MIKROTIK CRS112-8G-4S-IN Networking Switch User Manual

June 15, 2024
Mikrotik

MIKROTIK-logo

MIKROTIK CRS112-8G-4S-IN Networking Switch

MIKROTIK-CRS112-8G-4S-IN-Networking-Switch-product

Product Information

Specifications

  • Model: CRS112-8G-4S-IN
  • Ports: 8 Gigabit Ethernet ports, 4 SFP ports
  • Compatibility: 1.25G SFP modules
  • Power Input: Direct-input power jack (5.5 mm outside and 2 mm inside, female, pin-positive plug), 10-57 V DC
  • Power Consumption: Up to 11 W under maximum load

Product Usage Instructions

Safety Warnings
Before using the device, please read and understand the safety warnings provided in the user manual.

Quick Start

  1. Place the device on a flat surface for mounting.
  2. Connect your PC to any Ethernet port on the device.
  3. Connect the power adapter to the DC jack on the device.
  4. Set the IP address for your PC to 192.168.88.2.
  5. Use the MikroTik Winbox utility or a web browser to perform the initial connection via the Ethernet cable.
  6. Connect to the default IP address of 192.168.88.1 from any port using the username “admin” and no password.
  7. Click the “Check for updates” button and update the RouterOS software to the latest version for optimal performance and stability.
  8. To manually update the device, visit our webpage and download the latest software version packages. Then, open Winbox and upload them to the Files menu.
  9. Reboot the device.
  10. Set up a secure password for the device.

Powering
The device can be powered using the direct-input power jack or through the Ethernet port 1 using passive PoE power input. The power consumption under maximum load is up to 11 W.

Connecting to a PoE Adapter:

  1. Connect the Ethernet cable from the device to the PoE+DATA port of the PoE adapter.
  2. Connect an Ethernet cable from your local network (LAN) to the PoE adapter.
  3. Connect the power cord to the adapter, and then plug the power cord into a power outlet.

Configuration
The device is pre-configured as a switch with IP address 192.168.88.1 for the management interface. RouterOS provides additional configuration options. For more information, visit https://mt.lv/help.

Using Winbox Tool for IP Connection
If the IP connection is not available, you can use the Winbox tool (https://mt.lv/winbox) to connect to the MAC address of the device. The device also has an RJ45 serial port with default settings of 115200 bit/s, 8 data bits, 1 stop bit, and no parity. You can use a standard RJ45 to COM cable (refer to the documentation for pinout).

Buttons and Jumpers
The reset button on the device has the following function:

  • Hold this button during boot time until the user LED light starts flashing, and release the button to reset the RouterOS configuration.

LED Indicators

  • The power LED is lit when the router is powered by the DC jack or PoE.
  • The user LED can be configured from RouterOS.
  • The port LEDs indicate the individual Ethernet and SFP port activity.

FAQ

  1. Can I use non-1.25G SFP modules with this device?
    No, this device is only compatible with 1.25G SFP modules.

  2. How do I update the RouterOS software manually?
    To manually update the RouterOS software, visit our webpage and download the latest software version packages. Then, open Winbox and upload them to the Files menu.

  3. What is the default username and password for the device?
    The default username is “admin” and there is no password (or refer to the sticker on some models for user and wireless passwords).

This device is a network switch with eight gigabit Ethernet ports and four SFP ports. It is already configured, with all ports switched together. This unit is compatible with 1.25G SFP modules.

Safety Warnings

  • Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing accidents.
  • Ultimate disposal of this product should be handled according to all national laws and regulations. The Installation of the equipment must comply with local and national electrical codes.
  • This unit is intended to be installed in the rackmount. Please read the mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation for people and damage to the system.
  • This product is intended to be installed indoors. Keep this product away from water, fire, humidity, or hot environments.
  • Use only the power supply and accessories approved by the manufacturer, which can be found in the original packaging of this product.
  • Read the installation instructions before connecting the system to the power source.
  • We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your own risk!
  • In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.
  • It is the customer’s responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik devices must be professionally installed.

Quick start

The Default configuration, Switch mode all interfaces are switched; LAN Configuration. All ports are bridged with IP 192.168.88.1/24 set on the bridge.

  • Place on a flat surface (see “Mounting”).
  • Connect your PC to any Ethernet port.
  • Connect the power adapter to the DC jack.
  • Set the IP for your PC to 192.168.88.2
  • The Initial connection has to be done via the Ethernet cable, using the MikroTik Winbox utility or Web browser.
  • Use Winbox or a Web browser to connect to the default IP address of 192.168.88.1 from any port, with the username admin and no password (or, for some models, check user and wireless passwords on the sticker).
  • We recommend clicking the “Check for updates” button and updating your RouterOS software to the latest version to ensure the best performance and stability. The device needs to have an active internet connection.
  • To manually update the device go to our webpage and download the latest software version packages.
  • Open Winbox and upload them to the Files menu.
  • Reboot the device.
  • Set up your password to secure the device.

Powering

The board accepts power from the direct-input power jack (5.5 mm outside and 2 mm inside, female, pin-positive plug) and accepts 10-57 V ⎓ DC. The Ethernet port 1 also accepts passive PoE power input. The power consumption of this device under maximum load is up to 11 W. It is possible to connect both power inputs at the same time and they will work in failover mode (input with higher voltage will work as the main source).

Connecting to a PoE Adapter:

  1. Connect the Ethernet cable from the device to the PoE+DATA port of the PoE adapter.
  2. Connect an Ethernet cable from your local network (LAN) to the PoE adapter.
  3. Connect the power cord to the adapter, and then plug the power cord into a power outlet.

Configuration

The device is set up as a switch, with 192.168.88.1 as the management IP of the bridge interface. RouterOS includes many configuration options in addition to what is described in this document. We suggest starting here to get yourself accustomed to the possibilities: https://mt.lv/help.

  • In case the IP connection is not available, the Winbox tool (https://mt.lv/winbox) can be used to connect to the MAC address of the device.
  • The device is equipped with an RJ45 serial port, set by default to 115200 bit/s, 8 data bits, 1 stop bit, and no parity. Standard RJ45 to COM cable can be used, pinout can be found in the documentation (see link above).
  • For recovery purposes, it is possible to boot the device for reinstallation, see the next section.

Buttons and Jumpers

The reset button has these functions:

  • Hold this button during boot time until the user LED light starts flashing, and release the button to reset the RouterOS configuration.
  • Keep holding the button for 5 more seconds or until the user LED turns off, then release it to make the RouterBOARD look for Netinstall servers. The first Ethernet port is used for the Netinstall process. Regardless of the above option used, the system will load the backup routerBOOT loader if the button is pressed before power is applied to the device. Release the button before the LED begins to flash, to only load the backup routerBOOT without reset. This is useful for RouterBOOT debugging and recovery.

LED indicators

  • The power LED is lit when the router is powered by the DC jack or PoE.
  • The user LED can be configured from RouterOS.
  • The port LEDs indicate the individual Ethernet and SFP port activity.

Mounting

The device is designed to use indoors and it can be mounted in a rackmount enclosure using provided rack mounts, or it can be placed on the desktop. Please use a Phillips screwdriver to attach rackmount ears on both sides of the device if the designated use is for rackmount enclosure:

  1. Attach rack ears to both sides of the device and tighten four screws to secure them in place, as shown in the picture.
  2. Place the device in the rackmount enclosure and align it with the holes so that the device fits conveniently.
  3. Tighten screws to secure it in place.
  • The device has no protection from water contamination, please ensure the placement of the device in a dry and ventilated environment.
  • We recommend Cat6 cables for our devices.
  • The mounting and configuration of this device should be done by a qualified person.

Specifications

Please visit the wiki pages for the MikroTik SFP module compatibility table: https://wiki.mikrotik.com/wiki/MikroTik_SFP_module_compatibility_table
For more information about this product, specifications, pictures, downloads, and test results please visit our web page: https://mikrotik.com/product/CRS112-8G-4S-IN

Operating System Support

The device supports RouterOS software with version number 6.45.6 at or above what is indicated in the RouterOS menu /system resource. Other operating systems have not been tested.

Included parts

MIKROTIK-CRS112-8G-4S-IN-Networking-Switch-fig-2

To avoid pollution of the environment, please separate the device from household waste and dispose of it in a safe manner, such as at designated waste disposal sites. Familiarize yourself with the procedures for the proper transportation of the equipment to the designated disposal sites in your area.

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class A digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note:
This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.

Innovation, Science, and Economic Development Canada
This device complies with Industry Canada’s license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

UKCA marking

CE Declaration of Conformity

  • Manufacturer: Mikrotikls SIA, Brivibas gatve 214i Riga, Latvia, LV1039.
  • The full text of the EU Declaration of Conformity is available at the following internet address: https://mikrotik.com/products.
  • Information contained here is subject to change. Please visit the product page on www.mikrotik.com for the most up-to-date version of this document.

References