Product specification parameters
Working voltage | 3.7V |
---|---|
Working current | 3A-8A |
Charging voltage / current | 5V/1.5A |
Maximum output | 5ow |
Noise test | 83dB distance of 100cm radial test) |
Test loop | 400 Vacation times |
Work environment | -20°C to +80°C |
Storage environment | -40°C to +80°C |
Conttnuous working time | LO\\I speed for 30 minutes, high speed 15 minutes |
Operation manual
- Fan button: long press to open the fan to enter the low speed state, then short press to switch high and low gear, long press to close the fan.
- Key light: 1 often bright, 2 slow flash, 3 flash, 4 off, cycle switch.
- LED :the red light flashes when the power is too low, the red light flashes when charging, and the red light is full
- Charging mode: Type-C charging port.
Instructions for transfer interface
Please select the appropriate transfer interface as required and fill the
transfer port to the air port of the air pump.
| For swimming pool, balloons, etc
---|---
| For swimming rings, inflatable toys, etc
| For air bed, etc
| For inflatable raft, etc
Debugging
f it does not work properly:
When the red light flashes, the power is low. Please charge in time.
Plug in the charger and check the battery for power.
Please check the pump surface for water or other liquid.
Check whether the fan blade is stuck or blocked by foreign objects.
Repeated attempts to switch the machine
* Matters need attention
- This product is intended only for domestic or personal use and is not intended for industrial use.
- Product protection program when charging, the product is in the protection state can not be used.
- This product is not a toy, is prohibited by minors and children.
- This product is not waterproof, do not contact with any liquid and water.
- This product contains lithium batteries, please stay away from the fire source and the temperature above 50 degrees Celsius.
- Do not use it continuously for more than eight minutes.
- Keep the air outlet and air inlet clean.
- Do not reach into the air outlet port and the air inlet port.
- Please check whether the air pump will function properly before each use.