Lienuis D023H 25 Pints Dehumidifiers User Manual

June 14, 2024
Lienuis

Lienuis - logo

lienuis.com
USER MANUAL
MODEL: OL12-D023H
support@lienuis.com

Lienuis D023H 25 Pints Dehumidifiers -

www.lienuis.com

BEFORE FIRST USE:

To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in.

BEFORE YOU BEGIN

Please read the operating instructions carefully before using your dehumidifier for the first time.
The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity.
The environmentally friendly R134a is used as the refrigerant. R134a has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because of its efficient energy properties, R134a is highly suitable as a coolant for this application. Special precautions must be taken into consideration due to the coolant’s high flammability.
SYMBOLS FROM THE UNIT AND USER MANUAL

WARNING| This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.
---|---
| Read the USER MANUAL carefully before operation.
| Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.
| Service personnel are required to carefully read the USER MANUAL and SERVICE MANUAL before operation.

1.2 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

  • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • The unit is designed only for use with R-134a (propane) gas as the designated refrigerant.

  • The refrigerant loop is sealed. Only a qualified technician should attempt to service!

  • Do not discharge the refrigerant into the atmosphere.

  • R-134a (propane) is flammable and heavier than air.

  • It collects first in low areas but can be circulated by the fans.

  • If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.

  • The propane gas used in the unit has no odor.

  • The lack of smell does not indicate a lack of escaped gas.

  • If a leak is detected, immediately evacuate all persons from the store, ventilate the room
    and contact the local fire department to advise them that a propane leak has occurred.

  • Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the store.

  • No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.

  • Component parts are designed for propane and non-incentive and non-sparking.
    Component parts shall only be replaced with identical repair parts.

FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMA

IMPORTANT SAFETY TIPS

IMPORTANT NOTICE FOR FIRST TIME USE

ELECTRICAL INFORMATION

  • Be sure the dehumidifier is properly grounded. To minimize shock and fire hazards, proper grounding is important. This power cord is equipped with a three-prong grounding plug for protection against shock hazards.

  • Your dehumidifier must be used in a properly grounded wall socket.
    If your wall socket is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper socket.

  • Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug.

  • Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.

  • Do not pinch, bend, or knot the power cord.

SAVE THESE INSTRUCTIONS / FOR HOUSEHOLD USE ONLY
Your safety is the most important thing we concerned!

Please read this manual carefully and fully understand before operating your dehumidifier.

2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or property:

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The A-weighted sound pressure level is below 36 dB.
  • The appliance shall be disconnected from its power source during maintenance.
  • Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  •  Do notimmerse or expose the unit to rain, moisture or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  •  Do not unplug while the unitis operating.
  • Do not unplug by pulling on the power cord.
  •  Do not use an extension cord or an adapter plug.
  •  Do not put objects on the unit.
  •  Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminum fins of the unit.
  •  Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  •  Ensure the unitis far away from fire, inflammable, or explosive objects.
  • The unitshall beinstalled in accordance with national wiring regulations.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
  • The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  •  Do not piece or burn, even after use.
  •  Be aware that refrigerants may not contain an odour.
  •  Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 4m?.
  • Compliance with national gas regulations shall be observed.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.

Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. If you don’t understand something or need help, please contact the Lienuis services
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a dehumidifier with R134a.

  1. Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

  2. Work procedure
    Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.

  3. General work area
    All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  4. checking for presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.

  5. Presence of fire extinguisher
    If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  6. No ignition sources
    No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

  7.   Ventilated area
    Ensure thatthe area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  8. Checks to the refrigeration equipment
    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed.
    If in doubt consult the manufacturer’s technical department for assistance.
    The following checks shall be applied to installations using flammable refrigerants:
    – The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
    – The ventilation machinery and outlets are operating adequately and are not obstructed;
    – If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    – Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    – Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

  9. Checks to electrical devices
    Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
    Initial safety checks shall include:
    -Those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
    -That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
    -That there is continuity of earth bonding.

PRODUCT OVERVIEW

3.1 Parts Diagram

Lienuis D023H 25 Pints Dehumidifiers - parts diagram

3.2 FEATURES

  • Powerful moisture removal (up to 25Pints/12L/day dehumidification)
  • Humidity Monitor shows current air humidity
  • Auto mode automatically adjusts humidity levels
  • A 12-hour timer to set the time of operation
  • Effectively removes moisture, dust from the air
  • Low power consumption-energy efficient
  •  Quiet fan has two speed settings
  •  Auto-Defrost at low temperature
  •  Auto shut-off/ auto restart
  • Electronic control
  •  Continuous drainage or 0.53 Gal/2L water tank

3.3 SPECIFICATIONS

MODEL OL12-D023H
Dehumification Capacity 25Pints/Day (86°F, 80%)
Power Supply AC115V/60Hz
Power Consumption 195W/2A
Noise 536d B(A)
Water Tank Capacity 0.53Gai/2.0L
Maximum Refrigerant Charge R134a/3.70oz
Net Weight 10.5Kg/23LBS
Maximum Design Pressure High Side: 204psi(1.41Mpa) Low Side:88psi(0.60MPa)
Dimension 10.0″ 8.5″ 19.5″   (in)

