WARNING!

  • Poor ventilation or heater positioning may lead to dry distillation, posing a fire risk under certain circumstances!
  • Insufficient insulation of the sauna cabin may pose a fire risk!
  • Use of the wrong materials in the sauna cabin, such as particle board, drywall, etc., may pose a fire risk!
  • The heater must be connected by a qualified electrician pursuant to applicable regulations!
  • No more than one heater may be installed in the same sauna cabin.
  • The air exhaust vent must not lead outdoors. This could cause the ventilation direction to be reversed, which may negatively affect the heater temperature cut-out.
  • Any gap above the sauna ceiling should not be sealed without leaving at least one vent hole on the same wall as the sauna door!
  • Always check that the heater is connected to the correct main/phase voltage!
  • Anyone with a mental or physical disability or little experience or knowledge of how to use the equipment (e.g. children) must be instructed or supervised by someone responsible for their safety.
  • Touching the upper parts of the heater may cause burn injuries. Tylö recommends always using the heater screen.
  • Never allow children to play near the heater!
  • Saunas are not recommended for people in poor health. Please consult a doctor.
  • Fragrant essences and similar products may ignite, if poured directly onto the stones.
  • Covering the heater may cause a fire.
  • Never put fragrances in the herb bowl or water reservoir.
  • If the stone compartment fills up with gravel and small stones, the tubular element can be damaged as a result of overheating, as air flow will be insufficient.
  • The sauna room or cabin is to be inspected before either restarting the timer or by switching on the appliance by a separate remote-control system
  • The sauna room or cabin is to be inspected before setting the appliance to a standby mode for a delayed start
  • Thermostat sensors have to be installed so that they are not influenced by incoming air
  • The door of the sauna room or cabin is fitted with an interlock such that the stand-by mode setting for remote operation is disabled if the sauna door or cabin door is opened when the stand-by mode setting for remote operation is set
  • Means for full pole disconnection must be incorporated in the fixed wiring in accordance with the wiring rules
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in  a safe way and understand the hazards involved
  • Children shall not play with the appliance
  • Cleaning and user maintenance shall not be made by children without supervision

PRIOR TO INSTALLATION

Parts
Check that the following parts are included in the packaging:

TYL Sense Crown Combi Elite - Parts

  1. Sauna heater x 1
  2. Herb Strainer x 1
  3. Hose x 1
  4. Valve x 1
  5. Emptying spout x 1
  6. Tilt protection x 2
  7. Warning sticker in ten languages x 1
  8. Connectors x 3
  9. Emptying Hatch x1
  10. Screw B4x6,5 x 2
  11. Clips TC (3-5) x 10 pieces
  12. Plastic plugs 25×5 x 2 pcs
  13. Screws B6x25 x 2 pcs
  14. Humidity- and temperature sensor and Cover
  15. Cable between heater and humidity- and temperature sensor, RJ10 4P4C, cable length 4 m x 1 pce
  16. Control panel Elite
  17. Cable between heater and control panel, RJ10 4P4C, cable length 5 m x 1 pce
  18. Cable tie
  19. Clips C3x5 x 10 pieces
  20. Modular plug 4, 4/4RJ10 x 2
  21. Plastic plugs 25×5 x 2 pcs
  22. Screws B6x25 x 2 pcs
  23. Protection hose Ø14×150 mm x 3 pcs, for RJ10 cables (sensor, control panel, door switch)
  24. Door contact

Contact your dealer if anything is missing.
Control panel Pure is supplied with Sense Combi Pure.
Control panel Elite is supplied with Sense Combi Elite.
See separate guides.

Installation requirements
To ensure safe use of the heater, check that the following criteria are met:

  • All wiring must be performed in accordance with national and local codes
  • Use H07RN-F (60245 IEC 66) cables or a corresponding type
  • The cables must be installed correctly (see the Connection/wiring diagram section, Figure 18).
  • The fuse size (A) and the power cable size (mm²) must be suitable for the heater (see the Connection/wiring diagram section, Figure 18).
  • The sauna ventilation must comply with the instructions in this manual (see the Air intake valve positioning section, Figure 6, the Air exhaust valve positioning section, Figure 6).
  • The position of the sauna heater, control panel and sensors must comply with the instructions in this manual.
  • The heater’s output (kW) must be adapted to the sauna’s volume (m³) (see Table 1). The minimum and maximum volumes must not be exceeded.
  • The walls and ceiling of a sauna room should be thermally well insulated. It is recommended to use wooden panel cladding inside the sauna room.

NOTE! A glass-, or brick wall without heat insulation increases the warm- up time. Each square meter of uninsulated ceiling or wall surface equals an additional 1–2 m³ of sauna volume.

Table 1: Output and sauna volume

Output kW Sauna volume min./max. m³
6,6 8-Apr
8 12-Jun
10,8 18-Oct

DANGER! Poor ventilation or heater positioning may lead to dry distillation, posing a fire risk under certain circumstances!
DANGER! Insufficient insulation of the sauna cabin may pose a fire risk!
DANGER! Use of the wrong materials in the sauna cabin, such as particle board, drywall, etc., may pose a fire risk!
DANGER! The heater must be connected by a qualified electrician pursuant to applicable regulations!

Installation tools
The following tools and materials are needed for installation and connection:

  • water level,
  • adjustable spanner,
  • electric drill,
  • screwdrivers.

Installation planning
Before starting to install your sauna heater:

  • Plan the sauna heater positioning (see the Heater positioning
    – normal installation section, Figure 3).

  • Plan the control panel positioning (see the attached instruc- tions for the control panel for allowable positioning). See also the Control Panel section, Figure 5.

  • Plan the sensor positioning (see Figure 3 and Figure 4).

  • Position the air intake vent (see the Air intake vent positioning section, Figure 6).

  • Position the air exhaust vent (see the Air exhaust vent posi- tioning section, Figure 6).

  • Plan the electrical installation (see the Connection/wiring diagram section, Figure 18).

TYL Sense Crown Combi Elite - diagram of installation

  1. Sauna heater
  2. Control panel
  3. Sensor
  4. External on/off switch (option, door contact needed for function)
  5. Door contact

Positioning the heater – normal installation
DANGER! No more than one heater may be installed in the same sauna cabin.

Position the sauna heater:

  • on the same wall as the door (or the side wall if very close to the door wall).
  • Position the heater at a safe distance from the floor, side walls and interior fittings (see Figure 3).

Position the sensor according the picture (see Figure 3). Shut any active air inlet with in 1000 mm from the sensor,

TYL Sense Crown Combi Elite - the heater

  1. Minimum distance from side wall: 50 mm
  2. Sensor position alt 1: 300 mm from heater
  3. Sensor
  4. Minimum distance from back wall: 50 mm
  5. Sensor position alt 2: 300 mm from heater front
  6. Sensor position: 150 mm from ceiling
  7. Minimum distance from interior fittings: 50 mm
  8. Minimum ceiling height: 1900 mm
  9. Minimum distance: 20 mm
  10. Minimum distance from interior fittings: 30 mm

If the wall on which the sensor is to be installed is made of highly heat- absorbing material (e.g. concrete, brick, etc.), or of hardened glass, the sensor may be installed in the ceiling at a distance from the heater, according to Figure 4.

TYL Sense Crown Combi Elite - Sensor installation

1. 300 mm

Placement of the Tylö Elite control panel
Where possible, placement of the control panel outside the sauna room is recommended due to lower ambient temperatures.
The control panel may be placed inside a Tylö sauna room or a self-built sauna room with correct ventilation which operates according to Tylö-recommended ventilation (natural ventilation principle). Read the sections titled, Positioning the intake vent and Positioning the outlet vent in these instructions. The control panel must always be placed outside the sauna cabin if these requirements are not met. If installing the control panel inside the sauna cabin, it should be positioned with regard to safety distances and installation height, see Figure 5.

WARNING! With incorrect ventilation, a control panel fitted inside the sauna cabin may be exposed to excessive temperatures, which can cause the control panel to become deformed or defective. The ambient temperature around the control panel should  never exceed 80°C.

TYL Sense Crown Combi Elite - control panel

  1. Heater
  2. Control panel Elite
  3. Max. 800 mm
  4. Min. 300 mm

Positioning the inlet vent
Install the inlet vent straight through the wall under the center line of the heater.
Vent size for a family sauna approx. 125 cm².
The air circulation from the door must concord with the hot air circulation from the heater.

TYL Sense Crown Combi Elite - the heater 2

  1. Inlet vent position.
  2. Outlet vent position through the sauna wall.
  3. Outlet vent position through the cavity.
  4. Outlet vent position via duct.

Positioning the outlet vent
DANGER! The air exhaust vent must not lead outdoors. This could cause the ventilation direction to be reversed, which may negatively affect the heater temperature cut-out.
DANGER! Any gap above the sauna ceiling should not be sealed without leaving at least one vent hole on the same wall as the sauna door!

Position the outlet vent

  • at the maximum possible distance from the air intake vent, e.g. diagonally (see Figure 6).
  • high on the wall or in the ceiling (see Figure 6).
  • so that it vents into the space that the door and air intake vent open into.

The outlet vent must have the same area as the inlet vent.
Ensure that the inlet and outlet vent are open.
Mechanical ventilation is not recommended due to the risk of poor air exchange, which can negatively affect the heater temperature cut-out.

INSTALLATION

Sauna heater installation

  1. Place the heater so the hatch on the left side is free to make it easier to emptying the tank after use.
    TYL Sense Crown Combi Elite - Orientation of the
heaterTYL Sense Crown Combi Elite - the heater
3TYL Sense Crown Combi Elite - the hidden
screws

  2. Lift of the front panel and front hatch, see Figure 8.

  3. Undo the two screws on the back, remove the cover to the water reservoir (see 1 in Figure 9) Undo the screws on the sides. (see 2 in Figure 9).
    TYL Sense Crown Combi Elite - remove the back cover

  4. Flex out the sides and remove the back cover (see 1 in Figure 10). Remove the lower hatch (see 2 in Figure 10).
    TYL Sense Crown Combi Elite - the back cover WARNING! Always check that the heater is connected to the correct main/phase voltage!
    Connect the heater using standard wiring (Fk or EKK) approved for fixed installation.
    Any single wires (Fk) must be protected in electrical conduits (VP) to the heater.

  5. Connect the electrical cable (see Figure 11) according to the wiring diagram (see Figure 18).
    TYL Sense Crown Combi Elite - Electrical compartment1. Electrical cable
    2. Terminal for connection of electrical cable
    3. 16 mm Knock outs
    4. Control panel cable
    5. Modular contacts for connection of control panel, sensor etc.
    6. Sensor cable
    7. Light cable (if relevant)
    8. Terminal for connection of light + Aux (if relevant)
    9. Strain relief connector for cables to modular contacts (x2)
    10. Strain relief connector for electrical cable
    11. Protection hose for RJ10 cables

  6. Run the cables for the control panel and the temperature sensor through the cable grommets (see Figure 11). Connect the control panel cable to one of the four RS485 contacts (positions 6-9) (see Figure 20).

  7. Connect the humidity- and temperature sensor cable (positions 6-9)(see Figure 20). Pull out the drawer to stretch the cables and tighten the strain relieves (see Figure 12).

  8. Connect the light / Aux cable , see Figure 10, according to the wiring diagram Figure 18 (if relevant)

  9. Push back the drawer, mount the front and back hatch and tighten the screws, (see Figure 13)
    TYL Sense Crown Combi Elite - Pull out the drawer for easier
access![TYL Sense Crown Combi Elite

  • Put back the front and back hatch](https://manuals.plus/wp- content/uploads/2023/12/TYL-Sense-Crown-Combi-Elite-Put-back-the-front-and- back-hatch.jpg)

    1. Mount the emptying hose, tighten the valve, click in the spout and tighten the hose on the water reservoir (see Figure 14).
      TYL Sense Crown Combi Elite - Mounting of the emptying
hose

    2. Put back the front and back cover and tighten the screws, see Figure 15.

    3. Put back the cover to the water reservoir, tighten the screws and hook on the water drain hatch.
      TYL Sense Crown Combi Elite - the cover to the water

    4. To make sure the heater stands stable, adjust the feet.

    5. Install the sensor on the wall see Figure 16. The thermistor wire may also be passed through the wall. Seal any holes in the wall behind the sensor, see figure 17. The thermistor wire may be extended outside the sauna using low voltage wire (2-, 4-lead).
      TYL Sense Crown Combi Elite - The cableTYL Sense
Crown Combi Elite - the wall

Unusual voltages/numbers of phases
Contact Tylö Customer Service before connecting to voltages or numbers of phases that are not listed in the wiring diagram Figure 18.
External ON/OFF switch (option)
External ON/OFF switch can be installed anywhere outside the sauna. The switch works for impulse or constant deactivation.
The heater circuit automatically recognizes which is used. Heater status and faults on the door contact can be seen if the switch has a built-in LED.
See instructions supplied with the external switch.
Door contact
The door contact is necessary to be able to use the Elite panel’s calendar function, plus remote control the sauna via external switch, mobile or PC apps.
See instructions supplied with the door contact.

CONNECTION/WIRING DIAGRAM

TAB| 400-415 V 3N- (C)| 200-208 V 3- (B)| 230 V 3- (B)| 200-208 V- (A) | 230-240 V- (A)
---|---|---|---|---|---
Output
kW| Amperage
amp| Conductor
area mm2| Amperage
amp| Conductor
area mm2| Amperage
amp| Conductor
area mm2| Amperage
amp| Conductor
area mm2| Amperage
amp| Conductor
area mm2
6,6| 10| 1,5 (fig 22)| 19| 4| 17| 4| 33| 10| 29| 10
8| 12| 2,5| 23| 6| 20| 4| 40| 16| 35| 10
10,8| 16| 2,5| 32| 10| 28| 10| –| –| –| –

  • 10,8 kW is not approved for singel phase in Europe

TYL Sense Crown Combi Elite - Wiring diagram

  1. Heater
  2. Humidity- and temperature sensor – Combi Elite
  3. Control panel
  4. External switch (option)
  5. Door contact
  6. Light/terminal for connection of light
  7. Terminal for connection of power cable

TYL Sense Crown Combi Elite - Combi Elite

R=Red, G=Green, W=White, B=Black

TYL Sense Crown Combi Elite - Schematic diagram of
installation

SELF-INSPECTION OF THE INSTALLATION

To check the installation:

  1. Switch on the mains supply to the heater from the distribution board.
  2. Switch on the heater, use the lever, see figure 21
  3. Check that the control panel lights up, takes approx. 1 minute
  4. Start the heater (see User guide). The light turns on.
  5. Check that all three tubular elements start to heat up (go red), takes approx.5 minutes.

TYL Sense Crown Combi Elite - THE INSTALLATION

TYL Sense Crown Combi Elite - Cord anchorage

Figure 22: Cord anchorage – When use of 5×1.5 mm² cable

  1. Unscrew and turn the lock piece
  2. Mount it back
  3. Tighten the cable

Description of cabling/modular contacts

TYL Sense Crown Combi Elite - Description of cabling

  1. Modular plug RJ10, used with cable (max. cable cross-section for connection of modular plug: 0.14-0.20 mm² / AWG26-AWG24)
  2. Modular jack RJ10, connected to relay board and control panel
  3. Relay board “high” (Pos. 6-9 white connectors)
  4. Cable/lead connected to the modular plug must be multithreaded
POs r Use pin Comment Pint Pin 2 Pin 3 Pin 4
1 – NTC Temp. sensor in the room 2, 3

| 10k4. May also be con-nected at Pos 4 – SEC/ NTC.| Not use| 10k0| 10k0| Not use
2 – EXT SWITCH| External switch| 3, 4

| Start/stop operation. Constant or impulse deactivation.| Not use| Not use| Switch| Switch
External switch with LED indica-lion| 2, 3,

4

| Start/stop operation. 12VDC max. 40mA.
Tylb Item no.: 90908048| Not use| Led GND| Switch| Switch /
Led 12V
3 -DOOR SWITCH| Door contact (NO)| 3, 4| Tylb Item no.: 90908035| Not use| Not use| Switch| Switch
Door contact (NO) with an exter- nal alarm indication| 2, 3, 4| 12VDC max. 40mA. External junction box, not for sale.| Not use| Led GND| Switch| Switch /
Led 12V
4 – SEC/NTC| Combined tempe- rature sensor/cut- out in the room| Temp. sensor 10k4| 2, 3| Only used for certain products.| Sec| 10kil| 10kD| Sec
Temperatu- re cut-out 130°C| 1, 4

Adapter for activation of opera-ting status| 1, 4| Steam Commercial| Sec| Not use| Not use| Sec
5 – ADD-ON| Extra relay board| 1, 2, 5,6, 3, 7, 4, 8| Note: Not for network connection.| | | |
6-9 – RS485| Control panels| 1, 2, 3, 4| Tylb Elite and Pure con-trol panels.| A (RS485)| B (RS485)| 12V| GND
Temp./Humidity sensor %| 1, 2, 3, 4| Combi heater with Elite control panel and Tyla- rium.| A (RS485)| B (RS485)| 12V| GND
Synchronisation cable NB| 1, 2| Multisteam and Tylarium. Primary and secondary units.| A (RS485)| B (RS485)| Not use| Not use

Table 3: Description of relay board connections

NOTE! Crimp pliers are needed if changing modular cabling, e.g. shortening wires.

Dimensions / weight

TYL Sense Crown Combi Elite - Dimensions

| |
---|---|---
Crown Combi Elite 6| 33,5| 53,5
Crown Combi Elite 8| 34| 54
Crown Combi Elite 10| 34| 54

TYL logo

Please keep these instructions!.
In the event of problems, please contact the retailer where you purchased
the equipment.
© This publication many not be reproduced, in part or in whole, without
the written permission of Tylö. Tylö reserves the right to make changes to
materials, construction and design.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals