Home-it 58090 Gas Space Heater User Manual
- June 15, 2024
- Home-it
Table of Contents
- Home-it 58090 Gas Space Heater
- Product Information
- Product Usage Instructions
- GENERAL HAZARD WARNING
- Technical specifications
- Special safety regulations
- Safety clearance
- Installation
- Use
- Cleaning and Maintenance
- Troubleshooting
- Circuit diagram
- ENVIRONMENT
- SERVICE AND REPAIR
- CONTACT
- Documents / Resources
Home-it 58090 Gas Space Heater
Product Information
- Product Name:
- Gas Space Heater with Regulator
- Model Number:
- 58090
- Brand:
- Millarco
- Specifications
- Technical Data:
- Safety Clearance:
- Installation:
- Usage:
Product Usage Instructions
- Safety Precautions
- Use the provided pressure regulator only.
- Never use the heater without its cover.
- Never block the inlet or outlet sections of the heater.
- Installation
- Follow the safety clearance guidelines provided.
- Install the gas space heater in a well-ventilated area.
- Usage
- To start the heater, turn on the gas cylinder valve and ignite the burner using the spark.
- Adjust the temperature using the thermostat.
- To stop the heater, turn off the gas cylinder valve and wait for the flame to extinguish before turning off the fan switch.
- Use as a Fan
- The gas space heater can also be used as a fan without igniting the burner.
- Simply turn on the fan switch to circulate air without producing heat.
- Cleaning and Maintenance
- Regularly clean the heater to remove dust and debris.
- Perform maintenance tasks as recommended in the user manual.
- FAQ
- Problem: The motor is not functioning.
- Check for any loose connections or damaged wiring.
- Contact customer service for further assistance.
- Problem: The heater stops during operation.
- Ensure that the gas supply is sufficient and not blocked.
- Check the thermostat and replace it if needed.
- Inspect the ventilation system for any obstructions.
- Problem: There is no spark.
- Check the ignition system for any faults or loose connections.
- Ensure proper grounding of the heater.
- Problem: The safety device is malfunctioning.
- Contact customer service for professional repair or replacement.
- Problem: The gas supply is too strong.
- Check the pressure regulator and replace it if necessary.
GENERAL HAZARD WARNING
- FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THE HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
- ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
- The heater is NOT to be used for the heating of habitable areas of domestic premises, or for use in public buildings. Please refer to national regulations. NOT FOR HOME OR RECREATIONAL VEHICLE USE.
- Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to use the heater
- Do not leave children unsupervised when the heater is being used.
- Never let children sit or stand on the heater. Never let children play around the heater.
- CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
- This product is not suitable for primary heating purposes.
- WARNING: To avoid overheating, do not cover the heater.
Technical specifications
- Model number 58090
- Type of gas LPG only
- Gas Supply Pressure 2 Bar
- Voltage/frequency 220-240 V~ 50 Hz
- Ignition Piezo
- Primary Flame Control Thermal Probe Operated Gas Valve
- Overheating Protection 95 °C
- Insulation Grade Class I
- Heat rating 51180 BTU (15 kW)
- Fuel Consumption 1.09 kg/h
- Nozzle size 0.90 mm
- Air Flow Temp. 420 °C
Special safety regulations
- The heater must only be used outdoors or in well ventilated surroundings away from combustible materials
- For every kW of heating power, it is necessary to have permanent ventilation of 25 cm³, equally distributed between the floor and high level, with a minimum outlet of 250 cm³.
- Gas cylinders must be used and kept in accordance with current regulations.
- Never direct the hot air flow towards the cylinder.
- Use only the supplied pressure regulator.
- Never use the heater without its cover.
- Do not exceed 100 W/m³ of free room. The minimum volume of the room must be larger than 100 m³.
- Do not obstruct the inlet or outlet sections of the heater.
- If the heater has to work for a long period at its maximum capacity, it’s possible that ice will form on the cylinder. This is due to excessive vapour withdrawal. Not for this reason, or for any other, should the cylinder be heated. To avoid this effect, or at least to reduce it, use a large cylinder or two cylinders linked together.
- Do not use the heater in cellars, basements or in any room below the ground level.
- Ensure that the fan is operating correctly before lighting the burners. In case of malfunction, please contact the technical assistance service.
- After use, turn the gas cylinder tap off.
- The gas bottle must always be replaced following safety rules away from any possible source of ignition.
- The gas hose must not be twisted or bent.
- The heater must be placed where there is no risk of fire, the hot air outlet must be at least 3 m from any flammable wall or ceiling and must never be directed towards the gas bottle.
- Only use original gas hose and spare parts.
- In the case that a gas leak is found or suspected, immediately close the gas cylinder, switch the heater off and do not use it again until it has been checked by a qualified service centre.
- If the heater is installed indoors, provide a good ventilation by opening door and windows completely. Do not produce sparks or free flames.
- If in any doubt contact your supplier.
Safety clearance
Installation
- Connect the heater to a suitable electric socket.
- Make sure that the machine is properly earthed.
- Connect the gas supply hose to the pressure regulator and connect the regulator to a suitable LPG cylinder.
- Open the tap of the cylinder and check the supply hose and fittings for gas leaks. For this operation, it is recommended to use an approved leak detector. NEVER USE NAKED FLAME.
- For automatic appliances, connect the room thermostat to the socket on the appliance and adjust it to the required temperature.
Use
- Preparing for use
- Check the heater for possible shipping damage.
- Connect the hose and regulator assembly to the LPG cylinder. Only use a CE-approved regulator and hose with a ¼” connector.
- Carry out a leakage test using soapy water before using the heater. Never use naked flame!
- Open the cylinder’s gas valve and check all gas connections with a soap and water solution.
- Connect power cord to well-grounded power outlet.
- Ignition
- Turn the power switch (1) to position I and check that the fan starts running correctly.
- Push the gas valve button (2) and push repeatedly the piezoelectric lighter (3) until the flame lights up.
- As the flame lights up, keep the valve button pushed for 10 seconds approx.
- Should the heater stop when the valve button has been released, wait one minute and repeat the starting operation keeping the valve button pushed for a longer time.
- Regulate the gas flow pressure according to the thermal power desired, by turning the wheel of the pressure reducer anticlockwise to increase the pressure or clockwise to decrease.
- Contact your supplier should any problem continue.
- CAUTION! If ignition is difficult or irregular before repeating the ignition operations make sure that the fan is not locked and the air inlet and outlet are unobstructed.
- Switching off
- To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts down and then turn the fan switch to position O.
- Using as a fan only
- The heater can also be used as a ventilator.
- In this case, remove the gas supply hose and connect the plug of the heater to a suitable electrical supply. Set the power switch to position I.
WARNING – Asphyxiation Hazard
- Do not use a heater for heating human quarters.
- Do not use it in unventilated areas.
- The flow of combustion and ventilation air must not be obstructed.
- Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
- Lack of proper ventilation air will lead to improper combustion.
- Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.
FUEL GAS ODOR
- LP gas and natural gas have manmade odorants added specifically for the detection of fuel gas leaks.
- If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
- Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
- Get everyone out of the building and away from the area immediately.
- Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.
- Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.
- Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not reenter the building or area.
- Stay out of the building and away from the area from the area until declared safe by the firefighters and your fuel gas supplier.
- FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return.
- Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.
Cleaning and Maintenance
- The repairs or maintenance operations must only be carried out by qualified personnel.
- The unit must be checked by a qualified technician at least once a year.
- Regularly check the conditions of the gas hose, and gas regulator if they must be replaced only use the original spare parts.
- Before starting any maintenance operation on the heater disconnect from both gas and electrical suppliers.
- If the unit has not been used for a long period we advise that a technician carries out a general check-up before using. It is important to control the following:
- Periodically check the gas supply hose conditions and, should it be changed, use only the original spare parts.
- Check the starting electrode position.
- Check the connections of the safety thermostat and the thermocouple: they must always be clean.
- If necessary clean the fan blade and the inside of the heater using compressed air.
Troubleshooting
You can solve many common problems easily, saving you the cost of a possible service call. Try the suggestions below to see if you can solve the problem before calling the service centre.
Problem | Possible cause | Solution |
---|---|---|
The motor does not work | No electricity supply | Check the terminal board with |
a tester
The safety thermostat is on| Wait about one minute then restart
The motor works, but the burner does not light up and after a few seconds the
heater stops| The cylinder gas tap is closed| Open the gas tap
The cylinder is empty| Use a new cylinder
The nozzle is obstructed| Remove the nozzle and clean it.
The solenoid gas valve is not open| Check that the solenoid valve works
There is no spark| Check the position of electrode
The burner lights up but after a few seconds the heater stops| No connection
with the earthing system| Check and connect properly
Defective connection between sensor and safety device| Check and connect
properly
Defective safety device| Replace the safety device
The heater stops during the operation| Excessive gas supply| Check the
pressure reducer and if required replace it
Insufficient airflow| Check that the motor works properly
Insufficient gas supply due to ice formation on the cylinder| Check and use a
larger cylinder or two cylinders connected to gether.
