Rohnson R-031 Glass Convection Heater with Wi-Fi Instruction Manual

June 15, 2024
Rohnson

GLASS CONVECTION HEATER
WITH Wi-Fi

INSTRUCTION MANUAL
Model No.: R-031
This product is only suitable for well insulated spaces or
occasional use.

R-031 Glass Convection Heater with Wi-Fi

Introduction
To get the most out of your new heater, please read through these instructions and the attached safety regulations before use. Please also save the instruction manual in case you need to remind yourself of the heater’s functions at a later  date.

Technical Specification

Details R-031
Voltage 220-240V~
Frequency 50-60Hz
Power 1000/2000W
IP Waterproof IP24
Remote control Included

Important
Before plugging the unit into the mains, ensure by visual inspection that the unit is intact and has not suffered any damage during transit.

Caution
The appliance must be always placed on a flat and stable surface.
In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.

For your own safety

  1. Read all instruction before using the heater.
  2. Only connect the heater to a single-phase socket with a mains voltage as specified on the rating plate.
  3. Do not leave your home while the appliance is in function: ensure that the switch is in OFF (0) position and the thermostat is in minimum position. Always unplug the appliance.
  4. Keep combustible material such as furniture, cushions, bedding, paper, clothes, curtains etc. at least 100cm away from the heater.
  5. Do not hand anything on or in front of the heater.
  6. Always use the heater in an upright position.
  7. Do not place the heater against walls, furniture, curtains, etc.
  8. Do not use the appliance in rooms less than 4m² area.
  9. Always unplug the heater when not in use. Do not pull the cord to unplug the heater.
  10. Keep the air inlet and outlet free from objects at least 1m in front and 50cm behind the heater.
  11. Do not install the heater immediately below a socket- outlet.
  12. Do not let animals or children touch or play with the heater. Pay attention the air outlet gets hot during operation.
  13. Do not cover. If covered, there is the risk of overheating.
  14. Do not use this heater in the immediate surroundings of a bath, a shower or a swimming pool.
  15. Do not use the heater in the rooms containing explosive gas inflammable solvents, varnish or glue.
  16. Keep the heater clean. Do not allow any objects to enter any ventilation or exhaust opening as this may cause electric shock, or fire or damage to the heater.
  17. If the heater has been dropped or damaged it should not be used until it has been inspected by a qualified service center.
  18. Close supervision is necessary when the heater is being used  by or near children, persons suffering from any physical impairment or pets.
  19. Do not use to dry clothes or any fabric.
  20. Do not use the heater to dry your laundry. Never obstruct the intake and outlet grilles (danger of overheating).
  21. Do not move the appliance while it is functioning in order to avoid overheating with the additional risk of fire.
  22. If any part of the heater or supply cord becomes damaged, it must be replaced by a qualified electrician. In order to avoid a hazard.
  23. The heater must not be located immediately below a socket- outlet.
  24. Do not use this heater with a programmer, timer or any other device that switches the heater on automatically, since a fire risk exists if the heater is covered or positioned incorrectly.
  25. Do not use this heater if is has been dropped.
  26. Do not use if there are visible signs of damage to the heater.
  27. Use this heater on a horizontal and stable surface.
  28. WARNING: Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
  29. WARNING: To reduce the risk of fire, keep textiles, curtains or any other flammable material a minimum distance of 1m from the air outlet.
  30. WARNING: In order to avoid overheating, do not cover the heater.
  31. Do not leave the heater switched on when leaving your home or going to sleep.
  32. Children should be supervised to ensure that they do not play with the appliance.
  33. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning  use of the appliance in a safe way and understand the hazards involved.
  34. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  35. Children of less than 3 years should be kept away unless continuously supervised.
  36. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction   concerning use of the appliance in a safe way and understand the hazards involved.
  37. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
  38. Do not leave unattended when plug in to the mains supply.
  39. CAUTION — Some parts of this product can become very hot and cause burns. Particular attention must be given where children and vulnerable people are present.
  40. The maximum radioelectric power in the frequency bands in which the radio equipment operates is 18dBm and 2,4GHz.

DESCRIPTION OF THE SYMBOLS

**** In accordance with European directives applicable to this product
WARNING: To avoid overheating, do not cover
CAUTION: Parts of this unit may become hot and cause burns. Be very

vigilant and avoid touching the hot parts.

PECIFICATION

Model: GH-1901-20-W/ R-031
Standard: IEEE 802.11 b/g/n
Antenna Type: PCB Antenna
Frequency WIFI: 2.400~2.4835GHz
Maximum Transmitted Power: 18dBm Max
Dimension: 16±0.35 mm (W)×24±0.35 mm (L) ×2.9±0.15 mm (H).
Operation Temperature: minimum value: -20 ℃, max value: 85℃
Power Input: 220-240V AC, 50-60Hz

Producer: Zhongshan SEEMAX Electrical Appliance Co., Ltd
Address: 4th floor, Building B, No.13, Dongrui Third Road, Xiaolan
Town, Zhongshan City, Guangdong province.
Τηλ: +86-757-29960488, Fax:+86-757-29960487

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, Zhongshan SEEMAX Electrical Appliance Co., Ltd,
declares that the radio equipment type of R-031 is in compliance
with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.vassilias.gr

Caution
Some parts of the heater can become very hot and cause burns. Do not touch hot surfaces.
Particular attention has to be given where children and vulnerable people are present.

Note
These heaters are intended for domestic use only. They can be used as both portable appliance and wall mounting appliance.

ASSEMBLY

Unpack the heater and the accessories.

FREE STANDING USE

  1. Place the unit upside down and fix the right and left feet with screw (Image 1).

  2. Place the unit upright and check if the feet is fixed properly before use (Image 2)

WALL MOUNTED USE

Instruction for fixing the heater on wall:

  • Take out 1# bracket (2pcs)/2# bracket(1pc)/ST4*14(4pcs) screws of the accessories bag.

  • Install 1# bracket at the back of the appliance by fixing the 4 screws (see picture).

  • Remove the middle one screw at the bottom of appliance and install 2# bracket here by fixing this one screw.

  • Installing range for 1# bracket:630mm

  • Use 6# pressing drill to drill out 1# bracket mounting holes on the wall, fit the holes with colloidal particles within the accessories bag, then fixing screws ST4*36 on the wall.
    (Note: Screw should appear 3-5mm)

  • Hang the appliance on the wall, mark the 2# bracket installation hole with pencil.

  • Remove the appliance, use 6# pressing drill to drill out mounting holes on the wall, fit the holes with colloidal particles.

  • Hang the appliance on the wall, fixing 2# bracket with screws ST4*36.

  • Wall-mounted installation finished.

Remote control

Please use 1 commercially available CR2025 button battery
(battery is included).

  1. Pull out the battery box by pressing inside the groove of the battery box on the back of the remote control with your fingernail. Release CR2025
  2. open the battery box

OPERATION

Place the heater on a stable and horizontally even ground.

Plug in power supply, press ON/OFF button (at the bottom of right housing) to connect power. Press it again to disconnect power.

Symbol Meaning
Working at Full power 2000W
Working at 1000W
Anti-frost function
Window open detection function
WiFi connection
d1,d2,d3,d4,d5,d6,d7 Mon. Tue. Wed. Thur. Fri. Sat. Sun.
P1,P2,P3,P4,P5 Factory default program
UP Customized program setting

Touch once to switch on the appliance. Touch again to switch it off.

  1. Set Current Day and Time:
    When appliance is switch on, long touch for 3 seconds to activate current day setting.
  1. Screen will display d1 and it flashes, then touch to set Day of the week among d1, d2, d3, d4, d5, d6, d7 in cycle.
    Touch once to confirm the current day setting.
  2. Then appliance enter time setting. Hour icon flashes, touch to set current hour among 00-23 in cycle. Touch once to confirm hour.
  3. Then follow the same way to set minute among 00-59. Finally Touch once to confirm setting.
    After setting finish, touch once in standby mode to check if the current day and time setting is correct. Screen will automatically show “Day” – “Hour” – “Minutes” in turns within1 second each, then switch back to temperature display.
    For exampe, when your current day setting is Wed. 12:45 a.m., screen will show d3, 12, 45 in turns accordingly.
    Note: At the first usage, icon will keep flashing to remind user to set current day and time. It will not stop flashing until current day and time is set. Please finish the setting before any other operation.
  1. Power Setting
    When appliance is switch on, screen display and appliance work at full power 2000W. You may touch button to switch between 2000W and 1000W.

  2. Temperature Setting
    After power setting, touch to activate temperature setting and choose among 5-40℃. It will save automatically in 5 seconds when no further operation is conducted.
    Note:

  1. When room temperature is found to reach the set temperature, appliance will stop heating. When room temperature is found to drop 1℃ below set temperature, appliance will recover heating.
  2. In anti-frost working mode, temperature setting is not allowed.
  1. Mode Switch
    When appliance is switch on, touch to select program mode among PI, P2, P3, P4, P5, UP in cycle.
    – P1, P2, P3, P4, P5 are factory default program and cannot be changed
    – UP is customized program for end-user to set working period and mode upon their habit.
    Table below shows factory default program P1, P2, P3, P4, P5

One
Week| mode| Working mode| Remark
---|---|---|---
Anti-frost| Comfort| Anti-frost| comfort| Anti-frost| comfort| Anti-frost
1-7| PI| | 00:00-2
4:00| | | | | | All day comfort, applicable for everyday use  continuously
1-5| P2| 00:00-06:3
0| 06:30-0
8:30| 08:30-17:0
0| 17:00.2
2:30| 22:30-24:0
0| | | Applicable for family  who work in weekdays and be off  at weekends
6.7| 00:00-07:3
0| 07:30-1
0:00| 10:00-12:0
0| 12:00-1
4:00| 14:00-17:0
0| 17:00-2
2:30| 22:30-24:0
0
1-5| P3| 00:00-06:0
0| 06:00-1
7:00| 17:00-24:0
0| | | | | Applicable in office  where is occupied in week days and empty  in weekends
6-7| 00:00-24:0
0| | | | | |
1-7| P4| 00:00-06:0
0| 06:00.2
2:00| 22:00.24:0
0| | | 1| | Applicable for commercial place  where is occupied all  the way
1-7| P5| 00:00-24:
00| | | | | | | All anti-frost.
applicable for family  who go out for a long time

  • *Anti-frost: appliance keep room temperature at default 5℃ to prevent frost.

  • *Comfort: upon your need to set power and temperature. (follow step 2&3)

    1. Timer Setting
      In P1 working mode, touch twice quickly to activate timer setting. Icon flashes on the screen, then touch to set timer reverse among 0 to 24 hours. It will save automatically in 5 seconds after setting. Icon stop flashing and appliance  starts count down to turn off.
      Touch twice quickly again to cancel timer reverse setting, icon become gray.
      Note: Touh , switch to other mode, timer reverse will not work, icon become gray

    2. Customized program, UP Setting
      When appliance is switch on,

  1. Touch button and choose UP mode, then touch button to activate customized setting to set one (or up to three) working period in comfort mode.
  2. Screen displays d1 to begin Monday setting, touch once to activate the 1 st working period setting, screen display 1 and icon flashes. Touch once again to select start time among 0 to 23. Then touch button to confirm setting, screen will switch to finish time setting, touch to choose and touch button to confirm. Appliance will automatically enter into the 2 nd working period setting, the screen will display 2 and icon flashes. In the same way, you may set  the 2 nd and the 3 rd working period.
    Note:
    – Touch button at first instead of can skip the steps to keep the appliance in Anti-frost function.
    – In comfort mode working time, you may touch to switch power setting among (2000W) and (100W).
    – In spite of the set period, appliance will display and keep the room temperature at anti-frost mode at 5℃.
  3. Touch button to confirm every setting, when d1 setting is finish, it will automatically turn to d2. In the same way, you may set d2, d3, d4, d5, d6 and d7.
  4. When all setting is confirmed, icon stop flashing.
  5. Long touch PROG button for 3 seconds to check UP mode setting,
    – touch button each time to check each setting in turns, for example, d1 – 1st working start time – 1st working finish time and so on.
    – touch button to choose among d1 to d7. Press to activate the corresponding day’s working peroid setting.
    – it will quit automatically when no operation within 2 minutes.
  1. Child Lock Function
    When appliance is switch on, long touch at the same time for 3 seconds to activate child lock function, screen will show [ ] after setting and will recover to original display in 5 seconds. No button will be active during it. Once button is touch, screen will flashes [ ] and recover to original display in 5 seconds. Long press at the same time for 3 seconds again to cancel child lock function

  2. Window Open Detection Function:
    When appliance is switch on, touch once to activate window open detection,icon flashes on the screen, touch  again to cancel the setting, icon disappear.
    In window open detection mode, when appliance is heating, but room temperature is found to drop 5°C in 10 minutes, appliance will consider the window may open and start detection. In the next 30 minutes, if room temperature  hasn’t raised, appliance will consider the window is open and stop heating. At the same time, icon stop flashing and keep lighting to remind user to close the window.
    After closing the window, touch to recover orginal operation , icon flashes again.

  3. WIFI
    When appliance is switch on and WIFI module is detected, long press 3s to activate network connection, the indicator lights up and flashes to prompt network connection. After the network connection is successful, indicator lights up and stays on. In the network connection state, long press  3s to turn off WIFI function, and indicator light will resume flashing.
    Note:
    – After the network connection is successful, the appliance powers on again after power failure, WIFI function will not turn on(users can not control the appliance by app). In power-on state, touch twice continuously to turn on WIFI function, indicator lights up and stays on. (then users can control the appliance by app).

  4. Reset
    Quickly touch and twice to reset the appliance.

MAINTENANCE

WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING
CLEANING: IMPORTANT! DO NOT IMMERSE HEATER IN WATER! DO NOT TRY TO DISASSEMBLY THE HEATER. DO NOT REMOVE GRILL.
CAUTION: Do not use gasoline, benzene, thinner, harsh cleaners, etc.
as they will damage the Heater. NEVER use ALCOHOL OR SOLVENTS.
STORAGE: Store the heater with these instructions in the original carton in a cool, dry place

WARNING : The Main Power Switch and the On/Off switch should not be used as the sole means of disconnecting power. Always unplug the power cord before servicing or moving the unit.

WARNING : To avoid danger of electric shock, unplug from outlet when not in use and before cleaning. If the supply cord is damaged, it must be replaced by the manufactory or its service agent or a similarity qualified person in order to
avoid a hazard.

DETAILS FOR Wi-Fi CONNECTIVITY

Please scan QR code to download Rohnson APP for Android as below.
APP Store for IOS mobile device

https://smartapp.tuya.com/rohnson

Connection by WIFI

  1. Use your phone to scan the QR code above or search“Rohnson” App in Play store or App store. Download and instalthe Rohnson App.
  2. Select Register. Then, select your country, enter email and tap“Continue” to get a message containing verification on code.
  3. Enter the verification on code in the message and tap“Login” tologin the App.
  4. Please activate the Bluetooth function on your mobile phone.
  5. Press the safety switch at the side of the unit, then press theon/off switch to switch on the product and make sure the product isin WIFI covered environment. The Wi-Fi indicator light will rapidly blinks. If the indicator light do not  rapidly blinks, please press “ ” button for 5 seconds and the Wi-Fi signal will rapidlyblinks, then go to the App, tap “add device” at the bottom.

The product will be added successfully In case you see this message, please check the three possible reasons and retry

Now, the unit is off. Press the on/off switch to turn the unit on. Then, the unit is on. You can adjust your desired temperature from 5-40°C.

Select Mode to set your desired heating mode. P1, P2, P3, P4, P5 are factory default program and cannot be changed.
– UP is customized program to set working period and mode upon your needs. If you want to change the UP program, you have to do it manually on the device.

Select Gear to choose between 1000W and 2000W.

You can select the desired timer to turn the unit off (1-24h)

Select Settings to turn on/off the child lock and window open detection function.

Select this button for more options on your device.
You can change your product’s name, check device info or share your device with other people. Choose device sharing, add sharing, share with the Account Rohnson or other options. You can share the product with maximum 20 people.

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCTIN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC.

At the end of its working life, the product must not be disposed of asurban waste. It must be taken to a special local authority differentiated waste collection center or to a dealer providing thisservice. Disposing of a household appliance  separately avoidspossible negative consequences for the environment and health,deriving form inappropriate disposal and enables the constituentmaterials to be recovered to obtain significant savings in energyand resources. As a  reminder of the need to dispose of householdappliances separately, the product is marked with a crossed- outwheeled dustbin.

Information requirements for electric local space heaters

Model number: R-031

Item| Symbol| Value| Unit| | Item| Symbol| Value| Unit
---|---|---|---|---|---|---|---|---
Heat Output| | Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output| P nom| 2,0| kW| | Manual heat charge control, with integrated thermostat| No
Minimum heat output (indicati ye)| P min| 1,0| kW| | Manual heat charge control with room and/or
outdoor temperature feedback| No
Maximum continuous heat output| P max.c| 2,0| KW| | Electronic heater charge control with room and/or
outdoor temperature feedback| No
Auxiliary electricity consumption| | Fan assisted heat output| No
Atnominal heat output| Cl max| 0| kW| | Type of heat output / room temperature control (select one)
Atminimum heat
output| el min| 0| kW| | single stage heat output and no room temperature control| No
Instandby mode| e/ SB| 0.000 2| kW| | Two or more manual stages, no room temperature control| No
| | | | | with mechanic thermostat room temperature control| No
| | | | | with electronic room temperature control| No
| | | | | electronic room temperature control plus day timer| No.
| | | | | electronic room temperature control plusweek timer| Yes
| | | | |  Other control options (multiple selections possible)
| | | | | room temperature control, with presence detection| No
| | | | | room temperature control, with open window detection| Yes
| | | | | with distance control option| Yes
| | | | | with adaptive start control| No
| | | | | with working time limitation| Yes
| | | | | with black bulb sensor| No

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals