AIRTHEREAL C2 Air Curtains User Manual

June 15, 2024
AIRTHEREAL

AIRTHEREAL C2 Air Curtains

Product Information

Specifications

  • Product Name: Air Door C1 & C2
  • Installation: Ceiling
  • Version: 4
  • Installation Heights: 3.5 to 5 meters

Introduction:
The AIR DOOR C1 and C2 units are designed to cover door openings and provide temperature control, environmental separation, and flying insect control when the building’s doors are opened. These units are ceiling-mounted horizontally above the door opening.

General Notes:

  • Please read this manual carefully before attempting to assemble, install, operate, or maintain the product described. Pay attention to all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference.
  • If the supply cord is damaged, it must be replaced by the manufacturer, an authorized agent, or a qualified technician to avoid injury and/or product damage.
  • This appliance is not intended for use by individuals (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given instructions concerning the proper use of the appliance and they are supervised by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Ensure that the product will be installed on a suitable and robust surface capable of sustaining the weight.
  • Ensure that the product is disconnected from the main power supply before removing the guard.
  • This unit is suitable for horizontal ceiling installation above the door’s opening. Installation height according to the model’s specifications.

Installation:

  1. Gently remove all packaging materials and accessories from the interior of the unit before installation and operation to avoid severe unit damage.
  2. Installation work and electrical wiring must be done by a qualified technician(s) by all applicable codes and standards, including fire-rated construction.
  3. The combustion airflow needed for the safe operation of fuel-burning equipment in the area may be affected by the product’s operation. Follow the heating equipment manufacturer’s guidelines and safety standards.
  4. When cutting or drilling into a ceiling, be careful not to damage electrical wiring and other hidden utilities.
  5. Lay the unit on its top with the directional blades pointing up during installation procedures. The unit is fixed on the ceiling with suitable threaded hangers with adjustable nuts and gaskets. The installation must be leveled and securely fastened. (pic. 1/pic. 2).

FAQ:

  • Q: Can I install the Air Door C1 & C2 units on a wall instead of the ceiling?
    A: No, these units are specifically designed for ceiling installation above door openings.

  • Q: What is the recommended installation height for these units?
    A: The recommended installation height is between 3.5 to 5 meters, according to the model’s specifications.

  • Q: Can children operate the appliance without supervision?
    A: No, children should be supervised to ensure they do not play with the appliance.

  • Q: Can I replace the damaged supply cord myself?
    A: No, the damaged supply cord must be replaced by the manufacturer, an authorized agent, or a qualified technician to avoid injury and/or product damage.

INTRODUCTION

AIR DOOR C1 and C2 units are designed to cover door openings, providing both temperature control, environmental separation, and flying insect control when the building’s doors are opened. Installation heights are 3,5 to 5 meters high. The units are ceiling-mounted horizontally above the door opening.

GENERAL NOTES

Please read this manual carefully before attempting to assemble, install, operate, or maintain the product described. Pay attention to all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference.

  1. If the supply cord is damaged, it must be replaced by the manufacturer, an authorized agent, or a qualified technician to avoid injury and/or product damage.
  2. This appliance is not intended for use by individuals (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given instructions concerning the proper use of the appliance and they are supervised by a person responsible for their safety.
  3. Children should be supervised to ensure that they do not play with the appliance.
  4. Ensure that the product will be installed in a suitable and robust surface, capable of sustaining the weight.
  5. Ensure that the product is disconnected from the main power supply before removing the guard.
  6. This unit is suitable for horizontal ceiling installation above the door’s opening. Installation height according to the model’s specifications.

INSTALLATION

  1. Gently remove all packaging materials and accessories from the interior of the unit before installation and operation. Otherwise, severe unit damage can occur.
  2. Installation work and electrical wiring must be done by a qualified technician(s) under all applicable codes and standards, including fire-rated construction.
  3. The combustion airflow needed for the safe operation of fuel-burning equipment in the area may be affected by the product’s operation. Follow the heating equipment manufacturer’s guidelines and safety standards.
  4. When cutting or drilling into a ceiling, be careful not to damage electrical wiring and other hidden utilities.
  5. Lay the unit on its top with the directional blades pointing up during installation procedures. The unit is fixed on the ceiling with suitable threaded hangers with adjustable nuts and gaskets. The installation must be leveled and securely fastened. (pic. 1 / pic. 2).
  6. Properly mount the product for the discharge to be 3 cm above the opening and all obstacles.
  7. For tandem installation or units mounted side by side, allow no more than 15 cm of space between the two units.
  8. All wires must be connected inside the unit. Ensure that the cables do not interfere with the proper placement of the unit.
  9. The unit and any optional accessories must be connected to the junction box with proper voltage, according to the wiring diagram.
  10. If a magnet switch is needed, please conceal the wiring within the wall. Do not leave exposed wiring, as a security precaution.

UNIT PARTS

  Description
1 Ηousing
2 Power cord
3 Mounting kit
4 Left side panel
5 PCB board
6 Fixed plate
7 Front board
8 Wind board
9 Receiver
10 Panel
11 Right side panel
12 Impeller (plastic)
13 Motor bracket
14 Single-shaft motor
15 Double-shaft motor

CONNECTION DIAGRAM

With switch

  • AIR DOOR C1.09 / C1.10 / C1.12
  • AIR DOOR C2.09 / C2.10 / C2.12
  • AIR DOOR C1.15 / C1.18 / C1.20
  • AIR DOOR C2.15 / C2.18 / C2.20

With remote control

  • AIR DOOR C1.09 / C1.10 / C1.12
  • AIR DOOR C2.09 / C2.10 / C2.12
  • AIR DOOR C1.15 / C1.18 / C1.20
  • AIR DOOR C2.15 / C2.18 / C2.20

With magnet switch

  • AIR DOOR C1.09/C1.10/C1.12
  • AIR DOOR C2.09/C2.10/C2.12
  • AIR DOOR C1.15/C1.18/C1.20
  • AIR DOOR C2.15/C2.18/C2.20

Description

AIR DOOR C1.09 / C2.09

N o Description Qty
1 Housing 1
2 Plug & wire 1
3 Mounting kit 4
4 Left side panel 1
5 PCB board 1
6 Fixed plate
7 Front board 1
8 Wind board 1
9 Receiver 1
10 Panel 1
11 Right side panel 1
12 Impeller (plastic) 1
13 Motor bracket 2
14 Single shaft motor 1
15 Double shaft motor 1

AIR DOOR C1.10/C2.10

N o Description Qty
1 Housing 1
2 Plug & wire 1
3 Mounting kit 4
4 Left side panel 1
5 PCB board 1
6 Fixed plate
7 Front board 1
8 Wind board 1
9 Receiver 1
10 Panel 1
11 Right side panel 1
12 Impeller (plastic) 3
13 Motor bracket 2
14 Single shaft motor 1
15 Double shaft motor 1

AIR DOOR C1.12/C2.12

N o Description Qty
1 Housing 1
2 Plug & wire 1
3 Mounting kit 4
4 Left side panel 1
5 PCB board 1
6 Fixed plate 1
7 Front board 1
8 Wind board 1
9 Receiver 1
10 Panel 1
11 Right side panel 1
12 Impeller (plastic) 1
13 Motor bracket 2
14 Double shaft motor 1

AIR DOOR C1.15/C2.15

N o Description Qty
1 Housing 1
2 Plug & wire 1
3 Mounting kit 4
4 Left side panel 1
5 PCB board 1
6 Fixed plate 1
7 Front board 1
8 Wind board 1
9 Receiver 1
10 Panel 1
11 Right side panel 1
12 Impeller (plastic) 5
13 Motor bracket 3
14 Single shaft motor 1
15 Double shaft motor 2

AIR DOOR C1.18/C2.18

N o Description Qty
1 Housing 1
2 Plug & wire 1
3 Mounting kit 6
4 Left side panel 1
5 PCB board 1
6 Fixed plate 1
7 Front board 1
8 Wind board 1
9 Receiver 1
10 Panel 1
11 Right side panel 1
12 Impeller (plastic) 6
13 Motor bracket 3
14 Double shaft motor 3

AIR DOOR C1.20/C2.20

N o Description Qty
1 Housing 1
2 Plug & wire 1
3 Mounting kit 6
4 Left side panel 1
5 PCB board 1
6 Fixed plate 1
7 Front board 1
8 Wind board 1
9 Receiver 1
10 Panel 1
11 Right side panel 1
12 Impeller (plastic) 6
13 Motor bracket 3
14 Double shaft motor 3

UNIT DIMENSIONS

MODEL DIMENSIONS mm PACKAGE
A B C
AIR DOOR C1.09 / C2.09 49 822

x 270
AIR DOOR C1.10 / C2.10| 49| 922| /| 278| 1.020| 313| 41,5| 230| 1.045 x 325 x 270
AIR DOOR C1.12 / C2.12| 49| 1.122| /| 278| 1.220| 313| 41,5| 230| 1.245 x 325 x 270
AIR DOOR C1.15 / C2.15| 49| 1.422| /| 278| 1.520| 313| 41,5| 230| 1.545 x 325 x 270
AIR DOOR C1.18 / C2.18| 49| 861| 861| 278| 1.820| 313| 41,5| 230| 1.845 x 325 x 270
AIR DOOR C1.20 / C2.20| 49| 961| 961| 278| 2.020| 313| 41,5| 230| 2.045 x 325 x 270

TECHNICAL SPECIFICATIONS

  • C1 model with air discharge speed 17/14,5 m/s (High/Low).
  • C2 model with air discharge speed 21/17 m/s (High/Low).
  • Operating voltage 220 – 240V/50 – 60 Hz.

MODEL| AIR FLOW m 3 /h| POWER W (high/low)| NOISE LEVEL dB(A)| WEIGHT kg| WEIGHT mm
---|---|---|---|---|---
W| H| D
AIR DOOR C1.09| 1.260| 260 / 200| ≤ 50| 16| 900|

225

|

290

AIR DOOR C1.10| 1.300| 260 / 200| ≤ 51| 19| 1.000
AIR DOOR C1.12| 1.700| 350 / 280| ≤ 52| 21| 1.200
AIR DOOR C1.15| 2.100| 440 / 350| ≤ 53| 26| 1.500
AIR DOOR C1.18| 2.500| 540 / 430| ≤ 54| 28| 1.800
AIR DOOR C1.20| 2.800| 540 / 430| ≤ 54| 30| 2.000
AIR DOOR C2.09| 1.520| 300 / 240| ≤ 52| 16| 900
AIR DOOR C2.10| 1.800| 300 / 240| ≤ 53| 19| 1.000
AIR DOOR C2.12| 2.030| 400 / 320| ≤ 54| 21| 1.200
AIR DOOR C2.15| 2.500| 550 / 450| ≤ 55| 26| 1.500
AIR DOOR C2.18| 3.000| 640 / 500| ≤ 58| 28| 1.800
AIR DOOR C2.20| 3.300| 670 / 530| ≤ 60| 30| 2.000

MAINTENANCE

To reduce the risk of fire, electrical shock, or injury, please observe the following:

  1. Maintenance must be performed only by a qualified technician, familiar with local codes and regulations, and experienced with this type of product.
  2. Before servicing or cleaning the product disconnect it from the main power supply to prevent being switched “ON” accidentally.

Routine maintenance is required to keep this product operating at its peak performance and efficiency. Over time, the housing, air intake grille, filter, fan impeller, and motor(s) will accumulate a build-up of dust, debris, and other residue. It is imperative to keep these components clean. Failure to do so will not only lower operational efficiency and performance but also reduce the useful life of the product. The time between cleanings depends on the installation, location, and daily hours of use. On average and under normal use conditions, the product should require a thorough cleaning once every six (6) months.

CLEANING PROCEDURE

  1. Verify the product has been disconnected from the main power supply.
  2. Use a damp cloth and either a warm mild soapy water solution or bio-degradable degreaser, to clean the exterior components of the housing.
  3. To access the interior of the product, remove the air intake grille(s) and/or filter(s). This is accomplished by removing the screws on the face of the air intake grille(s) / filter(s).
  4. Thoroughly clean the air intake grille(s)/filter(s).
  5. Thoroughly clean the motor, fan impeller, and fan impeller housings. Be careful not to spray the motor with water.
  6. The motor(s) require no additional lubrication. They are permanently lubricated and feature double-sealed ball bearings.
  7. To re-assemble the product, follow the procedures above backward.
  8. Reconnect the power supply to the product.

If you have any questions regarding the maintenance of the product, contact an authorized agent.

Contact Information

Main Office ATHENS

Factory – THIVA

Factory – THESSALONIKI

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals