Specifications
- Rated Power: 700 W / 1,000 W / 1,250 W / 2,500 W
- Battery Voltage: 12 Vdc, 24 Vdc, or 48 Vdc
- AC Output Voltage (Vac): 120 Vac / 60 Hz, 127 Vac / 60 Hz, or 230 Vac / 50 Hz
- Communication Options: AC Interface Options – Remote Switch, USB, EIA-485 and 12 V / 1 W auxiliary power, MS-CAN, Bluetooth
DIP Switch Settings
DIP Switch | Setting | Description |
---|---|---|
DIP 1 | OFF | Switch Control |
DIP 1 | ON | Digital Control |
DIP 5 | OFF | LVD Preset: 10.5 V (for 12 Vdc), 21.0 V (for 24 Vdc), or 42.0 V |
(for 48 Vdc)
DIP 5| ON| LVD Preset: 11.5 V (for 12 Vdc), 23.0 V (for 24 Vdc), or 46.0 V
(for 48 Vdc)
DIP 2| OFF| Alarm is Disabled
DIP 2| ON| Alarm is Enabled
DIP 6| OFF| AC Output Always ON
DIP 6| ON| AC Output OFF < 8 W
DIP 7| OFF| Ethernet Write Disabled
DIP 7| ON| Ethernet Write Enabled
DIP 8| OFF| Bluetooth Disabled
DIP 8| ON| Bluetooth Enabled
LED Indications
Operation or State | STATUS LED1 | AC Output LED |
---|---|---|
No power or Battery below 9.5 V | OFF | OFF |
AC Output OFF | GREEN | GREEN |
AC Output ON | GREEN | RED |
AC Standby Mode | OFF | GREEN (BLINK) |
Low Voltage Disconnect (LVD) Warning | OFF | RED (BLINK) |
Low Voltage Disconnect (LVD) | RED | RED (BLINK) |
Recoverable Fault3 | RED | RED |
- Contact Information:
- Technical Support: morningstarcorp.com/support
- Phone: 1-215-321-4457
- Quick Start Guide:
- SureSine Inverter Models: 700 W / 1,000 W / 1,250 W / 2,500 W (for Models that require hardwiring)
- IMPORTANT:
- The SureSine Inverter is designed for converting DC power to AC power only. It will not charge batteries.
- WARNING: Hazardous Voltage
- The SureSine Inverter must be installed by a qualified technician in accordance with the electrical regulations of the country of installation.
- CAUTION:
- This guide must be used with the full product manual that includes important information. Carefully read the SureSine Inverter product manual for all specifications, safety, regulatory and warranty information, and for all required instructions on installation procedures, configuration, and operation.
FAQ:
-
Can the SureSine Inverter charge batteries?
No, the SureSine Inverter is designed for converting DC power to AC power only. It does not have battery charging capabilities. -
What are the available communication options for the SureSine Inverter?
The SureSine Inverter offers AC Interface Options including Remote Switch, USB, EIA-485 and 12 V / 1 W auxiliary power, MS-CAN, and Bluetooth. -
How do I set the Low Voltage Disconnect (LVD) on the SureSine Inverter?
The LVD can be set using DIP Switch 5. The OFF position corresponds to a preset value of 10.5 V (for 12 Vdc), 21.0 V (for 24 Vdc), or 42.0 V (for 48 Vdc). The ON position corresponds to a preset value of 11.5 V (for 12 Vdc), 23.0 V (for 24 Vdc), or 46.0 V (for 48 Vdc).
For use with 12 Vdc, 24 Vdc, or 48 Vdc Systems
- Scan QR Code to go directly to the SureSine Inverter Installation Manual and warranty information online.
- Warranty Registration: https://www.morningstarcorp.com/product-registration/
In the Box:
Tools Required
-
2 Philips Screwdriver
- 3/16 (5 mm) & 1/8″ (3.8 mm) Flathead
- Screwdriver
- Drill with a 1/8″ (3.8 mm) bit
- Multimeter
- Crimping Tool
- Wrench
Minimum Clearance Requirements:
-
WARNING: Risk of Fire
Do not install over an easily combustible surface, since the heat sink may get hot under certain operating conditions. -
CAUTION: Burn Hazard
Place in a location to avoid direct contact. -
WARNING: Explosion Hazard
Never install the SureSine in an enclosure with vented/flooded batteries. Battery fumes are flammable and will corrode and destroy the SureSine circuits. Ensure sufficient ventilation. -
CAUTION: Equipment Damage
Do not expose the SureSine to weather. Locate in a dry, protected area to prevent equipment damage.
Ensure the minimum clearance requirements are followed to provide adequate ventilation and prevent the unit from overheating.
Mounting
- Step 1: Choose mounting location
- Determine how and where the inverter will be mounted.
- Ensure the inverter is protected from sun, rain, and dust.
- Step 2: Wiring accessibility and air flow clearance
- Plan and confirm wire routing-access.
- Verify that the mounting screws will not penetrate wires or other objects located on the opposite side of the surface.
- Verify that there is at least 6″ of space around the unit.
- Step 3: Mark and drill holes
- Place the inverter on the wall where the unit will be mounted.
- With a pencil or pen, mark the center of each keyhole slot; two (2) on top and two (2) on the bottom.
- Remove the inverter and drill four (4) 1/8″ (3.175 mm) holes where the marks were made
- Step 4: Secure the inverter
- Place the SureSine onto the surface and align the keyhole slots with the four (4) pilot holes.
- Use the four (4) #10 screws (included) to secure the SureSine to the surface.
TERMINAL TORQUE REQUIREMENTS
Terminal| **Terminal Size or Wire Size*| Torque to:**
In-lbs.| Nm
DC (+) (–) Input Bolt Terminals| M6 (~1/4″)| 35| 4
AC Output Neutral, Line and Ground Terminals| M6 (~1/4″)| 20| 2.3
Chassis Ground Lug| 14 – 2 AWG (2.5 – 10.0 mm2)| 35| 4
Modbus, Remote Switch, Auxiliary Power Terminals| 16 – 28 AWG (1.0 – 0.1 mm2)|
5| 0.57
- For recommended/minimum wire sizes and disconnect/fuse sizes per application, and terminal block installation for the remote switch or communications options, see the SureSine Installation and Operations Manual.
IMPORTANT:
- Example only.
- Actual wiring may vary.
- READ the SureSine Installation and Operator Manual for mandatory safety requirements.
- All configurations must comply with local and national electric codes.
- Consult the local electric authority to ensure compliance.
IMPORTANT:
- Neutral-Ground Bond
- The AC Neutral of the 120 Vac/ 60 Hz models is bonded to the inverter frame internally from the factory as required for UL safety requirements.
- The AC Neutral of the 127 V, 230 V, and 240 V models is floating (not bonded to the inverter frame).
- If a neutral-ground bond is required an internal neutral-ground jumper wire (included) can be used to connect the neutral terminal to the grounded chassis.
- Ensure there is only 1 Neutral-to-Ground Bond in the entire system.
- Consult Section 2.8.4 of the manual for additional information.
Power UP Sequence:
- Connect Battery/Battery Bank. (STEP 11)
- Close all circuit breakers, disconnect switches, or insert fuse into fuse holder. (STEP 12)
- Put the AC Output Mode Switch in the ON (or REMOTE) position. (STEP 13)
Power DOWN Sequence:
- Put the AC Output Mode Switch in the OFF position.
- Open all circuit breakers, disconnect switches, remove fuses from fuse holders.
- Disconnect Battery/Battery Bank.
Specifications
Rated Power| 700 W / 1,000 W / 1,250 W / 2,500 W| Communication Options|
- Remote Switch, USB,
- EIA-485 and 12 V / 1 W auxiliary power, MS-CAN,
- Bluetooth
---|---|---|---
Battery Voltage| 12 Vdc, 24 Vdc, or 48 Vdc
AC Output Voltage (Vac) / Frequency|
- 120 Vac / 60 Hz, 127 Vac / 60 Hz,
- or 230 Vac / 50 Hz
| AC Interface Options| HW – Hardwire
- Partial Specification List only. For the complete list of specifications, see the SureSine Installation and Operation’s Manual.
DIP Switch Settings:
LED Indications:
- The Status LED flickers ON very briefly when the LED is OFF.
- The Status LED flickers OFF very briefly when the LED is GREEN or RED solid.
- The “heartbeat” occurs every 5 seconds.
AC Output Mode Switch
- 2 0.5 Hz. Rate
- 3 See the SureSine Inverter Installation and Operations Manual for details.
Contact Information:
- Technical Support:
- Phone:
© 2022 Morningstar Corporation. All Rights Reserved.
-
MS-003789 v1
-
IMPORTANT:
The SureSine Inverter is designed for converting DC power to AC power only. It will not charge batteries. -
WARNING: Hazardous Voltage
The SureSine Inverter must be installed by a qualified technician in accordance with the electrical regulations of the country of installation. -
CAUTION: This guide must be used with the full product manual that includes important information. Carefully read the SureSine Inverter product manual for all specifications, safety, regulatory and warranty information, and for all required instructions on installation procedures, configuration, and operation.
SureSine Inverter Models:
- 700 W* / 1,000 W /
- 1,250 W / 2,500 W
- for Models that require hardwiring.