WIRELESS RELAY AC MODULE

U-Prox Relay AC – is a wireless relay which is designed to control EN electrical supply of appliances remotely. The device is connected to the control panel and is configured
with the U-Prox Installer mobile application.

Functional parts of the device (see picture)

U-PROX X12971 Wireless Relay AC Module 1

  1. Device case
  2. Antenna
  3. LED indicator
  4. On/off button
  5. Power IN contacts
  6. Power OUT contacts

TECHNICAL SPECIFICATIONS

  • Output: OUT N, OUT L 10A @ 250V AC max
  • Operations:  100 000
  • Power: 110-250V AC, 50-60Hz
  • Modes:  Impulse, trigger (bistable)
  • Impulse duration: adjustable: 0.1 … 250 seconds
  • Response delay: max. 5 seconds
  • Radio frequency: ISM-band wireless interface with several channels
  • Communication: Secure two way communication, sabotage detection, key – 256 bits
  • Operating temperature range: -10°C to +55°C
  • Dimensions & weight: 44 х 36 х 19,4 mm & 55 grams
  • Case colour: white, black

COMPLETE SET

  1.  U-Prox Relay AC;
  2. Quick start guide

WARRANTY

Warranty for U-Prox devices (except batteries) is valid for two years after the purchase date. If the device operates incorrectly, please contact support@u-prox.systems at first, maybe it can be solved remotely.

DANGER OF ELECTROCUTION!

Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of operating manual. The device is designed to control other electrical devices and must be installed on a 10A line in wall switch boxes with depth not less than 60 mm or other protective cases. All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any maintenance, introducing changes into the configuration of connections or the load must be always performed with disabled fuse or power supply. After installation, all parts of the device, including the antenna, must be inaccessible to contact with the user.

REGISTRATION

U-PROX X12971 Wireless Relay AC Module 2

INSURANCE TEALLA ST FTION LOR OPOCATIONTIMAL

Due to Grade 2 requirement, RF link works with reduction of power in 8 dB

INDICATION IN RANGE

DEVICE PLACEMENT

U-PROX X12971 Wireless Relay AC Module 6

MANUAL RELAY ACTIVATION

U-PROX X12971 Wireless Relay AC Module 7