Lienuis OX-60PA Crawl Space Dehumidifier User Manual
- June 15, 2024
- Lienuis
Table of Contents
USER MANUAL
CRAWL SPACE DEHUMIDIFIER
Email:support@lienuis.com
Website:www.lienuis.com
INSTRUCTIONS
Thank you for choosing the dehumidifier by Lienuis!
We hope it will bring great convenience to your work and life. We recommend
that you save the user manual properly for future reference. Before using this
product, please read the user manual carefully to ensure that this product
functions at its best.
The Lienuis’s dehumidifier adopt an upgraded design, compact structure, easy
to operate, and other characteristics, widely used in scientific research,
sanitation, commodity storage, underground engineering, and dehumidification
in high humidity places such as kitchens, bathrooms, archives, warehouses,
etc.
Can be effectively avoided telecommunications equipment, materials, etc, are
damaged due to dampness or rust.
Dehumidifier reduces humidity in enclosed environments by removing water vapor
from the air.
The Lienuis OX-60PA is ideal for crawlspace drying, humidity control and other
applications.
Transportation and Custody
During transportation, this product should be handled preciously to prevent
violent vibration. Generally, the packaged product should not be stored in the
open air for a long time. It should be placed in a well-ventilated, non-
corrosive gas warehouse. It should not be placed upside down. Set unit
upright, Always store, transport, and use the unit in a horizontal position.
If the unit is ever placed in a vertical position, return it to the horizontal
position and let it stand for at least 24 hours before turning it on.
Rainproof measures should be adopted when stored temporarily.For best results,
operate your dehumidifiers in an enclosed area. Place your dehumidifier away
from obstructions, and keep it away from anything that could block airflow
into and out of the unit.
We also kindly ask you to take a few minutes to register your product at
www.lienuis.com for more efficient support.
We are always just an email away
To access customer support,please email to
support@lienuis.com with your purchase order ID
to help us address the problem fater and serve you better.
BEFORE YOU BEGIN
This restoration dehumidifier remove moisture of room . which commonly used in
basement, warehouse, villa and many so on.
The environmentally friendly R32 is used as the refrigerant. R32 has no
damaging influence on the ozone layer (ODP), a negligible greenhouse
effect(GWP)and is available worldwide.Because of its efficient energy
properties,R32 is highly suitableas a coolant for this
application.Precautions must be taken into consideration due to the coolant’s
flammability.
SYMBOLS FROM THE UNIT AND USER MANUAL
| This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will
create harmful gas and there is risk of fire.
---|---
| Read the USER MANUAL carefully before operation.
| Further information is available in the USER MANUAL, SERVICE MANUAL, and the
like.
| Service personnel are required to carefully read the USER MANUAL and SERVICE
MANUAL before operation.
The information contained herein is subject to change without notice.
The user manual contains instructions and notes on the operation and use of
this unit.
Lienuis recommends that you use genuine accessories from Lienuis.
Lienuis shall not be responsible for any damage or expense that might result
from the use of parts other than genuine parts from the Lienuis.
Do not use unofficial components or accessories that may result in a risk of
fire, electric shock, or injury to persons. If you need to replace any
components or accessories, please visit official Lienuis channels to check
relevant information.
For your safety and benefit, please read carefully before using and keep it
handy for future reference.
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
This appliance is designed to use indoor ,not for outdoor.
-
The unit is designed only for use with R32(propane) gas as the designated refrigerant.
-
The refrigerant loop is sealed.Only a qualified technician should attempt to service!
-
Do not discharge the refrigerant into the atmosphere.
-
R32(propane)is flammable and heavier than air.
-
It collects first in low areas but can be circulated by the fans.
-
If propane gas is present or even suspected, donot allow untrained personnel to attempt to find the cause.
-
The propane gas used in the unit has no odor.
-
The lack of smell does not indicate a lack of escaped gas.
-
If a leak is detected,immediately evacuate all persons from the store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.
-
Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the room.
-
No open flames,cigarettes or other possible scurces of ignition should be used inside or in the vicinity of the units.
-
Component parts are designed for propane andnon-incentive and non-sparking.
Component parts shall only be replaced with identical repair parts. -
FAILURE TO ABIDE BY THIS WARNINGCOULD RESULT IN AN EXPLOSION,DEATH, INJURY AND PROPERTY DAMAGE.
