FUJITSU ASYG07LMCE Split Type Room Air Conditioner Wall Mounted Instruction Manual
- June 15, 2024
- FUJITSU
Table of Contents
ASYG07LMCE Split Type Room Air Conditioner Wall Mounted
SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
Indoor unit ………………………..Outdoor unit
ASYG07LMCE……………… AOYG07LMCE
ASYG09LMCE…………………. AOYG09LMCE
SPECIFICATIONS
ELECTRICAL DATA
INDOOR UNIT | ASYG07LMCE | ASYG09LMCE |
---|---|---|
OUTDOOR UNIT | AOYG07LMCE | AOYG09LMCE |
POWER SOURCE | 230 V 50 Hz Single phase | |
Cooling | CAPACITY | 2.00 kW |
POWER CONSUMPTION | 0.465 kW | 0.65 kW |
EER | 4.30 kW/kW | 3.85 kW/kW |
RUNNING CURRENT | 2.5 A | 3.2 A |
MAXIMUM CURRENT | 6.0 A | 6.0 A |
MOISTURE REMOVAL | 1.0 L/h | 1.3 L/h |
Heating | CAPACITY | 3.00 kW |
POWER CONSUMPTION | 0.685 kW | 0.73 kW |
COP | 4.38 kW/kW | 4.38 kW/kW |
RUNNING CURRENT | 3.3 A | 3.5 A |
MAXIMUM CURRENT | 7.5 A | 7.5 A |
DIMENSIONS
INDOOR UNIT H x W x D | 270 x 870 x 204 mm |
---|---|
OUTDOOR UNIT H x W x D | 535 x 663 x 293 mm |
WEIGHT
INDOOR UNIT Net / Shipping | 8.5 kg / 11 kg |
---|---|
OUTDOOR UNIT Net / Shipping | 21 kg / 25 kg |
FAN MOTOR AND FAN REVOLUTION
INDOOR UNIT’S Discrimination | MFD-12CYBL |
---|---|
OUTDOOR UNIT’S Discrimination | MFE-22AVAL |
INDOOR UNIT
Cooling| High| 1,320 rpm
Medium| 1,160 rpm
Low| 930 rpm
Quiet| 680 rpm
INDOOR UNIT
Heating| High| 1,320 rpm
Medium| 1,160 rpm
Low| 980 rpm
Quiet| 710 rpm
OUTDOOR UNIT| Cooling| 730 rpm
Heating| 650 rpm
AIRFLOW
INDOOR UNIT
Cooling| High| 750 m3/h
---|---|---
Medium| 640 m3/h
Low| 480 m3/h
Quiet| 310 m3/h
INDOOR UNIT
Heating| High| 750 m3/h
Medium| 640 m3/h
Low| 520 m3/h
Quiet| 330 m3/h
OUTDOOR UNIT| Cooling| 1,670 m3/h
Heating| 1,470 m3/h
NOISE LEVEL
INDOOR UNIT
Cooling| High| 43 dB
---|---|---
Medium| 40 dB
Low| 32 dB
Quiet| 21 dB
INDOOR UNIT
Heating| High| 43 dB
Medium| 38 dB
Low| 33 dB
Quiet| 22 dB
OUTDOOR UNIT| Cooling| 45 dB
Heating| 45 dB
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE | Hermetic type, 4 pole, 3 phase,DC inverter motor, Rotary |
---|---|
DISCRIMINATION | 5SS072XHA01 |
WEIGHT (with oil) | 6.0 kg |
PRECHARGED REFRIGERANT | 700 g |
REFRIGERANT TYPE | R410A |
Pipe length
FULL CHARGE| 15 m| 700 g
20 m| 800 g
ADDITIONAL CHARGE| 20 g/m
MAXIMUM PIPING HEIGHT| 15 m
DIMENSIONS
INDOOR UNIT OUTDOOR UNIT
REFRIGERANT SYSTEM DIAGRAM
Refrigerant pipe
diameter
Liquid : 1/4″ (6.35 mm)
Gas : 3/8″ (9.52 mm)
CIRCUIT DIAGRAM
Models : ASYG07LMCE / AOYG07LMCE
ASYG09LMCE / AOYG09LMCE
PCB CIRCUIT DIAGRAM
CONTROL UNIT
ASYG07LMCE : EZ-0124CHSE
ASYG09LMCE : EZ-0120MHSEI NVERTER ASSEMBLY
AOYG07LMCE : EZ-0122CHUE
AOYG09LMCE : EZ-012PHUE
ERROR DETECTION
If you use a wireless remote control, the lamp on the photo detector unit will
output error codes by way of blinking patterns.
If you use a wired remote control, error codes will appear on the remote
control display. See the lamp blinking patterns and error codes in the table.
An error display is displayed only during operation.
Troubleshooting with the indoor unit display Troubleshooting with the Wired Remote Control
Display (Option)
If an error occurs, the following display will be shown.
(“Er” will appear in the set room temperature display.)
Error display| Wired remote controller Error code|
Description
---|---|---
OPERATION
lamp (green)| TIMER
lamp (orange)|
ECONOMY
lamp (green)
● (1)| ● (1)| | | Serial communication error
● (1)| ● (2)| | | Wired remote controller communication error
● (1)| ● (5)| | | Check run unfinished
● (2)| ● (1)| | | Unit number or Refrigerant circuit address setting error
[Simultaneous Multi]
● (2)| ● (2)| | | Indoor unit capacity error
● (2)| ● (3)| | | Combination error
● (2)| ● (4)| |
| • Connection unit number error (indoor slave unit) [Simultaneous Multi] •
Connection unit number error (indoor unit or branch unit) [Flexible Multi]
● (2)| ● (7)| | | Master unit, slave unit set-up error [Simultaneous Multi]
● (3)| ● (2)| | | Indoor unit PCB model information error
● (3)| ● (5)| | | Manual auto switch error
●(4)| ● (1)| | | Room temp. sensor error
● (4)| ● (2)| | | Indoor unit Heat Ex. Middle temp. sensor error
● (5)| ● (1)| | | Indoor unit fan motor error
● (5)| ● (3)| |
| Drain pump error
● (5)| ● (7)| | | Damper error
● (5)| ● (8)| | | Intake grille error
● (5)| ● (15)| | | Indoor unit error
●(6)| ● (2)| |
| Outdoor unit main PCB model information error or communication error
● (6)| ● (3)| | | Inverter error
● (6)| ● (4)| |
| Active filter error, PFC circuit er- ror
● (6)| ● (5)| | | Trip terminal L error
● (6)| ● (10)| | | Display PCB microcomputers communication error
● (7)| ● (1)| | | Discharge temp. sensor error
● (7)| ● (2)| | | Compressor temp. sensor error
● (7)| ● (3)| | | Outdoor unit Heat Ex. liquid temp. sensor error
● (7)| ● (4)| | | Outdoor temp. sensor error
● (7)| ● (5)| | | Suction Gas temp. sensor error
● (7)| ● (6)| | | • 2-way valve temp. sensor error
• 3-way valve temp. sensor error
● (7)| ● (7)| | | Heat sink temp. sensor error
● (8)| ● (2)| | | • Sub-cool Heat Ex. gas inlet temp. sensor error
• Sub-cool Heat Ex. gas outlet temp. sensor error
● (8)| ● (3)| | | Liquid pipe temp. sensor error
● (8)| ● (4)| | | Current sensor error
● (8)| ● (6)| | | • Discharge pressure sensor error
• Suction pressure sensor error
• High pressure switch error
● (9)| ● (4)| | | Trip detection
● (9)| ● (5)| | | Compressor rotor position detection error
● (9)| ● (7)| | | Outdoor unit fan motor error
● (9)| ● (9)| | | 4-way valve error
● (10)| ● (1)| | | Discharge temp. error
● (10)| ● (3)| | | Compressor temp. error
● (10)| ● (4)| | | High pressure error
● (10)| ● (5)| | | Low pressure error
● (13)| ● (2)| |
| Branch boxes error [Flexible Multi]
Display mode
● : 0.5s ON / 0.5s OFF
◊ : 0.1s ON / 0.1s OFF
( ) : Number of flashing
PARTS
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Ref.
| Description|
Part number
---|---|---
1| Remote Control| 9319208008
2| Remote Control Holder| 9318912005
3| Bracket Panel| 9332882025
4| Electric Filter Holder| 9332911008
5| Air Clean Filter Assy| 9317250009
6| Air Filter| 9332875010
7| Screw Cap| 9309002074
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Ref.
| Description|
Part number
---|---|---
11| Wire Cover| 9333504018
12| Louver Assy| 9333353043
13| Diffuser Assy| 9332998085
14| Front Panel Sub Assy (FUJITSU)| 9333525051
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Front panel sub assy
Ref.
| Description|
Part number
---|---|---
21| Intake Grille Assy| 9333526010
22| Front Panel C| 9333497020
23| Under Cover| 9333503011
24| Front Panel Cover R| 9333502014
25| Front Panel R| 9333500003
26| Front Panel Cover L| 9333501017
27| Front Panel L| 9333499000
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Control box
Ref. | Description | Part number |
---|---|---|
31 | Control Box | 9332892000 |
32 | Main PCB (ASYGO7LMCE) | 9709427033 |
32 | Main PCB (ASYGO9LMCE) | 9709427019 |
33 | Terminal | 9900720001 |
34 | Display Assy | 9709430019 |
35 | Room Thermistor Holder | 9332868005 |
Thermistor Assy | 9900930011 |
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Evaporator
Fan
Ref.
| Description|
Part number
---|---|---
41| Evaporator Total Assy| 9332989090
42| Fan Motor| 9603269005
43| Crossflow Fan Assy| 9316830004
44| Bearing C Assy| 9306628017
45| Casing Assy| 9333009001
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Casing assy
Ref.
| Description|
Part number
---|---|---
51| Casing| 9332890006
52| Casing Cover F| 9332909005
53| Casing Cover B| 9332908008
54| R and L Louver| 9332891003
55| Fan Guard| 9332905007
56| Drain Cap| 9316177017
57| Drain Hose Assy| 9316904002
INDOOR UNIT
ASYG07LMCE
ASYG09LMCE
Casing assy
Ref.
| Description|
Part number
---|---|---
61| Motor Holder L/R| 9332859003
62| Cable Guide| 9332903003
63| Step Motor| 9900790004
64| Step Motor| 9900790011
PARTS
OUTDOOR UNIT
AOYG07LMCE
AOYG09LMCE
Ref.
| Description|
Part number
---|---|---
1| Protective Net| 9332855005
2| Thermistor Holder| 9332505009
3| Top Panel Assy| 9332977004
4| Front Panel Assy| 9332965001
5| Cabinet Left Assy| 9332962000
6| Emblem| 9319151007
7| Cabinet Right Assy| 9332963007
8| Switch Cover A Assy| 9332964011
9| Switch Cover B| 9332843002
10| Fan Motor| 9603074043
11| Propeller Fan| 9309909014
12| Drain Assy| 9332574005
13| Motor Bracket Assy| 9332583021
OUTDOOR UNIT
AOYG07LMCE
AOYG09LMCE
Ref.
| Description|
Part number
---|---|---
21| Reactor Assy (AOYG07LMCE)| 9900872014
21| Reactor Assy (AOYG09LMCE)| 9900787028
22| PCB Holder| 9332506013
23| Main PCB with Terminal (07)| 9709434147
23| Main PCB with Terminal (09)| 9709434031
24| Heat Sink B| 9332522006
—| Thermistor Assy| 9900901011
—| Thermistor| 9900880019
OUTDOOR UNIT
AOYG07LMCE
AOYG09LMCE
Ref.
| Description|
Part number
---|---|---
31| Condenser Total Assy| 9332924008
32| Compressor Assy| 9317083034
33| Solenoid| 9970079030
34| 4-way Valve Assy| 9333012001
35| Expansion Valve Coil| 9970137013
36| Pulse Motor Valve Sub Assy| 9333023007
ACCESSORIES
INDOOR UNIT OUTDOOR UNIT
1611G4556
Documents / Resources
|
FUJITSU ASYG07LMCE Split Type Room Air Conditioner Wall
Mounted
[pdf] Instruction Manual
ASYG07LMCE, AOYG07LMCE, ASYG09LMCE, AOYG09LMCE, ASYG07LMCE Split Type Room Air
Conditioner Wall Mounted, Split Type Room Air Conditioner Wall Mounted, Room
Air Conditioner Wall Mounted, Air Conditioner Wall Mounted, Conditioner Wall
Mounted, Wall Mounted, Mounted
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>