INSTALLATION

4.1 LOCATION

  1. Place the unit on a firm, level surface in an area with at least 30cm of free space around it to allow for proper air circulation.
  2. Never install the unit where it could be subject to:
    • Heatsources such as radiators, heat registers, stoves or other products that products that produce heat.
    •  In an area where oil or water may be splashed
    •  Direct sunlight
    •  Mechanical vibration or shock
    •  Excessive dust
    •  Lack of ventilation, such as cabinet or bookcase
    •  Uneven surface

WARNING
Install the unit in rooms which exceed 4 m%
Do not install the unit in a place where inflammable gas may leak.
NOTE
The manufacture may provide other suitable example or may provide additional information about the refrigerant odour.

4.2 OPERATING THE DEVICE SAFELY

  • Check the device after unpacking for any damages or scratches on it.
  • Operate this unit in an ambient temperature from 41°F to 95°F.
  • Do not use in the outdoors. This dehumidifier is intended for indoor residential applications only.
  • Do not operate in close proximity to walls, curtains, or other objects that may block inlet and outlet.
  • Keep the air inlet and outlet free of obstacles.
  • Adjusting the wind deflector in the upward direction prior to start up.
  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
  • Keep doors and windows close for better energy saving.
  • Do not operate or store the unit in direct sunlight or rain.
  • It is normal for air outlet to feel warm to touch after continuous operation on hot days.
  • Empty the water tank before moving the device.
  • Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
  • The dehumidifier starts up in the mode selected when the unit was last used.
  • The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected humidity.
  • There is a protective 3-minutes time delay of the compressor. Wait 3 minutes for the dehumidifier to resume dehumidification.

5.1 DIGITAL DISPLAY

Lienuis D023H 25 Pints Dehumidifiers - digital display

POWER
In the standby state, press the power button to turn on, the operation indicator lights up and the default fan speed is high, and the default humidity is 50%. In the power-on state, press the power button to turn off, the running indicator light goes off and the compressor stops immediately, and then the fan shut down after 30 seconds delay.
MODE
Auto mode – continuously drying mode-sleeping mode cycle, press once to switch the mode from one to another, the corresponding indicator lights up.

  • Auto mode :when environmental humidity = set humidity +3%, the fan starts working and compressor starts working after 3 seconds. When environmental humidity < set humidity -3%, the compressor stops working and fan stops working after 30 seconds’ delay.
    Both fan speed and humidity can be adjusted under auto mode.

  •  Continuously drying mode: The machine continues to run, but the humidity can not be adjusted.

  •  Sleeping mode: Touch the sleep button, the button lights up and start the sleep function.
    After no operation in 10 seconds, all indicators turns dark gradually and the wind speed is automatically switched from high to low. Touch any button to wake up the indicator.
    Touch sleep button again to exit the sleep mode.
    When environmental humidity < 57%, compressor stops working and the fan shut down after 30 seconds’ delay.
    When environmental humidity = 63%, the fan starts working and compressor starts working after 3 seconds.
    Fan speed and humidity can not be adjusted under sleeping mode.
    TIMER
    Press the timer button to set the 0-12 hour timing function. The interval is 1 hour.
    Each time you press this button, the value increased 1 hours and then the corresponding timing value is displayed on the screen. The setting value is “00” to cancel the timer function.
    The indicator turns out. After the timer is set and completed, the timer LED is on during the timing period. After the timing is over, the timer LED turns off automatically.
    In the running state, set the time to turn off the machine; in the standby state, set the time to turn on the machine.
    HUMIDITY SET
    Touch the humidity button to check the current environment humidity, touch this button again and you can set the humidity. The range of target humidity is 30%- 35% – 40% – 45% – 50% – 55%- 60% – 65% -70% – 75%- 80%. After setting 3 seconds, the system confirms the input value and then the machine exits the setting state, and returns the current humidity. In the drying mode, the target humidity cannot be changed.
    Long Press humidity button for 3 seconds to display the current ambient temperature.
    SPEED
    High wind – low wind cycle, press button once to switch and then the corresponding indicator lights up. In continuously drying mode, sleep mode and defrosting period, the wind speed can not be changed.
    CHILD LOCK
    Long press 3 seconds to turn on/off the child lock function.

5.3 DRAINAGE
There are two ways of removal collected water produced by the unit.
A. Manual draining: Empty water tank by manual.
B. Continuous draining: Use gravity to drain condensate water by attaching a drain hose.
5.3.1 EMPTYING THE WATER TANK
The water tank built in unit will fill up and shut the unit down once it is full. It will run again once you empty the water tank and installed properly.

  • When the tank is full, The unit will make a buzzing sound, and the “Water Full” light will turn on.
  • Press the POWER button to turn off the unit.
  • Pull on the water tank and simply slide out of the body of the dehumidifier.
  • Empty the water into an area with a drain or outside.
  • Clean the inside of the tank as well as the outside.
  • Replace the empty tank back into the unit.
  • Press the POWER button to resume operating.
  • If the Water Full light does not extinguish, check that the float is correctly in place.

Lienuis D023H 25 Pints Dehumidifiers - power button

5.3.2 CONTINUOUS DRAINING
For continuous operation or unattended dehumidification, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity.

  •  Set the unitin a horizontal surface and stable position.
  • Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
  • Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
    Do not submerge the end of hose into water; otherwise it can cause “Air Lock” in the hose.

To avoid water spillage:

  • As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor.
    It is appropriate that the degree of inclination should exceed 20 degrees.
    Straighten the hose to avoid a trap existing in the hose.

CONTINUOUS DRAINAGE PIPE INSTRUCTIONS

Lienuis D023H 25 Pints Dehumidifiers - power button2

MAINTENANCE

CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Remove the filter frame and take off the filter.

  2. Use a vacuum cleaner to gently absorb the dust on the surface.
    If the filter is very dirty, wash it with water and a soft detergent and dry it thoroughly afterwards.

  3. Put the filter back.

What’s In The Box

Picture Name Quantity
Dehumidifier 1PCS
Drain Hose 1PCS
User Manual 1PCS

TROUBLE SHOOTING

  1. FUNCTIONING TEMP
    41°F <Ambient Temp < 95°F
    When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops.
    When 41°F < Ambient temp < 60°F, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running.

  2. BEFORE CONTACTING FOR SERVICE
    Before contacting professional service, please review the trouble shooting list that includes common occurrences that are not the result of a defect in workmanship or materials.

Problem Possible Cause Solution

Not working

| No power supply| Connect to a functioning outlet and switch on
Water Full Indication Flashes| Drain water tank and reset it, or re-position the water tank to right place
Room temperature < 41°F,or >95 oF| Self-Protection designed to protect the unit. Can not work under such temperature

Bad functioning

| Is the air filter clogged?| Clean the air filter as instructed
Is the intake duct or discharge duct obstructed?| Remove the obstruction from the discharge duct or intake duct.
No air intake| Is the filter clogged?| Wash the filter
Loud noise
when running| Is the machine put in the plat place?| Put the machine on the plat ground
Is the filter clogged?| Wash the filter
E2 ,| Humidity sensor problem| Change a sensor
LO| Environmental humidity is below 20%|

The dehumidifier shuts down for self-protection

HI| Environmental humidity is above 90%
CL| Low temperature protection, the environmental temperature< 41°F
CH| High temperature protection, the environmental temperature >95°F

DECOMMISSIONING

8.1 STORAGE
Long-term storage – If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely.
Please store the unit per the following steps:

  1. Press power button to switch off and unplug the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Collect the power cord at the water tank.
  5. Re-install the filter at its position.
  6. The unit must be kept in upright position when in storage.
  7. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.

ATTENTION:
The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit s to set the humidity point more than 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.
8.2 DISPOSAL
WARNING!!! 

Releasing refrigerant into atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in land&fills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.

SAFETY PRECAUTIONS

  1. When using, do not place the dehumidifier on soft, uneven ground to avoid vibration or movement.

  2. Do not use thin rods or hard objects to insert into the fuselage to avoid malfunction or danger.

  3. When using, please keep the dehumidifier away from heat sources such as heaters and electric kettles to save electricity.

  4. When using, please close the doors and windows to achieve the best dehumidification effect.

  5. Do not place items before and after the dehumidifier. If the ventilation is blocked, the dehumidification effect will be affected.

  6. In case of power failure or long-term non-use, please unplug the power cord.

  7. When dleaning the dehumidifier, gently wipe it with a damp cloth, do not directly spray water to clean it.

  8. Do not place any objects on the dehumidifier.

  9. Please clean the filter every two weeks (do not use hot water above 104°F/40°C, alcohol, gasoline, or toluene).

  10. During continuous drainage, the drainage pipe must be placed horizontally or downwards, and must not be uneven or entangled.

  11. After the filter is cleaned, please do not place it in direct sunlight todry it o avoid deformation.

  12. Before moving or carrying the dehumidifier, please pour out the accumulated water in the water tank.

CUSTOMER SERVICE

Lienuis offers a limited 1-year free warranty on this OL12-D023H dehumidifier,with original proof of purchase(typically you maybe only requested to offer the order number or other information to prove a genuine purchase,instead of an invoice) and where a defect has arisen, wholly or substantially, as a result of faulty manufacture,parts or workmanship during the warranty period.
During the warranty period,for the damaged part, we will provide a replacement part if it can be restored to normal use by replacing parts.
The warranty does not apply where damage is caused by other factors,including without limitation:

  • Normal wear and tear;
  •  Abuse,mishandling, accident, or failure to follow operating instructions;
  • Exposure to liquid or infiltration of foreign particles;

Servicing or modifications of the product other than by Lienuis .
We will try our best to inspect the dehumidifier through photos or videos to troubleshoot and ensure that we can better solve the problem for you.
These are our general terms for warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms.
If you have an issue with a Lienuis product, please contact us at support@lienuis.com,and we will do our best to resolve it for you.

Email
support@lienuis.com

Lienuis - logowww.lienuis.com
support@lienuis.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals