Safety Instruction
Please ensure that the using power voltage matches with the supply voltage of gate opener (AC110V or AC220V); kids are forbidden to touch the control devices or the remote-control unit. The remote-control unit is controlled by a single-button mode or three-button mode (please refer to the instructions of the remote control in accordance with the actual gate opener type). The indicator light on the remote-control unit will flicker when the button on it is pressed. The main engine and gate can be unlocked by disengagement wrench and the gate can move with manual operation after disengagement. Please ensure that no one is around the main engine or gate when the switch is operated and it is usually demanded to examine the stability of installation. Please temporarily stop using if the main engine needs repair or regulation. The installation and maintenance of the products must be carried out by professionals.
Packing List (standard)
Packing list (Optional)
Technical parameters
Model | SLG52801 | SLG52802 | SLG52803 | SLG52804 |
---|---|---|---|---|
Power supply | 110VAC/50Hz | 110VAC/50Hz | 220VAC/50Hz | 220VAC/50Hz |
Motor power | 280W | 280W | 280W | 280W |
Gate moving
speed
| 13m/min| 13m/min| 13m/min| 13m/min
Maximum weight
of gate
| 600Kg| 600Kg| 600Kg| 600Kg
Remote control
distance
| ≥50m| ≥50m| ≥50m| ≥50m
Remote control
mode
| Single button mode
/ Three button mode
| Single button mode
/Three button mode
| Single button mode
/Three-button mode
| Single button mode
/Three button mode
---|---|---|---|---
Limit switch| Magnetic limit switch| Spring limit switch| Magnetic limit
switch| Spring limit switch
Noise| ≤56dB| ≤56dB| ≤56dB| ≤56dB
Output torque| 14N.m| 14N.m| 14N.m| 14N.m
Output shaft
height
| 46mm| 46mm| 46mm| 46mm
Frequency| 433.92 MHz| 433.92 MHz| 433.92 MHz| 433.92 MHz
Working
temperature
| -20°C – +70°C| -20°C – +70°C| -20°C – +70°C| -20°C – +70°C
Package weight| 10.10Kg| 10.10Kg| 10.10Kg| 10.10Kg
Installation
SLG5280X sliding gate opener is applicable to gate weight less than 600kg, and the length of the sliding gate should be less than 8m. The drive mode adopts the gear and rack transmission. This gate opener must be installed inside the enclosure or yard for protection.
Installation Drawing
- Gate opener;
- Wireless keypad
- Gate;
- Infrared sensor;
- Alarm lamp
- Safety stop block
- Gear rack
- Remote control
Size of main engine and accessories
Size of the main engine
Size of the mounting plate
Installation procedures
Preparation work before installation
Please ensure that the sliding gate is correctly installed, the gate rail is
horizontal, and the gate can glide back and forth smoothly when moved by hand
before installing the gate opener.
Cable installation Please bury the motor & power cable and controlling cable
with a PVC tube, and use two PVC tubes to bury (the motor & power cable) and
(controlling cable) separately, so as to guarantee normal operation of the
gate opener and protect the cables from damage.
Concrete pedestal
Please cast a concrete pedestal with the size of 400mm x 250mm and a depth of 200mm in advance, so as to firmly install the SLG5280X gate opener. Please verify whether the distance between the gate and gate opener is suitable before casting the pedestal. Embedded screws
Main engine installation
- Dismantle the plastic housing on the main engine before installation and keep relevant fasteners properly;
- Please prepare the power line for connecting the mounting plate and main engine (the number of power supply cable cores shall not be less than 3 PCS, the sectional area of the cable core shall not be lower than 1.5mm² and the length shall be determined by users according to the field situation) due to different installation environments;
- Please unlock the main engine before installation, the unlock method is: to insert the key, and open the manual release bar till it rotates by 90° as shown in Figure 5. Then turn the output gear and the gear can be rotated easily;
Gear rack installation
- Fix the mounting screws to the rack.
- Put the rack on the output gear, and weld the mounting screw to the gate (each screw with one solder joint first).
- Unlock the motor and pull the gate smoothly.
- Please check whether there is a fit clearance between the rack and output gear, as shown in Figure 7.
- Weld all the mounting screws to the gate firmly.
- Make sure that all racks on the same straight line.
- Pull the gate after installed, and make sure the entire trip is flexible no stuck.
The fit clearance of the output gear and the rack is shown in Figure 7 below
Warnings
- To ensure safety, install safety stopblocks on both ends of the rails to prevent the gate out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place and whether it has the function of preventing the gate from moving out of the rail and out of the safety range.
- Please ensure that the main engine and its components have good mechanical properties, and the gate can operate flexibly when moved by hand before installing the main engine.
- In this product, one control can drive one main engine only, otherwise, the control system will be damaged.
- Earth leakage circuit breaker must be installed where the gate movement can be seen, and the minimum mounting height is 1.5m to protect it from being touched.
- After installation, please check whether the mechanical property is good or not, whether gate movement after manual unlocking is flexible or not, and whether the infrared sensor (optional) is installed correctly and effectively.
Limit switch adjustment
Spring limit switch – The installation site of the spring limit switch is shown in Figure 8:
The installation of spring limit switch stop block is shown in Figure 9:
Magnetic limit switch – The installation site of the magnetic limit switch is shown in Figure 10:
The installation of the magnetic limit switch block is shown in Figure 11:
Figure 11
Note: The default setting is right-side mounting. (According to the
actual situation, please refer to the “Note” of section 5.1 to adjust)
Safety Instruction
- For security, please read instructions carefully before initial operation; making sure that the power is off before connection.
- Please clear the memory before the initial operation. (Ref.: Erasing ALL learned/memorized Transmitters)
- Do not learn the remote control when the motor is operating in order to avoid mis-operation.
- The received signal may be interfered by other communication devices. (e.g. the wireless control system with the same frequency range)
- his product is only used for equipment that will not cause life or property hazards when a breakdown happens or its security risks have been already eliminated
- It should be applied in a dry indoor place or in an electric appliance place.
Technical Index
- Working voltage: 220VAC/110VAC,50Hz/60Hz
- Temperature range: -20℃ to 60℃
- Loading capacity: 1 HP 220VAC; 0.5 HP 110VAC
- Built-in fuse: electric circuit(0.5A); Motor(10A),Please exchange appropriate fuse accoding to loading capacity
- Soft-start time:1S. Soft-stop time = 127s – quick running time
- Quick running time: Adjustable from 3s to 120s —-PT3 is to set up 2.7 Frequency: 433.92MHz
- Transmitter stored: 30PCS
- Output voltage: AC24V
- Output with electric lock: normally closed contact
- Output with flash lamp: AC220V/AC110V
- External switch (open, stop, close in a loop)
- External limit ( DIP8 to select NO and NC)
- External infrared (NC contact)
- Auto close time is adjustable: (5S,10S,30S are optional by using DIP1,DIP2) 2.16 Soft start function is optional by DIP5
- Installation at the left or right side is optional by DIP6.
- Single / three-button control is optional by DIP7
- Size: 1557738mm
- Weight: 333g
Wire connection
Set up
Learning and erasing transmitters by receiver: Press the learning button S3 in the board, LED DL2 is on, and enters into the learning process; Press the same button twice, LED blinks for several times, then off. The learning process is successful. Press the learning button, and continue pressing for 8s until the LED turns off; Release the learning button, LED will be on (about 1s) and then off; the erasing process is successful. (Ignore this step if the transmitter already matches the opener before delivery). The board can learn 30pcs transmitters max.
Self-learning function: Use the transmitter that already has been learned as an old transmitter, press button 1 and button 2 at the same time, and then press button 2 to let it enters into the learning process. Press the same button on the new transmitter twice. The learning process is done. In this way, a new transmitter can be learned without pressing the learning button on the control board.
- Opening/closing limit adjustment: Remote control the door ( or move the door manually ), and adjust the position of the limit device to make sure the door touches the limit switch when opening or closing the door. LED LD6/DL5 in the controller will be off when the limiting device touches the limit switch(The limit switch is NC).
- External infrared switch: Photocell connector connects the NC contact of photocell switch, DL4 LED turns on after the connection, And DL4 LED turns off when blocking out the transmit or receive signal of photocell artificially. The infrared sensor doesn’t react when a door opens and the door will reverse to the limit point if the photocell signal disconnects when the door closes. If no need to use photocell protection, make the connector of the photocell short circuit with a terminated line(the connector is short-circuited when leaving the factory).
- Quick running time set up: It is adjustable from 3s to 120s. Adjust potentiometer PT3 (FastTime) to adjust the quick running time of the motor. It increases the time when adjusting it Clockwise and reduces the time when anti-clockwise
- Motor max running time = Quick running time + Soft stop time = 127 seconds Speed of quick running time is about 0.2 meters per second. The speed of soft stop running time is about 0.06 meters per second.
- Flash lamp: It keeps lighting when opening or closing the door. After the door is fully closed, it will keep lighting for 90 seconds.
Operation Instruction
Three button control process (DIP 7 at OFF position)
Single button control process (DIP 7 at ON position)
Description:
Single button control, press-open-press-stop-press-stop; Only the learned
button is effective in the transmitter, original button is not effective
anymore when a new button has been learned in the same transmitter (For
example, button 1 was learned first, button 2 or 3 has been learned of the
same transmitter afterward, then button 1 was not effective anymore)
Notes
The photocell protection switch shall be examined regularly.
Model difference