IMPORTANT SAFETY TIPS
Your safety is the most important thing we concerned!
WARNING
Please read this manual carefully and fully understand before operating your
appliance.
OPERATIONAL PRECAUTIONS
WARNING-to reduce the risk of fire,electric shock or injury to persons or
property:
-
If the supply cord is damaged,it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard.
The appliance shall be disconnected from its power source during service. -
Always operate the unit from a power source of equal voltage,frequency and rating as indicated on the product identification plate.
-
Always use a power outlet that is grounded.
-
Unplug the power cord when cleaning or when not in use.
-
Do not operate with wet hands.Prevent water from spilling onto the unit.
-
Do not immerse or expose the unit to rain,moisture or any other liquid.
-
Do not leave the unit running unattended.Do not tilt or turn over the unit.
-
Do not unplug while the unit is operating.
-
Do not unplug by pulling on the power cord.
-
Do not use an extension cord or an adapter plug.
-
Do not put objects on the unit.
-
Do not climb or sit on the unit.
-
Do not insert fingers or other objects into the air outlet.
-
Do not touch the air inlet or the aluminum fins of the wait.
-
Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
-
Do not clean the appliance with any chemicals.
-
Ensure the unit is far away from fire,inflammable,or explosive objects.
-
The unit shall be installed in accordance with national wiring regulations.
-
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
-
The appliance shall be stored in a room witllout continuously operation sources
(for cxample:open flames,an operating gas appliance or an operating electric heater). -
The appliance shall be stored so as to prevent mechanical damage from occurring.
-
Do not piece or burn,even after use.
-
Be aware that refrigerants may not contain an odour.
-
Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space,if that space is smaller than 4 m².
-
Compliance with national gas regulations shall be observed.
-
Keep any required ventilation openings clear of obstruction.
-
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
WARNING
Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorizes their competence to handle refrigerants
safely in accordance with an industry, recognized assessment specification.
WARNING
Servicing shall only be performed as recommended by the equipment
manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use
of flammable refrigerants.
SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing an
appliance with R32.
-
Checks to the area
Prior to beginning work on systems containing flammable refrigerants,safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system. -
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed. -
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall beavoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. -
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants,i.c. no sparking,adequately sealed or intrinsically safe. -
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. -
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking,should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.”No Smoking”signs shall be displayed. -
Ventilated area
Ensure that the area is in the open or that it is adecquately ventilated before breaking into the system or conducting any hot work.A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. -
Checks to the refrigeration equipment
Where electrical components are being changed,they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed.If in doubt consult the manufacturer’stechnical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
-The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
-The ventilation machinery and outlets areoperating adequately and are not obstructed;
SPECIFICATIONS
Model | OX-60PA |
---|---|
Dehumidify Capacity(86fi, 80%RH) | 110Pint/Day |
Power Supply | 110-120V~ 60Hz |
Rated Input Power/Current | 567W/5.0A |
Maxi Input Power/Current | 818W/5.9A |
Refrigerant/Charge | R32/5.65oz |
Noise | ≤60dB(A) |
Low Side Pressure | 260 Psi |
High Side Pressure | 550 Psi |
BCSC | 15A |
Compressor Input | RLA:3.25A/ LRA:20A |
Fan Motor Power | 0.75A/0.115HP |
Product Dimensions(inch) | 22.31413.9 |
Net Weight | 61.72lbs |
Gross Weight | 70.54lbs |
PRODUCT OVERVIEW
OPERATION INSTRUCTION
Button Description
A.On/Off(Power) Button
Press the on/off button and the machine will start running (one beep). Press
the button again to the turn the machine off. this button while on electric,
screen light on, machine automatically goes to standby mode,display screen
shows environmental humidity.
B.Mode Button
Press the “mode” button, you can choose to working mode, auto mode/
continuously drying mode / sleep mode, the corresponding mode lights on.
C.Timer
Timer/untimer can be set,while the machine is running, press the timer button
light goes on, press “+” “-” to set the time to stop the machine, or machine
is on stop status, press the timer button and press “+” “-” to set the time to
open the machine.
D.ADD Button
Press this button to adjust the set humidity (20-90%) or timing time (0-24h)
in an upward cycle.Press the button for 3 seconds to switch between Fahrenheit
and Celsius temperatures.Increase the humidity by pressing this button at
normal mode, humidity increase 1%RH with each press, buzzer rang each time
with the press, press the button for 1 second can increase the humidity
continuously;
E.Minus Button
Press this button to down cycle to set humidity (20-90%) or timing time
(0-24h).Press the button for 3 seconds, then the temperature display will
blink to display the coil temperature, and the ambient temperature will still
be displayed after 5 seconds.ecrease the humidity by pressing this button at
normal mode, humidity decrease 1%RH with each press, buzzer rang each time
with the press, press the button for 1 second can decrease the humidity
continuously;
Operating Mode
-
Auto Mode
Default auto mode after on electric (default setting humidity 50%)
a) Environmental humidity>machine set humidity+3%, compressor, and fan start running. Environmental humidity<machine set humidity+3%, the compressor stops, and the fan stops after a delay of 5 seconds, and the compressor meets the three- minute delay protection.
The machine set humidity+3% ≤ environmental humidity ≤ machine set humidity+3%, and keeps running in the original state.
b) The setting humidity is adjustable (20%-90%), and the ambient humidity (20%-95%) is displayed after the humidity setting is completed. -
Continuously Drying Mode
Press the mode button to select the continuously drying mode, and the light is on.
a) The humidity cannot be adjusted, and the compressor can run continuously without being restricted by the ambient humidity (to meet the three-minute delay protection of the compressor)
b) Displays ambient humidity (20%-95%). -
Sleep Mode (Default humidity 60%, humidity adjustable)
a) Press the mode button to select the sleep mode, and the light is on.
b) In sleep mode, if there is no button operation for 10 seconds, the display will enter a dark state.
If there is a button operation in sleep mode, it will return to normal display. After 10 seconds, if there is no other button operation, it will continue to enter the dark display state.
c) In sleep mode, if there is a fault or the water is full, do not beep and the fault code will be dimly displayed.
Humidity Control
In auto mode or sleep mode, press the up and down adjustment button to
cyclically adjust the set humidity. Each time the up (or down) button is
pressed, the set humidity will increase (or decrease) by 1%.
During the adjustment of the set humidity, the set humidity will flash and
display, after the adjustment is completed, it will flash and display 5 times
to confirm, and then switch to display the ambient humidity.
Additional Function
-
Intelligent defrosting: When a defrosting signal is detected, defrosting will start, and the corresponding mode light will flash.
-
Timing function: can set timing/query timing/cancel timing
a) In the non-timing state: press the “timing” key to enter the timing setting state, the digital flashes to display the timing time, and press the up and down keys to adjust the timing time (0~24h) during the flashing period.
b) In the timing state: press the “timing” button, the timing time will be displayed by flashing, and press the “timing” button again during the flashing to cancel the timing. -
Water-full protection: When the water-full signal is detected, the water-full light is on and the digital flashes to display “FL”, the buzzer beeps 5 times to alarm, and the machine is turned off. After power failure and drainage, resume normal operation.
Installation and assembly of accessories
Ⅰ: Take out the accessories from the packing box: ceiling mount gasket, screws
Ⅱ: Take out the duct adapter and adjustable rubber feet from the machine body
- Unscrew the 2 screws under the lower cover, and remove the lower front panel.
- Use a screwdriver to remove the 2 screws on the top cover and remove the top front panel.
- Take out the duct adapter and adjustable rubber feet from the machine body.
- After the accessories are taken out, install the top front panel and lower front panel.
Ⅲ: Ducting installation
-
Align the duct adapter with the 4 screw positioning holes on the side.
-
Lock and fix the duct adapter with screws.
-
The user can put the exhaust pipe (purchased by the user according to the demand) on the duct adapter, and it must be placed within the buckle position.
-
You can install the flex duct yourself,the duct adapter diameter is 6.88inch/17.5cm.
Ⅳ: Adjustable feet installation
When the machine is placed on the ground or used on some platforms, feets need
to be installed
- It is necessary to install 4 feets on the bottom plate of the body.
- Adjust the height of the position adjustment nuts of the 4 feets to a suitable position
- Assemble the 4 feets in the threaded holes on the bottom plate of the body respectively, and lock tighten.
Ⅴ: Ceiling mount gasket installation
When the machine is suspended in the air, the machine needs to be installed
with ceiling mount gasket.
- Install the ceiling mount gasket in the body (accessories: 4 ceiling mount gaskets, 12 spring spacers, 12 flat spacers, 12 screws)
- 1 screw with 1 spring shim and 1 flat shim.
- Screw the shimmed screw through the boom hole and screw it into the threaded hole on the base plate of the machine and lock tighten.
- Each ceiling mount gasket is installed with 3 screws, and the 4 ceiling mount gasket are assembled on the bottom plate of the machine and locked tighten.
Ⅵ: Wall assembly method for control panel
When the machine is shipped, the control panel is assembled on the front of
the machine.
In order to facilitate the user to install the control panel on the wall, the
control panel needs to be removed and the control panel installed on a wall
surface that is convenient for operation, as follows.
-
Remove the 2 handel screws of the lower cover below the machine.
-
Pinch the handel screws in the middle of the front panel below with your hands and pull outward with gentle force to pull the front panel apart.
-
screwdriver to screw down the 2 fixed screws and remove the control panel assembly, then install the cover in the location of the control panel of the machine and fix it with 2 screws.
-
Remove the upper cover of the control panel assembly with a screwdriver; then remove the 2 screws and remove the lower cover.
-
Mount the lower cover of the control panel assembly on a wall where it can be easily operated.
-
Connect the signal wires to the terminals of the control panel inside the upper cover of the control panel assembly, install them in place, and then fix the upper cover on the lower cover.
-
Then plug the other end of the signal cable of the control panel into the signal interface of the machine.
Drainage Method
I: Water pipe drainage method
Operation instructions: When using the water pipe drainage method, connect the water pipe at the drain, place the water pipe in place, place the other end of the water pipe at the drain, or at the drain sink, or in the water storage container; turn on the machine to use the water pipe drainage method.
Dehumidifiers Adopt Drain by Gravity, the collected condensation water can be drained by gravity.When using gravity to drain:
- Connect the drain hose to the Gravity Drain Outlet;
- Place the unattached end of the hose in a suitable drainage facility. The drainage facility should be lower than the drainoutlet of the dehumidifier. (Ensure there are no kinks or other obstructions that will stop the water to flow.)
Note:
- lf you use a bucket or other container for water collection,check it regularly to prevent overflows.
- Connecting a drain hose that is too long is not recommended,as it may cause water to back up, causing a leak.
- lf the drain hose is too long, water may not drain completely.which can lead to stagnant water and mildew building up inside the hose.
- Before moving the dehumidifier, make sure the condensed water inside is completely drained to avoid water leakage.
Ⅱ.External pump drainage method(not include pump,need to buy)
When it is necessary to connect an external water pump, oneend of the
drainpipe is connected to the water outlet, and theother end is connected to
the water inlet of the water pump.
Note:The reserved external water pump signal input port cannot be
connected to the power supply, so as not to cause the main board ofthe product
to burn out.
Operating instructions: When using the pump drainage method, the operation is as follows.
- The two ends of the water pipe A, one end connected to the machine drain, must be placed in place; the other end placed in the water pump inlet, placed firmly.
- Connect one end of the water pipe B to the water pump discharge port, and place the other end of the water pipe in the sewer opening, or drainage sink, or water storage container; Note: the length of the water pipe B must be within the range of the pump’s head.
- Plug one end of the pump signal line into the pump signal line interface of the machine and assemble it in place.
- Plug the power cord of the pump into a solid, suitable socket.Pump power on, turn on the machine can be used to drain the water pump.
Cleaning and Maintenance
Note: Before cleaning and maintaining the machine, please make sure to
turn off the machine and unplug it from the power source to prevent electric
shock.
Cleaning :
Before doing any cleaning and maintenance work on the machine, the machine
must be turned off, unplugged, and no water should be spilled on the machine.
Use a soft, damp cloth to clean the casing. Do not use chemical solvents such
as benzene, alcohol or gasoline, otherwise, the machine casing will be damaged
or even deformed.
Filter cleaning:
The machine is equipped with a washable filter, it is recommended to clean the
filter every 2 weeks.
If the filter is blocked by dust, it will reduce the efficiency of the
machine.
I: Cleaning the filter.
-
Remove the filter
(1) Remove the handle screws on both sides above the air inlet frame.
(2) Pinch the handle screws in the middle above the air inlet frame with your hands, pull outward with a little force, and pull the air inlet frame rotate (such as the rotating arrow)
3).Remove the filter.
-
Clean the filter
Use a vacuum cleaner to gently absorb the dust on the surface of the filter. If the filter is very dirty, you can use tap water to rinse the filter, and completely cool and dry it, then put it back into the forward air sheet, which can improve the performance of the machine.
Suggestion: Clean the filter once after every 3 months of use. -
Assemble the filter and air inlet frame
(1) The filter will be put into the assembly of the air inlet frame buckle position, need to be assembled in place.
(2) The air inlet frame will be held up with force, the air inlet frame will be rotated and assembled to the machine inside, which must be assembled in place.
(3) Lock the handle screws on both sides above the air inlet frame to fix it.
Ⅱ. Machine body cleaning
Use a soft, slightly damp cloth to wipe the body.
Ⅲ. Machine storage
When you do not use this product for a long time and intend to store it, pay
attention to the following steps.
- Drain the water from the machine body.
- Tidy up the power cord.
- Clean the filter.
- Place it in a fresh and dry environment.
Part List
Picture | Name | Quantity |
---|---|---|
Dust adapter | 1 PC | |
External pump full water signal input cable | 1PC | |
Control panel external connection cable | 1PC | |
Control panel hole cover | 1PC | |
Drain pipe | 1PC | |
Adjustable feet | 4PCS | |
Gasket | 4PCS | |
User manual | 1PC |
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Machine Won’t Run | Power outage | Restoration of power supply |
Power plug is not connected well | Connect the plug to the socket | |
Room temperature over 113 ℉ or below 38℉ | The machine’s protection |
device is activated so that the machine does not run
Low Air Flow| Filter with dirt accumulation| Cleaning filters
The air inlet or outlet is blocked| Remove obstructions
Refrigerant leakage| Contact agent or manufacturer for repair
Water Leakage| Clogged outlet pipe| Remove the panel to remove the blockage at
the water pipe, or water outlet
Loud Noise| Machine Is Not level| Move the dehumidifier to flat, firm ground
Filter Mesh is Blocked| Clean the filter mesh according toinstructions listed
in manual
Trouble Code:E1| Temperature and humidity sensor failure| Check, or replace
the temperature and humidity sensor
Trouble Code:E2| Coil sensor failure| Check, or replace the coil sensor
Trouble Code:CL| When the ambient temperature Tr< 36℉, “CL” will be displayed
and the compressor will stop immediately, and the fan delay will be executed
according to the set value (F1 default 0, delay 5 seconds to stop). When the
ambient temperature rises to ≥ 39℉, normal operation will resume.
Trouble Code:CH
| When the ambient temperature Tr> 113℉, “CH” will be displayed, the compressor will stop immediately, and the fan delay will be executed according to the set value (F1 default 0, delay 5 seconds to stop); when the ring temperature ≤ 108℉, normal operation will be resumed.
Trouble Code:L0
| When the ambient humidity Hr< 20%, “LO” will be displayed, the compressor will stop immediately, and the fan delay will be executed according to the set value (F1 default 0, delay 5 seconds to stop). After the humidity rises > 20%, resume normal work.
Trouble Code:HI
| When the ambient humidity Hr>95%, “HI” is displayed and the compressor and fan work normally.
After the humidity falls back to <95%, it will resume normal operation.
Customer Service
Lienuis offers a limited 1-year free warranty on these crawl space
dehumidifiers,with original proof of purchase(typically you maybe only
requested to offer the order number or other information to prove a genuine
purchase,instead of an invoice) and where a defect has arisen, wholly or
substantially, as a result of faulty manufacture,parts or workmanship during
the warranty period.
During the warranty period,for the damaged part, we will provide a replacement
part if it can be restored to normal use by replacing parts.
The warranty does not apply where damage is caused by other factors,including
without limitation.
Normal wear and tear;
Abuse,mishandling, accident, or failure to follow operating instructions;
Exposure to liquid or infiltration of foreign particles;
Servicing or modifications of the product other than by Lienuis;
We will try our best to inspect the dehumidifier through photos or videos to
troubleshoot and ensure that we can better solve the problem for you.
These are our general terms for warranty service, but we always urge our
customers to reach out to us with any issue, regardless of warranty terms.
If you have an issue with a Lienuis product, please contact us at
support@lienuis.com,and we will do our best to
resolve it for you.