PENTAIR Intellichem Water Chemistry Controller
Product Information
Specifications
- Product Name: IntelliChem Controller
- Model Number: P/N 521363 Rev. J
- Date of Revision: July 2020
- Technical Support: Phone – 800-831-7133, Fax – 800-284-4151
- Website: www.pentair.com
Important Safety Instructions
Before installing this product, it is crucial to read and follow all warning notices and instructions provided in the guide. Failure to do so may result in severe injury, death, or property damage. It is recommended to keep these instructions for future reference.
Technical Support
If you require additional copies of the instructions, you can contact our technical support team at 800-831-7133 or visit our website at www.pentairpool.com.
Product Usage Instructions
1. Checking pH and Sanitizer Levels
Prior to using your pool, spa, or hot tub, it is important to check the pH and sanitizer levels of the water. This ensures a safe and healthy environment. Please refer to the manufacturer’s instructions for specific testing methods and acceptable ranges for pH and sanitizer levels.
2. Acid-Water Mixing
When mixing acid with water, always remember to add acid to water. Never add water to acid. This order of mixing prevents potential hazards. Follow the manufacturer’s instructions carefully when adding any chemicals to the pool/spa. It is crucial to avoid mixing sodium hypochlorite and muriatic acid together.
3. Electrical Safety
To reduce the risk of electrical shock, it is recommended to connect the IntelliChem controller to a ground-fault interrupter-circuit (GFCI). If you are unsure if the receptacle is protected by a GFCI, consult a qualified electrician. Please note that if the clear overfeed limit setting is set to 24 hours, do not set the feed time greater than 20 hours as it will void NSF certification.
4. Chemical Handling and Storage
When working with chemicals such as muriatic acid (hydrochloric acid) and chlorine (sodium hypochlorite), it is essential to take necessary precautions:
- Muriatic acid and chlorine can cause severe burns to the skin, mouth, and eyes. Avoid direct contact and wear appropriate protective gear.
- Inhalation of muriatic acid and chlorine (liquid and mist) can cause severe lung damage. Ensure proper ventilation when handling these chemicals.
- Store chemical feed pumps and chemical storage tanks in a safe and secure area to prevent accidents.
5. Compliance with Codes and Regulations
It is important to comply with state, local, and national codes when installing and operating public pools, spas, and residential pools. These codes often regulate the installation and usage of products like the IntelliChem controller. Please consult your local building and health codes for more information.
6. Underwater Light Installation
Prior to installing the underwater light, ensure that the pool or spa meets the requirements of the current National Electrical Code (N.E.C.) Article 680-22 and all local codes and ordinances. It is necessary to have a licensed or certified electrician install the electrical system to meet or exceed these requirements.
Frequently Asked Questions
Q: Where can I get additional copies of the instructions?
A: You can contact our technical support team at 800-831-7133 or visit our website at www.pentairpool.com for additional free copies of the instructions.
Q: Can I mix sodium hypochlorite and muriatic acid together?
A: No, it is important to avoid mixing sodium hypochlorite and muriatic acid together. Follow the manufacturer’s instructions carefully when adding any chemicals to the pool/spa.
INTELLICHEM® WATER CHEMISTRY CONTROLLER
INSTALLATION AND
USER’S GUIDE
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Phone: 800-831-7133 – Fax:
800-284-4151 visit
www.pentair.com
P/N 521363 Rev. J 7/2020
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND
USED CORRECTLY. INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE
WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. Most states and local
codes regulate the construction, installation, and operation of public pools
and spas, and the construction of residential pools and spas. It is important
to comply with these codes, many of which directly regulate the installation
and use of this product. Consult your local building and health codes for more
information. IMPORTANT NOTICE – Attention Installer: This Installation and
User’s Guide (“Guide”) contains important information about the installation,
operation and safe use of this product. This Guide should be given to the
owner and/or operator of this product.
Before installing this product, read and follow all warning notices and
instructions in this Guide. Failure to follow warnings and instructions can
result in severe injury, death, or property damage. Call
800-831-7133 for additional free copies
of these instructions. Please refer to
www.pentairpool.com for more information related
to this products.
DO NOT INSTALL THE INTELLICHEM® CHEMICAL CONTROLLER WHERE IT CAN BE ACCESSIBLE
TO THE PUBLIC.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION: BEFORE WORKING ON INTELLICHEM®
CHEMICAL CONTROLLER: Always disconnect power to the IntelliChem controller at
the circuit breaker before servicing. Failure to do so could result in death
or serious injury to service person, pool users or others due to electric
shock. BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING THE
INTELLICHEM CONTROLLER. AC Power may be supplied to the relay terminals
Ex_Relay1 and Ex_Relay2 from other sources. See page 31 for details. This
product must be installed by a licensed or certified electrician or a
qualified pool professional in accordance with the National Electrical Code
(NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.2. All
applicable local installation codes and ordinances must also be adhered to.
Improper installation will create an electrical hazard which could result in
death or serious injury to pool users, installers or others due to electrical
shock, and may also cause damage to property.
BEFORE USING YOUR POOL, SPA OR HOT TUB, CHECK THE pH AND SANITIZER LEVELS OF
THE WATER. Do not permit children to operate this equipment.
When mixing acid with water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO
ACID. When adding any chemical to the pool/spa, be sure to follow the
manufacturer’s instructions thoroughly. DO NOT MIX SODIUM HYPOCHLORITE AND
MURATIC ACID
Risk of electrical shock. Connect IntelliChem controller to a ground-fault
interrupter-circuit (GFCI). Contact a qualified electrician if you cannot
verify that the receptacle is protected by a GFCI. IF “CLEAR OVERFEED LIMIT”
SETTING IS SET TO 24 HOURS, DO NOT SET “FEED TIME” GREATER THAN 20 HOURS AS
THIS WILL VOID NSF CERTIFICATION.
INTELLICHEM® Controller Installation and User’s Guide
ii
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main
circuit breakers at the house before drilling into any pipes. Securely fasten
all electrical, water and chemical lines. Locate chemical feed pumps and
chemical storage tanks in a safe and secure area.
Strictly follow the acid manufacturers safety and handling protocols including
hand, body and eye protection when transferring or handling acid. Safety
precautions should be used when handling Muriatic acid to control pH water
levels. Muriatic acid can cause serious body injury and damage pool equipment.
Extra care must be taken when installing, maintaining and operating acid pump
feed systems. Acid is dangerous to handle and should be properly contained,
transported, poured, stored, and dispensed.
· Check the pH and sanitizer levels of the water before use. · Periodically
use an independent pH and Chlorine test kit to verify that pH
and chlorine is at a safe level. If the pH and Oxidation Reduction Potential
(ORP) or Flow Cell sensors are broken, depleted or dirty with oils, lotions,
or other contaminants, they can report inaccurate results to the system
causing incorrect water chemistry, which could harm people or equipment. ·
Check the IntelliChem® Controller main status display each day to ensure there
are no Alarm messages. See “Troubleshooting” on page 45 for more information.
When using IntelliChem with a pool pump timer: The Association of Pool and Spa
Professionals (APSP) recommends that all water in a residential pool pass
through the filtration system at least once every 12 hours (referred to as
pool water turnover). However, many factors have an effect on actual pump and
filter system run times. Pool size, source of water, direct sun light,
indoor/outdoor, screened and unscreened, filtration system, cold or hot
weather, swimmer load, rain, organic debris, algae, etc., are all factors
which contribute to either more or less pool pump and filter system run times.
Because of these differences, it is extremely difficult to set an initial run
time (starting point) for the pool pump and chlorinating system. Try initially
setting the pool pump timer to 12 hours. It will take a few days to get just
the right amount pool pump operating time. When the Chlorinator is wired with
a pool pump timer (see page 6) results will vary greatly from one pool
installation to the next, so this should be discussed with either the pool
builder or your pool professional.
Using CO2 for pH Control
Plaster pools and pools using salt-chlorine generators typically cause a slow
pH rise which must be managed. With the IntelliChem® controller muriatic acid
or carbon dioxide (CO2) is dispensed into the filter system’s return water as
needed until the Flow Cell pH sensor detects the proper pH level. Using CO2
for pH control eliminates the need to handle and stored acid and can be a
safer method. As CO2 gas is injected into the pool water, it dissolves and
creates carbonic acid. This weak acid is very efficient at lowering pH with
the added benefit of self-limiting if the CO2 is over-fed.
iii
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
Most states and local codes regulate the construction, installation, and
operation of public pools and spas, and the construction of residential pools
and spas. It is important to comply with these codes, many of which directly
regulate the installation and use of this product. Consult your local building
and health codes for more information.
IMPORTANT NOTICE – Attention Installer: This Installation and User’s Guide
(“Guide”) contains important information about the installation, operation and
safe use of this product. This Guide should be given to the owner and/or
operator of this equipment.
Before installing this product, read and follow all warning notices and
instructions in this Guide. Failure to follow warnings and instructions can
result in severe injury, death, or property damage. Call
800-831-7133 for additional free copies
of these instructions. Please refer to www.pentairpool.com
for more information related to this products.
Working with muriatic acid can be dangerous. When cleaning the IECG always
wear rubber gloves and eye protection. Always add acid to water, do not add
water to acid. Always work in a well-ventilated area. Splashing or spilling
acid can cause severe personal injury and/or property damage. Pentair always
recommends 1:1 dilution when using full strength muriatic acid. When mixing,
remember to always add acid to water. IMPORTANT! TAKE EXTREME CARE WHEN
INSERTING THE ACID CONTAINER INTO THE STORAGE TANK, AS THE FOIL SEAL MAY NOT
BE FULLY ATTACHED.
Be sure that the pool or spa meets the requirements of the current National
Electrical Code (N.E.C.) Article 680-22 and all local codes and ordinances. A
licensed or certified electrician must install the electrical system to meet
or exceed those requirements before the underwater light is installed.
READ THE FOLLOWING BEFORE HANDLING AND WORKING WITH MURIATIC ACID (ALSO KNOWN
AS HYDROCHLORIC ACID) AND CHLORINE (SODIUM HYPOCHLORITE)
MURIATIC ACID AND CHLORINE (LIQUID AND MIST) CAN CAUSE SEVERE BURNS TO SKIN,
MOUTH AND EYES. MAY BE FATAL IF SWALLOWED OR INHALED. INHALATION CAN CAUSE
SEVERE LUNG DAMAGE.
IMPORTANT! CHLORINE CONTAINER
MIXING CHEMICALS WITH CHLORINE OR CHLORINE RESIDUE IN CONTAINER CAN CREATE A
DEADLY GAS OR AN EXPLOSION.
INTELLICHEM® Controller Installation and User’s Guide
iv
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
INHALATION Inhalation of vapors can cause coughing, inflammation of the nose,
throat and upper respiratory tract and death. In case of inhalation, move to
an area of fresh air immediately.
INGESTION Swallowing can be fatal. Contact local poison control center or
physician immediately. Give large amounts of water or milk. Allow person to
vomit. If vomiting occurs, keep head lower than hips to avoid aspiration. If
person is unconscious, turn their head to the side. Seek immediate medical
attention.
STORAGE: Install and store container and acid in a dry, ventilated place
protected from excess heat and direct sunlight. Should be stored at a
temperature below 80°F (27°C). Be sure drainage is located away from building
and equipment.
SKIN CONTACT Wash skin with soap and water for at least 20 minutes and remove
contaminated clothing and shoes. Contaminated clothes should be thoroughly
cleaned before re-use.
EYE CONTACT Flush eyes immediately with water for at least 20 minutes. Seek
immediate medical attention.
PERSONAL PROTECTION
VENTILATION Use container outside and in a well-ventilated area.
EYE PROTECTION Use splash-resistant safety goggles.
CLOTHING Wear chemical-resistant clothing when handling or working with acid
and chlorine.
GLOVES Wear chemical-resistant gloves when handling or working with acid and
chlorine.
DISPOSAL Because of its corrosive nature, muriatic acid is a hazardous waste
when spilled or discarded. Dispose of used acid at an approved hazardous waste
facility or at your municipal household hazardous waste collection facility.
Small spills of acid may be neutralized using baking soda. Carefully pour the
baking soda onto the spilled material until the fizzing stops, then mop or
scoop up the residue. Leave cleanup of large spills to the experts; call your
local fire department or hazardous materials spill team.
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
1
Overview
The INTELLILCHEM® Water Chemistry Controller is a pH and ORP sensing device
that dispenses correct amount of chlorine or bromine, muriatic acid or CO2
gas. The IntelliChem controller provides continual analysis of your swimming
pool water sanitation and pH levels, providing real-time status information to
dispense the proper amount of muriatic acid (pH reducer) and chlorine or
bromine for the correct sanitization and pH balance. The IntelliChem
controller operates with or without a salt chlorine generator to provide a
self-replenishing supply of chlorine generated from salt. The IntelliChem
controller can also connect to carbon dioxide (CO2) liquid gas tanks to lower
pH in your swimming pool water. When CO2 dissolves into water it produces weak
neutral bicarbonate salts which reduces pH. CO2 is environmentally friendly
and produces no secondary pollution into the treated water by salts such as
chlorides or sulfates. CO2 does not corrode metal equipment and does not
require any special piping. The IntelliChem controller supports Pentair
Aquatic Systems (“Pentair”), EasyTouch®, IntelliTouch® and SunTouch®
automation control systems for pH and ORP control. The IntelliChem controller
also supports IntelliChlor® salt chlorine generator (SCG) to help manage your
pool water sanitizer levels. Operating the IntelliChem Controller Before
operating the IntelliChem controller, it’s important to test and adjust your
pool water chemistry to the recommended pool industry levels found in this
manual (see page 19). If you are using an IntelliChlor salt chlorine
generator, adjust the salt levels to the recommended levels in the
IntelliChlor (SCG) Installation and User’s Guide (P/N 520589). During normal
operation, no user input is required, the IntelliChem controller will
automatically sense ORP and pH levels. The current ORP and pH levels are
regularly displayed on the control panel LCD display. Use the pH Settings or
ORP Settings buttons to view or adjust supply levels. The “Auto Setup” feature
provides screen prompts for first-time setup or standard configurations such
as setup reminder times, calculating feed times, proportional limits and
alarms. For details, see page 6. First Balance Your Pool Water IMPORTANT: To
help keep your pool water balanced follow these steps:
1. Use a Test Kit (with fresh testing reagents) to measure the pH,
alkalinity, and calcium hardness of the pool water. For greater accuracy,
Pentair recommends the AcuCheck3 Test Kit to measure pH, chlorine ppm, and
alkalinity levels (P/N 745000110). “Balanced” water has proper levels of pH,
Total Alkalinity and Calcium Hardness. This “balanced” water is neither
corrosive or scaling. The pH (0-14) value is the scale of relative acidity or
alkalinity. Recommended pH range is from 7.2 to 7.6. The IntelliChem
controller default pH value is 7.5 (see page 12).
2. Be sure the pool chlorine level is balanced. Ideal free chlorine level
should be between 1.0 – 3.0 parts per million (ppm).
3. Use the online Langelier Saturation Index (LSI) calculator to diagnose the
water balance in your pool or the IntelliChem controller built-in LSI
calculator (see page 28-31). Refer to: http://www.pentairpool.com/pool-
owner/resources/calculators/langelier/
Note: A Saturation Index value of 0 indicates the water is chemically in
balance. If the Index is a minus (-) value, corrosive tendencies are
indicated. If the Index is a plus (+) value, scale-forming tendencies are
indicated. A Saturation Index value between +0.5 to -0.5 is considered
satisfactory in a swimming pool. See Saturation Index menu on page 28.
INTELLICHEM® Controller Installation and User’s Guide
2
Operator Controls, Indictor and Alarm LEDs
CONTROL PANEL DESCRIPTION
1
2
pH
SETTINGS
pH OK 7.46
Mixing 00:07:03
ORP OK 450
9
3
ORP
SETTINGS
Mixing 00:07:54
4
FLOW
ALARM
8
MENU Select
5 Control Buttons and LEDs:
6
7
1 Liquid Crystal Display (LCD) with backlighting: Displays system status
information and the IntelliChem® Controller main menu. Display backlight and
menu on and off time (30 seconds to 24 hours) can be set via the “LCD Timeout”
menu feature. See “Configuration” menu page 17). Display viewing modes: Select
between two display modes: Basic: pH and ORP status with alarms messages.
Advanced: pH, ORP, status, alarm messages and process timers.
2 pH Settings button: Access the pH settings (see page 3).
3 ORP Settings button: Access the Oxidation Reduction Potential (ORP) settings
(see page 3).
4 Flow LED: Green LED on indicates flow is detected. LED will blink during
flow delay. LED off indicates no flow in the system. If flow is not present,
no chemical feeding or IntelliChem controller activity is allowed. LED
brightness can be adjusted via the Configuration “Display Mode” menu (see page
17).
5 Left arrow button: Scroll through sub-menu items or move cursor left when
editing a setting.
6 Menu button: Access the main menu (see page 11). While in menu mode, used to
exit a menu level. All items are saved as soon as they are changed.
7 Right arrow button: When in menu mode, selects menu main and sub-menu item,
scroll through sub-menu items or move cursor right when editing a setting.
8 Alarm LED: LED is on if an alarm condition occurs. Display shows alarm
message and status (see page 48). LED brightness can be adjusted via the
Configuration “Display Mode” menu (see page 17).
9 Up/Down arrow button: When in a menu mode, use / to scroll through main menu
and sub-menu items, increase, decrease or change a setting or value. Also,
used for moving to next sub-menu page 1/2 – 2/2.
INTELLICHEM® Controller Installation and User’s Guide
3
pH Settings and ORP Settings Buttons
pH Dosage (dispense acid)
DO NOT manually feed pH (acid) and ORP sanitizer (chlorine) at the same time
without sufficient water flow through the piping system. Combining these two
chemicals without sufficient water flow for mixing will result in the
formation of hazardous gas. This menu item will be displayed as Override
[Wait] during no-flow and flow-delay time period.
pH pH Settings button: Press the pH Settings SETTINGS button to access the pH dosage settings.
pH Settings Override [Dose] Level Gauge: 5
Limit cleared
ORP
SETTINGS
ORP Settings button: Press the ORP Settings button to access the Oxidation Reduction Potential (ORP) settings. The ORP is the sanitization quality of the water of a given solution.
ORP Settings Override [Dose] Level Gauge: 5
Limit: [Clear ]
Note: To exit pH Settings and ORP Settings, press the MENU button.
Password Protect: The pH Settings and ORP Settings screens are not accessible
when the Password Lock is set to “ALL”. Set the Password Lock to “OFF” or
“MENU” to access these screens (see page 5).
Override (pH): Press the / Right or Left arrow button to toggle between “Dose”
or “Stop”. Select “Dose” to dispense muriatic acid or CO2 and select “Stop” to
stop dispensing acid or CO2 (pH Settings LED is on). To exit, press the MENU
button or press the Down button to select the “Level Gauge” feature. The
Override feature is not available when CO2 is setup to “Feed to Setpoint.”
Override (ORP): Press the / Right or Left arrow button to toggle between “Dose” or “Stop”. Select “Dose” to dispense chlorine (or bromine) and select “Stop” to stop dispensing chlorine (ORP Settings LED is on). To exit, press the MENU button or press the Down button to select the “Level Gauge” feature. The Override feature is not available when IntelliChlor is setup to “Feed to Setpoint.”
Level Gauge indicator: Press the / Up/Down button to select this feature. The level gauge (volume based) and hour glass (time based) icon is a visual representation of the amount of acid (pH Settings) or chlorine (ORP Settings) available in the container. Press / six times to fill the gauge (container full). The indicator displays six horizontal bars when full. The level gauge is not available if the doser is unable to determine the pump dispense rate, the supply volume, or if there is no supply “reminder” set up (see page 13-15). The gauge is displayed as an “hour glass” if the supply is based on time rather then volume (see page 6)
Limit [Clear]: Press the / to select this feature. Press the / to clear the current dosage limit timer. After pressing the button, “CLEARED” is displayed, indicating that the current dosage limit is cleared.
INTELLICHEM® Controller Installation and User’s Guide
4
IntelliChem® Controller System Power Up Sequence
IntelliChem® Controller Power-up Sequence: During power-up the IntelliChem®
v1.080 07/31/2018 Controller displays the initialization screens before the
Pentair Aquatic
main status screen is displayed. During this initial power up
Systems
sequence, the IntelliChem controller performs an internal self
AUTO CALIBRATION
test and continues with a system calibration. The first screen includes the current software version and date.
AUTO CALIBRATION is displayed each time IntelliChem is
powered up.
AUTO CALIBRATION In the next auto-calibration sequence the pH and ORP meters pH 6.35 7.65 OK are tested with on-board circuitry and calibrated to the built-in
ORP 738 398 OK reference devices. An out-of-tolerance condition is immediately
PASSED
reported as an error so the user can have the unit serviced.
IntelliChem Auto Setup Wizard
Press MENU to go to each new step
The very first time IntelliChem controller is powered up and after a factory reset, the Auto Setup Wizard start screen is displayed. Otherwise access the wizard from the main menu (see page 6).
Awaiting
The normal start up screen will simply be this one, awaiting
POWER&FLOW DELAY Power On & Flow Delay. The countdown timer shows the
H:00 M:14 S:18
remaining time before the unit starts reading the probes and
please wait…
controlling the doser.
pH OK 7.5 ORP OK 450
Main Status Screen: After IntelliChem controller has completed the Flow Delay the main status screen displays the measurements of the connected pH and ORP sensors.
INTELLICHEM® Controller Installation and User’s Guide
5
Set Password Protect
The password protect feature prevents access to certain menus and prohibits all menu changes and manual feeds. For more information, see Set Password on page 18. To set the password protect:
Set Password
PW
[1234]
Press MENU / Configuration and / Set Password.
Lock
[Off ] 2. Set Password (PW): Press the / Up/Down
arrow button to select the first password digit (0-9).
3. Press the / Right/Left arrow button to move the
cursor to the next digit.
Locked – Please enter 4. Press the / Up/Down arrow button to select the
password
second password digit. Repeat steps 3 and 4 for the
1234
third and fourth password digit. 5. Press the Right arrow button to move the cursor
to the Lock Menu setting. 6. Press the / Up/Down arrow button to select
OFF: Do not enable control panel button lockout.
ALL: Lockout MENU, pH Settings and ORP Settings
buttons). Tank Levels cannot be changed.
MENU: Lockout MENU button (not pH Settings and
ORP Settings buttons). Setpoints or Sat Index values
TA, CYA, CH cannot be changed.
7. To exit, press the MENU button (press three times to
return to the main screen.
Tip: Setting the password 0000 allows you to enter a protected screen by pressing MENU. Also, once the password is entered, access is granted for the duration specified by the Menu timeout setting in the Configuration/Display Mode menu (see page 17).
Password Protect and IntelliTouch®, EasyTouch® and SunTouch® Control Systems
Note: If the password lock is enabled from IntelliChem controller it will also
be locked out on the IntelliTouch, EasyTouch or SunTouch automation control
system.
When IntelliChem is controlled by the IntelliTouch, EasyTouch or SunTouch
control system, if the password is set and locked on the IntelliChem, it
cannot be changed from the automation control panel. To change a “LOCKED”
password from the automation system, enter the password on the IntelliChem
controller, it will remain active for the Menu Timeout MM:SS period. During
that time, the automation system will be able to set the appropriate settings,
just as you would from the IntelliChem controller front panel. Receiving
updated settings from automation will continue to extend the Menu Timeout,
just as if you’re accessing the menu on the IntelliChem controller itself.
INTELLICHEM® Controller Installation and User’s Guide
6
Display Modes
H COT2he- dOisRplays shows t
The main IntelliChem® Controller status screen can be setup to display basic or advanced system information. To setup the Display Mode, see “Configuration” menu on page 17. The Basic display mode shows the current pH and ORP measurements including a message describing any existing pH (line two) and ORP (line four) alarms. The Advanced display mode shows all the current measurements and alarm messages as well as dose and mix timers showing the progress of those processes.
Basic display mode
pH >OK 7.4 -.72 Scaling
ORP OK 730 Monitoring
The Basic mode displays the current pH and ORP measurements (pH in10th and ORP
in 5mV) with any alarms
Note: Alarms are displayed on all Basic and Advanced modes. >OK or <OK is
displayed as soon as the value exceeds alarm trip point. That is replaced with
“HIGH/LOW” after the
Advanced display mode Displays three different Alarms. The example screen shows:
pH HIGH 7.91 pH Dose Limit
ORP OK 683
Dose limit, high reading and chemical tank low alarm. These can co-exist. The advanced mode displays the current pH and ORP high precision measurements (extra digit. e.g. pH=100th –
Mixing 00:07:54 ORP=1mV resolution), alarms, tank levels, process messages
and timers.
Basic and Advanced Display with Error Messages
NO FLOW DETECTED If IntelliChem detects the pool water circulation pump is not
Check pump, flow active, a NO FLOW message is displayed. ORP and pH values
Cell, filter,
are not measured when there is no flow, and therefore not
and valves.
displayed.
Auto Setup Sequence
Use the Auto Setup feature for first-time setup or standard configurations. Follow the onscreen prompts and enter information about your system configuration (pH/ORP internal or external pumps, pool size, filter time, chemical container size etc). IntelliChem uses this information to automatically setup reminder times, calculate feed times, proportional limits and alarms. The following describes the Auto Setup screen. Press the MENU button to access the Auto Setup menu. To change a menu setting or value press the / Up/ Down arrow button. Press the MENU button to save each selection.
Press MENU / Auto Setup
Previous Values: Use to recalculate new dose times etc., if no custom settings exist. Not
recommended for custom settings; use the menu directly to make these changes.
Reset All: Make major configuration changes that may have conflicts with previous
settings.
IntelliChem Auto Setup Wizard Press MENU to go to each new step
Dosing will resume when you exit this menu Press any button
Would you like to use previous values? [Yes | Reset All]
To exit Auto Setup, press
Press UP/DWN to select. Press MENU. (Resetting defaults and Password).
Press MENU.
INTELLICHEM® Controller Installation and User’s Guide
7
Auto Setup Sequence (Continued)
What is your
What size is the
Hardware Setup? body of water?
pH
ORP Volume: 10.0K
[L_Pump R_pump] Units: gal-US
How long does What is the pH
your filter run? Daily:H:08 M:00
Container Size? 4.00 gal-US
Gauge: 6
Press the / Up/Down arrow button to Press the MENU Enter Container Size info.
scroll through the controller configurations. select next screen Press MENU. “Is your pool water balanced?
What is your
What size is the How long does What is the pH
Hardware Setup?
pH
ORP
body of water? Volume: 10.0K
your filter run? Container Size? Daily: H:24 M:00 1.0 gal-US
[L_Pump ICHLOR] Units: gal-US
Gauge: 6
What is your
What size is the
Hardware Setup?
pH
ORP
body of water? Volume: 10.0K
[L_Pump EX_IC*] Units: gal-US
How long does your filter run?
Daily: H:24 M:00
What is the pH Container Size?
1.0 gal-US Gauge: 6
What is your
Enter doser pump
Hardware Setup? rated output for
pH
ORP ORP: 50 GPD
[L_Pump RELAY1]
What size is the body of water?
Volume: 10.0K Units: gal-US
How long does your filter run?
Daily: H:08 M:00
(*) EX_IC: IntelliChlor® Salt Chlorine Generator (Commercial model only) Output on RELAY #1. EX_IC also set ORP sensitivity = Off, whereas other cases are LOW. Selects Dose-by-Time, Dose Time set to 24:00:00 (all day) Removes container gauge. Turns off supply reminder (Default).
What is the pH Container Size? 4.0 gal-US Gauge: 6
Enter Container Size info. Press MENU. “Is your pool
water balanced?
What is your
Enter doser pump
What size is the
Hardware Setup? rated output for
body of water?
pH
ORP pH: 50 GPD (1-400) Volume: 10.0K
[RELAY2 ICHLOR]
Units: gal-US
How long does your filter run?
Daily: H:08 M:00
Select “Use Time” (“0”) if the doser pump’s GPD (gallons-pe r-day) feed rate is
What is the pH Container Size? 1.0 gal-US Gauge: 6
What is your
Enter doser pump What size is the
Hardware Setup? rated output for body of water?
pH
ORP pH: 50 GPD
Volume: 10.0K
[RELAY2 EX_IC] ORP: 50 GPD
Units: gal-US
How long does your filter run?
Daily: H:08 M:00
What is the pH Container Size? 4.00 gal-US Gauge: 6
Enter ORP MENU. “Is
info. Press your pool
Continue on next page.
water balanced?
INTELLICHEM® Controller Installation and User’s Guide
8
Auto Setup Sequence (Continued)
What is your
Enter doser pump
What size is the
Hardware Setup? rated output for
body of water?
pH
ORP pH: 50 GPD (1-400) Volume: 10.0K
[RELAY2 RELAY1] ORP: 50 GPD
Units: gal-US
How long does your filter run?
Daily: H:08 M:00
[RELAY2 DUAL] [CO2/R2 ICHLOR]
What is your
Hardware Setup?
pH
ORP
[CO2/R2 L_PUMP]
How long should CO2 dose be H:00 M:05 S:40
What is the pH Container Size? 1.0 gal-US Gauge: 6
What size is the
body of water? Volume: 10.0K
Units: gal-US
Enter Container size info. Press MENU. “Is your pool water balanced?
How long does
your filter run? Daily: H:08 M:00
pH Chem Reminder in:
H:00 M:00
What is the pH Container Size?
1.0 gal-US Gauge: 6
What is your
Hardware Setup?
pH
ORP
[CO2/R2 ICHLOR]
How long should each CO2 dose be?
H:00 M:05 S:00
What size is the body of water? Volume: 10.0K Units: gal-US
How long does your filter run?
Daily: H:08 M:00
How long does
your filter run?
Daily: H:08 M:00
What is your
How long should
Hardware Setup? each CO2 dose be
pH
ORP
00:00:00
[CO2/R2 EX_IC]
pH Chemical Reminder in:
H: 100 M: 00
What size is the body of water?
Volume: 10.0K Units: gal-US
Enter Reminder info. Press MENU. “Is your pool water balanced?
How long does your filter run?
Daily: H:08 M:00
HopwHlConhgemdoceasl yoRuer mfilitnerdreurni?n: DailyH: :H0:008MM:0:000
Enter Reminder info. Press MENU. “Is your pool water balanced?
What is your
Enter doser pump
Hardware Setup? rated output for
pH
ORP
ORP: 50 GPD
[CO2/R2 RELAY1]
How long should
What size is the
each CO2 dose be body of water?
00:00:00
Volume: 10.0K
Units: gal-US
HHoowwlolonnggddooeess
yyoouurrfiflitleterrrruunn?? DDaailiyly::HH:0:088 MM:0:000
HpHowClhoenmgcdaol es yRoeumr ifnildteerr rinu:n?
DaHily:1: 0H0:0M8:0M0:00
What is the ORP Container Size?
4.00 gal-US
Gauge: 6
INTELLICHEM® Controller Installation and User’s Guide
Enter Container size info. Press
MENU. “Is your pool water balanced?
Continue on next page.
9
Auto Setup Sequence (Continued)
Is your pool water balanced?
[No] YES Finished Setup. Verify your new settings in the pH & ORP menus!
