BRIZO 8CH-250L Steam Head Installation Guide
- June 15, 2024
- BRIZO
Table of Contents
- BRIZO 8CH-250L Steam Head
- Product Information
- Product Usage Instructions
- FAQ
- STEAM HEAD INSTALLATION
- INSTALLATION INSTRUCTION
- EP103314p & EP103315p STEAMBATH CONTROL INSTRUCTIONS
- Installation
- Operating Instructions
- Limited Warranty on Brizo® Steam Bath and Steam Shower Products
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BRIZO 8CH-250L Steam Head
Product Information
Specifications:
- Date of Purchase: ____
- Manufacturer: Brizo Kitchen and Bath Company
- Model Number: 112969
- Revision: E
Contact Information:
- To reference replacement parts and access additional technical documents and product info, visit www.brizo.com
- For customer support, contact 1-800-355-6478 or visit www.brizo.com/customer-support/contact-us
Product Usage Instructions
Installation:
-
Read all instructions prior to installation.
-
Ensure that the supply elbow and steam supply pipe are securely
anchored to ridged blocking. -
Wrap the threads of the nipple with plumber’s tape or use pipe
sealant. -
The steam head location should be 12 to 18 inches above the
shower floor or 6 inches above the rim of the bathtub, as far from
the seating area as possible. -
Apply silicone to the back edge of the back plate.
-
Screw the steam head onto the nipple and check for proper
alignment. It should be firmly hand tight, do not use a wrench as
it may damage the head. -
If necessary, the head can be repositioned by disassembling the
hub from the cover and selecting one of the two alternate
positions.
Head Assembly:
If needed to improve bather comfort, the optional steam deflector can be
installed to block the flow of steam from any of the shown sides of the steam
head.
Warranty
Brizo Kitchen and Bath Company provides a lifetime limited warranty for the
parts (except for electronic parts) of its residential steam bath generator.
This warranty applies to the original consumer purchaser who owns the home in
which the steam bath was originally installed. Commercial applications are not
covered by this warranty.
FAQ
-
How do I contact customer support?
You can contact customer support by calling 1-800-355-6478 or visiting www.brizo.com/customer-support/contact-us. -
Can the steam head be repositioned?
Yes, if necessary, the steam head can be repositioned by disassembling the hub from the cover and selecting one of the two alternate positions.
STEAM HEAD INSTALLATION
Read all instructions prior to installation.
CAUTION
Failure to read these instructions prior to installation may result in
personal injury, property damage, or product failure. Manufacturer assumes no
responsibility for product failure due to improper installation.
You may need:
INSTALLATION INSTRUCTION
Rough In Steam Line (not supplied)
-
Prior to steam head installation, Install rough plumbing line to desired location. The steam head must be installed to a ¾” NPT copper or brass pipe; do NOT use black iron or galvanized pipe, it will rust and discolor the steam bath wall. Do NOT use plastic supply pipes or fittings.
NOTE: Supply elbow and steam supply pipe MUST BE SECURELY ANCHORED to ridged blocking. -
The steam head location should be 12” to 18” above the shower floor or 6” above the rim of the bathtub, as far from the seating area as possible.
Steam Head Installation
-
Make sure the 3/4” nipple protrudes beyond the tile ¼” to ½” (6-12 mm).
-
Keep opening in finished wall close as possible to pipe nipple with no more than 1/2” gap.
IMPORTANT: If the nipple protrudes beyond ½” the O-ring will not make a proper seal and the nipple will have to be adjusted. -
Wrap the threads of the nipple with plumber’s tape or use pipe sealant.
-
Make sure the steam head will line up in the upright position when tightened. The steam head should only be firmly hand tight. Using a wrench on the head may damage it. Screw the steam head on to the nipple and see how it lines up. Once a proper alignment is made remove the steam head.
* **NOTE:** The steam head has been designed with a 360 degree dispersion of steam to improve steam circulation and to minimize the hotspots created with the traditional steam heads. For maximum comfort the steam head should always be located as far from the seating area as possible. Should the location of the steam head necessitate blocking the steam from a particular direction to improve bather comfort, the supplied deflector plate can be added to any of the three sides shown to help divert the steam away from the bather. The deflector is attached to the back side of the head before installation with 2 stainless steel screws provided. (See Option Installation, Deflector section on next page).
* **NOTE:** If necessary the head can be repositioned by disassembling the hub from the cover and selecting one of the two alternate positions.
1. Re-apply sealant tape if necessary.
2. Place a bead of silicone around the pipe, sealing the pipe to the wall.
3. Place a bead of silicone around the back outer edge of the back plate.
4. Center and square the back plate over the nipple. While holding the head in place, attach the nipple by hand tightening the screws to the head.
5. Adjust the back plate and head to line up squarely. Remove any excess silicone with rubbing alcohol.
Optional Installation
-
IMPORTANT: A silicone boot is provided and should be installed to protect against accidental contact with the hot surface temperature of the steam head, which can reach approximately 212° during operation.
-
If needed to improve bather comfort the included optional steam deflector can be installed to block the flow of steam from any of the shown sides of the steam head.
EP103314p & EP103315p STEAMBATH CONTROL INSTRUCTIONS
IMPORTANT: “Steam bath important safety instructions” publication 114317 includes a warning label that the contractor must install on the wall near the entrance to the steam room in a highly visible location. This label and its additional safety information are packaged with the generator packaging containing the installation instructions. If it is lost or missing contact: customer support (1-800-394-6478) for replacement instructions. This publication, along with all documents, must be left with the owner.
Control Features
- Temperature Display: The digital readout displays the ambient temperature, set point and cycle time, system status, and diagnostic error codes.
- Steam Icon: When illuminated, the steam cycle is running.
- Water Icon: When steam shower is not in use, the blue water icon indicates the RapidMist feature is on. This is also illuminated during a steam bath cycle.
- Menu button: Used to change cycle time, turn *RapidMist on or off, and switch between ºF and ºC. When steam is off, pressing this button will toggle between these settings. The settings are changed with the up/down arrow buttons.
- Stop button: Pressing this button stops the current steam cycle and the Menu mode.
- User 1 button : Starts the user one cycle and is the up function when changing Menu settings. Pressing this button while in a cycle will change the temperature and remaining time left on that cycle.
- User 2 button: Starts the user two cycle and is the down function when changing Menu settings. Pressing this button while in a cycle will change the temperature and remaining time left on that cycle.
IMPORTANT: This control must be installed inside the steam room for proper operation of the system.
Cleaning instructions: Use a damp cloth and mild soap. Do NOT use abrasive cleaners which might scratch the surface or the base of the control.
Installation
-
Pre-Installation – Control Location
The Control must be installed inside the steam room and not above the steam head. For convenience the recommended height from the floor is four feet. Provide a 1½” hole in the wall at this location (see Figure 1).
IMPORTANT: Multi-conductor cable must be installed so that the end will not be buried inside the wall. The unit will not operate unless the control is installed. -
Electrical Rough-in
Locate the multi-conductor cable. Carefully route the multi-conductor control cable from the steam generator to the control located inside the steamroom (see Figure 1). Route multi-conductor cable through a ¾” conduit to protect the cable from damage. -
Control and Cable Installation
-
Locate the previously installed cable and black plastic strain relief clamp which is in the control packing box. Locate the knockout on the steam generator for the control cable (see Figure 2).
-
Place strain relief around cable about seven inches from the end and insert into the hole. Remove the protective covering labeled “Remove Before Installation” from the modular jack found on the PC board.
-
Remove the protective cap from the multi-conductor cable plug. Connect the cable to the modular jack.
-
Close and secure generator cover.
-
Locate Telco Jack at female coupler, on back of the control. Remove the protective covering labeled “Remove Before Installation”. Remove protective cap from cable and plug into jack. Check that the orientation of the plug properly aligns with the jack. A snap will indicate the plug is installed correctly (see Figure 3).
WARNING Test the control for operation before continuing on to the next step. -
Peel adhesive liner from back of the control. Apply the control to the wall. Press firmly and hold for a few seconds.
-
After the control is in place, apply silicone (supplied) around the control to form a watertight seal (see Figure 3).
