Product Information

Specifications

  • The field serves BACnet, Modbus, RESTful API, and over 120 other automation protocols
  • Up to 3,000 data points with complete documentation and demo software
  • Integrates controllers directly into SCADA, Smart City, and BMS applications
  • Models:
    • FS-3000: Field Server, 3,000 data points
    • FS-1000: Field Server, 1,000 data points

Product Usage Instructions

Installation

To install the Hunter Field Server, follow these steps:

  1. Select a suitable location for the Field Server.
  2. Ensure the power supply is available and compatible with the Field Server’s requirements.
  3. Connect the Field Server to the appropriate network using an Ethernet cable.
  4. Power on the Field Server.

Configuration

The Field Server needs to be configured before it can be used. Follow these steps to configure the Field Server:

  1. Access the Field Server’s web interface by entering its IP address in a web browser.
  2. Enter the necessary network settings, such as IP address, subnet mask, gateway, and DNS server.
  3. Configure the automation protocols and communication settings according to your requirements.
  4. Save the configuration settings and restart the Field Server.

Integration with Automation Platforms

The Hunter Field Server can be integrated with various automation platforms. To integrate the Field Server, follow these steps:

  1. Consult the documentation or contact the automation platform provider to determine the integration method.
  2. Follow the instructions provided by the automation platform to add the Field Server as a device.
  3. Configure the necessary parameters and communication settings for the integration.
  4. Verify the integration by testing the communication between the automation platform and the Field Server.

Frequently Asked Questions (FAQ)

  1. How many data points can the Hunter Field Servers handle?
    • The Hunter Field Servers come in two models: FS-3000, which can handle up to 3,000 data points, and FS-1000, which can handle up to 1,000 data points.
  2. Can the Hunter Field Servers be used in both residential and commercial irrigation systems?
    • Yes, the Hunter Field Servers are designed to work with both residential and commercial irrigation systems.
  3. Where can I find more information about the Hunter Field Servers?
    • You can visit our website at hunterindustries.com for more information about the Hunter Field Servers. Additionally, you can contact your local Sales Manager for further assistance.
  4. How can I get customer support or technical service for the Hunter Field Servers?
    • If you require customer support, you can reach us at 1-800-383-4747. For technical services, please contact us at 1-800-733-2823.
  5. Who is the President of Landscape Irrigation and Outdoor Lighting at Hunter Industries?
    • The President of Landscape Irrigation and Outdoor Lighting at Hunter Industries is Denise Mullikinh.
  • The field serves BACnet, Modbus, RESTful API, and over 120 other automation protocols
  • Up to 3,000 data points with complete documentation and demo software
  • Integrates controllers directly into SCADA, Smart City, and BMS applications

HUNTER FIELD SERVERS

Enable custom irrigation management in automation platforms

  • The Hunter FS-3000 and FS-1000 Field Servers connect irrigation systems to a configurable building and industrial automation gateway. Integrators can easily interface irrigation control from Hunter ACC2 and ICC2 Controllers to networks in commercial buildings, industrial plants, and smart cities.
  • Both models provide complete and direct access to all controller commands and reports in BACnet, Modbus, and many other automation network types. Since they don’t require an internet connection, they allow integrators to create personalized commands and interactions within their custom control dashboards. Hunter Field Servers are designed to connect to Hunter A2CLAN or LANKIT Modules, or the A2C-WIFI or WIFIKIT modules for wireless 2.4 GHz operation.
  • Learn more. Visit hunterindustries.com or contact your local Sales Manager.

FEATURES & SPECIFICATIONS

Key Benefits

  • Field servers for BACnet, Modbus, RESTful API, and over 120 other automation protocols
  • Up to 3,000 data points with complete documentation and demo software with Hunter license agreement
  • Integrates controllers directly into SCADA, Smart City, and BMS applications
  • Allows total access to all controller commands, reports, and features from the customer’s integration software
  • Does not require an internet connection or other proprietary control software
  • 2 x RJ-45 receptacles for system and controller connections
  • 1 x RS-485/RS-232 and 1 x RS-485
  • DIN rail mounting included
  • Made in USA

Operating Specifications

  • Serial (galvanic isolation):
  • 1 x RS -485/RS-232 and 1 x RS-485
  • Baud: 9600, 19200, 38400, 57600, 76800, 115000
  • Ethernet: 2 x 10/100BaseT, MDIX, DHCP
  • Operating temperature: -4°F to 158°F (-20°C to 70°C)
  • Relative humidity: 10% to 95% RH non-condensing

Electrical Specifications

  • Input: 24 VAC, 0.125 A; 9 to 30 VDC, 0.25 A at 12 VDC
  • Max power: 3 W

Approvals

  • CE and FCC Part 15 C
  • BTL marked and UKCA-compliant
  • UL 62368-1 and CAN/CSA C22.2
  • RoHS3 and WEEE compliant

Model

  • FS1000 2¾” H x 3 ⅞” W x 1 ⅛” D
  • FS3000 2¾” H x 3 ⅞” W x 1 ⅛” D

MODELS

Model Chart Description

  • FS-3000 Field Server, 3,000 data points
    • FS-1000 Field Server, 1,000 data points
  • Website hunterindustries.com
  • Customer Support 1-800-383-4747 | Technical Service 1-800-733-2823
  • Helping our customers succeed is what drives us. While our passion for innovation and engineering is built into everything we do, it is our commitment to exceptional support that we hope will keep you in the Hunter family of customers for years to come.
  • © 2023 Hunter Industries Inc. Hunter, the Hunter logo, and other marks are trademarks of Hunter Industries Inc., registered in the U.S. and certain other countries.
  • Please recycle Denise Mullikinh, President, Landscape Irrigation and Outdoor Lighting

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals