Omnitron Systems 8270-1 1 Module Industrial Power Chassis User Manual

June 13, 2024
Omnitron Systems

Omnitron Systems 8270-1 1 Module Industrial Power Chassis User Manual
Module Industrial Power Chassis

General and Copyright Notice

This publication is protected by U.S. and international copyright laws. All rights reserved. The whole or any part of this publication may not be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means, manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission of Omnitron Systems Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.: FlexPointTM,
Flex SwitchTM, HybridNID® i Converter® , mi ConverterTM, Net Out look® , Omni Light® OmniConverter® Rugged Net® Monition Systems Technology, Inc.TM, OSTTM and the Monition logo

All other company or product names may be trademarks of their respective owners.

The information contained in this publication is subject to change without notice. Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.

Warranty

This network product and the included AC/DC power adapter are warranted to the original purchaser (Buyer) against defects in material and workmanship for a period of two (2) years from the date of shipment. The warranty for the network product can be extended to lifetime by registering the product at www .omnitron-systems.com/support within ninety (90) days from the date of shipment. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective with the same product or with a product with at least the same functionality.

For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to product malfunctions resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.

Environmental Notices

****The equipment covered by this manual must be disposed of or recycled in accordance with the Waste Electrical and Electronic Equipment Directive (WEEE Directive) of the European Community directive 2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/EU, for electrical and electronic equipment sold in the EU after July 2019. Such disposal must follow national legislation for IT and Telecommunication equipment in accordance with the WEEE directive: (a) Do not dispose waste equipment with unsorted municipal and household waste. (b) Collect equipment waste separately. (c) Return equipment using collection method agreed with Omnitron.

The equipment is marked with the WEEE symbol shown to indicate that it must be collected separately from other types of waste. In case of small items the symbol may be printed only on the packaging or in the user manual. If you have questions regarding the correct disposal of equipment go to www.omniton- systems.com/support or e-mail to Omnitron at [email protected].

Safety Warnings and Cautions

ATTENTION: Observe precautions for handling electrostatic discharge sensitive devices.
WARNING: Potential damage to equipment and personal injury.
WARNING: Risk of electrical shock.

Product Overview

The iConverter 1-Module Industrial Power Chassis featuring a single or dual DC terminal power connection supporting 12 to 36VDC or 20 to 60VDC providing flexible installation options.
Module Industrial Power Chassis
1-Module Industrial Power Chassis

Model Number Description
8270-1-1 1-Module Chassis +/-12 to +/-36 VDC, Single Power Input
8270-1-2 1-Module Chassis +/-12 to +/-36 VDC, Dual Power Input
8270-2-1 1-Module Chassis +/-20 to +/-60 VDC, Single Power Input
8270-2-2 1-Module Chassis +/-20 to +/-60 VDC, Dual Power Input

Use the Power Calculator to verify the iConverter chassis power supplies will meet the requirements of the installation.
Dying Gasp Trap
The 1-Module Industrial Power Chassis feature Dying Gasp Trap which reports loss of power input or chassis power supply failure. This feature requires an iConverter management module be installed in the chassis (ie 10/100M2, GXTM2, GM3). When power failure occurs, the chassis reserves enough power to keep the installed module running in order to send a final SNMP alert to the management software.

Wall Mounting

The 1-Module chassis can be wall mounted by installing the optional Wall Mount Plate (8260-3). Refer to the Wall Mount Plate user manual (040-08260-301x) for the proper installation guidelines.
The wall mounting height of the module should be less than or equal to 2 meters (6.6 feet)
from the floor. Use the four mounting holes on the module to secure the module to the wall. The module can accommodate #6 screws (not included).
Installation of the module should be such that the air flow in the front, back, side and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on the module.

Rack Mounting
The 1-Module chassis can be rack mounted by installing the optional Wall Mount Plate (8260-3). Two 1-Module chassis can be rack mounted using the optional Rack Mount Shelf (8260-0). Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper installation guidelines.
Follow the same Wall Mounting guidelines when rack mounting the module.
DIN-Rail Mounting
The module can be DIN-Rail mounted using the attached DIN-Rail mounting bracket.

Installing Modules

Carefully slide the modules into an open slot in the chassis. Align the modules with the installation guides and ensure that the modules are firmly seated against the backplane.
Secure the modules by fastening the front panel thumbscrew (push in and turn clockwise to tighten) to the chassis front.

Applying DC Power
Power source should be available within 5 ft. of the chassis. The over current protection for connection with centralized DC shall be provided in the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and installed per the National Electrical Code, ANSI/NFPA-70.
The 1-Module Industrial Chassis supports two powering options. The 8270-1 requires 12 to 36VDC (1.5A @ 12VDC max rated power) and the 8270-2 requires 20 to 60VDC (0.8A @ 20VDC max rated power). See specification table for specific model requirements.
Appropriate overloading protection should be provided on the DC power source outlets utilized.

WARNING: OnlyaDC power source that complies withsafety extra low voltage (SELV) requirements can be connected to the DC-input power supply.

WARNING REGARDING EARTHING GROUND:

  • This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected.
  • This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor, and also the point of earthing of the DC system. The DC system shall not be earthed elsewhere.
  • The DC supply source is to be located within the same premises as this equipment.
  • There shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the earthing electrode conductor.

Locate the DC circuit breaker of the external power source, and switch the circuit breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires.

Connect the ground wire to the grounding screws on the back of the module.

Ground Screw Location
Connect the power cables to the module by fastening the stripped ends to the DC power connector.

WARNING: Note the wire colors used in making the positive, negative and ground connections. Use the same color assignment for the connection at the circuit breaker.
Connect the power wires to the circuit breaker and switch the circuit breaker ON. The chassis power LEDs (Pwr A and Pwr B) will indicate the presence of power. If any module is installed, the module Power LED will be illuminated.
Installation of the equipment should be such that the air flow in the front, back, side and top vents of the chassis are not compromised or restricted.

Supported Modules

The following table indicates the supported modules for the 1-Module Industrial chassis over the specific operating temperature ranges.

Speed| Module Name / Base Model #| Commercial Temp 0 to 50°C| Wide Temp-40 to 60°C| Extended Temp-40 to 75°C
---|---|---|---|---
100Mbps| 10/100 / 838x-x| x| x| x
1000Mbps| 4GT / 8482-4| x| x| x
2GXT / 8484-4| x| x| x
1000Mbps| GX/X / 854x-xx| x| x| x
100 and 1000Mbps| GX/F / 856x-xx| x| x| x
6Gbps to 11.32Gbps| XG / 8599P-xx| x| |
XG+ / 8599R-xx| x| x| x
1Mbps to 8.5Gbps| xFF / 8699-x| x| x| x
Serial| RS232 / 876x-x| x| x| x
RS422/485 / 878x-x| x| x| x
Managed 100Mbps| 10/100M2 / 890xN-x| x| x| x
2FXM2 / 8959N-0| x| x| x
| | | |

Managed 1000Mbps

| GX/TM2 / 892xN-x| x| |
GM3 / 892xP-x| x| x| x

LED Indicators
Verify the module is operational by viewing the Power LED indicators.

Power LED Indicators

Legend| Indicator| Description
Pwr A| OFF| Unit not powered
Green – ON| Unit powered by power supply input A
Pwr B| OFF| Unit not powered
Green – ON| Unit powered by power supply input B

Specifications

Model Number 8270-1 8270-2
Description 1-Module DC 12 to 36 VDC 1-Module DC 20 to 60 VDC
Regulatory Compliances Safety:                    UL, CE, NEBS

Level 3, UKCAEMI:                         FCC Class AACT: TAA, BAA,NDAA
Environmental| RoHS, WEEE, REACH
Input Power Requirements (typical)| +/-12 to +/-36 VDC 1.5A Max @ 12VDC| +/-20 to +/-60 VDC 0.8A Max @ 20VDC
Output Power| 10.0 watts 3.0A @ 3.3VDC
Power Connector| 2 Position Terminal
Dimensions W x D x H| 1.5″ x 5.5″ x 5.5″ (38.1 mm x 139.7 mm x 139.7 mm)
Weight| 1.5 lbs. (0.68 kg)
Temperature| Commercial:        0 to 50°C Wide: -40 to 60°CExtended:              -40 to 75°CStorage:                 -40 to 80°C
Humidity| 5 to 95% (non-condensing)
Altitude| – 100m to 4,000m
MTBF (hrs)| 517,000
Warranty| Lifetime warranty with 24/7/365 free Technical Support

Customer Support Information

Phone: 949-250-6510
Fax: 949-250-6514
Address: Monition Systems Technology, Inc. 38 Tesla Irvine, CA 92618, USA
Email: [email protected]
URL: www.omnitron-systems.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Omnitron Systems User Manuals

Related Manuals