eurofred ASYG12KGTB Air Conditioner Instruction Manual
- June 15, 2024
- EUROFRED
Table of Contents
- eurofred ASYG12KGTB Air Conditioner
- Product Information
- SAFETY PRECAUTIONS
- PREPARATION
- NAME OF PARTS
- Inserting batteries
- BASIC OPERATIONS
- AIRFLOW SETTINGS
- TIMER OPERATIONS
- ENERGY SAVING OPERATIONS
- OTHER OPERATIONS
- SETTINGS ON INSTALLATION
- CLEANING AND CARE
- GENERAL INFORMATION
- OPTIONAL PARTS
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
eurofred ASYG12KGTB Air Conditioner
Product Information
- Model: [Model Name]
- Language Options: English, Deutsch, Italiano
Specifications
- Product Type: Air Conditioner (Wall Mounted type)
- Part Number: 9387602050-02
Safety Precautions
To prevent personal injury or property damage, please follow these safety
precautions:
- WARNING: This mark warns of death or serious injury.
- CAUTION: This mark warns of injury or damage to property.
- PROHIBITED: This mark denotes an action that is prohibited.
- COMPULSORY: This mark denotes an action that is compulsory.
Symbols
The following symbols may be displayed on the indoor or outdoor unit:
- WARNING: This symbol shows that the product uses a flammable refrigerant. There is a risk of fire if the refrigerant is leaked and exposed to an external ignition source.
- CAUTION: This symbol shows that the operation manual should be read carefully.
- CAUTION: This symbol shows that a service personnel should handle the equipment with reference to the installation manual.
- CAUTION: This symbol shows that information is available such as the operation manual or installation manual.
Preparation
Please follow these steps to prepare the air conditioner for use:
- WARNING: Ensure that the air conditioner is installed in a suitable location with proper room area and refrigerant charge. Refer to the specifications for the correct values.
- CAUTION: Do not place any household belongings under the air conditioner to prevent damage or malfunction caused by dripping condensation.
- Check that the following accessories are included with the indoor unit:
- Remote controller
- Remote controller holder
- Self-tapping screws
- Batteries
- Air cleaning filters
- Filter holders
- Install the remote controller holder using the provided screws:
- Insert the remote controller holder into the designated slot on the indoor unit.
- Secure the holder in place using the provided screws.
FAQ
-
Q: What should I do if I smell gas?
A: If you smell gas, immediately turn off the air conditioner and any sources of ignition. Open windows and doors to ventilate the area. Do not operate any electrical switches or appliances. Contact a professional technician or your gas supplier for assistance. -
Q: How often should I clean the air cleaning filters?
A: It is recommended to clean the air cleaning filters every month. Refer to the user manual for detailed instructions on how to clean and maintain the filters. -
Q: Can I install the air conditioner myself?
A: Installation of the air conditioner should be done by a qualified professional. Improper installation may result in inefficient operation or damage to the unit.
MODEL
Please write down the model name. (Refer to the rating label.)
SAFETY PRECAUTIONS
-
To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.
-
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:
-
WARNING
This mark warns of death or serious injury. -
CAUTION
This mark warns of injury or damage to property. -
This mark denotes an action that is PROHIBITED.
-
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this product uses a flammable refrigerant. If the
refrigerant is leaked and exposed to an external ignition source, there is a
risk of fire.
-
CAUTION
This symbol shows that the operation manual should be read carefully. -
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual. -
CAUTION
This symbol shows that information is available such as the operation manual or installation manual.
WARNING
The appliance shall be installed, operated and stored in a room with a floor area larger than X m².
Amount of refrigerant charge M (kg)| Minimum room area X (m
2 )
---|---
M ≤ 1.22| –
1.22 < M ≤ 1.23| 1.45
1.23 < M ≤ 1.50| 2.15
1.50 < M ≤ 1.75| 2.92
1.75 < M ≤ 2.0| 3.82
2.0 < M ≤ 2.5| 5.96
2.5 < M ≤ 3.0| 8.59
3.0 < M ≤ 3.5| 11.68
3.5 < M ≤ 4.0| 15.26
-
This product contains no user-serviceable parts. Always consult authorized service personnel for repairing, installation, and relocation of this product. Improper installation or handling will cause leakage, electric shock, or fire.
-
In the event of a malfunction such as burning smell, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized service personnel.
-
Take care not to damage the power supply cable. If it is damaged, it should be replaced only by authorized service personnel in order to avoid a hazard.
-
In the event of refrigerant leakage, be sure to keep away from fire or any flammables, and consult authorized service personnel.
-
In the event of a thunder storm or any prior sign
of a lightning strike, turn off the air conditioner via the remote controller, and refrain from touching the product or the power source to prevent any electrical hazards. -
This product shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
-
This product shall be stored in a well-ventilated area.
-
Be aware that refrigerants may not contain an odour. This product shall be stored so as to prevent mechanical damage from occurring.
-
Disposing of the product shall be done properly, in compliance with national or regional regulations.
-
During transportation or relocation of the indoor unit, pipes shall be covered with the wall hook bracket for protection.
-
Do not move this product by holding the indoor unit pipes.(The stress applied to the pipe joints may cause the flammable gas to leak during operation).
WARNING
- This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of this product by a person responsible for their safety. Children should be supervised to ensure that they do not play with this product.
- Dispose of the packing materials safely. Tear and dispose of the plastic packing bags so that children cannot play with them. There is danger of suffocation if children play with the original plastic bags.
- Do not install the unit in area filled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen.
- Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker.
- Do not use flammable gases near this product.
- Do not expose yourself directly to the cooling airflow for many hours.
- Do not insert your fingers or any other objects into outlet port or inlet port.
- Do not operate with wet hands.
- Do not use means to accelerate the defrosting process or to clean this product, other than those recommended by the manufacturer.
- Do not pierce or burn.
CAUTION
- Provide occasional ventilation during use.
- Always operate this product with air filters installed.
- Ensure that any electronic equipment is at least 1 m (40 in) away from this product.
- Disconnect all the power supply when not using this product for extended periods.
- After a long period of use, ensure to get the mounting of the indoor unit checked to prevent this product from falling down.
- The airflow direction and the room temperature should be carefully considered when you use this product in a room with infants, children, elderly or sick persons.
- Keep the surroundings of the outdoor unit clean and tidy, and do not place items around it. Any objects blocking or entering from the outlet ports may cause product malfunction.
- Do not direct the airflow at fireplaces or heating apparatus.
- Do not block or cover the intake grille and the outlet port.
- Do not apply any heavy pressure to radiator fins.
- Do not climb on, place objects on, or hang objects from this product.
- Do not place any other electrical products or household belongings under this product. Dripping condensation from this product might get them wet, and may cause damage or malfunction of your property.
- Do not expose this product directly to water.
- Do not use this product for preservation of food, plants, animals, precision equipment, art work, or other objects. This may cause quality deterioration of those items.
- Do not expose animals or plants to the direct airflow.
- Do not drink the drainage from the air conditioner.
- Do not pull the power supply cable.
CAUTION
- Do not touch the aluminum fins of heat exchanger built-in this product to avoid personal injury when you maintain the unit.
- Do not stand on unstable steps when operating or cleaning this product. It may overturn and can cause injury.
This product contains fluorinated greenhouse gases.
PREPARATION
WARNING
Take care to prevent infants and young children from accidentally
swallowing the batteries.
CAUTION
- If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and consult your physician.
- Exhausted batteries must be removed immediately, and be disposed according to the local laws and regulations of your region.
- Do not attempt to recharge dry batteries.
- Do not use dry batteries that has been recharged.
Indoor unit accessories
Remote controller holder installation
NAME OF PARTS
CAUTION
- For appropriate signal transmission between the remote controller and the indoor unit, keep the signal receiver away from the following items:
- Direct sunlight or other strong lights
- Flat-panel television screen
- In rooms with instantaneous fluorescent lights, such as inverter type ones, the signal may not be transmitted properly. In such a case, consult the store of purchase.
Indoor unit
- Before starting operation, make sure that the intake grille is closed completely. Incomplete closing may affect the proper function or performance of the product.
- Indicator lamps light in the following conditions.
Remote controller
- When you use the optional remote controller, the appearance and the operation procedure may differ.
- For details, please refer to the operation manual of each remote controller.
- : The setting must be done while the setting screen is displayed for each function.
- : The button is controllable only when the air conditioner is operating.
Signal transmitter
Aim at the signal receiver of the indoor unit properly.
- Operating range is approximately 7 m.
- will appear when the signal is transmitted.
- The indoor unit will emit a beep when it receive the signal properly. If there is no beep, press the button again.
Remote controller display
In this section, all the possible indicators are displayed for description. In
actual operation, the display is linked with the button operation, and only
shows the necessary indicators for each setting.
CAUTION
- To prevent malfunction or damage of the remote controller:
- Place remote controller at where will not be exposed to direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for an extended period.
- Obstacles such as a curtain or wall between the remote controller and the indoor unit may affect the appropriate signal transmission.
- Do not apply strong shocks to the remote controller.
- Do not pour water on the remote controller.
Inserting batteries
Battery type: R03/LR03/AAA x 2
-
Pull the cover in the direction of the arrow and open it until it is trapped.
-
Remove the cover.
-
Turn the remote controller over and push the back side of the cover and remove the claws by curving the cover.
-
Pull in the direction of the arrow while curving the cover.
-
Put batteries as shown in the figure above.
-
Press “RESET” as shown in the figure above.
Use the tip of a ballpoint pen or other small object. -
Press to start setting day of the week and clock.
-
Press SELECT ) to set day of the week (Monday to Sunday).
-
Press NEXT to continue.
-
Press SELECT ) to set the clock.
-
Press the buttons to change the clock by a minute.
-
Press and hold the buttons to change the clock by 10 minutes.
-
To switch the time indicator (12-hour ⇔ 24-hour), press
-
Press SEND to complete the setting.
Be close to the indoor unit. If you press the button from a distance, settings may not be properly sent. -
Install and close the cover.
NOTES:- Use specified type of batteries only.
- Do not mix different types or new and used batteries together.
- Batteries can be used about 1 year in ordinary use.
- If the remote control range noticeably shortens, replace the batteries, and press as shown in the figure above.
BASIC OPERATIONS
steps to start operation
-
Press to start or stop the operation.
-
Press MODE to select the operation mode.
The operation mode changes as follows. -
Press to set the desired temperature.
The temperature changes by 0.5 °C increments.
Temperature setting range
Auto/Cooling/Dry 18.0 – 30.0 °C
Heating 16.0 – 30.0 °C
NOTES:
- In the Cooling or Dry mode, set the temperature lower than the current room temperature.
- In the Heating mode,
- set the temperature higher than the current room temperature.
- at the beginning of the operation, the indoor unit fan rotates at very low speed for 3-5 minutes.
- the Automatic defrosting operation overrides the Heating operation when necessary.
- In the Fan mode, temperature control is not available.
Temperature unit switching
-
Press until only the clock is displayed.
-
Press and hold for more than 5 seconds.
The current temperature unit will be displayed. (Factory setting: °C) -
Press to switch the temperature unit. (°C ⇔ °F)
-
Press to finish the setting.
If you do not press the button for 30 seconds, the displayed temperature unit will be set.
AIRFLOW SETTINGS
Fan speed setting
-
Press **** to control the fan speed.
The fan speed changes as follows. -
When is selected, the fan speed depends on the operating
To increase the air cleaning effect, set the fan speed to High.
Airflow direction setting
For details of the airflow ranges, refer to “Airflow direction range”.
Vertical airflow direction setting
- Press to adjust the vertical airflow direction.
Horizontal airflow direction setting
CAUTION
- Before you adjust the horizontal airflow direction, make sure that the vertical airflow direction louver has been stopped completely.
- Adjust two knobs by hand.
Swing operation setting
- Press to start/stop the Swing operation.
NOTES: The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped.
Airflow direction range
Vertical airflow direction
The Swing operation range depends on the airflow direction set before the
Swing operation.
NOTES:
- Do not adjust the airflow direction louvers by hand.
- In the Auto or Heating mode, the airflow direction stay position 1 for a while from the start of the operation.
- In the Cooling or Dry mode, position 1-3 is recommended to prevent condensation drips damaging your property. If position 4-6 keeps for 30 minutes or more in these modes, the airflow direction changes to position 3 automatically.
- When using the mobile app (optional wireless LAN control is necessary), the vertical airflow can be selected from 4 positions.
TIMER OPERATIONS
NOTES: When indicator on the indoor unit blinks, set the clock and timer again. This blinking shows that the internal clock go wrong due to an interruption of the power supply. (Refer to page 11.)
Timer setting procedure] Before setting the timer, please adjust the clock. (Refer to “remote controller preparation”).
-
Press on the remote controller display will blink.
-
Press SELECT to choose timer operation.
The timer operation will change as follows: -
Press NEXT
-
Set each timer operation.
For details, refer to the following instructions of each timer setting. -
Press SEND to complete the timer setting.
Be close to the indoor unit.- To cancel the timer setting during the procedure, press again.
Weekly timer
Setting details
-
Select Weekly timer in step 2 of “Timer setting procedure”.
-
Press SELECT to select the program number and the day of the week.
Selected program number (1~4) and the day of the week will blink. -
Press NEXT
-
Press SELECT to choose the timer operation.
-
Press NEXT
When you chose “Without a timer” in step 4, the setting display will
return to step 1. -
Press SELECT to set on time or off time.
-
Press NEXT
When you chose “Off timer” in step 4, the setting display will return to step -
Press SELECT to set the temperature
Temperature setting range** Auto, Cooling, or Dry mode:**|- 18.0-30.0 °C
- Even if you set to 10.0, 16.0-17.5 conditioner will run at 18.0 °C.
| °C, the| air
---|---|---|---
Heating mode:| 10.0 or 16.0-30.0 °C
-
Press NEXT
The setting display will return to step 1. -
Press SEND to complete the setting.
Be close to the indoor unit.
NOTES: indicator on the indoor unit will not turn on even if the setting is complete
- If you want to return the previous step, press BACK
- To check the schedule, use SELECT to browse the Weekly timer settings in step 1.
- To finish checking, press
- To deactivate the Weekly timer, press while is shown on the remote controller display.
- The indicator will disappear
NOTES:
- The operation modes will be the same as the mode at the last time operation was stopped, so Cooling → Heating → Cooling → Heating type of operations cannot be set automatically.
- If you set the On timer and Off timer on the same time, the On timer will work.
- If two On timers are set on the same time, the air conditioner will run in the order of the program number.
- You cannot the Weekly timer and the other timers simultaneously. If you use the On/Off timer, the Program timer, or the Sleep timer while the Weekly timer is activated, the
- Weekly timer will be deactivated.
- In such a case, activate the Weekly timer after the other timer finishes.
- If the wired remote controller (optional) is connected, this function is restricted.
Examples of Weekly timer
On timer or Off timer
-
Select On timer or Off timer in step 2 of “Timer setting procedure”.
-
Press () to set on time or off time.
Pressing the button: The time will change by +5/-5 minutes. Pressing and holding the button: The time will change by +10/-10 minutes.- To deactivate the On/Off timer, press while shown on the remote controller display. The indicator will disappear.
Program timer
- Set On timer and Off timer. (Refer to “6.2. On timer or Off timer”).
- Select Program timer in step 2 of “Timer setting procedure”.
The timer whose setting time is closer to the current time works first. The order of the timer operation is displayed as follows:
NOTES: You can set the Program timer only within a span of 24 hours.
Sleep timer
- Select Sleep timer in step 2 of “Timer setting procedure”.
- Press SELECT to set the time until the operation stops.
- Each time you press the button, the time changes as follows:
- To deactivate the Sleep timer, press WHILE on the remote controller display. The indicator will disappear.
During the Sleep timer operation, the setting temperature changes as the following figure.
After the set time has elapsed, the air conditioner operation turns off.
ENERGY SAVING OPERATIONS
Economy operation
- It saves more electricity than other operation modes by changing the set temperature to a moderate setting.
- Press to activate/deactivate the Economy operation.
- indicator on the indoor unit will turn on.
Operation mode | Room temperature |
---|---|
Cooling/Dry | Few degrees higher than the set temperature |
Heating | Few degrees lower than the set temperature |
NOTES:
- In the Cooling, Heating, or Dry mode, the maximum output of this operation is approximately 70 % of usual operation.
- This operation cannot be performed during the temperature monitoring by the Auto mode.
Occupancy sensor for energy saving
- WARNING
- Do not use this function when there are only infants, children, elderly, or sick persons in the room.
- CAUTION
- Do not use this function in server rooms or other places where there is no one in the room.
- Do not place large objects near the occupancy sensor. Also keep heating units outside the sensor’s detection area.
When no one is in the room, the air conditioner operates moderately to prevent waste of electricity. (This function is activated at the time of purchase.)
To change the setting, press
While the Energy Saving program is activated, on the remote controller
display will turn on.
NOTES:
- The following operations will override the Energy Saving program.
- Sleep timer operation
- 10 ˚C Heat operation
- The Energy Saving program may not work when the room temperature is very different from the set temperature, such as when immediately after starting the operation.
Details on Energy Saving program
- Occupancy sensor on the indoor unit detects movement of people.
- If there is no one in the room for approximately 20 minutes, the temperature will be adjusted moderately.
- When someone comes back into the room, the air conditioner revert to the original settings.
Operation mode | Room temperature (When there is no one there) |
---|---|
Cooling/Dry | Higher than the set temperature (Max. +2˚C) |
Heating | Lower than the set temperature (Max. -4˚C) |
Auto | Depending on the operating mode (Cooling/ Heating/ Dry). |
Detection range of Occupancy sensor
NOTES: Since Occupancy sensor detects infrared light given out by
people, the detection may be incorrect in the following situations.
Situations in which the sensor may detect no one in the room, even when
there is someone there:
-
When the room temperature is high and the difference with people’s body temperature is small. (Such as when the temperature is 30˚C or higher in summer.)
-
When someone in the room do not move for a long time.
-
When someone is hidden behind a sofa, other furniture, glass, or in similar situations.
-
When someone is wearing extremely thick clothing and turn their backs on the sensor.
Situations in which the sensor may detect people in the room, even when there is no one there
- When there is a dog or a cat moving around in the room.
- When wind is moving curtains or plants.
- When heating units, humidifiers, or electric appliances such as oscillating electric fans are operating.
Fan control for energy saving
- In the Cooling operation, when the room temperature reaches the set temperature, the indoor unit fan rotates intermittently to save power. (This function is activated at the time of purchase.)
- To change the setting, use the following steps;
-
Press until only the clock is displayed on the remote controller display.
-
Press and hold for more than 5 seconds.
The current Fan Control status is displayed. -
Press to switch between activated ON or deactivated OFF.
-
Press to send the setting to the indoor unit.
The display will return to the original screen.
NOTES: If you do not press any buttons for 30 seconds after is displayed, will turn off. In this case, repeat the setting from step 2.
OTHER OPERATIONS
Powerful operation
In the Powerful operation, the air conditioner will operate at maximum power
and strong airflow to cool down or warm up the room quickly.
NOTES: In multi connection, this function cannot be used.
- Press to activate/deactivate the Powerful operation.
- When activated, the indoor unit will emit 2 short beeps.
- When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned off automatically in the following situations:
- The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling, Dry, or Heating mode.
- 20 minutes after the Powerful operation has started.
NOTES:
- The airflow direction and the fan speed are controlled automatically. The Powerful operation cannot be performed simultaneously with Economy operation.
- The Powerful operation overrides the following operations. If the following operations are set, they will start after the Powerful operation finishes.
- Outdoor Unit Low Noise operation
- Energy Saving program
- If the wired remote controller (optional) is connected, this function is restricted.
Outdoor Unit Low Noise operation
The Outdoor Unit Low Noise operation lowers noise from the outdoor unit.
During this operation, the rotation number of the compressor decreases and the
outdoor unit fan rotates slowly.
NOTES: In multi connection, this function cannot be used.
- Press to activate/deactivate the Outdoor Unit Low Noise operation.
- While the Outdoor Unit Low Noise operation is activated, on the remote controller is displayed.
- The setting is preserved even if the air conditioner is turned off.
NOTES:
- This operation cannot be performed simultaneously with the Fan mode, Dry mode, and Powerful operation.
- If the wired remote controller (optional) is connected, this function is restricted.
10 °C Heat operation
10 °C Heat operation maintains the room temperature at 10 °C so as to
prevent the room temperature to drop too low.
- Press to activate the 10 °C Heat operation. The indoor unit will emit 1 short beep and indicator on the indoor unit will turn on.
- Press to turn off the air conditioner.
- indicator will turn off.
NOTES:
- During the 10 °C Heat operation, only is valid.
- When the room temperature is warm enough, this operation will not perform.
- If the wired remote controller (optional) is connected, this function is restricted.
SETTINGS ON INSTALLATION
Remote controller custom code setting
- By setting custom code of indoor unit and remote controller, you can specify the air conditioner which the remote controller controls.
- When two or more air conditioners are in the room and you wish to operate them separately, set the custom code (4 selections possible).
NOTES: If custom codes is different between the indoor unit and the remote controller, the indoor unit cannot receive a signal from the remote controller.
How to set the remote controller custom code
-
Press until only the clock is displayed on the remote controller display.
-
Press and hold MODE for more than 5 seconds.
The current custom code will be displayed (initially set to A). -
Press to change the custom code between .
Match the custom code on the display to the air conditioner custom code. -
Press MODE again.
The custom code will be set.
The display will return to the clock display.
- To change the air conditioner custom code, contact an authorized service personnel (initially set to A).
- If you do not press any buttons for 30 seconds after the custom code is displayed, the display returns to the clock display. In this case, repeat the setting from step 2.
- Depending on the remote controller, the custom code may return to A when replacing the batteries. In this case, reset the custom code as necessary. If you do not know the air conditioner custom code, try each code until you find the code which operates the air conditioner.
CLEANING AND CARE
CAUTION
- Before cleaning this product, be sure to turn it off and disconnect all the power supply.
- Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
- If the filter cleaning involves high-place work, please consult the authorized service personnel.
- Do not touch the aluminum fins of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.
- Do not expose the indoor unit to liquid insecticides or hair sprays.
- Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.
- Air cleaning filters (Apple catechin filter, Ion deodorization filter)
The frequency of the cleaning is as shown in the following table.
What to do | Frequency |
---|---|
Cleaning indoor unit body | When you notice |
Cleaning air filter | Every 2 weeks |
Cleaning Ion deodorization filter | Every 3 months |
Replacing Apple-catechin filter ( Model name: UTR-FA16)
Replacing Ion deodorization filter (Model name: UTR-FA16-2)| Every 3 years
The air cleaning filters are sold separately. When you replace them, please contact the store of purchase.
Cleaning indoor unit body
NOTES:
- Do not use water hotter than 40 °C.
- Do not use scouring cleanser, volatile solvents such as benzene or thinner.
- Wipe the indoor unit body gently with a soft cloth moisten with warm water.
- Wipe the indoor unit body gently with a dry and soft cloth.
Cleaning air filter
-
Open the intake grille until it snaps.
-
Remove the air filters.
Lift up the air filters’ handle, disconnect the two lower tabs, and pull out . -
Remove the dust in either of the following ways.
- Cleaning with vacuum cleaner.
- Washing with mild detergent and warm water. After washing, dry the air filters thoroughly in shade.
-
Replace the air filters.
Align the sides of the air filter with the panel, and push in fully. Make sure to the two lower tabs are returned to their holes in the indoor unit properly. -
Close the intake grille.
Press 4 places on the intake grille to close it completely.
NOTES: If dirt accumulates on the air filter, airflow will be reduced, operating efficiency will lower, and the noise will increase.
Cleaning Ion deodorization filter and Replacing Apple-catechin filter
-
Remove the air filters. Refer to steps 1 ~ 2 of “Cleaning air filter”.
-
Remove the air cleaning filters from the air cleaning filter holder.
-
Flush the Ion deodorization filter (light blue) with high-pressure hot water until the surface of the filters are covered with water.
-
Wash the Ion deodorization filter with diluent neutral detergent. Do not ream or rub, otherwise the deodorizing effect may decrease.
-
Rinse the Ion deodorization filter with water flow.
-
Dry the Ion deodorization filter in shade.
-
Remove the Apple-catechin filter (light green) from the air cleaning filter holder.
-
Set the new or washed air cleaning filters into the air cleaning filter frames.
NOTES: Use the Apple-catechin filter as soon as possible after opening the package. The air cleaning effect decreases when the filters are left in the opened package. -
Install the air cleaning filter holders to the air filters.
Engage the 4 hooks at the rear of the air cleaning filter frame with the latch at both ends of the air filter.
Take care that the air cleaning filter does not project beyond the frame. -
Replace the air filters and close the intake grille. Refer to steps 4 ~ 5 of “Cleaning air filter”.
Replacing Ion deodorization filter
- Remove the air filters. Refer to steps 1 ~ 2 of “Cleaning air filter”.
- Remove the Ion deodorization filter (light blue) from the air cleaning filter holder.
- Install the new Ion deodorizing filter.
Removing and installing intake grille
Removing intake grille
- Open the intake grille until it snaps.
- Pull the mounting shafts while keeping the intake grille in a horizontal position.
Installing intake grille
-
While holding the intake grille horizontal, set the left and right mounting shafts into the pillow blocks at the top of the front panel.
Insert the shaft until it snaps to latch each shaft properly. -
Close the intake grille.
-
Press 4 places on the intake grille to close it completely.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the Fan
mode operation for half a day to dry the internal parts thoroughly before the
normal operation.
Additional inspection
- After long period of use, accumulated dust inside the indoor unit may reduce the performance even if you have maintained the unit properly. In such a case, a product inspection is recommended.
- For more information, consult authorized service personnel.
Filter indicator reset (Special setting)
- This function can be used if set correctly during installation. Please consult authorized service personnel in order to use this function.
- Clean the air filter when the indicator lamp show the following:
Indicator lamp | Blinking pattern |
---|---|
Blinks 3 times, at intervals of 21 seconds |
After cleaning, reset the filter indicator by pushing on the indoor unit for 2 seconds or less.
GENERAL INFORMATION
Heating performance
- This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a result, the operating performance is reduced as outdoor air temperature drops.
- If you feel that the heating performance is insufficient, we recommend you to use this air conditioner in conjunction with other kinds of heating appliance.
Automatic defrosting operation
- When outdoor temperature is very low with high humidity, frost may form on the outdoor unit during the heating operation, and it could reduce the operating performance of the product.
- For frost protection, a microcomputer-controlled automatic defrost function is equipped in this air conditioner.
- If frost forms, the air conditioner will temporarily stop, and defrost circuit will operate briefly (maximum of 15 minutes.)
- indicator on the indoor unit blinks during this operation.
- If frost forms on the outdoor unit after the Heating operation, the outdoor unit will stop automatically after it operates for a few minutes. Then the Automatic defrosting operation starts.
Auto-restart function
- In event of power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs previous operation when the power supply is resumed.
- If any power interruption occurs after the timer is set, counting down of the timer will be reset.
- After the power supply is resumed, indicator on the indoor unit blinks to notify you that there has been a timer fault. In such a case, reset the clock and timer settings.
Malfunctions caused by other electrical devices
- Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner.
- If you encounter such a malfunction, turn off the circuit breaker once. Then turn it on again, and resume operation by using the remote controller.
Indoor unit temperature and humidity range
Permissible ranges of temperature and humidity are as follows:
Indoor temperature | Cooling/Dry | [°C] | 18 to 32 |
---|---|---|---|
Heating | [°C] | 16 to 30 | |
Indoor humidity | [%] | 80 or less *1) |
If the air conditioner is used continuously for many hours, water may condense on the surface and drip.
- If the unit is operated under the conditions except the permissible temperature range, the air conditioner operation may stop because of the automatic protection circuit working.
- Depending on the operating conditions, the heat exchanger may freeze, causing water leakage or other malfunction (in the Cooling or Dry mode).
Other information
- Do not use the air conditioner for any purpose other than room cooling/dry, room heating or fan.
- For the permissible ranges of temperature and humidity for the outdoor unit, refer to the outdoor unit installation manual.
OPTIONAL PARTS
Wired remote controller
- The optional wired remote controller can be used.
- You can use wired and wireless remote controller together. However, some functions of the wireless remote controller are restricted. If you set the restricted functions, beeping sound will be heard, [1 ], and indicator on the indoor unit will blink.
- When using together with wired remote controller (2-wired type)
- Weekly timer operation
- Powerful operation
- Outdoor Unit Low Noise operation
- 10 °C Heat operation
- You can use wired remote controller and wireless LAN control (optional).
- However, some operations from the mobile app are restricted.
Multiple remote controller
- You can connect two wired remote controllers to one air conditioner. Either remote controller can control the air conditioner.
- However, the timer functions cannot be used by the secondary unit.
Group control
- One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.
- You cannot use group control and wireless LAN control together.
Wireless LAN control
The optional wireless LAN control can be used.
Multi-type air conditioner
- This indoor unit can be connected to a multi-type outdoor unit.
- The multi-type air conditioner allows multiple indoor units to be operated in multiple locations.
- The indoor units may be operated simultaneously, in accordance with their respective output
Simultaneous Use of Multiple Units
- When using a multi-type air conditioner, the multiple indoor units can be operated simultaneously, but when 2 or more indoor units of the same group are operated simultaneously, the heating and cooling efficiency will be less than when a single indoor unit is used alone. Accordingly, when you wish to use more than 1 indoor unit for cooling at the same time, the use should be concentrated at night and other times when less output is required. In the same way, when multiple units are used simultaneously for heating, it is recommended that they be used in conjunction with other auxiliary space heaters, as required.
- Seasonal and outdoor temperature conditions, the structure of the rooms and the number of persons present may also result in differences of operating efficiency. We recommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units, and use the units in the way that best matches your family’s lifestyle.
- If you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation, we recommend that you stop simultaneous operation of the multiple units.
- Operation cannot be done in the following different operating modes. If the indoor unit is instructed to do an operating mode that it cannot perform, [ ] indicator on the indoor unit will flash (1 second on, 1 second off) and the unit will go into the standby mode.
- Heating mode and Cooling mode (or Dry mode)
- Heating mode and Fan mode
- Operation can be done in the following different operating modes. Cooling mode and Dry mode
- Cooling mode and Fan mode
- Dry mode and Fan mode
- The operating mode (Heating mode or Cooling (Dry) mode) of the out-door unit will be determined by the operating mode of the indoor unit that was operated first. If the indoor unit was started in the Fan mode, the operating mode of the outdoor unit will not be determined.
- For example, if indoor unit (A) was started in the Fan mode and then indoor unit (B) was then operated in the Heating mode, indoor unit (A) would temporarily start operation in the Fan mode but when indoor unit (B) started operating in the Heating mode, [ ] indicator for indoor unit (A) would begin to flash (1 second on, 1 second off) and it would go into standby mode. Indoor unit (B) would continue to operate in Heating mode.
TROUBLESHOOTING
WARNING
In the following events, immediately stop operation of the air conditioner,
and disconnect all the power supply by turning off the electrical breaker or
disconnecting the power plug. Then consult your dealer or authorized service
personnel. As long as the unit is connected to the power supply, it is not
insulated from the power supply even if the unit is turned off.
- Unit smells of something burning or emits smoke
- Water leaks from the unit
Does not operate at all.
- Has there been a power outage?
- In this case, the unit restarts automatically after the power supply is resumed. (Refer to page 11.)
- Has the circuit breaker been turned off?
- Turn on the circuit breaker.
- Has a fuse blown out or the circuit breaker been tripped?
- Replace the fuse or reset the circuit breaker.
- Is the timer operating?
- To check or deactivate the timer setting, refer to page 6.
Poor cooling or heating performance.
- Is the unit operating under the conditions except the permissible temperature range?
- In this case, the air conditioner may stop because of the automatic protection circuit working.
- Is the air filter dirty?
- Clean the air filter. (Refer to page 9.)
- Is the intake grille or outlet port of indoor unit blocked?
- Remove the obstructions.
- Is the room temperature adjusted appropriately?
- To change the temperature setting, refer to page 5.
- Is a window or door left opened?
- Close the window or the door.
- Is the fan speed set to Quiet?
- To change the fan speed, refer to page 5.
- Has the Outdoor Unit Low Noise operation been set?
- To stop the Outdoor Unit Low Noise operation, refer to page 8.
- < In the Cooling mode> Is direct or strong sunlight shining into the room?
- Close the curtains.
- < In the Cooling mode> Are there other heating apparatus or com-puters operating, or too many people in the room?
- Turn the heating apparatus or computers off, or set the temperature lower. (Refer to page 5.)
Airflow is weak or stops.
- Is the fan speed set to Quiet?
- To change the fan speed, refer to page 5.
- Has the Fan Control for Energy Saving set?
- In this case, the indoor unit fan may stop temporarily while the Cooling operation.
- To cancel the Fan control for energy saving, refer to page 8.
- In the Heating mode > Have you just started the operation?
- In this case, the fan rotates at very low speed temporarily to warm up the internal parts of the unit.
- In the Heating mode > Is the room temperature higher than the set temperature?
- In this case, the outdoor unit stops and the indoor unit fan rotates at very low speed.
- In the Heating mode > Is [ ] indicator blinking?
- In this case, the Automatic defrosting operation is working. The in-door unit stops for maximum of 15 minutes. (Refer to page 10.)
- In the Dry mode> The indoor unit operates at low fan speed to adjust the room humidity, and may stop from time to time.
- In the Auto mode> While the monitoring operation, the fan rotates at very low speed.
Noise is heard.
- Is the unit operating, or immediate after stopping operation?
- In this case, refrigerant flowing sound may be heard. It may be particularly noticeable for 2-3 minutes after starting operation.
- Do you hear a slight squeaking sound during the operation?
- This sound is produced by the minute expansion and contraction of the front panel caused by temperature change.
- < In the Heating mode> Do you hear a sizzling sound?
- This sound is produced by the Automatic defrosting operation.(Refer to page 10.)
- Smell coming from the unit.
- The air conditioner may absorb various smells generated from interior textile, furniture, or cigarette smoke. These smells may be emitted during the operation.
- Mist or steam is emitted from the unit.
-
A thin mist may be generated by condensation formed with sudden cooling process.
-
- < In the Heating mode> Is [ 1 ] indicator on the indoor unit blinking?
- In this case, steam may rise from the outdoor unit because of the Automatic defrosting operation.(Refer to page 10.)
- Outdoor unit emits water.
-
The outdoor unit may emit water generated by the Automatic defrosting operation. (Refer to page 10.)
-
The unit operates differently from the remote controller setting.
- Are the batteries in the remote controller exhausted?
- Replace the batteries.
- Operation is delayed after restart.
- Has the power supply turned from Off to On suddenly?
- In this case, the compressor will not operate for about 3 minutes to prevent a blowout of the fuse.
Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.
- The problem persists even if you perform these checks or diagnostics.
- On the indoor unit, [ 1 ] and blink while is blinking fast.
NOTES: For any troubleshooting related to the W-LAN control, refer to the setting manual for W-LAN adapter or the mobile app installed in your smartphone or tablet PC.
State of indicator lamps
Manual Auto operation and Filter indicator reset
You can operate the air conditioner with on the indoor unit.
Status | Time to keep pressing | Mode or operation |
---|---|---|
In operation | More than 3 seconds | Stop |
Stopping | 2 seconds or less | Filter indicator reset |
More than 3 seconds and less than 10 seconds | Auto *1) | |
More than 10 seconds (Only for servicing.*2)) | Forced cooling |
- In multi connection, the operation mode follows the other indoor units.
- To stop the forced cooling, press this button or on the remote controller