger.
-
Do not use it in humid locations. Do not operate with wet hands.
-
Do not attempt to disassemble the charger.
-
Do not use the charger on fleecy materials, such as carpets, blankets, beds, and cushions.
-
Do not block the cooling fan and the air inlet.
-
Strongly recommend balancing Lithium packs. An unbalanced pack may be damaged during discharging.
-
The general default charging current is IC. Read the manual of the battery and setup a suitable current to charge the battery Higher charge/discharge current will damage the battery, and even cause a fire.
-
NEVER store LiPo batteries in any location that exceeds 800 F (e.g. in a car, garage, or in the sun)
-
NEVER let the battery’s positive and negative leads touch. This can cause the battery to short circuit and lead to a FIRE. If for any reason you need to cut the terminal wires it will be necessary to cut each wire SEPARATELY, to ensure the wires do NOT touch each other.
-
NEVER charge a swollen or ballooned battery (even if swollen upon purchase). Continue to charge a battery that has begun to swell will result in a fire.
Follow these steps:- STOP the charging process
- Disconnect the battery from the device immediately.
- Place it in an open non-flammable area.
- Watch it for approx. 30 minutes from a safe distance.
- Follow the proper procedure to dispose of the battery
-
ALWAYS store LiPo batteries in cool, dry places between 40-800 F.
-
Avoid Over-Discharging LiPo Batteries
-
The internal battery damage caused by over-discharging will not always be visible. However, this can potentially lead to a FIRE when attempting to recharge it at later times.
-
Allow the battery to cool down before charging,
-
DO NOT charge multiple battery packs in series. Charge each battery pack individually. Failure to do so may result in incorrect battery recognition and charging functions. Overcharging may occur and possibly result in FIRE.
-
When selecting the cell count or voltage for charging purposes, select the cell count and voltage as it appears on the LiPo battery label. Selecting a cell count or voltage other than the one printed on the label will cause improper charging rates that can lead to fire.
Example: The label/ on a 2-CeII battery pack in series will read – – “11.1V” -
You must select 2-Cell for charging.
Example: The label on a a-Cell battery pack in series will read – “11.1V” -
You must select a cell for charging.
-
You must check the pack voltage before charging. Do not attempt to charge any pack if the open voltage per cell is less than 3.3M For example:
-
Do not charge a 2-cell pack if below 6.6V
-
Do not charge a 3-cell pack if below 9.9V
WARNING
- Please select the correct battery type when charging. If you do not know the battery type, please consult your battery supplier. The wrong battery type may cause battery damage, fire, and explosion.
- Please set the correct current to charge the battery. Excessive charging current may lead to battery damage, fire, and explosion.
Please refer to the following table for the charging current settings for different battery capacities.
MADE IN CHINA.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>