Balance water chemistry before
beginning automatic control
NO
Note: The units used for dose size in the main menus will automatically be set
to milliliters(ml) if either the pool volume is set to less than 4k gallons or
the container size is specified in liters. Note: 1 oz = approximately 3 ml.
IntelliChem Controller System Default Values
pH pH Set Point: pH Alarm High: pH Alarm Low: pH Alarm Delays: Sensitivity:
ORP ORP Set Point: ORP Alarm High: ORP Alarm Low: ORP Alarm Delays:
Sensitivity: pH Lockout:
Miscellaneous Default Values Display Mode: Control Panel LED Brightness: Menu
Timer: Menu Backlight Timer: Power-On Delay: Flow Switch Delay: Dose Priority:
Password 1234 – Lock = Off
7.5 7.8 6.8 5 min. for both Low (Off for CO2)
700 750 650 5 min. for both Low (Off for IntelliChlor® Salt Chloriine
Generator) 7.8
Basic 10% M:02 S:30 M:00 M:20 14 minutes 1 minute Simultaneous dosing
INTELLICHEM® Controller Installation and User’s Guide
10
MENUS
MAIN SCREEN
PH MENU (page 11)
pH Dosage (Page 1/2) Dosage (For liquid; Volume/Time): (For CO2; Time or to set point): Mixing Time: H:24 M:59 pH Dose by Volume (Page 2/2) Dose: [0-9999], Limit: [0-64350], Units: [oz/ml], Clear [Manual] pH Dose by Time (Page 2/2) Dose: [00:00:00], Limit: [00:00:00], Clear: [Power-On] pH Dose to Setpoint (Page 2/2) Limit: [00:00:00], Clear: [24hr Flow] pH Setpt: 7.5 (use Left/Right button to adjust pH set point) pH Tweak – reading = 7.xx tweak: 0.0 (+/- 0.3) pH Supply (Page 1/2) Units: gal-US/gal-UK/Liters/Time, Chemical: [Acid, pH-, Base, pH+] Page 2/2 – Capacity: 0.000-200.00 gal-US/galUK/Liters – Gauge: Egg timer or tank gauge Page 2/2 Time: Reminder in: H:100 M:00 Sensitivity: – [Low/High/Off] – Full Dose at 0.5pH (Low – Liquid, CO2), (High 0.2pH from set point). pH Alarms: Page1/2 High 7.8 – Delay 00:05:00 – Page 2/2 Low: 6.8 Delay 00:05:00
ORP MENU (page 14)
ORP Dosage (Page 1/2) Dosage (For liquid; Volume/Time): (For SCG; Time or to set point): Mixing Time: H:24 M:59 ORP Dose by Volume (Page 2/2) Dose: [0-9999], Limit: [0-64350], Units: [oz/ml], Clear [Manual] ORP Dose by Time (Page 2/2) Dose: [00:00:00], Limit: [00:00:00], Clear: [Power-On] ORP Dose to Setpoint (Page 2/2) Limit: [00:00:00], Clear: [24hr Flow] ORP Setpt: 700 (use Left/Right button to adjust ORP set point) ORP Tweak – reading = xxx tweak: 0.0 (+/- 50mV) ORP Supply (Page 1/2) Units: gal-US/gal-UK/Liters/Time, Chemical: [Chlorine/Bromine] Page 2/2 – Capacity: 0.000-200.00 gal- US/galUK/Liters – Gauge: Egg timer or tank gauge Gauge: Egg Timer or tank gauge – Page 2/2 Time: Reminder in: H:100 M:00 Sensitivity: – [Low/High/Off] – Full Dose at 50 mV ORP (Low – Liquid), (High 20 mV from set point, Off (IntelliChlor OFF) ORP Alarms: Page1/2 High 750 – Delay 01:00:00 – Page 2/2 Low: 650 Delay 02:00:00
SAT INDEX See page 24 for details – pH: 7.5 – Temp: 00°F – CH: xxx – SLT: xxx
– TA:xx = CYA: xx Recalc/Tab:
AUTO SETUP See page 6 for details
CONFIGURATION
(page 17)
Pool Details:Volume: 0.2K-230K (200-230,000 Liters max) Units: Gal US (gal-US /gal-UK/Liters), Daily Hrs/Mins Display Mode: Display Mode: Basic/Advanced, Brightness Front LEDs: (0-100%), Menu/BkLt Hrs/Mins. (24 hrs -30sec.) Delays: Power-on: 1-60 mins. (15min default) – FlowSwitch: 1-60 mins. (1 min default) Doser/Probe: Seconds 0,15,30,60secs. Set Password: PW [1234] – Lock [OFF/MENU/ALL] Preferences: pH Lockout: 7.8, Preferences 2/2: Saturation Index, Alarm: +/- 0.3, Dose Priority: [Simultaneous pH Priority] Diagnostics: Software Rev, Meter Test {Auto Calibration), Probe Test (Open Probe Test) Timers, Chlorinator, Status Codes, Factory Reset, Self Test Sequence Hardware: pH Control: 1/2 Doser Type [Internal Pump, External/Relay, CO2 Ext/Relay, None] – pH Control 2/2 Flow: xx GPD See page 22 for details
INTELLICHEM® Controller Installation and User’s Guide
11
Navigating IntelliChem® Controller Menus
The following examples show how to navigate the main menus and sub-menus. Press the MENU button to access the main menu. Press the Right arrow button to select a menu item and select items in a sub-menu. Press / to select previous/next item on a page. To change a menu setting or value press the / Up/Down arrow button.
Press the MENU button to exit and return to the previous menu items. Note: Settings are
automatically save when changed.
Example: To change the pH dosage settings (pH Dosage screens 1/2 and 2/2):
Press MENU / pH Menu pH Dosage
pH Menu ORP Menu Saturatn Index Auto Setup
1. 2.
Press the / Up/Down arrow button to scroll through the main menu items. For
this example choose pH menu.
Press the Right arrow button to select the
ORP Menu Saturatn Index Auto Setup Configuration
pH menu.
Press arrow button to select pH Dosage (page 1 of 2). Press / to toggle
between pH Dosage page 1/2 and page 2/2.
pH Dosage pH Setpt: 7.5 pH Tweak pH Supplies
pH Dosage
1/2
Dose: by Volume
Mixing Time:
H:00 M:59
4. From pH Dosage page 1/2, press the to select Dose (feed method). To change
the feed method press / to change the selection: “by Volume” or “by Time”.
5. Press the to select the next item. The cursor moves down to the “Mixing
Time” hours setting (H:00).
6. Press the / to adjust the Mixing Time hours between feeding acid. Press to
select the
pH Dosage
2/2
Dose Limit Units
3 21 [oz]
Clear [Power-On]
minutes. Press / to adjust the minutes. After adjustment, the
display shows the new setting. Note: Press either / button to scroll forward
or backwards within
this sub-menu.
7. Select 1/2 page indicator. Press the / buttons to
select the next pH Dosage screen (2/2).
pH Dosage
1/2
Dose: by Volume
Use / buttons and / buttons to select and
Mixing Time:
change the “Dose” (amount of liquid dispensed
H:09 M:59
before waiting for a mix time), Limit (amount of
pH Menu ORP Menu
liquid dispensed in one day, Units (apply to dose and limit) and clear dose limits setting.
Auto Setup
9. Press the MENU to return to the previous pH
Configuration
Dosage page 1/2 menu items.
pH OK 7.46 Mixing 00:07:03
ORP OK 450 Mixing 00:07:54
10. Press the MENU again to exit pH Dosage menu.
Note: All settings are immediately save when changed.
INTELLICHEM® Controller Installation and User’s Guide
12
pH Menu Description
pH Menu ORP Menu Saturatn Index Configuration
pH Dosage pH Setpt: 7.2 pH Tweak pH Supplies
pH Dosage
1/2
Dose: by Time
Mixing Time:
H:00 M26
by Volume
pH Dosage
2/2
Dose Limit Units
1200 64100 [mL]
Clear [Manual]
by Time
pH Dosage
2/2
Dose 00:33:45
Limit 04:14:00
Clear [Power-On]
by Setpoint
pH Dosage
2/2
Dose to Setpoint
Limit 00:08:00
Clear [24hr ]
To access the pH Menu: Press MENU pH Menu pH Dosage – The ph Dosage
screen 1/2 displays the current dose method (by Volume, Time or to Setpoint).
pH Dosage (for Internal and External Pumps) pH Dosage (page 1/2)
Mixing Time: Select the amount of time in hours and minutes that the
IntelliChem® Controller will wait in between pH feeding. It should be set to
allow sufficient mixing time for the chemicals to become distributed
throughout the pool. The pH Mixing Time is set by Auto Setup.
Dose (by Volume/Time): Choose the feed method: “by Volume” and “by Time” are
available choices for liquid dosers, as determined by the hardware setup. If
CO2 is selected, then the available choices are “by Time” and “To Setpoint”.
If pool volume is less than 4k gallons, these units automatically get set to
milliliters (ml) for better resolution.
pH Dosage (page 2/2)
Dose (Volume): Displays the current dose size (0-9999) in ounces [oz] or
milliliters [ml]. Set the amount of ounces (or milliliters) that the
IntelliChem controller will feed pH (acid) each time the IntelliChem
controller calls for pH chemicals. The Dose (Volume) is set by Auto Setup
wizard based on pool volume and filter run time.
Dose (Time/Setpoint): Displays the current pH dose (feed) time. If pool volume
is less than 4k gallons, these units automatically get set to milliliters (ml)
for better resolution. Sets the amount of time in hours, minutes and seconds
that the IntelliChem controller will feed pH (acid) each time the IntelliChem
controller calls for pH chemicals. The pH dose time is set by Auto Setup. The
Dose (Time) is set by Auto Setup wizard based on pool volume and filter run
time. Dose (to Setpoint) does not have a dose amount, only a time limit.
Limit (Time/Volume): Displays the current feed limit. Sets the maximum amount
of time/volume in hours, minutes and seconds or volumetric units that will be
allowed to feed pH chemicals. As a safety feature, the IntelliChem controller
will only allow a certain amount of pH chemicals to feed into the system in a
24 hour period. Set the maximum amount of time in hours (0-24) that will be
allowed to feed. The IntelliChem controller tracks each dose time, and adds
them together. When the maximum dose time is reached or exceeded, the ORP feed
system is prevented from feeding until the next 24 hour period begins, or when
the feed timers are cleared manually. The default pH Limit is based on a safe
limit of 2 ppm of the size of the pool, up to a 5 oz maximum. The Limit
(Time/Volume) is set by Auto Setup wizard based on pool volume and filter run
time.
Continue on next page.
INTELLICHEM® Controller Installation and User’s Guide
13
pH Menu Description (Continued)
pH Dosage (page 2/2) Continue
Clear: Select Power-On to clear the pH dose limit time when IntelliChem®
Controller is powered on. Select Manual to manually clear the pH dose limit
timers and select 24 Hrs to clear timers automatically each 24 hour period of
continuous operation. To protect the pool water, IntelliChem controller will
automatically shutdown pH and ORP feed control and display an alarm message if
IntelliChem controller (or any other dispensing device) runs non-stop for more
than the selected Limit time or volume. This prevents IntelliChem from non-
stop feeding pH reducer, because of a sensor error or external problem with
the pool. This allows you to evaluate the pool chemistry before continuing
with pH feeding.
pH Set Point
Displays the current pH set point value. Adjust the pH set point to meet pool
and spa chemistry standards. The adjustable range is from 7.2 to 7.6 in
increments of 0.1. The default pH set point value is 7.5.
To adjust the acid feed pH set point: Press MENU pH Menu pHSetpt Press / to
decrease or increase the current pH set point value. Note: When using CO2,
parameters are the same as above.
pH Tweak
The exact reading of each individual pH sensor can vary because of water
makeup and variances in probe condition age, etc. The pH Tweak menu feature
allows you to adjust the pH sensor reading to match the manual reading taken.
The adjustable range is +/- 0.3. After adjusting the pH value, the main screen
should now display the same value as the manual reading. To adjust the pH
sensor level: Press MENU / pH Menu pH Tweak The current value is displayed
(reading = x.xx). Press / to adjust the pH sensor level (+/- 0.3). To remove
the tweak, set the level back to 0 (zero).
pH Supplies
pH Supply (page 1/2) Units: Select gal-US, gal-UK, Liters or Time (hours/minutes)*. Chemical: Use Acid, (pH -) or Base (pH+).
pH Supply Unit: USGal Chemical: [Acid, pH-]
1/2 pH Supply
2/2 pH Supply
2/2
Capacity:
Reminder in:
4.00 gal-US
H:1000 M:00
Gauge:
3 Gauge:
6
pH Supply (page 2/2) Capacity: Select from 0 to 200 maximum gal-US, gal-UK, or Liters.
*Time (Reminder in: H:xxx M:xx) If the supply Units were set to Time, the Capacity feature becomes a Reminder feature, as in an egg-timer. This can be used to trigger an alarm, based on cumulative feed times as to when to check the CO2 cylinder. Set the reminder time in hours (0-8760) and minutes (00-59) on ORP Supply page 2/2. Note: Entering the hours and minutes time (H:00 M:00) will display the hour glass icon on the main screen.
Level Gauge (liquid only): Displays level gauge when using liquid chemical
doser. Tank icon symbol is used for liquid chemical configurations that
include valid supply and doser feed rate information.
INTELLICHEM® Controller Installation and User’s Guide
14
pH Menu (Continued) pH Sensitivity
The IntelliChem® Controller can adjust the feed times for pH depending on how
close the current reading is to the set point. This helps to prevent
overshooting and makes it easier for the IntelliChem controller to reach the
exact set point. Note: Low = (default) Full dose at 0.5 pH above setpoint.
High = Full dose at 0.2 pH above setpoint. Off = Full dose at 0.005 pH above
setpoint For example: When set to LOW (full dose at 0.5 above setpoint), if pH
setpoint is 7.2 and pH reading is 7.7 or above, a full dose amount is
dispensed. As the pH comes closer to setpoint, say 7.45 (0.25 above setpoint –
or- half the 0.5 pH value), the dispensed amount will be 1/2 of the specified
dosage. And, at 0.05 (1/10th of 0.5 value) above setpoint (7.25), the dosage
will be 10% of that specified in the dosage menu. In that case, if the dosage
was specified to be 10 ounces, IntelliChem controller will dispense only 1
ounce at a time. This can be confusing because the display appears to not be
dosing the full amount; therefore, in the Advanced display mode, the process
timer shows “%Dosing 0.1 oz”, the “%” indicates the dosage is reduced due to
this Sensitivity feature. In SPA Mode, the leading “s” in “sDosing 0.1 oz”
indicates the dose is further reduced by 25%.
To set the pH Sensitivity level: Press MENU – pH Menu / pH Sensitivity
pH Sensitive – Monitoring in SPA Mode (Dosing)
pH >OK 7.28 Monitoring
pH OK 7.25 sDosing 0.1 oz
The Advanced display mode shows the current pH dosage. If both SPA Mode and %Sensitivity are active, the Advanced display screen will alternate between the two screens. “Dosing” message is preceded with an “s” to indicate automation is in
pH >OK 7.28
SPA mode and the doses are cut to 25%.
Monitoring pH OK 7.25 %Dosing 0.1 oz
“Dosing” is preceded with a “%” to indicate the dosage is being reduced through the Sensitivity feature.
Spa Mode is activated when the IntelliChem Controller detects that the control system has turned on the Spa. The SPA indicator should be illuminated on the automation control panel. Switching from a large body of water like a pool to a typically a smaller spa automatically reduces the dispensed dosage to 25% of a normal dose. The IntelliChem’s Advanced display precedes the Dosing message with a “s” to indicate it is in this mode. This feature is only available if the IntelliChem Contrroller is connected to a Pentair control system.
pH Alarms
The IntelliChem controller automatically displays a screen message indicating
the pH level has reached or exceeded the HIGH (7.8) or LOW (6.8) pH alarm
level settings. The IntelliChem controller will automatically set a high and
low alarm for the pH level. The Delay time is the amount of time between the
detected alarm condition and when the IntelliChem controller displays the
alarm message on the main screen. The Delay setting is adjusted in increments
of 15 seconds.
To set the pH alarm “High” level and “Delay” time (page 1/2): Press MENU pH
Menu pH Alarms / pH Alarms / (page 1/2 is High Level Alarm, page 2/2 is Low
Level Alarm) Press to select the alarm, High level and Delay Time (00:50:00).
To set the pH alarm “Low” level and “Delay” time (page 2/2): Press MENU / pH
Menu pH Alarms / Low / Delay (2/2) Press / to change pH alarms Low level and
Delay Time (00:05:00). INTELLICHEM® Controller Installation and User’s Guide
15
ORP Menu Description
ORP Dosage (dispense chlorine or bromine)
pH Menu ORP Menu
Saturatn Index Configuration
ORP Dosage
ORP Dosage
1/2
ORP Setpt: 700
Dose: by Time
ORP Tweak
Mixing Time:
ORP Supply
H:00 M26
by Volume
by Time
by Setpoint
ORPDosage
2/2
Dose Limit Units
1200 64100 [mL]
Clear [Manual]
ORPDosage
2/2
Dose 00:33:45
Limit 04:14:00
Clear [Power-On]
ORPDosage
2/2
Dose to Setpoint
Limit 00:08:00
Clear [24hr ]
To access the ORP Menu: Press MENU ORP Menu ORP Dosage – The
ORP Dosage screen 1/2 displays the current dose method (by Time or to Setpoint).
ORP Dosage (for Internal and External Pumps)
ORP Dosage (page 1/2)
Mixing Time: Select the amount of time in hours and minutes that IntelliChem
will wait in between ORP dosing. It should be set to allow sufficient mixing
time for the chemicals to become distributed throughout the pool. The ORP
Mixing Time is set by Auto Setup.
Dose (by Volume/Time): Choose the feed method: “by Volume” and “by Time” are
available choices for liquid dosers, as determined by the hardware setup. If
IntelliChlor (SCG) is selected, then the available choices are “by Time” and
“To Setpoint”.
ORP Dosage (page 2/2)
Dose (Volume): Displays the current dose size (0-9999) in ounces [oz] or
milliliters [ml]. Set the amount of ounces (or milliliters) that IntelliChem
will dose ORP (chlorine/bromine) each time IntelliChem calls for ORP
chemicals. The Dose (Volume) is set by Auto Setup wizard based on pool volume
and filter run time. If pool volume is less than 4k gallons, these units
automatically get set to milliliters (ml) for better resolution.
Dose (Time/Setpoint): Displays the current ORP dose (feed) time. If pool
volume is less than 4k gallons, these units automatically get set to
milliliters (ml) for better resolution. Sets the amount of time in hours,
minutes and seconds that IntelliChem will feed ORP (chlorine/bromine) each
time IntelliChem calls for ORP chemicals. The ORP dose time is set by Auto
Setup. The Dose (Time) is set by Auto Setup wizard based on pool volume and
filter run time. Dose (to Setpoint) does not have a dose amount, only a time
limit.
Limit (Time/Volume): Displays the current feed limit. Sets the maximum amount
of time/volume in hours, minutes and seconds or volumetric units that will be
allowed to feed ORP chemicals. As a safety feature, the IntelliChem will only
allow a certain amount of ORP chemicals to feed into the system in a 24 hour
period. Set the maximum amount of time in hours (0-24) that will be allowed to
feed. IntelliChem tracks each dose time, and adds them together. When the
maximum dose time is reached or exceeded, the ORP feed system is prevented
from feeding until the next 24 hour period begins, or when the feed timers are
cleared manually. The default ORP Limit is based on a safe limit of 2 ppm of
the size of the pool, up to a 5 oz maximum. The Limit (Time/Volume) is set by
Auto Setup wizard based on pool volume and filter run time.
Clear: Select Power-On to clear the ORP dose limit time when IntelliChem is
powered on. Select Manual to manually clear the ORP dose limit timers and
select 24 Hrs to clear timers automatically each 24 hour period of continuous
operation.
INTELLICHEM® Controller Installation and User’s Guide
16
ORP Menu Description (Continued)
ORP Set Point
Displays the current ORP set point value. Adjust the ORP set point to meet
pool and spa chemistry standards. The adjustable range is from 400 to 800 in
increments of 10. The default ORP set point value is 700. To adjust the ORP
set point: Press MENU ORP Menu ORP Setpt Press / to decrease or increase the
current ORP set point value. Note: When using IntelliChlor SCG, parameters are
the same as above.
ORP Tweak The exact reading of each individual ORP sensor can vary because of
water makeup and variances in probe condition age, etc. The ORP Tweak menu
feature allows you to adjust the ORP sensor reading to match the manual
reading taken. The adjustable range is +/50mV. After adjusting the ORP value,
the main screen should now display the same value as the manual reading.
To adjust the ORP sensor level: Press MENU / pH Menu ORP Tweak The current
value is displayed (reading = x.xx). Press / to adjust the ORP sensor level
(+/- 50 mV). To remove the tweak, set the level back to 0 (zero).
ORP Supplies
ORP Supply (page 1/2) Units: Select gal-US, gal-UK, Liters or Time
(hours/minutes)*. Chemical: Use Chlorine or Bromine.
ORP Supply Unit: USGal Chemical: [Chlorine]
1/2 ORP Supply
2/2 ORP Supply
2/2
Capacity:
Reminder in:
4.00 gal-US
H:1000 M:00
Gauge:
3
Gauge:
6
ORP Supply (page 2/2) Capacity: Select from 0 to 200 maximum gal-US, gal-UK,
or Liters.
*Time (Reminder in: H:xxx M:xx) If the supply Units were set to Time, the Capacity feature becomes a Reminder feature, as in an egg-timer. This can be used to trigger an alarm, based on cumulative feed times as to when to clean the SCG plates. Set the reminder time in hours (0-8760) and minutes (00-59) on ORP Supply page 2/2. Note: Entering the hours and minutes time (H:00 M:00) will display the hour glass icon on the main screen.
Level Gauge (liquid only): Displays level gauge hour when using liquid
chemical doser. Tank icon symbol is used for liquid chemical configurations
that include valid supply and doser feed rate information.
INTELLICHEM® Controller Installation and User’s Guide
17
ORP Menu Description (Continued)
ORP Sensitivity
IntelliChem® Controller can adjust the feed times for ORP depending on how
close the current reading is to the set point. This helps to prevent
overshooting and makes it easier for IntelliChem controller to reach the exact
set point. Note: Low= (default) Full dose at 50mV below setpoint. High= Full
dose at 20mV below setpoint Off= Full dose at 1mV below setpoint
For example: When set to LOW (full dose at 50mV below setpoint), if ORP
setpoint is 700 and ORP reading is 650 or below, a full dose amount is
dispensed. As the ORP comes closer to setpoint, say 675mV (25mV below setpoint
– or- half the 50mV value), the dispensed amount will be 1/2 of the specified
dosage. And, at 695 (1/10th of 50mV value) below setpoint (700), the dosage
will be 10% of that specified in the dosage menu. In that case, if the dosage
was specified to be 10 ounces, the IntelliChem controller will dispense only 1
ounce at a time. This can be confusing because the display appears to not be
dosing the full amount; therefore, in the Advanced display mode, the process
timer shows “%Dosing 0.1 oz”, the “%” indicates the dosage is reduced due to
this Sensitivity feature.In SPA Mode, the leading “s” in “sDosing 0.1 oz”
indicates the dose is further reduced by 25%. To set the ORP Sensitivity
level: Press MENU – ORP Menu / ORP Sensitivity
ORP Sensitive – Monitoring in SPA Mode (Dosing)
ORP >OK 7.28 Monitoring
ORP OK 652
The Advanced display mode shows the current ORP dosage. If both SPA Mode and %Sensitivity are active, the Advanced display screen will alternate between the two screens. “Dosing”
sDosing 0.1 oz
message is preceded with an “s” to indicate automation is in
ORP >OK 7.28
SPA mode and the doses are cut to 25%.
Monitoring ORP OK 652
“Dosing” is preceded with a “%” to indicate the dosage is being
%Dosing 0.1 oz
reduced through the Sensitivity feature.
Spa Mode is activated when the IntelliChem Controller detects that the control system has turned on the Spa. The SPA indicator should be illuminated on the automation control panel. Switching from a large body of water like a pool to a typically a smaller spa automatically reduces the dispensed dosage to 25% of a normal dose. The IntelliChem’s Advanced display precedes the Dosing message with a “s” to indicate it is in this mode. This feature is only available if the IntelliChem Contrroller is connected to a Pentair control system.
ORP Alarms
IntelliChem automatically displays a screen message indicating the ORP level
has reached or exceeded the HIGH (750 mV) or LOW (650 mV) pH alarm level
settings. IntelliChem will automatically set a high and low alarm for the ORP
level. The Delay time is the amount of time between the detected alarm
condition and when IntelliChem displays the alarm message on the main screen.
The Delay setting is adjusted in increments of 15 seconds. To set the ORP
alarm “High” level and “Delay” time (page 1/2): Press MENU ORP Menu ORP Alarms
/ ORP Alarms / (page 1/2 is High Level Alarm, page 2/2 is Low Level Alarm)
Press to select the alarm, High level and Delay Time (00:50:00). To set the
ORP alarm “Low” level and “Delay” time (page 2/2):
Press MENU / ORP Menu ORP Alarms / Low / Delay (2/2) Press / to change ORP
alarms Low level and Delay Time (00:05:00).
INTELLICHEM® Controller Installation and User’s Guide
18
Configuration Menu Pool Details From this menu, you can set your pool size,
units to display and the daily run time which should match your daily pool
pump filtration time. Volume: Pool volume (size). Select range is 200 –
230,000 gal (gal-US, gal-UK and Liters). Units: Select units to display in
English (gal-US), (gal-UK) and Metric Liters. Daily: This daily run time is
used for calculating dose and mix times. It is set and used in the Auto Setup
script and should be the amount of time the pool pump/filter runs each day. To
access the Pool Details menu: Press MENU Configuration Pool Details
Display Modes
Mode: Selects which display mode is displayed: Basic or Advanced, Basic mode
displays the current pH and ORP levels with any alarms and fuel gauge if
enabled. Advanced mode displays high resolution pH and ORP levels and process
messages, timers (see page 6). LEDs: Adjusts the brightness level (0-100%) of
the front panel LEDs. Menu: Adjusts the amount of time (minutes/seconds) the
menu will be on each time the control panel is activated and also the time the
entered password is valid. BkLt: Adjusts the amount of time (hours/minutes)
the controller screen backlight will be on each time the control panel is
activated. To access the display mode menu: Press MENU Configuration Display
Press / to adjust display settings.
Delays (minutes) Power-On: Sets the delay time from power up to the first
display screen reading. The adjustable time is from 1 to 60 minutes. The
default power on time is 14 minutes Flow Switch: Sets the delay time from when
the Flow Switch is active to the first display screen reading. The adjustable
time is from 1 to 60 minutes. The default flow switch delay time is one
minute. Doser/Probe: Sets the delay time from when the Doser turns on to when
it takes the next probe measurement. Adjustable time is 0 to 60 seconds.
Default is 15 seconds. Use longer times to prevent interaction of doser from
affecting the measurement. To access the delays menu: Press MENU Configuration
Delays Press / to set the delay settings.
INTELLICHEM® Controller Installation and User’s Guide
19
Configuration Menu (Continued) Set Password The IntelliChem® Controller menus,
the pH button and ORP button on the control panel can be password protected.
Once a password has been set, the IntelliChem controller will not allow access
to the menu system and no changes to be made without entering the password.
For more information see page 5. PW: Enter a four digit password [0000]. Each
digit can be assigned 0-9. Lock: Select OFF, MENU (password protect the main
menu) or ALL (password protect all control panel buttons. Once the password is
entered, access is granted for the duration specified by the Menu timeout
setting in the Configuration/Display Mode menu. If the menus are locked,
changes via the automation interface will also be locked out. To access the
password menu: Press MENU Configuration Set Password Press / to select the
digit and / move to next digit. Note: If you forget the password, first try
the default password 1234, then call Customer Support for assistance.
Preferences (1/2) To access the delays menu: Press MENU / Configuration
Preferences Press / to adjust the following settings.
Preferences 1/2 pH Lockout: 7.8
pH Lockout: is the pH reading at which IntelliChem will no longer dose
sanitizer (Chlorine/ Bromine). Above pH of 7.8 it is generally understood that
the ORP reading is suppressed and therefore will not be used to administer
additional sanitizer. Just bringing the pH level down will raise the available
chlorine and the effective ORP. At this trip point, an alarm message will be
shown on the screen and ORP doses will cease. Range is 7.7 to 8.2, default is
7.8.
INTELLICHEM® Controller Installation and User’s Guide
20
Configuration Menu (Continued)
Preferences (2/2)
Preferences
2/2
Saturation Index
Alarm: +/- 0.5
Delay: 00:30:0
Saturation Index Alarm: +/- 0.5: If the Saturation Index (SI) level is in the “Corrosive” or “Scaling” range, this feature allows you to enter a Saturation Index (SI) alarm threshold value between +/- 0.1 to +/- 0.9 (+/- 5 default). Select “Disabled” to disable the Alarm feature.
Delay: The Alarm Delay feature sets the delay time before the SI Alarm (see above) message is displayed. Enter the delay time from 00:15:00 to 24:00:00 (30 minutes default). Note: Once the SI has passed the threshold for the delay period, an alarm message is displayed showing the Saturation Index Alarm (along with other pH alarms) that includes the value and description.
pH >OK 7.44 -.72 Corrosive
ORP OK 730 Monitoring
pH >OK 7.44 +.32 Scaling
ORP OK 730 Monitoring
These alarm messages are also displayed on the IntelliTouch, EasyTouch and SunTouch control panel.
Dose Priority To access the delays menu: Press MENU / Configuration Dose
Priority Press / to select option.
Dose Priority: pH Priority or Simultaneous. Depending on how the IntelliChem
chemical dosers are plumbed and how much water is circulating in the system
where the chemicals are injected into the water stream, it may be preferred to
only feed Chlorine when Acid is not feeding. This would be the pH Priority
setting.
· Simultaneous allows both chemicals to feed at the same time – and
can be used when both feed systems are not liquid chemicals or the injectors
are separated by a safe distance in the water stream. DANGER: Combining liquid
acid and chlorine can result in the formation of hazardous and explosive gas.
· pH Priority will always feed acid first, and only during the acid mix time
or general monitoring period will the IntelliChem feed the liquid chlorine
sanitizer. If while feeding chlorine, the pH rises above setpoint, the ORP
dose will be stopped and allow acid to feed.
INTELLICHEM® Controller Installation and User’s Guide
21
Configuration Menu (Continued)
Diagnostics
Software Rev: Displays the software revision.
Meter Test: Performs an internal self-test of the pH/ORP meter and sensing circuitry. Ensures both circuits are performing properly First tests the High circuit in the uncalibrated state, waits for a button press, then tests the Low circuit and waits for a button press. Once these two tests complete, it proceeds with the self-calibration. A Pass or Fail message is displayed. If this test fails, disconnect power and check for water or dirt on the circuit board. Use a can of dry compressed air to clean the board if necessary. If the test continues to fail, contact technical support.
Probe Test: This test takes approximately 30 seconds. Perform this test with the sensor cables and probes installed. Probes must be clean and in water. Possible results are :
Both Probes Good
pH: Good
ORP:Bad
pH: Bad
ORP:Good
pH: Bad
ORP:Bad
Timers: This displays the counters used for tracking the cumulating dose
volume and/or time used in determining the Dose Limit. It shows:
“PCs” PH cumulative dose limit timer in Days HH:MM:SS
“Ocs” ORP cumulative dose limit timer in Days HH:MM:SS
“ml” Milliliters of cumulative dose for Ph and Orp (0-9999) stops at 9999 ml
“Run” the RUN TIME in Days, HH:MM:SS since powered up.
If you need to know how much you’ve dosed during a day, or how long its been
running that day, “Timers” will have this information. The cumulative times/ml
get reset when you clear the dose limits, The Run Time clears on power-up.
INTELLICHEM® Controller Installation and User’s Guide
22
Configuration Menu (Continued)
Diagnostics (Continued)
Chlorinator: This screen displays the current IntelliChlor (SCG) status, salt
(ppm) levels and error conditions. The hexadecimal status value is decoded and
displayed in the brackets on the bottom line; multiple error conditions are
shown by sequencing through the messages. This display can be used to
determine if the SCG is connected and responding to the IntelliChem. If the
IntelliChlor is connected, this display may show “Please wait 2-7 minutes for
ppm”. This indicates the IntelliChlor is responding to initial contact but
until water flow and sufficient salt level is reached, the IntelliChlor will
not respond with further information like salt ppm and status. Sometimes it is
helpful to cycle power on the IntelliChlor and wait 10 minutes for the green
lights before it will respond with ppm and status information; it may not
respond if the Salt or Cell lights are flashing red. If the Configuration /
Hardware / ORP Control / Doser Type is set to IntelliChlor, the IntelliChem
will control the IntelliChlor as it would a doser, actively turning it on
(100%) for chlorine demand, and off (0%) when the ORP reaches the desired set
point. For the Chlorinator to work when connected to an Automation controller
like the IntelliTouch, EasyTouch, or SunTouch, those units must be configured
with the IntelliChlor enabled. The displays is as follow:
————————————-Chlorinator Info: Salt: 4500 ppm Status Code=00H [OK-NO ERRORS ]
V ————————————-To get updated ppm, cycle SCG power and wait. Press any button
————————————-Possible messages are: No Flow Low Salt Very Low Salt High
Current Clean Cell Low Voltage Cold Water
INTELLICHEM® Controller Installation and User’s Guide
23
Configuration Menu (Continued)
Status Codes: This displays a complex series of values that indicate the real-
time status and alarm conditions.
Top line, Codes: HA= is the automation Home Address that IntelliChem has
locked onto.
In the upper-right corner,
R0,1,2,4 which represents the UOC comm status. R0 = standalone (no KA from
Automation since power up) R1 = Found KA packets within 30 seconds of power up
R2 = Found KA packets later, after 30 seconds, so was operating in standalone
for a while R4= Was in Automation mode (sending IntelliChlor commands through
IntelliTouch) but has dropped the connection. The two-digit number (0-99)
directly below the R# is the number of seconds it’s gone without a valid KA
packet. It should generally be 00-04 seconds. More than that means that
IntelliChem is missing the automation KA packets.
Note: Status and Alarm hexadecimal displayed codes represent the current
IntelliChem status. For further information, contact Technical Support
800-831-7133.
Factory Reset: Clear all calibrated values and run Auto Setup to initialize IntelliChem. For Factory Default Settings.
Self Test Sequence: Upon entering a self test sequence, all dosing will pause until the test is completed. Follow the on-screen prompts. “PASSED” indicates the test was successful. See Troubleshooting section for error conditions, on page 46.
Hardware Most common hardware configurations can be selected by using the Auto Setup Wizard. This menu allow more complex and custom settings.Use the Hardware menu to configure IntelliChem for the pH and ORP hardware controls and dose being used. Upon entering the hardware setup menu, all dosing will pause until the hardware setup is completed.
After pressing the Hardware
Dosing will
button the following message is displayed.
resume when you exit this menu Press any button
To access the hardware menu: Press MENU Configuration Hardware
pH Control (page 1/2 – 2/2)
Doser Type 1/2: Select the pH Control Dose Type: – IntelliChem pH feed method
being used (INTERNAL PUMP, EXTERNAL RELAY, CO2 EXT/RELAY (Carbon dioxide
tanks), NONE.
Doser Type 2/2: – INTERNAL PUMP: Right, MTR_R, Left, MTR_L – EXTERNAL RELAY:
Ex_Relay 1, Ex_Relay 2 – CO2 EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2
Flow (Rate) 2/2: – INTERNAL PUMP (MTR_R/MTR_L): FLOW: 65 GPD (gallons per
day). – EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set to 0
to use time-based feed instead of volumetric (only on the Ext Relays (not
internal motors). – CO2 EXTERNAL RELAY 1 or 2: Use Time (0) or SCFH (1-400).
INTELLICHEM® Controller Installation and User’s Guide
24
Configuration Menu (Continued) ORP Control (page 1/2 – 2/2) Doser Type 1/2:
Select the ORP control hardware:
– IntelliChem ORP feed method being used (INTERNAL PUMP, EXTERNAL RELAY,
INTELLICHLOR® Salt Chlorine Generator (SCG), NONE.
Doser Type 2/2: – INTERNAL PUMP: Right-Side (MTR_R), Left-Side (MTR_L) –
EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2 – INTELLICHLOR: All Models (IC20, IC40,
IC60)
Flow (Rate) 2/2: – INTERNAL PUMP (MTR_R/MTR_L): FLOW: 65 GPD (gallons per day)
– EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set to 0 to
use time-based feed instead of volumetric (only on the Ext Relays (not
internal motors).
Hardware settings must be chosen carefully. If both dosers are assigned to the
same internal pump or external relay, the program will display an error
message upon exiting the Hardware menu.
Alarm Output Select the following the IntelliChem® Controller alarm output
information:
– External alarm output: Ex_Relay1 or Ex_Relay2.
For an external alarm indicator, an unused relay may be selected to turn on
when the red Alarm LED on the front panel is turned on.
The alarm relay must be chosen carefully. If Ex_Relay1 or Ex_Relay2 is used
for a doser, it must not be used for an alarm output. Upon exiting the
Hardware menu, the program will check to be sure the same relay is not used
more than once. If a relay is assigned to more than one function, an error
message will be displayed.
error message: ————————-Alarm Relay conflicts with Ext Doser Relay Changed to
Ex_R1 ————————– or Changed to Ex_R2 or Changed to N/A
INTELLICHEM® Controller Installation and User’s Guide
25
Auto Setup Sequence Auto Setup See page 6 for details.
SAT Index Overview
Saturation Index
The Saturation Index (SI), also called the Langelier Index, is a chemical
equation or formula used to diagnose the water balance in the pool. The
Saturation Index formula is SI = pH + TF + CF + AF – 12.1 (or 12.2 for salt
pools). To calculate the Saturation Index, you must first test the pool water
for pH, temperature, calcium hardness, and total alkalinity. Refer to a chart
for assigned values for your temperature, hardness, and alkalinity readings
then add these to your pH value. Subtract 12.1 (or 12.2 for salt pools), which
is the constant value assigned to Total Dissolved Solids and a resultant
number will be produced. A result between +/-0.3 indicates balanced water.
Test results not within these values require chemical adjustments to achieve
balance. This formula is more or less reliable but not guaranteed. In some
cases, individual readings for pH, calcium, and Total-Alkalinity might be
beyond normal recommendations, however, combined within the formula can
produce “balanced water.” The SI is useful to pinpoint potential water balance
problems.
To access the Sat Index menu: Press MENU / Saturatn Index Press / and /to adjust the Saturation Index values.
pH Menu ORP Menu Saturatn Index Configuration
pH: 6.0 77F CH: 250 TA: 90
Temp:
SLT1000 CYA:18
Sat Index Menu
Note: The pH, Temp, and SLT are entered automatically as the numbers are
available from the measurement and automation system. Each time this display
is entered, if available, the current temperature is obtained from the
INTELLITOUCH®, EASYTOUCH® Control System), SLT is obtained from the
INTELLICHLOR® Salt Chlorine Generator (SCG). But these values can be changed
on this screen for calculation purposes.
pH: Enter the current pH value. Temperature: Enter the current temperature
setting. CH: Enter the current calcium hardness level. SLT: Enter the current
salt level or Total Dissolved Solids (TDS) level if no SCG is used. TA: Enter
the current total alkalinity value. CYA: Enter the current cyanuric acid
value. SI: Displays the last calculated SI value (Corrosive/Scaling/Ideal).
Note: If there is no flow or Flow Delay is enabled, no SI value displayed.
pH: 6.0 77F CH: 250 TA: 90
Temp:
SLT1000 CYA:18
pH: 6.0 77F CH: 250 TA: 90
Temp:
SLT1000 CYA:18
INTELLICHEM® Controller Installation and User’s Guide
26
Sat Index Overview (Continued)
Recommended Pool Chemistry
pH range:
7.2 to 7.6
ORP range:
650 to 750
Alkanlinity:
80 to 120 ppm
Calcium Hardness:
200 – 500 ppm
Cyanuric Acid/Stablizer:
Less than 30 ppm
pH: Chlorine produced by the IntelliChlor SCG is close to Neutral pH. However,
other factors usually cause the pH of the pool water to rise. Therefore, the
pH in a pool chlorinated by IntelliChlor tends to stabilize at approximately
7.8. This is within APSP standards. If the pool pH rises above 7.8, have a
pool professional test to see if other factors such as high Calcium Hardness
or Total Alkalinity are the cause and then balance accordingly.
Temperature: The pool water temperature can affect the saturation index value.
IntelliChem gets the temperature from the EasyTouch, IntelliTouch and SunTouch
automation control system. The automation control system must have the POOL or
SPA pump running to report the proper temperature to IntelliChem, otherwise
IntelliChem will use its own menu’s temperature value. To change the
IntelliChem default temperature, select Temp and use the Up/Down arrow to
adjust the temperature.
pH Level Test: Test the pH level of your pool water with a reliable test method. If necessary, adjust according to your pool professional’s recommendations. APSP’s recommended ideal range for pH is 7.2 to 7.6. Note: Never use dry acid (sodium bisulfate) to adjust pH in arid geographic areas with excessive evaporation and minimal dilution of pool water with fresh water. A buildup of by-products can damage the IntelliChlor SCG
Calcium Hardness Recommended range for calcium hardness is 200-500 ppm. Calcium Hardness levels should be tested weekly. Calcium hardness is the calcium carbonate scale deposited on pool surfaces. The test for Calcium Hardness is a measure of how “hard” or “soft” the water is testing. “Hard” water can have high levels of calcium and magnesium. If these levels are too high the water becomes saturated and will leave calcium carbonate scale deposits (a “white-ish,” crystallized rough spot) on any surface inside the pool. If the levels are too low, the water becomes “soft” and will corrode surfaces inside the pool. Use TSP or Hydroquest 100 to lower Calcium Hardness levels that are too high or add water to the pool which has a lower calcium hardness content. Levels which are too low require the addition of calcium chloride.
Total Dissolved Solids (TDS): Adding salt to pool water will raise the TDS
level. While this does not adversely affect the pool water chemistry or
clarity, the pool water professional testing for TDS must be made aware salt
has been added to the IntelliChlor system. The individual performing the TDS
test may then subtract the salinity level to arrive at a TDS level that would
be compatible to a TDS reading for a non-salt water pool.
Note: If a salt chlorine generator is being used for your pool, the salt level
is the TDS level of the pool.
INTELLICHEM® Controller Installation and User’s Guide
27
Sat Index Overview (Continued)
Total Alkalinity APSP’s recommended ideal range for total alkalinity is 80 to
120 ppm for “gunite” and concrete pools and 125-170 ppm for painted, vinyl,
and fiberglass pools. Test levels weekly and adjust according to your pool
professional’s recommendations. Total Alkalinity can be described as a buffer
that keeps pH in order. pH depends on the ability of the total alkalinity in
the water to withstand the changes in pH. If the total alkalinity is too high,
adding acid (similar to pH) lowers the level. Adding a base (e.g sodium
bicarbonate) when total alkalinity is low, raises the level. The level of
total alkalinity in the water is a measurement of all carbonates,
bicarbonates, hydroxides, and other alkaline substances found in the pool
water.
Cyanuric Acid: Cyanuric acid is needed in outdoor pools to help to stabilize
and maintain proper levels of chlorine. 90% of unstabilized chlorine is
destroyed by the UV radiation from the sun. Cyanuric acid stabilizes chlorine
in water from UV degradation. When using the IntelliChlor SCG, the cyanuric
acid level should be maintained at less than 30 ppm.
Optimum Pool Water Chemistry Conditions for Salt Water Pools (using the
IntelliChlor® Salt Chlorine Generator (SCG)
In accordance with the Association of Pool and Spa Professionals (APSP)
standards, it is recommended that the pool water chemistry conditions (see
page 21) be maintained on an on going basis to help protect pool users, pool
related equipment and surfaces in and around the pool. These values are
important to maintaining the pool equipment in proper operating condition and
preventing corrosion, liming or other problems. The IntelliChlor (SCG) is
warranted to operate properly only if these conditions are met. For more
information, refer to your local agency having jurisdiction, NSPI (National
Spa and Pool Institute), the CDC (Centers for Disease Control), or the WHO
(World Health Organization). Recommended pool water chemistry is given below:
Free Chlorine: 2.0 – 4.0 ppm. Above 4.0 ppm may cause corrosion of metal
components Combined Chlorine (Chloramines): None (super chlorinate to remove
all chloramines) pH: 7.2 – 7.8 (USE MURIATIC ACID to lower pH and Soda Ash to
raise pH.) Cyanuric Acid: Less than 30 ppm Total Alkalinity: 80 – 120 ppm
Calcium Hardness: 200 – 400 ppm TDS (includes salt): 3000 minium to 5700 to
6000 maximum ppm Salt: 3000 – 4500 ppm (ideal 3400 ppm) Metals (Copper, Iron,
Manganese): None Nitrates: None – Phosphates: Less than 125 ppb
Using the Langelier Saturation Index (LSI) to Diagnose Water Balance
Use the Langelier Saturation Index (LSI) calculator to diagnose the water
balance in your pool. Water with a LSI of 1.0 is one unit above a balanced
condition. Reducing the factors by 1 unit will bring the water into
equilibrium. To use the LSI calculator, refer to:
http://www.pentairpool.com/support/calculators/langelier/index.htm
INTELLICHEM® Controller Installation and User’s Guide
28
Sat Index Overview (Continued)
Calculating the Saturation Index
The saturation index is a formula that relates pH, calcium and alkalinity in
the pool water. A well balanced pool water will have a formula result range
between -0.5 and 0.5 Outside this range, the pool water is out of balance,
potentially damaging pool equipment or scaling the salt chlorine generator.
The equation to calculate Si is:
SI = pH + CHF + AF + TF – TDSF
Saturation pH as Index tested
Calcium
Alkalinity
Hardness Factor Factor
Temperature TDS Factor
Factor
(12.1 non-salt,
12.2 salt pools)
Cyanuric acid in the form of cyanurate ions contribute to alkalinity. Thus, a correction must be made to total alkalinity. We subtract 1/3 of the cyanuric acid level from the reading obtained in the total alkalinity test.
Total Alkalinity – 1/3 Cyanuric Acid = Corrected Alkalinity
This correction can be considerable in established pools with high cyanuric acid levels; for example, at 240 ppm cyanuric acid, the correction amounts to 80 ppm (240 ÷ 3 = 80).
Saturation Index Tables (as recommended by NSPF)
INTELLICHEM® Controller Installation and User’s Guide
29
INSTALLATION
(INTELLICHEM® CONTROLLER AND FLOW CELL)
Installing the IntelliChem® Controller
Before installing the IntelliChem controller, read the following instructions.
- IMPORTANT! If the equipment pad is below the water level of the pool,
please install a CHECK VALVE after the heater or use a Hartford Loop. 2.
Identify new and existing equipment to be connected. 3. Decide if the sensors
will be in a separate bypass line, or if the Flow cell will be used. Caution:
If the Flow Cell is being installed, the input water maximum pressure is 25
PSI. 4. Determine the supply voltage, and wire the transformer wires as needed
(see page 31). 5. Determine if the control to the equipment uses the same
voltage as the supply voltage. All controlled equipment must be compatible. 6.
Determine the water-tap points for the flow cell bypass inlet and outlet. 7.
Install the Flow Cell away from direct sunlight and on a flat vertical
surface. 8. Switch the main house circuit breaker OFF. Connect the supply
voltage to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/
power center (see page 40 for the IntelliChem controller AC power wiring
diagram). This ensures that the IntelliChem controller will only dispense
chemicals when the filter pump is ON. Note: The IntelliChem controller must be
connected to a separate dedicated circuit GFCI. 9. If using a Flow Cell
install the bypass now. 10. Connect the pH and ORP sensors. 11. Test the
plumbing for leaks. 12. Switch on the IntelliChem controller for the first
time as described below.
Risk of Electrical Shock or Electrocution! IntelliChem controller must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the current National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property.
Always disconnect the power to the IntelliChem controller enclosure at the circuit breaker before servicing the unit. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
INTELLICHEM® Controller Installation and User’s Guide
30
Mounting IntelliChem® Controller Enclosure
Mount the IntelliChem controller enclosure as follows:
1. Select a location for mounting the IntelliChem® Controller enclosure with
the following required recommendations:
2. Install the IntelliChem controller enclosure at least 10 feet from the
pool or spa wall.
3. Supply power must be routed to the IntelliChem controller in accordance
with the applicable national and current local (NEC) codes (see page i).
4. The installation surface must be solid and vertical. Do not mount the
IntelliChem controller enclosure in a horizontal position.
5. Maintain adequate clearance for opening the enclosure. 6. The environment
should be free of chemical fumes and excessive heat.
The maximum temperature it should not exceed is 110 ºF (50 C). 7. Mount as far
as possible from sources of electrical interference. 8. Mount the enclosure on
a flat surface. 9. Hold the enclosure against the mounting surface with a
closed lid and
mark the location of the mounting brackets located on the sides of the
enclosure next to the wall. Prepare holes as necessary and secure enclosure
using the provided mounting screws. 10. Install a conduit into the controller
enclosure.
Locate the chemical feed pumps and the chemical storage tanks in a safe and
secure area. Never turn the chemical feed pumps on when both flow cell valves
are closed. Increased pressure may cause the feed lines to blow off and spray
full strength chemicals on anyone or anything near the equipment. Securely
fasten all electrical, water, and chemical lines.
MOUNTING HOLES
Menu
Alarm Select
INTELLICHEM® WATER CHEMISTRY
MOUNTING HOLES
INTELLICHEM® Controller Installation and User’s Guide
31 Wiring the IntelliChem® Controller Transformer
D A N G E R ! RISK OF ELECTRICAL SHOCK OR ELECTROCUTION Always disconnect AC
power to IntelliChem controller at the circuit breaker before servicing.
Failure to do so could result in death or serious injury to installer,
serviceman, pool users, or others due to electrical shock. HIGH VOLTAGE WIRING
The high voltage wiring compartment is located inside the IntelliChem
controller enclosure. The IntelliChem controller can be connected either to
120VAC or 220-240 VAC. The IntelliChem controller should be wired to receive
power from the filter pump relay. Connect the AC power supply voltage to the
PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see
page 40 for the IntelliChem controller AC power wiring diagram). There is no
ground/bonding terminal required at this non-metallic enclosure. Follow
manufactures instructions when installing and testing of ground fault circuit
breakers (GFCB) and interrupters (GFCI). Connect input AC wires to the
IntelliChem controller transformer wires as follows: · 120 VAC: Connect one
wire to the Brown/Black wires connected together and one wire to the
Blue/White wires connected together. · 220 – 240 VAC: Connect one wire to
White wire and one wire to Brown wire. The Black/Blue wires are connected
together.
IntelliChem® Controller (Transformer Wiring) INTELLICHEM® Controller
Installation and User’s Guide
32
Connecting External Devices to IntelliChem Controller
External Devices such as pumps, CO2 devices and alarms can be connected to
either of the dry contact relays (EX_RELAY 1 and EX_RELAY 2). Relay contact
ratings: 5 AMPS, 250VAC/30VDC located on the IntelliChem® Controller circuit
board. See wiring diagram below and “Plumbing the Flow Cell” on page 35.
BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING THE INTELLICHEM®
CONTROLLER. AC Power may be supplied to the relay terminals Ex_Relay1 and
Ex_Relay2 from other sources. Wiring external devices must be performed by a
licensed certified electrician or a qualified pool professional in accordance
with the current National Electrical Code (NEC), NFPA 70 or the Canadian
Electrical Code (CEC), CSA C22.1. All applicable local installation codes and
ordinances must also be adhered to. Improper installation will create an
electrical hazard which could result in death or serious injury to pool users,
installers or others due to electrical shock, and may also cause damage to
property.
External Devices: EX_RELAY 1 and EX_RELAY 2, contact ratings: 5 AMPS, 250
VAC/30 VDC
External Device Wiring Diagram
INTELLICHEM® Controller Installation and User’s Guide
33 Installing the Flow Cell and pH/ORP Sensors
pH and ORP sensors are shipped with a protective cap covering the electrode
tip of the probes to protect the sensing element. DO NOT MIX THESE CAPS –
Solutions will destroy the other type of probe. Sensors should be kept in the
protective cap until ready for installation, if the sponge in the boot becomes
dry, wet it with pool water. Before using the sensor remove the cap. Mounting
the Flow Cell Remove Flow Cell from shipping carton and select a suitable
location for the flow cell within two (2) feet of the IntelliChem® Controller.
Note: The 3/8″ flexible tubing that is required to connect the flow cell to
the rest of the system is included with IntelliChem controller kit.
Mounting holes
Installing the pH and ORP Sensors (Read This First) Install the pH and ORP
sensors as follows: For IntelliChem® Controller Plumbing Installation Diagram,
see page 37.
1. Sensors wires will connect to within 10 feet. 2. Water leaks will cause
damage! Mount where water does not leak and
damage other components. 3. Mount flow cell vertically with provided screws.
4. Securely fasten all electrical, water and chemical lines. 5. Locate
chemical feed pumps and chemical storage tanks in a safe and
secure area. 6. Maximum operating pressure = 25 psi. 7. Extreme pressure
variances may affect readings and can cause damage
to the sensors. 8. Avoid installing the outlet before the main pump as the
vacuum may
damage the chemical sensors. Note: Do not over tighten fittings on flow cell
top.
INTELLICHEM® Controller Installation and User’s Guide
34
Installing the pH and ORP Sensors
To install the Flow Cell pH and ORP sensors:
1. Keep pH and ORP sensors wet at all times, install the sensors into the
flow cell. Hand-tighten only and save caps for future use (DO NOT MIX THESE
CAPS), fill flow cell with water. The sensors have O-Rings and don’t require
threaded sealing tape. · Do not rub hard on the glass element in the sensor or
use sand paper or other polishing material to clean.
· Handle electrode carefully.
· Sensors contain external and internal glass elements.
· Do not drop or otherwise subject the sensor to vibration, physical impact.
To avoid permenant damage of sensors or flow cell, do not use during freezing
conditions.
· Leave excess wire outside the controller enclosure. If the cable is longer
than needed, it should be coiled neatly and attached under the controller
enclosure.
· DO NOT CUT THE SENSOR WIRES. Do not stuff excess wire inside the controller
as this may cause excess strain on sensor and relay connections.
pH Sensor
ORP Sensor
INTELLICHEM® Controller Installation and User’s Guide
35
Plumbing the Flow Cell
Be sure to have a licensed plumber perform all plumbing; this is important, as
they will be familiar with all of the codes in the local area.
To connect the Flow Cell to the system plumbing: See page 37 for plumbing
diagram.
1. At the equipment pad, switch off the filter pump and release the pressure
from the system by opening the valve on top of the filter.
WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main
circuit breakers at the house before drilling into any pipes. Securely fasten
all electrical, water and chemical lines. Locate chemical feed pumps and
chemical storage tanks in a safe and secure area.
2. Close all valves to prevent flooding. 3. Attach the IN and OUT tubes to
the Flow Cell Inlet and Outlet
(see Tubing Installation Diagram shown below). 4. Run the end of the IN tube
to the chosen pressure line. Choose a location
that provides enough space to drill and to tighten the clamp (must be after
the filter, but before the heater). Be sure the tube is not pinched or kinked.
Mark a spot on the pipe. 5. Locate where the water will be supplied from and
returned for each flow cell. The most common location for the water inlet to
the flow cell is AFTER the main filter and BEFORE the heater. See page 37. 6.
Drill a 3/8″ hole for the flexible tubing fitting on the mark and immediately
place the fitting into the pipe. Align pipe clamp with the fitting and tighten
the pipe clamp. 7. Run the end of the OUT tube (with the pipe clamp) to the
chosen return line. Choose a location that provides enough space to drill and
to tighten the clamp (must be after the heater – see page 37). Be sure the
tube is not pinched or kinked. Mark a spot on the return line pipe. 8. Drill a
3/8″ hole for the flexible tubing fitting on the mark and immediately place
the fitting into the pipe. Align pipe clamp with the fitting and tighten the
pipe clamp. 9. Open any closed system valves. Close the filter valve and turn
on the circulation system. Check that the system is working properly.
Tu b i n g
Pipe Clam p
3/ 8″ Drill
Pipe
IntelliChem® Controller Tubing Installation Diagram INTELLICHEM® Controller
Installation and User’s Guide
36
Plumbing the Flow Cell (Continued)
Do not inject acid directly in to the flow cell. Injecting acid in this way
will result in incorrect reading which may damage the existing pool equipment.
10. Locate the chemical injection points. 11. Prepare and install the chemical
injector fittings. 12. Install the chemical storage containers. 13. Turn ON
the main circulation pump. 14. Check for leaks and verify the flow sensor
indicates flow.
Flow Cell Inlet and Exit Lines 1. It is essential that the supply line be at a
higher pressure than the discharge line so the water will flow through the
cell at a steady rate in the right direction. 2. Inlet should be installed
after filter and before heater. Note: Plumb the INLET before the solar valve.
3. Exit should be installed after heater and as far away from any equipment as
possible. Make sure all pumps are OFF before drilling into pipes. Never switch
ON chemical feed pumps without the pool filter pump also running. The flow
switch is a dry contact only (no current). Use with any other brand of flow
switch voids WARRANTY and UL listing.
INTELLICHEM® Controller Installation and User’s Guide
37
IntelliChem® Controller Installation Plumbing Diagram
INTELLICHEM® Controller Installation and User’s Guide
Fitting Tubing
IntelliChem® Controller
Acid Injection pump
INTELLICHE® M WTAER CHEYMISTR
Chlorine Pump
External pumps option:
1 pump (acid feed)
2 pump
(acid/chlorine feed)
Acid Chlorine
Pump
Pump
Outlet
Low Flow Switch Filter
Inlet
IN OUT
FILTER
HEATER
ACID
CHLORINE
P/N 521895(see page 32)
HAND TIGHTEN FITTINGS ONLY: USING A WRENCH TO TIGHTEN WILL CRACK FITTINGS
Figure 2: IntelliChem® Controller Plumbing Installation
CO2 Tank
CO2 Kit P/N714000070
Water Flow
38 Connecting the Sensors Wires to IntelliChem® Controller Circuit Board
The Flow Switch is a Dry Contact Only (No Current). This Flow Switch should
only be used with the IntelliChem® Controller. Use of this Flow Switch with
any other brand of controller will void the warranty and UL listing. 1. Route
the Flow Cell switch wires into the IntelliChem controller enclosure through
the strain relief and connect the wires to J6 Sensor terminal connector on the
IntelliChem controller circuit board. Connect the BLACK wire to the GND screw
terminal and the RED wire to the FLOW screw terminal. 2. Route the pH and ORP
sensor wires into the IntelliChem controller enclosure through the strain
relief and connect to J6 Sensor terminal connector on the IntelliChem
controller circuit board. The sensor wires are labeled. PLUS AND MINUS
POLARITY MUST BE OBSERVED. pH sensor wire: Connect the GREEN to the pH – screw
terminal and the CLEAR wire to the pH + screw terminal. ORP sensor wire:
Connect the GREEN to the ORP – screw terminal and the CLEAR wire to the ORP +
screw terminal.
Figure 2: IntelliChem® Controller J6/J7 Circuit Board Wiring 3. Turn the main
pump on and open the valves to test for leaks.
Make sure that all pumps are off before drilling into any pipe.
Never turn chemical feed pumps on when either flow cell valve is closed.
INTELLICHEM® Controller Installation and User’s Guide
39
CONNECTING TO AN AUTOMATION CONTROL SYSTEM
Wiring IntelliChem® Controller AC Power to Filter Pump Relay
IntelliChem AC Power Wiring Instructions: When using IntelliChem as a stand
alone device (with a time clock) or with an IntelliChlor salt chlorine
generator, IntelliChem MUST BE CONNECTED TO THE LOAD SIDE OF THE FILTER PUMP
RELAY located in the load/power center (see page 40 for IntelliChem AC power
wiring diagram). This ensures that IntelliChem will only dispense chemicals
when the filter pump is ON. For IntelliCenterTM, IntelliTouch®, EasyTouch® or
SunTouch® control system using an IntelliFlo® pump (or 2-speed pump) and an
IntelliChlor® (SCG), the IntelliChlor controller AC power center wires must
also be connected to the LOAD SIDE OF THE MAIN FILTER PUMP RELAY located in
the load/power center (see page 40 for diagram). This ensures that IntelliChem
controller and IntelliChlor SCG only produce chlorine when the main filter
pump is on. The following wiring diagram (see next page) shows the IntelliChem
controller AC power wiring and COM port connections to the IntelliCenter,
EasyTouch, IntelliTouch and SunTouch control system.
INTELLICHEM® Controller Installation and User’s Guide
40 IntelliChem® Controller AC Power and COM port (RS-485) Wiring Diagram
Note: For more information about operating automation pool controllers, refer
to the following manuals: – IntelliTouch® Control System User’s Guide
(P/N 521075) – EasyTouch® Control System User’s Guide
(P/N 521044) INTELLICHEM® Controller Installation and User’s Guide
41
Wiring the IntelliChem Controller AC Power to Automation Filter Pump Relay
PLease read the following information before starting!
IntelliChem controller AC Power Wiring Instructions: When using the
IntelliChem controller as a stand alone device (with a time clock) or with an
IntelliChlor salt chlorine generator, IntelliChem controller MUST BE CONNECTED
TO THE LOAD SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power
center (see page 40 for the IntelliChem controller AC power wiring diagram).
This ensures that the IntelliChem controller will only dispense chemicals when
the filter pump is ON. Note: For IntelliTouch®, EasyTouch® or SunTouch®
control system using an IntelliFlo® Pump (or 2-speed pump) and an IntelliChlor
(SCG), the IntelliChlor controller AC power center wires must also be
connected to the LOAD SIDE OF THE MAIN FILTER PUMP RELAY located in the
load/power center (see page 40 for diagram). This ensures that the IntelliChem
controller and IntelliChlor SCG only produce chlorine when the main filter
pump is on.
To connect IntelliChem controller AC power wires to EasyTouch, IntelliTouch
and SunTouch control system filter pump relay (see diagram on previous page).
D A N G E R ! RISK OF ELECTRICAL SHOCK OR ELECTROCUTION Always disconnect AC
power to EasyTouch, IntelliTouch and SunTouch control system load/power center
at the circuit breaker before servicing, or removing the HIGH VOLTAGE FRONT
PANEL. Failure to do so could result in death or serious injury to
1. IntelliChem Controller AC power: Run the IntelliChem controller AC power
wires to the EasyTouch, IntelliTouch or SunTouch control system enclosure.
2. EasyTouch or IntelliTouch Control System Load Center: Unlatch the
enclosure door spring latch, and open the door.
3. Discharge Electrostatic energy before removing the cover by first touching
the metal part of the enclosure.
4. Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT PANEL.
Remove the panel from the enclosure.
5. Connect the IntelliChem controller AC power cord wires to the LOAD/ PUMP
SIDE of the main filter pump relay (see wiring diagram on page 40).
6. When the connection is completed: EasyTouch and IntelliTouch Control
System: Close the control panel and secure it with the two (2) retaining
screws. SunTouch Control System: Close the front control panel and secure with
the retaining screw.
INTELLICHEM® Controller Installation and User’s Guide
42
Retaining screws
High Voltage Front Panel
Route IntelliChem® Controller AC power into opening under enclosure
CONNECT INTELLICHEM CONTROLLER AC POWER TO FILTER PUMP RELAY
CONNECT INTELLICHEM CONTROLLER AC POWER TO FILTER PUMP RELAY
Load Center (with SCG option)
Power Center (with SCG option)
IntelliChlor® Salt Chlorine Generator(SCG) Transformer
INTELLICHEM® Controller Installation and User’s Guide
43
Connecting IntelliChem® Controller RS-485 Communication Cable to the Control
System Circuit Board
To connect the IntelliChem controller COM Port Cable to EasyTouch®,
IntelliTouch® and SunTouch® Control System COM port (see page 40):
1. IntelliChem controller RS-485 cable: Strip back the cable conductors ¼ in.
Insert the wires into the connector screw terminals. Make sure to match the
color coding of the wires; YELLOW = +DATA, GREEN = -DATA and BLACK = GND. (Red
wire is not connected). Secure the wires with the screws.
2. Run an RS-485 cable from the IntelliChem controller enclosure to the
EasyTouch, IntelliTouch or SunTouch control systems enclosure.
3. Unlatch the load center/power center enclosure door spring latch, and open
the door.
4. WARNING! Switch AC power OFF to load/power center before installation (see
note on page 41) EasyTouch or IntelliTouch control system load center: Loosen
the two (2) retaining screws from the control panel. (a) Lower down the
control panel on its hinges to access the motherboard located behind the
control panel. (b) Route the IntelliChem controller RS-485 cable up through
the low voltage raceway in the load center to the motherboard. SunTouch
Control System Power Center: Route the conductor cable up through the lower
grommet opening into the enclosure.
5. Strip back the IntelliChem controller cable conductors ¼ in. Insert the
wires into the COM port connector screw terminals on the circuit board:
(EasyTouch J20, IntelliTouch J7/8, SunTouch J11). Make sure to match the color
coding of the wires; YELLOW = +DATA, GREEN = -DATA and BLACK = GND. (Red wire
is not connected). Secure the wires with the screws.
6. When the connection is completed: EasyTouch and IntelliTouch Contol
System: Close the control panel and secure it with the two (2) retaining
screws. SunTouch Control System: Close the front control panel and secure with
the retaining screw.
Setting Up EasyTouch, IntelliTouch & SunTouch Control System
IntelliTouch Control System The following describes how to setup the
IntelliChem controller from the IntelliTouch control system control panel.
From the IntelliTouch control system control panel you can adjust the pH and
ORP set point values, view the IntelliChem controller status and monitor your
pool water condition using the Saturation Index. To access the IntelliChem
controller the screens, from the IntelliTouch control system indoor control
panel or the wireless MobileTouch® Controller control panel:
Getting There
MENU SETUP EQUIPMENT INTELLICHEM
PH/ORP Values: The pH and ORP values are displayed next to the set point
settings. pH Set: Displays the current pH set point value. The adjustable
range is from 7.2 to 7.6 in increments of 0.1. The default pH set point value
is 7.5. To adjust the pH set point, press the button next to pH Set.
INTELLICHEM® Controller Installation and User’s Guide
44
ORP Set: Displays the current ORP set point value. The adjustable range is
from 650 to 800 in increments of 10. The default ORP set point value is 700.
The ORP set point is the value that IntelliChem will try to achieve based on
the active sanitizer. To adjust the ORP set point, press the button next to
ORP Set. STATUS: Displays the current communication link between IntelliTouch
and IntelliChem via the RS485 cable. IChem Comm Error: Check the RS-485
communication cable is connected to the COM port on the IntelliTouch
Personality circuit board. USING SCG: “USING SCG” displays if the IntelliChlor
salt chlorine generator is enabled. The SCG is enabled and disabled from the
MENU > SETUP > EQUIPMENT > CHLORINATOR screen. Note: IntelliChem must also be
set up to use the IntelliChlor SCG either with the AUTO SETUP Setup Wizard
(page 6) or the Configuration/ Hardware/ORP Control/Doser Type (page 24).
DISABLE/ENABLE INTELLICHEM: To disable IntelliChem, press the button under
DISABLE ICHEM. To enable IntelliChem, press the button next to INTELLICHEM. On
the next screen press button next to NO and select YES. Press SAVE to save the
setting and return to the Equipment screen.
Saturation Index/Menu: To access the Saturation Index screen, press the button
next to SATURATION INDEX/MENU. The current Saturation Index value, water
condition, water temperature and salt level are displayed. Press the button
next the following selections to adjust the levels/values: Calcium Hardness:
Recommended range is 200-400 ppm. Levels should be tested weekly. Cyanuric
Acid: Stabilizes chlorine in water from UV degradation. When using the
IntelliChlor SCG, cyanuric acid level should be maintained between 30-50 ppm.
Total Alkalinity: APSP’s recommended ideal range for is 80 to 120 ppm for
“gunite” and concrete pools and 125-170 ppm for painted, vinyl, and fiberglass
pools. Test levels weekly and adjust according to your pool professional’s
recommendations. Saturation Index: The saturation Index displays IDEAL
(Optimum levels), CORROSIVE or SCALING. The following are recommended pool
chemistry Saturation Index levels: pH range: 7.2 to 7.6 ORP range: 650 to 800.
Alkanlinity: 80 to 120 ppm. Calcium Hardness: 200 – 500 ppm. Cyanuric
Acid/Stabilizer: Less than 30 ppm.
Note: See page 28 for information the online Langelier Saturation Index (LSI)
Calculator to diagnose the water balance in your pool.
INTELLICHEM® Controller Installation and User’s Guide
45
Setting Up IntelliChem® Controller with EasyTouch Control System
EasyTouch® Control System
The following describes how to setup the IntelliChem® Controller from the
EasyTouch Control Systems control panel. From the EasyTouch control system
control panel you can adjust the pH and ORP set point values, view the
IntelliChem controller status and monitor your pool water condition using the
Saturation Index. To access the IntelliChem screens, from the EasyTouch Indoor
Control Panel or the EasyTouch wireless control panel: Press MENU > SETTINGS >
INTELLICHEM
Clock
IntelliFlo
IntelliChlor
IntelliChem
IntelliChem PH/ORP Values
Status Sat Index
pH pH ORP ORP
VAL 7.0 SET: 7.5 VAL: 650 SET: 750
IntelliChem PH/ORP Values Status Sat Index
pH Lvl: ORP Lvl: SCG IntelliChem: ON ORP Dosage Limit
IntelliChem PH/ORP Values Status Sat Index
pH: 7.5 TMP: 91 CH: 250 SLT: 4250 TA: 100 CYA: 30 SI= +0.04 IDEAL
PH/ORP Values: Press the Right button to access the pH and ORP set point values screen. The pH and ORP sensor reading VALues are shown only if adequate flow is sensed by the flow switch and the delay has been satisfied. otherwise displays NA (not available) Use the Up/Down button to adjust the pH set point value. Press the Right button again to set the ORP set point value. Press MENU to save and return to the previous screen. pH Set Point: Displays the current pH set point value. The adjustable range is from 7.2 to 7.6 in increments of 0.1. The default pH set point value is 7.5. ORP Set Point: Displays the current ORP set point value. Use the Up/Down button to adjust the ORP set point value. The adjustable range is from 650 to 800 in increments of 10. The default ORP set point value is 700 The ORP set point is the value that IntelliChem will try to achieve. STATUS: Displays the current communication link between EasyTouch and IntelliChem via the RS-485 cable. IChem Comm Error: Check the RS-485 cable is connected to the COM port on the EasyTouch circuit board. If “IntelliChem: –Disabled–” is displayed enabled IntelliChem from the automation system (see “Using SCG” on page 44). Other alarm messages are shown on page 48 Level Gauge indicator: Press the Up/Down button to “fill” the gauge icon so that it visually represents the same amount of acid available in the container. Press Up/Down button six (6) times to fill the gauge (three times to half fill the gauge). Six horizontal bars represent chlorine (or bromine) supply is full. One bar indicates the supply is nearly empty. Press MENU twice to exit and update the values.
Note: IntelliChem must also be set up to use the IntelliChlor SCG either with the AUTO SETUP Wizard (page 6) or the Configuration/Hardware/ORP Control/Doser Type (page 24).
Sat Index: To access the Sat Index settings, press the Up/Down button then press the Right button. Use the Up/Down button to adjust the levels/values for: CH (calcium hardness), SLT (Salt Content in water or Total Dissolved Solids if no salt is present), TA (total alkalinity), CYA (cyanuric acid) and TMP (current temperature). Note: See table below for ideal Saturation Index levels. SI: The saturation Index is displayed. IDEAL: Optimum levels. CORROSIVE or SCALING: Press the Menu button twicw to exit and update the values. Return to this menu for updated SI calculations. screen. Note: See page 28 for information the online Langelier Saturation Index (LSI) Calculator to diagnose the water balance in your pool.
INTELLICHEM® Controller Installation and User’s Guide
46
Setting up IntelliChem® Controller with SunTouch Control System
SunTouch Automation Control System
The following describes how to view the current IntelliChem pH and ORP levels
from the SunTouch control panel. To access the IntelliChem screens Press MENU
DIAGNOSTICS > INTELLICHEM
IntelliChem pH: 7.65 ORP:832
Displays the current pH and ORP levels. The IntelliChem controller is connected to the SunTouch control system via the RS-485 cable. The RS-485 communication cable
is connected to the COM port on the SunTouch® Control
System circuit board.
TROUBLESHOOTING
General Troubleshooting Guide (also see Help Guide on page 47) 1. Run Meter
Self-Test (see Configuration menu)
2. Run Probe-Open Test (see Configuration menu) 3. Clear pH and ORP Tweaks
(see Configuration menu) 4. Clean Sensors (see Maintenance section) 5. Check
chemicals and feed system 6. Take sample of pool water for analysis of CYA,
alkalinity, check saturation
index, Balance water 7. Replace Sensors 8. Repeat above steps
General Guidelines – pH or ORP not able to reach setpoint
This may be a common issue that can easily be resolved by increasing the
amount of chemical dispensed each day. If the pH Sensitivity is set to “Low”
(the default), IntelliChem will only administer the full dose at 0.5 from
setpoint. If it seems to be stuck 0.3 from setpoint, you’re only getting 3/5
of the programmed dose. Change the Sensitivity to “High” and you’ll get the
full dose at 0.2 pH or greater from setpoint. Or, turn pH Sensitivity OFF only
turn it on if you’re overshooting the setpoint. Increasing the dose would
essentially do the same thing. Increase the dosage as well as the dose-limit
and reduce the mix time so you still get all 8 doses in the filter run time.
Diagnostics Self Test and Error codes
The overall functionality of the IntelliChem can be verified by running the
self test. Access this feature in the Configuration/Diagnostic menu. The test
verify the LCD display, front panel LED indicators, push buttons, flow switch
input, doser motors, relays, the RS-485 communication, and the meter. Warning!
This test will turn on the doser, so be sure that the tubing is installed in a
safe manner so that the chemicals will be safely contained.
Error Codes (Self Test Status: Fail) 01H : LCD 02H : Backlight 04H : LEDs 08H
: Buttons 10H : Flow Switch 20H : Outputs 40H : Loopback 485
80H : Meter
INTELLICHEM® Controller Installation and User’s Guide
Help Guide
47
See page 52 -53
INTELLICHEM® Controller Installation and User’s Guide
48
Alarm Messages and Troubleshooting Tips
The IntelliChem is continually monitoring its own condition and that of the
water chemistry. The following is a list of alarms and most likely causes.
This should give you a good starting place for troubleshooting and resolving
the alarm.
Troubleshooting the alarm messages
.
** Displayed in various places on the main screen
INTELLICHEM® Controller Installation and User’s Guide
49
Troubleshooting the alarm messages
Flashing pH/ORP tank/hourglass symbol ORP LOW
ORP HIGH pH LOW
pH HIGH
Check pH Tank Check ORP Tank
ORP Is Too Low ORP Reading Too Low
ORP Is To High ORP Reading Too High PH Is Too Low
pH Reading Too Low
PH Is Too High pH Reading Too High
Refill the chemical supply container and set the gauge to the appropriate
corresponding level. This alarm indicates level is low and should be refilled.
If non-fluid supply sources are used, like CO2 and SCG, you can set a reminder
in the pH/ORP Supplies 2/2 menu that will trigger this alarm as a reminder to
change CO2 canisters or clean the SCG plates. The reminder is reset either in
the Supplies 2/2 menu or the pH/ORP Settings button.
Increase filter time and increase dose size. This may be the result of the ORP
Sensitivity setting. If the sensitivity is set to “Low”, you may not have a
sufficiently sized dose to reach the setpoint. Try turning Sensitivity to
“High” or “Off”.
Check overall water chemistry using the Saturation Index calculator or have
water tested by a professional pool service person or dealer. Also, check that
the dose dispensing device is operating properly and that your supply tank is
full.
Overshooting ORP may simply be a result of Cyanuric acid in the pool which
suppresses the ORP during the sunlight hours and releases chlorine at night.
It may also be that dose size is set too high with insufficient mix time.
Turning ORP Sensitivity to “Low” may help reduce overshooting.
Overshooting pH may be due to the dose size being set too high with
insufficient mix time. Turning pH S ensitivity to “Low” may help reduce
overshooting. Test overall water chemistry using the Saturation Index
calculator. Low Total Alkalinity may contribute to rapid pH swings and make
controlling water nearly impossible. Consult your pool professional. Check
overall water chemistry using the Saturation Index calculator or have water
tested by a professional pool service person or dealer. Also, check that the
dose dispensing device is operating properly and that your supply tank is
full.
Increase filter time and increase dose size. This may be the result of the pH
Sensitivity setting. If the sensitivity is set to “Low”, you may not have a
sufficiently sized dose to reach the setpoint. Try turning Sensitivity to
“High” or “Off”.
NO FLOW DETECTED
No Flow
Check pump, flow cell, filter, and valves.
Ensure the pool pump is turned on, that valves are properly positioned, and
that sufficient water is being directed to the flow cell. Make sure the flow
switch is closed (shorted) which indicates flow.
Warning: This is a Safety Device. Do not operate the IntelliChem with the flow
switch bypassed. Water flow must be present to ensure chemicals are mixed
adequately to avoid dangerous gasses and high concentrations of chemicals near
people or pool equipment.
Awaiting FLOW DELAY
Flow Delay
pH has priority
PH Priority
This is not an alarm, only a message indicating that water chemistry control
will commence after this count-down timer expires. To allow pool water to
stabilize and time for chemicals to activate, a minimum of 15 minutes is
required to get accurate readings. The Flow Delay is set in the
Configuration/Delays menu. It is the combination of the Power- On and Flow-
Switch delay settings. As a convenience for the pool service person, you may
bypass the delay by holding the Up Arrow button for 3 seconds. Please give
time for the water to stabilize before expecting proper operation of the
equipment.
This is not an alarm but a message that pH is feeding (acid) and that ORP
(chlorine) is on hold until the acid feed is finished. This is enabled in the
Configuration/Dose Priority menu on systems where the acid and chlorine may be
injecting near the same point in the plumbing and the installer has decided,
for safety reasons, to only feed one chemical at a time.
** Displayed in various places on the main screen
INTELLICHEM® Controller Installation and User’s Guide
50
Cross Reference
INTELLICHEM® Controller Installation and User’s Guide
** Displayed in various places on the main screen
51
Tweaking pH (Calibrating Sensor)
Measure the pH using a standard test kit by taking several readings and
averaging the results. To Tweak the pH sensor see page 12.
Tweaking ORP (Calibrating Sensor)
Always make sure the pH is at the set point before calibrating ORP. Always
control at PPM levels greater than 1.0 PPM when using ORP sensors.
IMPORTANT: For best results the ORP should be at the ORP set point when
calibrating. For best results the PPM should be at the desired level when
calibrating ORP. To Tweak the ORP sensor see page 15.
IntelliChem Specifications
RATINGS:
Input Voltage:
120 VAC / 220-240 VAC 50/60 Hz
200 mA / 100 mA or 0.2 A / 0.1 A
Relay Rating:
Dry Contact 5 A, 120 VAC / 30 VDC
Temperature:Min./Max. Operating Temperature 30° – 110° F
Sensor Range:
pH 4.0 – 9.99 – ORP 0 – 999mV
Flow Open or Closed
MAINTENANCE
Winterizing: The Flow Cell sensors must be protected from freezing conditions.
If the pool is winterized, plan to remove and store the sensors (as described
above) as part of the normal pool winterizing process. The Flow Cell and
related plumbing must be drained as well.
Water Chemistry Always test water chemistry with a quality manual test kit.
Therefore, it may be preferable to calibrate pH using commercially available
reference solutions. If required, use the IntelliChem Tweak pH feature to
periodically adjust the pH reading (see above and page 12). It’s important to
note that changes in pH, cyanuric acid concentration, total dissolved solids,
and use of additional or alternative sanitizers will all affect the primary
sanitizer residual level relative to ORP. Maintain total alkalinity on regular
basis to ensure pH stability. To maintain a consistent sanitizer residual in
parts per million (ppm), periodically adjust the ORP level.
Sensor Maintenance: The Flow Cell sensors must be clean and free from oil,
chemical deposits and contamination to function properly. After saturation in
pool or spa water, the sensors may need to be cleaned on a weekly or monthly
basis depending on bather load and other pool specific characteristics. Slow
response, increased need to calibrate pH, and inconsistent readings are
indications that the probes are in need of cleaning.
INTELLICHEM® Controller Installation and User’s Guide
52
MAINTENANCE (Continued)
Cleaning the Flow Cell Sensors: To clean the ORP and pH sensors, turn off the
AC source power to IntelliChem at the GFCI switch. Disconnect the probe
connectors from the Flow Cell, unscrew the probe and carefully remove them
from the Flow Cell. Clean the reference junction (the white ring at the bottom
of the probe body) with a soft toothbrush. A household liquid dish washing
detergent may also be used to remove any oil. Rinse with fresh water and
reinstall probes. If properly cleaned probes continue to provide unstable
readings or require excessive calibration, the probes should be replaced.
Probe exposed to atmospheric conditions will cause the probe tips to dry out.
Store the sensors with the included plastic sensors storage caps if removed
from the Flow Cell for more than one hour. If the storage caps have been
misplaced, store the probes individually in small glass or plastic containers
with clean water covering the sensor tips. Store sensors in a location that
will not be subjected to freezing temperatures.
Sensor Care
Contamination of the sensing elements often results in slow response and
inaccurate readings. Clean the elements by the following procedures: pH and
ORP Sensors
1. Wash electrode tip in a liquid detergent and water. Carefully use a soft
bristled toothbrush to wash the electrode tip and white sensing ring.
2. Rinse after cleaning. To reinstall the flow cell (see page 33). Hand
tighten to sensors to secure in place.
3. Make sure the O-ring is installed on sensor. 4. If the cable is longer
than needed, it should be coiled neatly and attached
under the enclosure. pH Sensors Only
5. Attempt to clean the sensor with liquid detergent first. 6. If this is not
successful, swirl the tip of the sensor in a 5 parts water and 1
part muriatic acid solution for 10 – 20 seconds. 7. Rinse again and reinstall.
WARNING Do not rub hard the glass element in the sensor or use sand paper or
other polishing material to clean. HANDLE ELECTRODE CAREFULLY Sensors contain
external and internal glass elements. Do not drop or otherwise subject the
sensor to vibration, physical impact, or freezing conditions. ANY TYPE OF
BREAKAGE IS NOT COVERED UNDER WARRANTY.
pH and ORP Sensors: pH electrodes sense the acidity of the water and work with
any acid or base. The blue bands on the cables identify the pH sensors. The
red bands on the cables identify ORP sensors. Each sensor is also identified
on the sensor body. ORP electrodes are used to monitor the Oxidation Reduction
Potential (ORP is sanitization quality of the water) of a given solution. The
sensing element of the ORP electrode is made of a precious metal such as
platinum or gold. Sensors: IntelliChem measures the following sensor
measurements with the listed characteristics:
pH Range: 4.00 to 9.99 ORP Range: 0 to 999 mV Flow Switch: This input measures
if a switch is open or closed. Open is no water flow. A closed switch
indicates flow.
INTELLICHEM® Controller Installation and User’s Guide
53
Motor Pump Head Yearly Replacement
IMPORTANT! Replace the IntelliChem pump head (P/N 521384Z) once a season
(yearly).
Pump Head Replacement (for single or multiple pumps)
Disconnect AC power to IntelliChem® Controller enclosure at the circuit
breaker before servicing. Failure to do so could result in death or serious
injury to serviceman, pool users or others due to electrical shock.
1. STOP THE MAIN POOL FILTERPUMP. 2. First loosen the Jaco fitting on the
OUTLET tube. Carefully disconnect the
tube. Keep the tube pointed upward to keep the chemical from spilling out the
top of the tube. 3. Connect the tube to the OUTLET of the new pump head Jaco
fitting. Secure the tube. 4. Repeat Step 1 and 2 for the INLET tube. 5. Remove
the upper and lower screws securing the old pump head and remove the pump head
from the motor assembly. 6. Install the new pump head (with attached tubes) to
the motor assembly. Secure the pump head with the two screws.
Screws
Pump head with tube, Jaco fitting and screws (P/N 521348Z).
Output tube (Jaco fitting)
Inlet tube (Jaco fitting)
INTELLICHEM® Controller Installation and User’s Guide
54
IntelliChem® Controller Replacement Parts List
1. P/N 521465Z – Top Half (Lid with
overlay and wiring diagram).
2. P/N 521319Z – IntelliChem Controller
Circuit Board.
3. P/N 8520031Z – Circuit Breaker.
4. *P/N 521348Z – Pump head Jaco
fitting with tube and screws.
5. P/N 521466Z – Jaco fitting.
6. P/N 521467Z – Enclosure mounting
1
brackets.
7. P/N 521338Z – Pump motor.
8. P/N 521468Z – Strain relief kit.
9. P/N 521335Z – Replacement
transformer with mounting plate.
Note: (*) MUST REPLACE ONCE A SEASON (YEARLY).
2
3 9
4
7 6
8
5
Warranty Information The IntelliChem controller has a one year limited
warranty. For more information contact Customer Support
800-831-7133
INTELLICHEM® Controller Installation and User’s Guide
55
IntelliChem® Controller Flow Cell Replacement Parts List
1. P/N 522186 – Sensor, pH (* 1 year warranty)
2. P/N 522187 – Sensor, ORP (* 1 year warranty)
3. P/N 754000310 – Flow Cell with Flow Switch Sensors
4. P/N 521342Z – IntelliChem Controller Parts Bag (not shown)
5. P/N 523481 – Cap Plug
5a. P/N 522623Z – Low Flow Switch, 3 ft.
5b. P/N 522624Z – Low Flow Switch, 10 ft.
6. P/N 744000290 – Cable, pH 3 ft
7
7. P/N 744000360 – Cable, ORP 3 ft
8. P/N 754000340 – O-Ring for Flow Jar
9. P/N 754000350 – Flow Jar
6
Accessories:
P/N 521814
– 3/8″ Black Tubing (optional)
P/N 744000280 – Cable, pH 10 ft (optional)
1
P/N 744000350 – Cable, ORP 10 ft (optional)
2
23 3
5
5a 5b
WIRE FERRULE, 22-AWG,
TURQUOISE
8 5a Low Flow Switch, 3 ft.
or
5b Low Flow Switch, 10 ft.
9
- Warranty Information The IntelliChem Controller pH Sensor and ORP Sensor each have a one year limited warranty.
The IntelliChem Controller pump head, pH Sensor and ORP Sensor are considered wear items and are covered by their own warranty periods and are not part of any extended warranty coverage.
For more information contact Customer Support 800-831-7133
INTELLICHEM® Controller Installation and User’s Guide
56
IntelliChem® Controller Kit Contents
9 1
6 7
2
5 4
8 3
Item QTY. Part Number
1
1
522010Z
2
2
522347Z
3
1
606000100Z
4
1
620000040Z
5
3
622000080Z
6
2
R172032
7
2
R172033
8
1
R172036
9
1
62000130Z
Description FILTER INLINE STRAINER 1/4″ FEMALE NPT CLAMP SADDLE ICHEM BYPAS FTG 3/8″ COMPRESSION X 1/4″ NPT FTG 1/4″ NPT NYLON PLUG 1/4″ NPT M/F BALL VALVE TUBE FITTING WITH NUT GASKET,.75 OD LUBRICANT, SILICONE,3/4OZ .25 NPT 7/8 CLOSE NIPL SC H80
INTELLICHEM® Controller Installation and User’s Guide
57
Appendix A: 2016 IntelliChem Controller Configurations
Starting in 2016, there are now three IntelliChem Controller system
configurations that are intended to make the initial setup easier:
1. P/N 521357 Includes just the controller, flow cell, and probes. This
system is NSF approved.
2. P/N 522621 Includes the controller, flow cell, probes, and a 4 gallon
acid tank with a new Stenner 50 GPD pump mounted to it. The pump has a 15 foot
cable that plugs into a new dedicated spot on the IntelliChem motherboard for
easy setup.
3. P/N 522622 Includes the controller, flow cell, probes, and 4 gallon acid
and chlorine tanks with new Stenner 50 GPD pump mounted to them.
Older IntelliChem Controller systems can be upgraded to this new style with
the following part numbers:
· P/N 522474 Upgrades older non-pump containers (521378 & 521397) with the
new tank mounted Stenner pump.
· P/N 522478Z Upgrades older IntelliChem Controller motherboards to allow
use with new acid and chlorine tanks with tank mounted pump.
· P/N 522472 Acid tank with tank mounted pump.
· P/N 522473 Chlorine tank with tank mounted pump.
Please note that Pentair always recommends 1:1 dilution when using full
strength muriatic acid. When mixing, remember to always add acid to water.
The new Stenner pump uses the same programming as the 50 GPD wall mounted Stenner pump that was shipped with IntelliChem from 2012 to 2014. The 50 GPD tube in the new Stenner pump has a higher burst pressure rating (80psi) than the discontinued #5 Stenner tube (25psi).
New circuit board where tank mounted pumps plug in to (pH on left/ORP on right
side) of the IntelliChem controller circuit board.
INTELLICHEM® Controller Installation and User’s Guide
58
Installing the IntelliChem Tank with Pump (P/N 522472 & 522473)
1. Find a suitable location to secure the tank to the equipment pad. The tank
needs to be within 10′ of the IntelliChem Controller, 10′ of the return
plumbing, and away from equipment that may be damaged by the chemical or
vapor.
2. Secure the tank to the equipment pad with four bolts. 3. Cut off 1-2′ of
tubing and connect the black suction fitting of the tank to the
inlet (right) of the pump. See Figure 1. Do not overtighten the nuts. 4.
Install the injection fitting in the return plumbing, after all equipment. 5.
Use the remaining tubing to connect the outlet (left) of the pump to the
injection fitting. Note: Do not overtighten the nuts.
Upgrading a Chemical Container with Pump Kit, Using P/N 522474
1. Be sure the Chemical Container is secured to the equipment pad, and in a
suitable location within 10′ of the IntelliChem Controller.
2. Remove the four screws and block-off plate. 3. Install the motor shroud
with four screws. See Figure 1. 4. Mount the pump on the motor shroud with
four screws. See Figure 1. 5. Cut off 1-2′ of tubing and connect the black
suction fitting of the tank to the
inlet (right) of the pump. See Figure 1. Note: Do not overtighten the nuts. 6.
Install the injection fitting in the return plumbing, after all equipment. 7.
Use the remaining tubing to connect the outlet (left) of the pump to the
injection fitting. Note: Do not overtighten the nuts.
Discharge Suction
INTELLICHEM® Controller Installation and User’s Guide
59
Connecting the Pump to the IntelliChem Controller, Using P/N 522478Z
1. Route the power cord(s) from the Pump(s) into the IntelliChem Controller
through the strain relief fitting(s) closest to the right hinge. Note: Do not
overtighten the nuts.
2. Plug the power cord for the Acid pump into the left connector labeled “PH”
on the 522478 daughter board. See Figure 2.
3. (Optionally) plug the power cord for the Chlorine pump into the right
connector labeled “ORP” on the 522478 daughter board. See Figure 2.
4. Loosen the 4 screws in the J8/J11 terminal blocks on the IntelliChem
Controller board.
5. Install the 522478 daughter board so that all four pins are in the correct
holes in the J8/J11 terminal blocks. Tighten the four screws. See Figure 3.
6. Unplug the red wire harness going to J10 of the IntelliChem Controller
board, and connect it to J10 on the 522478 daughter board. See Figure 4.
7. Plug the wire harness from J10* of the 522478 daughter board to J10 of the
IntelliChem Controller board. See Figure 4.
Plug Acid Plug Chlorine Pump Here Pump Here
Figure 2. pH and ORP Connection
Figure 3. Wiring Terminal Blocks
Wiring harness from Daughter Board
Wiring harness from Transformer
Figure 4. Power Connection
INTELLICHEM® Controller Installation and User’s Guide
60
Auto Setup Sequence
Use the Auto Setup feature for first-time setup of standard configurations.
Follow the onscreen prompts and enter information about your system
configuration (pH/ORP internal or external pumps, pool size, filter time,
chemical container size etc). IntelliChem uses this information to
automatically setup reminder times, calculate feed times, proportional limits
and alarms. The following describes the Auto Setup screen. Press the MENU
button to access the Auto Setup menu. To change a menu setting or value press
the / Up/ Down arrow button. Press the MENU button to save each selection.
Press MENU / Auto Setup Previous Values: Use to recalculate new dose times
etc., if no custom settings exist. Not recommended for custom settings; use
the menu directly to make these changes. Reset All: Make major configuration
changes that may have conflicts with previous settings.
IntelliChem Auto Setup Wizard Press MENU to go to each new step
To exit Auto Setup, press
Dosing will resume when you exit this menu Press any button
Would you like to use previous