Circuit diagram
ENVIRONMENT
- The symbol on the product or in the instructions means that your electrical and electronic equipment should be disposed at the end of its life separately from your household waste.
- There are separate collection systems for recycling in the EU.
- For more information, please contact the local authority or the retailer where you purchased the product.
SERVICE AND REPAIR
We provide a warranty on our products by the legal provisions applicable in
each country. Proof of purchase must be presented/submitted.
Service and repairs are offered free of charge within the warranty period
by the Danish Sale of Goods Act on the following conditions:
- The fault is a design or material fault (excluding normal wear and tear and misuse).
- Repairs have not been attempted by anyone other than Millarco’s approved service workshops.
- Non-original spare parts have not been used with the product.
- Free-of-charge servicing includes the replacement of defective parts and labor.
- The product must be taken to the point of sale, which will forward the product to us. We do not accept repairs or warranty obligations directly from customers.
- In the event of technical questions, you are welcome to contact our service workshop:
CONTACT
- Millarco International A/S,
- Rokhøj 26, 8520 Lystrup, Denmark
- Service Telephone: +45 8743 4233
- E-mail: service@millarco.dk.
Millarco International A/S – Rokhøj 26, DK-8520 Lystrup
EN: CE Declaration of Conformity. We declare the following compliance in
accordance with EU directives as well as standards for article:
Item no.: 58090 Item name.: Heater Item Brand: Home>it
Directive
GAR 2016/426
EMC directive 2014/30/EU
Standards:
EN 1596:1998/A1:2004 EN 60335-2-102:2016
EN 55014-1:2017+A11 EN 55014-2:2015
EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1
Lystrup, Denmark 29-03-2022
Signeret Lars Bærentsen
DK-8520 Lystrup
www.millarco.com.
Model identifier(s): BGA1401-10-18, BGA1401-10, BGA1501-10, BGA1805-10, BGA1901-10, BGA2002-10, BGA2003-10
Indirect heating functionality: [no]
Direct heat output: 10(kW)
Indirect heat output: N/A (kW)
Fuel
| | | Space heating emissions
NOx
Select fuel type| [gaseous]| G30| 111.25 [mg/ **kWh input ]
****(GCV)
| | |
Item| Symbol| Value| Unit| Item| Symbol| Value| Unit
Heat output| Useful efficiency (NCV)**
Nominal heat
output
| Phnom| 10| kW| Useful efficiency at nominal
heat output
| ηth, nom| 100| %
Minimum heat
output (indicative)
| Pmin| N/A| kW| Useful efficiency at minimum
heat output (indicative)
| ηth, min| N/A| %
| | | | | | |
Auxiliary electricity consumption| Type of heat output/room
temperature control (select
At nominal heat
output
| max| N/A| kW| Single-stage heat output, no room temperature| [yes]
At minimum heat output| Elgin| N/A| kW| Two or more manual stages, no room
temperature control| [no]
In standby mode| elSB| N/A| kW| with mechanic thermostat room temperature
control| [no]
| with electronic room temperature control| [no]
| with electronic room temperature control plus| [no]
| with electronic room temperature control plus| [no]
| Other control options (multiple selections possible)
| room temperature control, with the presence| [no]
| Room temperature control, with an open window| [no]
| with a distance control option| [no]
| with adaptive start control| [no]
| with working time limitation| [no]
| with a black bulb sensor| [no]
Permanent pilot flame power requirement|
Pilot flame power
requirement (if applicable)
| Pilot| 0| kW| | | |
Contact details
| NingBo Baogong Electrical Appliance CO., LTD.
Fuhai Industrial Zone, Cixi, Ningbo, Zhejiang,315332, P.R.China
(*) NOx = nitrogen oxides
The seasonal space heating energy efficiency η S
Item| Symbol| Value| Unit
The seasonal space heating Energy efficiency in active mode| ηS,on| 100| %
Correction factor (F1)| /| 0| %
Correction factor (F2)| /| 0| %
Correction factor (F3)| /| 0| %
Correction factor (F4)| /| 0| %
Correction factor (F5)| /| 0| %
Biomass label factor| BLF| 1| /
The seasonal space heating energy efficiency ηS| ηS| 90| %
Energy efficiency classes| A
Documents / Resources
|
Home-it 58090 Gas Space
Heater
[pdf] User Manual
58090 Gas Space Heater, 58090, Gas Space Heater, Space Heater, Heater
---|---