-
Operating Instructions
-
Operation: Make sure the water and power are turned on. Simply press User 1 or User 2 button to begin the cycle. Press the Stop button to end the cycle. After a cycle is started it will take a few minutes for the Steam Generator to heat up and begin producing steam. This time will be less if the RapidMist has been turned on. During operation the display will show the ambient temperature.To view the remaining cycle time, press the Menu but-ton.
-
Programming: Adjustments can be made to temperature and cycle time while a cycle is started. When the temperature is displayed, the set tempera-ture can be viewed or changed by momentarily pressing the up or down button. Temperature adjustments made when User 1 cycle is started will be saved to User 1 and likewise for User 2. All changes made to the temperature control are stored in memory until changed again.
The temperature range is 60°F to 125°F (16°C to 52°C). While a cycle is running, pressing the Menu button will show the remaining cycle time and this can be adjusted with the up or down buttons. This time adjustment is only for remaining time of the current steam bath cycle. -
Default Time Setting: The default time is programmed when the cycle is off using the Menu button. Any adjustments made to time, when the cycle is off, are stored as the new default time for both users.
-
RapidMist Setting: The RapidMist feature can be turned on or off when the steam cycle is in the off mode. To adjust this setting, press the Menu button until you see the Water Icon, press the Up or Down button to change this setting. Display “On” or “Off” will appear. RapidMist keeps the steam generator warm, for a faster heat up.
-
Fahrenheit or Celsius setting: To change this setting, while the steam cycle is off, press the Menu button until you see an “F” or “C” in the display. Use the up or down button to change the displayed letter, to correspond to your temperature choice. Press the Stop button to exit the Menu mode. Your last setting will be saved.
NOTE: The EP103314 & EP103315 controls operate and install the same way. The only difference between them is the physical shape.
Additional Features
- Memory: The temperature set points for User 1, User 2, the default time, and the selection of RapidMist and other settings are retained even if there is a power failure.
- Service Mode : To enter the service mode press and hold the Menu button for 5 seconds, until a blue dot lights up in the display. The control is now in the service mode. There are two features in the service mode. Pressing the up arrow displays the program version, pressing the down arrow, restores to factory default.
- Error Messages: This control is programmed with a diagnostic feature to help isolate any potential problems. Errors are displayed by flashing an “Er” followed by a 2 digit number. The first digit is the device number. Zero for the control and 1-4 for the generators. The second digit is the error code for that device. Error message “Er 01”, “Er 02”, and “Er 04” indicate a problem internal to the control. If this occurs, the control should be replaced. Error messages “Er 03” means the control could not communicate with a steam generator and may be a cable connection problem. If this error oc-curs, check both ends of the control cable for clean, dry and secure connections. Dirty contacts can be cleaned with alcohol and a cotton swab or a toothbrush. This can also happen if the control is not sealed and the cable connections get wet. Also make sure the generator is not in test mode. Try resetting the breaker. Generator error codes are not covered in this document.
Limited Warranty on Brizo® Steam Bath and Steam Shower Products
Applicable to products purchased and installed in the USA and Canada
-
Residential Steam Bath Generators:
-
- Brizo Kitchen and Bath Company (“Brizo”) warrants to the original consumer purchaser that the parts (except for electronic parts) of its residential steam bath generator purchased from authorized Brizo sellers will be free from defects in materials and workmanship for as long as the original consumer purchaser owns the home in which the steam bath was originally installed. This lifetime limited warranty does not apply to residen-tial steam bath generators that are used in commercial applications (as defined herein).
- Residential Electronic Parts, Controls, Spa Options and Accessories: Brizo warrants to the original consumer purchaser that the electronic parts of its steam bath generator and its controls, spa options and accessories purchased from authorized Brizo sellers will be free from defects in materials and workmanship for a period of two (2) years from the date that the product is received by the original consumer purchaser or their authorized representative (installation contractor, etc.). This two-year limited warranty does not apply to controls, spa options, electronic parts and accessories that are used in commercial applications (as defined herein).
-
Commercial Warranty:
-
- For the purposes of this warranty the term “commercial application” refers to installation in any setting in which the product is not being used for personal household use, including, but not limited to, hospitality applications, day spas and short-term and long-term rentals.
- Brizo warrants that the parts (including electronic parts) of its steam bath generators (including steam bath generators with model numbers beginning with 8GE that are 7.5kW-15kW), equipment, controls, electronic parts, spa options and accessories purchased from authorized Brizo sellers and used in a commercial application will be free from defects in materials and workmanship for a period of one (1) year from the date that the product is received by the original purchaser or their authorized representative (installation contractor, etc.).
-
What We Will Do:
-
- Brizo will, at its option, repair or replace, free of charge, any part that proves defective in material and/or workmanship under normal installation, use and service during the applicable warranty period as stated above. Brizo may elect to refund the purchase price. Replacement parts are subject to availability and may differ from those originally supplied.
- For residential applications, two (2) years following the date that the product was received by the original consumer purchaser or their authorized representative (installation contractor, etc.) and with prior approval by Brizo, Brizo will pay for labor for repair/replacement associated with warranty coverage. Thereafter, Brizo will not pay for labor associated with removal/repair/replacement of products covered by this warranty.
- For commercial applications, Brizo will, with prior approval by Brizo, pay for labor associated with warranty coverage for ninety (90) days from the date that the product is received by the original purchaser or their authorized representa-tive (installation contractor, etc.). Thereafter, Brizo will not pay for labor associated with removal/repair/replacement of products covered by this warranty. These are the consumer’s exclusive remedies.
-
What Is Not Covered:
Because Brizo is unable to control the quality of Brizo products sold by unauthorized sellers, unless otherwise prohibited by law, this warranty does not cover Brizo products purchased from unauthorized sellers. This warranty does not cover damage caused by improper or negligent installation or use. Provided that Brizo is paying the cost of the labor under the terms above, this warranty does not cover repairs attempted by any person other than an authorized Brizo agent and shall be limited to the repair or replacement of defective parts by Brizo or its authorized agent. -
This warranty is void if any of the following should occur:
-
- The use of the product for an unintended application, including a commercial application for all products except those products for which a commercial application is appropriate.
- Failure to follow instructions, including care, cleaning and usage instructions, provided in the product’s owner’s manual.
- The product’s serial number has been altered or removed.
- The product is modified in any manner which Brizo concludes, after its inspection, affects the reliability of the product.
- The product has been improperly repaired by anyone not specifically designated or authorized by Brizo.
- The product is damaged because it is not operated or installed in accordance with supplied instructions.
- The product is installed outdoors.
- The product is installed in a moist and/or humid area with unconditioned air or temperatures that exceed 104 degrees Fahrenheit.
- The product is damaged due to freezing.
- The product is damaged by acts of God.
-
How to Make a Warranty Claim:
To obtain warranty repair or replacement, contact Brizo at: 800-355-6478 or steam- prodserv@brizo.com to receive an RGA# (Return Goods Authorization number) which must be on the carton that is returned via UPS Ground or equivalent. Proof of purchase (original sales receipt showing purchase date) identifying the model and serial number and documentation of the date of receipt of the product by the original purchaser or their authorized representative (installation contractor, etc.) must accompany all warranty claims. -
Limitation on Duration of Implied Warranties:
Please note that some states/provinces (including Quebec) do not al-low limitations on how long an implied warranty lasts, so the below limitations may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, IS LIMITED TO THE STATUTORY PERIOD OR THE DURATION OF THIS WARRANTY, WHICHEVER IS SHORTER. -
Limitation of Special, Incidental or Consequential Damages:
Please note that some states/provinces (including Quebec) do not allow the exclusion or limitation of special, incidental or consequential damages, so the below limitations and exclusions may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS WARRANTY DOES NOT COVER, AND BRIZO SHALL NOT BE LIABLE FOR, ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER ARISING OUT OF BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, BREACH OF CONTRACT, TORT, OR OTHERWISE. -
Additional Rights:
This warranty gives you specific legal rights, and you may also have other rights which vary from state/province to state/province. This is Brizo’s exclusive written warranty and the warranty is not transferable.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>