CDDLC ICM10A 3 Bank Marine Battery Charger 10X3 User Manual
- June 15, 2024
- CDDLC
Table of Contents
CDDLC ICM10A 3 Bank Marine Battery Charger 10X3
Marine Charger 1 QX3
IMPORTANT SAFETY INSTRUCTIONS: DANGER
Please read and understand all safety information before using this product. Failure to follow these safety instructions could lead to electric shocks, explosions, and fires may result in serious injury, death.or property damage.
-
Before using the charger, make sure that the compatible battery series of the charger includes voltage and chemical composition of the battery. Charging modes (12V SLNAGM MODE; 12V LITHIUM MODE; 12V CALCIUM MODE)are designed for different types of batteries. Using the wrong charging mode can damage your battery, accessories. FirstPower Pro is not responsible for user safety and damage when using parts not sold by FirstPower Pro.
-
Personal precautions:
-
When near the lead-acid battery when working, consider asking someone nearby to help you.
-
Have plenty of fresh water and soap nearby to prevent contact
with the battery acid. -
Wear complete eye and clothing protection.
-
Avoid contact with your eyes after contact with battery and
related materials, if acid gets in your eyes, rinse with cold water for at least 10mins and seek immediate medical attention. -
Keep metal tools aways from battery, metal objects may cause sparks or battery short circuit, resulting in electric shock, fire
explosion. -
Adults who purchase, if consent for minors to use the product, must be provided with correct instruction products and safety warnings, and the purchase is responsible for any damage and loss resulting from failure to comply.
-
Do not allow children to use unattended products and accessories that may pose a choking hazard to children.
-
Do not use damaged products with cracked enclosures, damaged cables, damaged plugs or other dangerous damage.
-
When the charger is not in use, it can be safely placed in a humid cabin; Thanks to its IP68 waterproof rating, it is protected against water damage. However, before charging, it is crucial to check for any presence of water in the charger, plug, battery, and surrounding environment. If water is found, make sure to thoroughly dry these areas before initiating the charging process to prevent any risk of electric shock! ! !
-
To avoid electric shock, when disconnecting the product, use a plug instead of a cable to pull. Please remove the product from the AC power socket.
-
The oprates temperature range of-4° F to 104° F (-20°C to 40°C) and stores in the temperature -40° F to 140° F (-40°C to 60°C) . Do not operate and store outside the temperature range. Do not charge a frozen battery, if the battery overheats, stop using the product.
-
Disassemble and clean, do not remove the product, which may cause electrical, fire, or property damage. Any modification to the product will void your warranty. If the products are damaged or cannot be used, please contact us.
-
Place the product away from the battey as long as the cable allows. Do not place the product directly on the charging battery above, the gas in the battery can corrode and damage the charger. Prevent battery acid from dripping onto the charger.
-
Do not handle this product in confined spaces or areas with limited ventilation.
-
An explosive atmosphere: Do not operate products in potential explosive environments in areas where products are present, including fuel areas and chemicals or an area of particles, such as particles, dust, or metal powder.
-
Medical equipment: The product may emit electromagnetic fields, which may interfere with the heart pacemaker, defibrillator or other medical device. Consult your doctor before using this product.
-
Radio frequency interference. Product design, test and find compliance with regulations governing RF emissions. Such emissions from the product may have a negative effect on the operation of other electronic equipment surface impact, causing them to malfunction. FCC statement this device has been tested and conforms to Class B in accordance with Part 15 of the FCC Rules Limitations of digital devices. These restrictions are intended to provide reasonable protection for residential installations against harmful interference.
The production and use of this equipment And radiates radio frequency energy, which may cause harmful interference with radio communications if not installed and used according to the instructions.
If the device does cause harmful interference with radio or television reception, can be determined by turning the device off and on, then the user is encouraged to try to correct the interference by one or more of the following measures: -
Relocate or relocate the receiving antenna.
-
Increase the distance between the equipment and the receiver. @. Connect the device to the one connected with the receiver.
The circuit is different on the socket. -
Ask dealers or experienced technicians for help.
-
This product offers 3-year warranty.
BASIC PARAMETERS
Item | Details |
---|---|
Model | ICM10A |
2 | Input Voltage |
3 | Input Power |
4 | Frequency |
5 | Output Voltage |
6 | Charger Type |
7 | Output Current |
**** 8 | **** Battery Type |
- SLA/AGM: wet cell, gel, enhanced flooded, maintenance-free/LiFePO4 LITHIUM/CALCIUM/LEAD-ACID/
- GEL/MFNRLA/EFB/Compatible start stop
9| Suitable for Battery| 30Ah-300Ah
10| Time of Charge| 4-40 hours
11| Display Mode| LED
12| Battery Repair Function| Available
13| 72 Hours Timer| Available
14| Force Mode| Available
15| Operating Temperature| -4′ F to 104′ F (-20′ C to 40′ C)
16| Storage Temperature| -40′ F to 140′ F (-40′ C to 60′ C)
17| Ambient Humidity| 5% to 95%
18| Input Cable| SPT216AWG 2•0.824mm’ L=1.8m/72-inch
**** 19| Output Cable (Optional)| #14AWG•2 80′ C 300V
L=2m/79-inch cable withalligator clip
20| Waterproof Rating| IP68
21| Reverse Connection Protection| Available
22| Overheat Protection| Available
23| Short Circuit Protection| Available
24| Full Auto Stop| Available
25| Certifications| CE FCC ROHS
PRODUCT CONNECTIONS & ACCESSORIES
HOW TO CONNECT?
TO PREVENT ELECTRIC SHOCK: If you want to stop charging, unplug the power plug before disconnecting the battery
POWER DISPLAY
icon | Description |
---|---|
The five grid power display lights are respectively, 20%,40%,60%,80%,100% | |
Power Display (Red) |
PANEL DISPLAY
icon| Correlation
Model
| Description
---|---|---
SLAIAGM
| 1 2V SLA/AGM MODE| Used for 12V wet cell, gel, enhanced flooded, maintenance free, & AGM batteries.
LITHIUM
| 12V LITHIUM| Used for 12v lithium-ion batteries LIFePO4 ( including lithium
iron phosphate). Only for batteries with battery management systems (BMS).
CALCIUM| 12V CALCIUM| ****
Used for 12V calcium batteries.
R 1 p 1 1,
| ****
12V
Repair MODE
| Used to repair old, idle, damaged, stratified, or sulfated batteries. G). lfyour 12V battery acess voltage is higher than 15V, Over voltage indicator light **is on, the repair will be turned on automatically: the repair indicator light ****is on , and the power indicator light**
(Green)——– : jumps from right to left. 2 . Within 2 hours: If the charger charges normally, the power indicator light is on———- , it means the repair is successful. If more than 2 hours, the bad battery indicator light is on, indicating that the repair has failed.
| ****
Force Mode
| When the battery is lower than 1V, it cannot be charged, the power indicator
light is not on—– . You need to switch to suitable mace. Then press and hold
the MODE button for 5s, the power red indicator will blink for 5
mins . If the activation is successful, it
normal charging , the power indicator light is on—– .
---|---|---
icon| Protection Mode| Description
---|---|---
| Over Voltage| If access voltage is higher than 15V, will not be
able to charge and Over voltage light is on. Reasons: 1 ). The wrong
battery may be connected, such as 24V, please change a 12V battery; 2. If your
battery is 12V indeed, but acess voltage is higher than 15V, the repair will
be turned on automatically.
|
Bad Battery
| Reasons why the bad battery light is on: 1 ). Repair has failed. 2 .72Hr
Timing function: If the battery has not been fully charged within 72 hours,
the icon is on; the reasons may be: 1. The battery capacity is too large. 2.
The battery is broken, you need to find a professional to check the battery .
| **Over Temperature| When the internal temperature of the charger
is higher than 85°C, the output current is automatically reduced. Stop
electricity and Over temperature indicator ml blinks when the temperature
is higher than 100°c .
| Re ve rse Connection Protection| When the
charger and battery are connected inversely , reverse**
connection indicator blinks: Although not damage the charger and battery, but
does not charge, please connect correctly.
CHARGING TIME
Bttery Size
(For 30Ah-300Ah)
| Time(hours-h)
---|---
12V| 12V
30Ah| 3.3| 2.3
60Ah| 6.6| 4.5
100Ah| 11| 7.5
160Ah| 17.6| 12
240Ah| 26.4| 18
300Ah| 36| 22.5
| EMPTY BATTERY TO 80% CHARGE| 50% DOD BATTERY TO FULL CHARGR
Read User Manual Online (PDF format)