AIPHONE JOW-2D Two Door Adaptor
Product Information
The JOW-2D is a two-door adaptor designed for use with the JO Series. It
allows for monitoring of door 1 by the master station.
Please note that only the JO-DV door station can be purchased separately.
Wiring
To properly wire the JOW-2D, follow the instructions below:
For JO-1MDW / JO-1MD / JO-1FD:
Connect A1 and A2 to the corresponding terminals on the master station. Connect L and L to the power supply (PS-1820UL). For door 1, connect JO-DA/JO- DV/JO-DVF to A1 and A2. For door 2, connect JO-DV to A1 and A2.
For Strike & Power
- For door 1, connect A1 and A2 to the strike and power terminals.
- For door 2, connect A1 and A2 to the strike and power terminals as well.
For Master, Door 1, and Door 2:
Connect A1, A2, and L to the corresponding terminals on the master station, door 1, and door 2. Connect the door station line and door release line as required.
Specifications
- Power: DC18V
- Current consumption: Not specified
- Relay Outputs: Not specified
- Operating Temperature: Not specified
- Mounting: Not specified
- Dimensions: Not specified
Frequently Asked Questions
Can I monitor both doors with the master station?
- No, only door 1 can be monitored by the master station.
Can I purchase the JO-DV door station separately?
- Yes, the JO-DV door station can be purchased separately.
INSTRUCTIONS
The JOW-2D is an adaptor for the JO Series video intercom system that will allow two video door stations to be on the system. The adaptor has inputs for two JO video door stations and outputs to control door release for each of those door stations. When either door station calls in, that image will be displayed on the inside station(s). The person inside answers the call, and when pushing the door release button, only the associated door release mechanism will trigger. If one door station is in use, the call button on the other door station will not activate a call-in.
Note: Only door 1 can be monitored by the master station.
WIRING
SPECIFICATIONS
- Power: 18V DC (share PS-1820UL with JO master station)
- Current consumption: 100mA (max), 18mA (standby)
- Relay Outputs: When using JO-1MDW only: 24V DC, 1A When using JO-1MD or JO-1FD: 24V DC, 500mA
- Operating Temperature: 32° ~ 104° F (0° ~ 40°C)
- Mounting: Mount to W-DIN11 (sold separately)
- Dimensions: 4-¼” H x 4-13⁄16″ W x 2-⅜” D