beamZ Pro BTF200Z Fresnel LED 200W Zoom Warm Stage Spotlight User Manual

June 15, 2024
beamz Pro

beamZ Pro BTF200Z Fresnel LED 200W Zoom Warm Stage Spotlight

Product Information

  • Model: BTF200Z
  • Version: 151.378 V1.1

Specifications

  • Operating Voltage: Match the values ​​specified on the equipment
  • Power Cord: Equipped with an earthing contact
  • Disposal: Must be handed over to the applicable collection point for recycling of electrical and electronic equipment
  • Temperature: Do not switch on immediately after exposure to drastic temperature fluctuation
  • Mains Voltage: Check that the mains voltage corresponds to the indicated value on the label
  • DMX Control: Connect DMX output of controller directly to DMX input of first fixture in a DMX chain
  • Fuse Replacement: Replace with a fuse of the same type and value

Product Usage Instructions

Installation

  • Before carrying out any operations with the unit, carefully read this instruction manual and keep it for future reference.

Power Connection

Before connecting the equipment to the power outlet, verify that the mains voltage and frequency match the values ​​specified on the equipment. If the equipment has a voltage selection switch, connect it to the power outlet only if the equipment values ​​and the mains power values ​​match. If the included power cord or power adapter does not fit your wall outlet, contact your electrician.

CAUTION

  • If the power cord of the device is equipped with an earthing contact, it must be connected to an outlet with a protective ground.
  • Never deactivate the protective ground of a power cord.

Disposal

This product should not be treated as household waste. Instead, it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Proper disposal will help prevent potential negative consequences for the environment and human health.

Temperature Fluctuation

If the device has been exposed to drastic temperature fluctuation, do not switch it on immediately. The condensation water that may arise could damage your device. Leave the device switched off until it has reached room temperature.

Mains Voltage

Check the label on the backside of the product to determine the type of power supply that must be connected. Ensure that the mains voltage corresponds to this specification. Using other voltages than specified can irreparably damage the product. The product must also be directly connected to the mains and should not be used with a dimmer or adjustable power supply.

Circuit Protection

  • Always connect the device to a protected circuit (circuit breaker or fuse) and ensure it has an appropriate electrical ground to avoid the risk of electrocution or fire.

DMX Connection

  • If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first fixture in a DMX chain.
  • Connect the output of one unit with the input of the next fixture until all fixtures are connected.

Caution

  • At the last fixture, you must close the DMX line with a terminating resistor.
  • Take an XLR connector and solder a 120 Ohm resistor between signal (-) and signal (+), then connect it to the DMX output of the last fixture in the line.

Fuse Replacement

If the fuse is defective, replace it with a fuse of the same type and value. Before replacing the fuse, unplug the mains lead. Follow these steps:

  1. Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
  2. Step 2: Remove the old fuse from the fuse holder.
  3. Step 3: Install the new fuse in the fuse holder.
  4. Step 4: Replace the fuse holder in the housing.

SAFETY INSTRUCTIONS

WARNING: Before carrying out any operations with the unit, carefully read this instruction manual and keep it with care for future reference. It contains important information about the installation, usage and maintenance of the unit.

  • Unpack and check carefully that there is no transportation damage before using the unit
  • Please read these instructions carefully and follow the instructions.
  • Observe all safety warnings. Never remove safety warnings or other information from the equipment.
  • Be sure that no ventilation slots are blocked; otherwise the unit will overheated.

CAUTION: Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician.

  • After connecting the unit, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards.
  • Make sure that the power cord is never crimped or damaged. Check the device and the power cord from time to time.
  • Always disconnect power from the mains, when device is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
  • Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
  • Do not switch the unit on and off in short intervals.
  • Do not connect the unit to a dimmer pack.
  • Install the unit in a well ventilated place.
  • Never place any material over the lens.
  • Always allow free air space of at least 50 cm around the unit for ventilation.
  • Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
  • For mounting height >100 cm, always fix the fixture with an appropriate safety-rope. Fix the safety-rope at the correct fixation points only. The safety-rope must never be fixed at the transport handles!
  • Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
  • This unit is not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.

CAUTION: If the power cord of the device is equipped with an earthing contact, then it must be connected to an outlet with a protective ground.
Never deactivate the protective ground of a power cord.

  • Make sure that the unit is not exposed to extreme heat, moisture or dust.
  • Clean the unit using a dry cloth.
  • Do not touch the fixture bare-handed during its operation (housing becomes very hot). Allow the fixture to cool for at least 5 minutes before handling.
  • This unit is designed exclusively for indoor use, do not use this equipment in the immediate vicinity of fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, fluids or gases.
  • If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
  • Never attempt to bypass the thermostatic switch or fuses.
  • Do not dismantle or modify the unit.
  • For replacement use fuses/bulb of same type and rating only.
  • Repairs, servicing and electric connection must be carried out by a qualified technician.
  • The ambient temperature must always be between -5° C and +45° C.
  • If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
  • Plastic bags must be kept out of reach of children.
  • Unit must be installed out of the reach of children. Never leave the unit running unattended.

This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product.

UNPACKING INSTRUCTION

CAUTION:  Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are present and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing materials. In the event that the product must be returned to the factory, it is important that the product be returned in the original factory box and packing. If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.

POWER SUPPLY

  • On the label on the backside of the product is indicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be used.
  • No dimmer or adjustable power supply.

Warning: Always connect the device to a protected circuit (circuit breaker or fuse). Make sure the device has an appropriate electrical ground to avoid the risk of electrocution or fire.

RIGGING

The fixture may be set up on a stable and even surface. By means of the fixing facilities of the baseplate, the unit can also be mounted upside down to a truss, see below picture. For fixing, certified clamps with correct save working load are required. According to the figure, the quick lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit’s weight. Secure the fixture with a safety cable so that it cannot fall down. When carrying out any installation, always comply European and national guidelines concerning rigging, truss and all other safety issues. Always let the installation checked out by an authorized dealer!

DMXS12 CONTROL

  • If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first fixture in a DMX chain.
  • Always connect the output of one unit with the input of the next fixture until all fixtures are connected.

Caution

  • At the last fixture, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor between signal (-) and signal (+) and connect it to the DMX output of the last fixture in the line.

CLEANING

The buildup of dust, dirt and other airborne particles will reduce the fixture’s light output. It will also prevent the fixture from cooling correctly, and this will reduce the fixture’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc. The fixture’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase the tendency for dirt to clog.

To get the best performance and lifetime from the fixture, inspect it regularly and clean it as soon as you see signs of dirt buildup. Assess the operating environment each time you begin to use the fixture. In dusty or smoky conditions, inspect the fixture after a few hours and check it frequently the fixture may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.

Use the following guidelines:

  • Disconnect the fixture from power and allow it to cool completely before cleaning.
  • Do not use solvents, abrasives or any other aggressive product to clean the fixture.
  • Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
  • Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
  • Dry the fixture with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.

REPLACING THE FUSE

If the fuse is defective. replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.

Procedure

  • Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
  • Step 2: Remove the old fuse from the fuse holder.
  • Step 3: Install the new fuse in the fuse holder.
  • Step 4: Replace the fuse holder in the housing.

TROUBLE SHOOTING

The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:

Symptom Possible cause Suggested action
No response from fixture. No power to fixture. Check that the power is

turned on. Check cables and connections.
| Fuse blown or internal fault.| Replace mean fuse or contact Beamz support or Beamz authorized service partner. Do not remove base or yoke covers. Do not attempt to replace a fuse or carry out any repairs or service that are not described in this User Manual unless you have both authorization from Beamz support or Beamz authorized service partner.
Fixture resets correctly but does not respond (or does not respond correctly) to the controller.| The controller is not connected.| Connect controller.
Bad DMX-line.| Inspect connections and cables. Correct poor connections. Repair or replace damaged cables.
| DMX-line has no end resistance.| Insert DMX terminator plug in DMX output socket of last fixture on DMX-line.
| Incorrect fixture addressing.| Check fixture address and DMX mode settings.
| A fixture is defective and is disturbing data transmission on the DMX-line.| Unplug DMX IN and OUT connectors and connect them directly together to bypass one fixture at a time until normal operation is regained. Have defective fixture serviced by an authorized technician.
| Pin 2 and 3 are reversed in XLR connection.| Inspect connections and cables. Install a phase- reversing cable between the fixtures or swap pin 2 and 3 in the fixture, that behaves erratically.
Error after fixture reset.| Effect requires mechanical adjustment.| Check fixture’s software version and error messages for more information. Contact Beamz support or Beamz authorized service partner.
Light output cuts out intermittently.| Fixture too hot.| Allow fixture to cool. Reduce ambient temperature. Ensure free airflow around fixture. Clean fixture if necessary.
| LEDs damaged| Disconnect fixture and contact Beamz support or Beamz authorized service partner.
| The power supply settings do not match local AC voltage and frequency.| Disconnect fixture. Check settings and correct if necessary.

CONTROL MENU

Menu Description
DMX Addr d001-d512 DMX address setting
CHnL 2CH
3CH Channel mode
4CH
5CH
Strb S.01-s.20 Stobe with speed increasing
uL- u.000 ~ u.255 Dimmer
FL– F.000 ~ 255 Zoom function
noDE nod.0
nod.1
nod.2 Dimmer speed
nod.3
nod.4
Id Id01 ~ Id66 ID address setting
tEnP -25 ~ 100 Fixture temperature
UEm Firmware version
rSET Yes Reset
No
pnnF 1.2~24.0 PWM refresh rate adjustment (KHz)

DMX CHANNELS

2 Channels

Channel Function Value Description
1 Dimmer 000-255 Intensity 0-100%
2 Zoom 000-255 Motorised zoom, from 25° to 65°

3 Channels

Channel Function Value Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255 Strobe speed, slow to fast
3 Zoom 000-255 Motorised zoom, from 25° to 65°

4 Channels

Channel Function Value Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255 Strobe speed, slow to fast
3 Zoom 000-255 Motorised zoom, from 25° to 65°
4 Dimmer mode 000-005 No function
006-055 Dimmer mode 0, no delay
056-105 Dimmer mode 1
106-155 Dimmer mode 2
156-205 Dimmer mode 3
206-255 Dimmer mode 4

5 Channels

Channel Function Value Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255 Strobe speed, slow to fast
3 Zoom 000-255 Motorised zoom, from 25° to 65°
4 Dimmer mode 000-005 No function
006-055 Dimmer mode 0, no delay
056-105 Dimmer mode 1
106-155 Dimmer mode 2
156-205 Dimmer mode 3
206-255 Dimmer mode 4
5 ID address 000-009 All ID ID1 to ID
010-019 ID1
020-029 ID2
030-039 ID3
……………… See table later in this manual

Detailed ID Addressing by DMX channel 5 in mode “5 Channels”.

**Value ** Description
 000-009 All ID1-ID66
 010-019 ID1
 020-029 ID2
 030-039 ID3
 040-049 ID4
 050-059 ID5
 060-069 ID6
 070-079 ID7
 080-089 ID8
 090-099 ID9
 100-109 ID10
 110-119 ID11
 120-129 ID12
 130-139 ID13
 140-149 ID14
 150-159 ID15
 160-169 ID16
 170-179 ID17
 180-189 ID18
 190-199 ID19
 200-209 ID20
 210 ID21
 211 ID22
 212 ID23
--- ---
 213 ID24
 214 ID25
 215 ID26
 216 ID27
 217 ID28
 218 ID29
 219 ID30
 220 ID31
 221 ID32
 222 ID33
 223 ID34
 224 ID35
 225 ID36
 226 ID37
 227 ID38
 228 ID39
 229 ID40
 230 ID41
 231 ID42
 232 ID43
 233 ID44
234 ID45
--- ---
235 ID46
236 ID47
237 ID48
238 ID49
239 ID50
240 ID51
241 ID52
242 ID53
243 ID54
244 ID55
245 ID56
246 ID57
247 ID58
248 ID59
249 ID60
250 ID61
251 ID62
252 ID63
253 ID64
254 ID65
255 ID66

TECHNICAL SPECIFICATIONS

  • Rated voltage: 100-240VAC, 50-60Hz, 1.5.-0.8A
  • LED: 200Watt
  • Colour temperature: 3200K
  • Beam angle: 15°-60°
  • Illuminance: 35.750lx
  • Flash rate:  1-19Hz
  • DMX channels: 2, 3, 4 and 5 via 3-pin XLR
  • Dimensions per unit: 341 x 296 x 270mm
  • Weight (per unit): 9.4 kg

Design and product specifications are subject to change without prior notice.

More Information

European Union

  • Tronios B.V.,
  • Bedrijvenpark Twente Noord 18, 7602KR Almelo, The Netherlands
  • 2014/35/EU
  • 2014/30/EU
  • 2011/65/EC

United Kingdom

  • Tronios Ltd.,
  • 130 Harley Street, London WIG 7JU, United Kingdom
  • S.I. 2016:1101
  • S.I. 20181091
  • S.I. 20123032

beamz Pro offers a wide range of high performance lighting equipment and related accessories for the rental, entertainment and architectural lighting markets. BeamZ Pro stands for performance, innovation and value pricing!

BEAMZLIGHTING.COM

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals